SPECIAL REPAIR OF ALL PIPE LINES AND ALLIED PARTS OF CHS PLANT NO 4 AND 5 AT TRANSIT CAMP UNDER GE 865 EWS, LEH
2026_MES_789219_1
138WE/L-96/2026-27
Open Tender
Civil Works
Item Rate
180 days
GE 865 EWS
As per Tender Documents
6 documents required · 6 mandatory
₹1,000
Yes
GE 865 EWS
₹2.2 L
Yes
12 Sept 2026
12 Sept 2026
17 Oct 2026
12 Sept 2026
10 Oct 2026
3 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | BOILER (Hot Water Suply Plant). Dismantling of burner assembly installed at Transit Camp and removing of side cover and repairing the same by removing the old burnt fire refractory cement plastering, replastering the same as per existing with fire refractory cement for boiler capacity upto 4 lakh kilo/cal/hr and complete servicing the boiler by removing the complete carbon/oil deposits with suitable coil shine chemical including repair to coil assembly by welding if there is any leakage found or any other repair required at site and reassembling/ testing the same, complete all as specified and/or as directed by Engr-in Charge. | 5 | Each Job | - | - |
| 2 | Dismantling of boiler capacity 3 to 4 lakh kilo/cal/hr disconnecting all electric/fuel/water connection of unsv glycol tubing to isolate combustion chamber of boiler and with help of tripod and chain pully without damaging internal chamber and supply and fix of boiler coil for 3 to 4 lakh kilo/cal/hr capacity Central Heating Plant as per existing shape size & dimension as per manufacturer's recommendations, complete all as specified and/or as directed by Engr-in Charge.
Make : Aquatherm/ Themax or equivalent as approved by GE. | 1 | Each Job | - | - |
| 3 | S&F in sequence controller suitable for 3 to 4 lakh kilo/hr with burner rod assembly, as per existing model, complete all as specified and/or as directed by Engr-in Charge.
Make- Siemens. | 2 | Each | - | - |
| 4 | S&F in replacement of ignition rod suitable for 3 to 4 lakh kilo/Cal/hr burner rod assembly,as per existing model, complete all as specified and/or as directed by Engr-in Charge. | 2 | Pair | - | - |
| 5 | S&F in replacement of ignition transformer electronic type suitable for 3 to 4 lakh kilo/Cal/hr burner rod assembly as per existing model, complete all as specified and/or as directed by Engr-in Charge. | 2 | Each | - | - |
| 6 | S&F temp controller digital type DTC 503 with sensor suitable for 3 to 4 lakh kilo/cal/hr LAL 2.25 burner rod assembly as per existing model, complete all as specified and/or as directed by Engr-in Charge. | 2 | Each | - | - |
| 7 | S&F in replacement of pressure gauge 0 to 10.6 Kg/sqcm as per existing model,complete all as specified and/or as directed by Engr-in Charge. | 12 | Each | - | - |
| 8 | S&F in replacement of photo cell suitable for 3 to 4 lakh kilo/cal/hr burner rod assembly as per existing model, complete all as specified and/or as directed by Engr-in Charge. | 2 | Each Job | - | - |
| 9 | S&F in replacement of burner nozzle suitable for 3 to 4 lakh kilo/cal/hr as per existing model, complete all as specified and/or as directed by Engr-in Charge. | 2 | Each | - | - |
| 10 | S&F in replacement of Electrode suitable for burner of capacity 3-4 lakh kilo/cal/hr as per existing model, complete all as specified and/or as directed by Engr-in Charge. | 2 | Set of 4 | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
TenderL96202627.pdf
Tender Documents • 1.09 MB
BOQ_884694.xls
BOQ • 0.55 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .