Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.4 LAccepted-AOC | L1 | Accepted-AOC Being L1 and Accepted | |
| 2 | L2₹52.4 L+₹1.1 L (2.13%)Rejected-Finance WZ 1000 B NANGAL RAYA PANKHA ROAD NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹52.7 L+₹1.4 L (2.80%)Rejected-Finance RZ 212F D BLOCK RAJ NAGAR PART II PALAM COLONY NEW DELHI 110077 | SOUTH WEST | DELHI | 110077 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹58.8 L+₹7.6 L (14.7%)Rejected-Finance NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹63.2 L+₹12.0 L (23.4%)Rejected-Finance SHOP NO 33 GOPI NATH BAZAR DELHI CANTT 10 | DELHI CANTT | NEW DELHI | DELHI | 110010 | L5 | Rejected-Finance Not being L1 |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
9 Dec 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE UTILITY ELECTRIC SUPPLY
GE UTILITY ELECTRIC SUPPLY DELHI CANTT
SPECIAL REPAIR AND REPLACEMENT OF OLD US STEEL TUBULAR POLES INTO ORNAMENTAL POLES FROM VEER NAARI CIRCLE TO CASSEL ROAD T POINT AND MALL ROAD CIRCLE TO INF MESS UNDER GE U ES DELHI CANTT 10
2024_MES_684264_1
GE ELECT/D-62/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE UTILITY ELECTRIC SUPPLY
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
Yes
GE UTILITY ELECTRIC SUPPLY
₹99,000
Yes
20 Jan 2025
18 Nov 2024
11 Dec 2024
18 Nov 2024
9 Dec 2024
2 Dec 2024
Amount
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft/loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom suface to required level complete all as specified and directed by Engineer- in- Charge.
Returning filling in, Including spreading, levelling, Watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and directed by Engineer- in- Charge.
Removing excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point complete all as specified and directed by Engineer- in- Charge.
M&L for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified and directed by Engineer- in- Charge. Note : Measurement shall be taken after punning down.
S&F sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as specified and directed by Engineer- in- Charge.
All as per srl item No 5 here-in-before but using old bricks obtained under srl item No. 01 complete all as specified and directed by Engineer- in- Charge.
Supply, laying, jointing, testing and commissioning in replacment of LT underground cables 1100 volts grade, PVC insulated XLPE and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors, IS-1554 marked, laid in trenches complete all as specified and directed by Engineer- in- Charge. Cables of the following sizes:- Note Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately.
16 Sqmm 4 core
35 Sq mm 3.5 core.
Taking down old unservicable steel tubular poles of any type and supply & installing of Ornamental Cast iron pole of total height 7 Mtr nominal above the foundation top level with (1.5 to 2 L x 2 W) mtr long single arm designer bracket fabricated out of cast iron embellishment, joints, column ,sections etc reinforced internally with a pipe inside. The bottom column should have an integral inbuilt looping box with cover duly mounted with one No. MCB, SP, 10 Amp, one No. 32 Amp, 4 way heavy duty connector and earth stud including S&F of 3 core, 1.5 Sqmm PVC insulated and PVC round sheathed, copper conductor cable, 1100 Volts from MCB to street light. The pole and bracket shall be painted with polyurthane paint antique colour finish of approved colour finish complete all as per manufacturer's instructions and complete all as specified and directed by Engineer- in- Charge. Note:- Sketch of pole with bracket is attached as appendix 'A'-I. Make : Hi-lite Luminaries Note:- (a) The unit rate in this item is deemed to be include the cost of exacavation and earth work of any type of soil incuding dismantling of PCC foundation of unserserviciable pole ,RCC for foundation 1:2:4 type B-1 minimume size 0.6mx0.6mx1.5m for new pole including supply and erection of EN-grade foundation Bolt M20*750mm long complete. Foundation for new pole to be made as per manufacturer's recommendations and approved by GE. (b) The quoted rate shall also include replacement of chequered tiles or cement/PCC damaged during pole removal or installation and must be repaired by Contractor. No extra payment will be given on this account.
S&F in replacement of suspension type street light fitting, made of spun aluminium housing, polycarbonate diffuser protector with IP 65 protection for optical compartment with 90 Watt LED system, CCT 5700K (Monarch King Crown -s ). Make - Bajaj (Borage) / Philips / Schneider / Hi-lite.
Note:-. 1. The manufacturer of board / panel shall submit a copy of type test report of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60 439-1 and IEC 61 439-2 for power switchgear and control gear assembly. The contractor must be submitted routine test certificate from manufacturer/principal company in accordance with IEC 60 439-1. The type test report as per CPRI (in accordance with IEC 60 439-1) should consist with following: i) Degree of protection of system ii) Temperature Rise Limit iii) Dielectric Properties iv) Short Circuit Withstand Strength v) Effectiveness of protective circuit vi) Clearance and creepage distance vii) Mechanical Operation 2. For better safety the Polycarbonate encl shall be fire retardant & self-extinguishing in accordance with IEC 60 695-2-1,DIN VDE 0304 Part 3, UL Subject 94 for Flammability V-2. It should be tested at Glow Wire test for 960 deg. Cent. 3. The impact strength of polycarbonate enclosures / boards i.e. the Degree of Protection against Mechanical load shall be in accordance with EN 50298-98 for IK 08. 4. The board manufacturer must submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. 5. The quoted rate includes the excavation, earth work and required base for fixing the complete panel.
Boring of holes under road, pavement, hard standing by trenchless technology including 150 mm dia HDPE pipe suitable for 0.6 mpa working pressure complete all as specified and directed by Engineer- in- Charge. Note: The Rate for taking permission from concerned authority like Army Signal and other utility authority are deemed to be included in the quoted rates. If any utilities like road damaged duinng execution of work, the same will be repair/replaced by the Contractor in quoted rates.
Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 4 mm dia by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed by Engineer- in- Charge and shown in electrical plate number 3 of MES SSR part-I(1991).
S&F for multi core round PVC insulated copper conductor (flexible) industrial cables PVC sheathed cables, 1100 volts conforming to IS : 694 of size 2.5 Sqmm, 3 core panel to street light inside/outside pole complete all as specified and directed by Engineer- in- Charge.
S&F for multi core round PVC insulated copper conductor (flexible) industrial cables PVC sheathed cables, 1100 volts conforming to IS : 694 of size 4 Sqmm, 3 core panel to street light inside/outside pole complete all as specified and directed by Engineer- in- Charge.
S&F of 5.29 Mtr Ornamental Clock lamp post made out of cast iron pole FG-15 grade cast iron four side cell operated 2ft square clock. The clock lamp post shall be painted by attractive antique looking paint of copper/gold/green colors with black base as required to give it a rich antique look. All parts are clean by shot blasting or sand blasting process. polyurethane primer color coat further painted with polyurethane type black paint, followed by coat of metal powder to give an antique effect and then a final coat of clear LAQUARE film for protection & increasing life of color complete all as specified and directed by Engineer- in- Charge. Note:- Sketch of pole with bracket is attached as appendix 'B'-I. Make : Hi-lite luminaries Cat Part No. HL-7501 Note:- The unit rate in this item is deemed to be included of the cost of exacavation and earth work of any type of soil incuding dismantling of PCC foundation of unserviceable pole, RCC for foundation 1:2:4 type B-1 minimum size 0.6mx0.6mx1.5m for new pole including supply and erection of EN-grade foundation Bolt M20*750mm long complete all as specified and directed by Engineer- in- Charge. Foundation for new pole to be made as per manufacturer's recommendations and approved by GE.
Taking down old unservicable steel tubular poles of any type and supply & installing of Decorative pole complete with led fitting ,aluminium cast pole of total height 5 Mtr nominal above the foundation top level with long arm designer brackets fabricated out of cast iron embellishment, joints, column ,sections etc reinforced internally with a pipe inside. The bottom column should have an integral inbuilt looping box with cover duly mounted with one No. MCB, SP, 10 Amp, one No. 32 Amp, 4 way heavy duty connector and earth stud including S&F of 3 core, 1.5 Sqmm PVC insulated and PVC round sheathed, copper conductor cable, 1100 Volts from MCB to street light. The pole and bracket shall be painted with polyurthane paint antique colour finish of approved colour finish complete all as per manufacturer's instructions complete all as specified and directed by Engineer- in- Charge. Note:- Sketch of pole with bracket is attached as appendix 'C'-I . Make : Ignite Electronics Cat Part No. IG DP-24-50 Note:- The unit rate in this item is deemed to be include the cost of exacavation and earth work of any type of soil incuding dismantling of PCC foundation of unserserviciable pole ,RCC for foundation 1:2:4 type B-1 minimume size 0.6mx0.6mx1.5m for new pole including supply and erection of EN-grade foundation Bolt M20*750mm long complete. Foundation for new pole to be made as per manufacturer's recommendations and approved by GE.
mayur enterprises (BID ID -3182576)
MV Engineers And Contractors (BID ID -3181137)
Vijay Electricals (BID ID -3184814)
M/s JAIMAA ASSOCIATES (BID ID -3183143)
Rajindera Enterprises (BID ID -3183257)
Bidder Name
M P TYAGI ENGINEERS AND CONTRACTORS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .