Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹68,000
Closing Date
2 Dec 2020, 3:00 pmClosed
GE I R AND D GIRINAGAR PUNE 411025
GE I R AND D GIRINAGAR PUNE 411025
REPAIR MAINT OF HT LT SYSTEM TRANSFORMER LT PANELS OH LINES LT UG CABLES STREET LIGHT FITTINGS SECURITY LIGHTS GATE LIGHTS GARDEN LIGHTS AND ALLIED WORKS IN RESIDENTIAL AND TECHNICAL AREA AT DIAT DU AND MILIT GIRINAGAR PUNE
2020_MES_392701_1
GE I R AND D GNR TOKEN 48 OF 2020 21
Open Tender
Civil Works
Works
270 days
GE I R AND D GIRINAGAR PUNE 411025
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE I R AND D GIRINAGAR PUNE 411025
₹68,000
Yes
9 Dec 2020
5 Nov 2020
3 Dec 2020
5 Nov 2020
2 Dec 2020
20 Nov 2020
5 Nov 2020 - 12 Nov 2020
Amount
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth and getting out in Soft / loose soil including forming bottom surface etc.
Returning, filling in including spreading, levelling ,watering and well ramming in layers not exceeding 25 cm thick complete in soil.
Removing excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 50 mtr above the starting point.
M & L for Surface excavation not exceding 30 cm deep in hard dense soil and averaging 15 cm deep and getting out green vegetation, roots, bushes, etc surrounding of 2 / 4 / 6 pole structure / substations / RMU all as directed by Engr-in- charge.
Material and labour for cutting of bituminous road / floor for laying of pipe / cables 45 CM wide and not exceeding 1.5 meter deep including refilling / with material and , watering well ramming / compacting and making good with PCC 1;2;4,type B-1, 100 mm thick complete all as specified and directed by Engr-in-Charge.
Supply & Laying 50 mm outside dia double wall corrugated pipe (DWC) of HDPE ISI Mark for enclosing cable below ground / road surface, to a required depth, including suitable size coplers for jointing of pipe all as per site requirement
Supply & Laying 75 mm outside dia double wall corrugated pipe (DWC) of HDPE ISI Mark for enclosing cable below ground / road surface, to a required depth, including suitable size coplers for jointing of pipe all as per site requirement
M &L for GI pipe light grade in repair for road crossing / on wall / on pole for cable protection of following size:- Make: TATA/JINDAL/ PRAKASH SURYA. a) 50 mm dia
M & L to find out fault in LT line bring/call fault finding machine equipment and find out fault in any size of LT UG Cable including disconnecting of cable connection from both side panels/poles and necessary excavation in any type of strata to reach upto cable and making space for cable joint. Note:- (i) Cable required at site same size of faulty cable if required for jointing purpose will be paid in relevant item. (ii) Jointing material will be paid in relevant Item.
M & L to find out fault in HT line bring/call fault finding machine equipment and find out fault in any size HT UG Cable including disconnecting of cable connection from both side panels/poles and necessary excavation in any type of strata to reach upto cable and making space for cable joint. Note:- (i) Cable required at site same size of faulty cable if required for jointing purpose will be paid in relevant item. (ii) Jointing material will be paid in relevant Item.
Supply and jointing straight through joint, 22000 volts grade heat shirnkable type suitable for 3 core 50sqmm to 95 Sqmm, HT, XLPE cable and testing after jointing all as specified and directed by Engr-in-charge. Make :3M / M Seal / Denson / Reychem
Supply and fix in repair straight through cable jointing kit 22 KV earthed grade heat shrinkable joint with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm all as specified. Make :3M / M Seal / Denson / Reychem
Material and labour for dismantling old cable end termination and supply and jointing new Cable end termination heat shrinkable outdoor type suitable for 22KV, 50 Sqmm to 95 Sqmm XLPE, 3 Core power cable with aluminium conductor. Make :3M / M Seal / Denson / Reychem
Material and labour for dismantling old cable end termination and supply and fixing new Cable end termination heat shrinkable outdoor type suitable for 22KV, 120 Sqmm to 185 sqmm, XLPE, 3 Core power cable with aluminium conductor. Make :3M / M Seal / Denson / Reychem
Material and labour for dismantling old cable end termination and supply and fixing new Cable end termination touch proof type outdoor type suitable for 22KV, 95 Sqmm to 185 sqmm, XLPE, 3 Core power cable with aluminium conductor. Make :3M / M Seal / Diwop/Hong shang/GCA
M & L for cable jointing kit for 22 KV earthed graded cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm to 185 sqmm. Make :3M / M Seal / Denson / Reychem
Taking down the existing defective HT UG cable of following size in trenches / pipes / pole for attending the repair,jointing materials, refixing / relaying back in trenches fixed on poles complete all as specified and directed . (a) 95 sq mm 3 core upto 185 sqmm 3 core. Note-: (i) Excavation and earth work will be measured and paid seperately under relevant item. (ii) Sand & Brick to be safely /properly stagnated and reused as directed by Engr -in- Charge. (iii) Old U/S cable shall be the property of contractor and will be measured in Sch of credit]
Supply and laying HT UG Cable of size 95 sqmm 3 core heavy duty 22000 volts grade with aluminium conductor strip armoured PVC insulated and PVC sheathed incl jointing material etc. Laid in trenches / ducts / fixed on wall / pole or drawn through pipes complete all as specified.
Supply and laying HT UG Cable of size 185 sqmm 3 core heavy duty 22000 volts grade with aluminium conductor strip armoured PVC insulated and PVC sheathed incl jointing material etc. Laid in trenches / ducts / fixed on wall / pole or drawn through pipes complete all as specified.
Taking down the existing defective LT UG cable of following size in trenches / pipes / pole for fault finding /attending the repair and repair the same all as specified and directed . (a) 6 sq mm 2/3/3.5/4 core upto 50 sqmm 3/3.5/4 core.
(b) 95 sq mm x3.5 core upto 400 x3.5 core sqmm. Note-: (i) Excavation in trench also including under relevant item. (ii) If the existing cable become faulty and can not be useful, then cable/joint kit shall be provided by contractor as supply and fix . Retrived cable shall be handed over to contractor as schedule of credit.
Supply & fix heat srinkable jointing kit for 1.1 KV grade cable for straight through joint/ end joint kit complete with jointing material and accessories suitable for 2/3.5/4 core XLPE / PVC armoured AIuminium Conductor cable of following size . Make: DENSON / MAHINDRA / REYCHEM / 3M . (a) 16 sqmm to 25 sq mm
(b) 50 sqmm to 70 sq mm
(c) 70 sqmm to 95 sq mm
(d) 120 sqmm to 185 sq mm
(e) 240 sqmm to 300 sq mm
Supply and lay LT PVC/XLPE insulated, armoured,heavy duty under ground electric cable with aluminium conductor, 1100 volts grade of following cross-sectional area including cable lugs, jointing materials etc., laid in trenches fixed on poles or laid through GI pipes including taking down old cable. Note-: (i) Excavation and earth work will be measured and paid seperately under relevant item. (ii) Sand & Brick to be safely / properly stagnated and reused as directed by Engr -in- Charge. (iii) Old U/S cable shall be the property of contractor and will be measured in Sch of credit. (a) 2 core 6 sq. mm
(b) 2 core 10 sq. mm
(b) 2 core 16 sq. mm
(c)4 core 16 sq. mm
(d) 3.5 Core sec. area 25 sq. mm
(e) 3.5 Core sec. area 35 sq. mm
(f ) 3.5 Core sec. area 50 sq. mm
(h) 3.5 Coret sec. area 95 sq. mm
(k) 3.5 Core sec. area 185 sq. mm
(l) 3.5 Core sec. area 240 sq. mm
(m) 3.5 Core sec. area 300 sq. mm
Strengthening and Restringing of HT/LT over head ACSR conductor of any size in overhead lines inlcuding removing and replacement of binding wire from insulators and triming the branches on both / above side of the line before,stringing and rebinding of insulators after stringing complete all as specified and as directed by Engineer - in - Charge.
Dismantling of old unserviceable stay assembly including stay wire complete (Note-necessary demolition of concrete, excavation and earth work are included )
M & L for fixing L T Pole Stay assemblies shall comprise of stay clamp, stay wire( 7/ 2.24MM), stay insulator, stay grips, thimble staybow, on existing 20 mm dia stay rod (including excavation ,concrete and stay plate )
Dismanlting of old jumper, including supply and fixing new jumper connection at cut point on HT / LT over head line with suitable size of ASCR conductor 6 / 1 x 3.00 mm (ferrel) PG Clamps, lugs, alkathine sleaves complete of required length not exceeding 3 mtr inlcuding testing on completion complete all as specified and as directed by Engineer - in - Charge.
M&L for ACSR conductor on existing poles including dismantling of unsv ACSR conductor all as directed and as specified.
Servicing the 22 KV GOD by cleaning the contact, disc/pin insulator with CTC & applying the petrolium jelly at the contact point/down rod links for smooth operation including replacing the rusted/corroted bolts & nuts and defective insulator of GOD as required at site. Note :- Insulator shall be measured and paid under relavant items.
a) Male / Moving contact ( set of 3 Nos )
b) Female / Fixed contact ( set of 3 Nos )
c) Copper tinned strip ( set of 3 Nos )
Material and labour for dismantling old U/S AB switch and Supply, installation. connecting electrically & commissioning switch air break, gang operated, tripple pole mounted on insulators 15 Nos with drop out fuse and steel frame with operating mechanism in working from ground level, including jumper connection with ACSR conductor alongwith PVC pipe covering with colour code between main supply and GOD complete all as specified and directed for current rating upto 200 amps and working voltage 22000 volts all as required at site or directed by Engr-in-charge.Make: Jaipuria/BHEL
All as per item no 30.00 above but of capacity 400 amps
Cutting / trimning of Tree branches which are touching to HT / LT over head lines and clearing the same up to 4 meter radius for span length not exceeding 45 to 55 meter complete all as specified and as directed by Engineer - in - Charge. (Note: Each span of 45-55 Mtrs will be considered as one length of span for payment purpose)
M & L for painting of steel tubular LT pole up to 9 mtr long with two coats of aluminium paint incl cross arms (for single pole), clamps etc complete including marking of pole No with black paint with all arrangement for ladder etc all as specified and directed.
M & L for fixing of line seprator suitable for LT line four conductor feeder all as specified.
M & L for fixing of line seprator suitable for LT line three conductor in horizontal /vertical feeder all as specified.
Isolate/de-energize the supply to the HT/LT Panel Board of capacity ranging from 200 Amps to 2000 Amps, opening the doors/covers of the cubicle enclosure for carrying out the servicing/maintenance/repairs of the Panel Board, switch gear, metering etc and re-fixing the same in place after repairs including testing and commissioning of the panel board comprising of the following:- a) Cleaning the inside switch gear chambers for removing dust, carbon and rusted surfaces including cleaning with blower and apply insulating varnish. b) Check the condition of the DMC/SMC support insulators including cleaning applying Dr beck red for better IR values and replacement of insulators if required. c) Tightening up of all bus bar connections, cable connections, replace bolt, nuts wherever required. Note : Contractor has to inspect the site before quoting. Any modifications/frame work and renewal is deemed to be included in the quoted rates. Spares will be measured and paid under relevant items of schedule
S&F in repair mild steel hinges suitable for LT panel board shutters including welding, riveting complete all as specified and as directed.
Disconnecting and taking out old existing worn out control wiring connections including cable lugs of LT panel board of 4 wire system and supply and connect with new cable PVC insulated, stranded copper conductor 2.5 sqmm including with new copper lugs and nuts, bolts, washers complete all as specified and directed.
Disconnecting and taking out old existing worn out cable lugs, nuts, bolts, washers etc from LT panel board of 4 wire system (incomming and outgoing) and supply and connect with new aluminium lugs all sizes as per site requirement and nuts, bolts, washers etc complete all as specified and directed.
Material and labour for dismantling of old steel tubular pole and suppy, errecting in truly vertical position steel tubular swaged pole 11 mtr long with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP 55, including painting with anti corrosive paint internally complete and externally up to planting depth, alternative white & black strips of 30 cm width upto 1.5 mtr above ground level all as required at site.
Material and labour for dismantling of old steel tubular pole and suppy, errecting in truly vertical position steel tubular swaged pole 9.0 mtr long with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP 55, including painting with anti corrosive paint internally complete and externally up to planting depth, alternative white & black strips of 30 cm width upto 1.5 mtr above ground level all as required at site.
M&L for PCC 1:4:8 Type D2 using 40 mm graded aggregate in foundation including form work and finishing the exposed surface of concrete even and smooth complete all as specified and directed.
M & L for PCC 1:3:6 type, type C-2 using 40 mm graded aggregate in foundation of stay, for making good the disturbed portion of road/floor/platform etc including necessary form work complete all as specified and directed.
M&L for providing PCC 1:2:4 type B-1 with 20 mm graded aggregate for coping of pole complete all as specified and directed.
S& F in replacement of MCCB 3 Pole 63 Amps 16 kA Thermal magnetic adjustable type & should be Ics=Icu=100% with both side spreader links all as specified and directed. Make : Legrand /Siemens/ABB/L&T
S& F in replacement of MCCB 3 Pole 100 Amps 16 kA Thermal magnetic adjustable type & should be Ics=Icu=100% with both side spreader links all as specified and directed. Make : Legrand /Siemens/ABB/L&T
S& F in replacement of MCCB 3 Pole 160 Amps 25 kA Thermal magnetic adjustable type & should be Ics=Icu=100% with both side spreader links all as specified and directed. Make : Legrand /Siemens/ABB/L&T
S& F in replacement of MCCB 4 Pole 200 Amps 25 kA Thermal magnetic adjustable type & should be Ics=Icu=100% with both side spreader links all as specified and directed. Make : Legrand /Siemens/ABB/L&T
S& F in replacement of MCCB 4 Pole 250 Amps 25 kA Thermal magnetic adjustable type & should be Ics=Icu=100% with both side spreader links all as specified and directed. Make : Legrand /Siemens/ABB/L&T
S& F in replacement of MCCB 4 Pole 400 Amps 36 kA Thermal magnetic adjustable type & should be Ics=Icu=100% with both side spreader links all as specified and directed. Make : Legrand /Siemens/ABB/L&T
S& F in replacement of MCCB 4 Pole 630Amps 36 kA Thermal magnetic adjustable type & should be Ics=Icu=100% with both side spreader links all as specified and directed. Make : Legrand /Siemens/ABB/L&T
S& F in replacement of MCCB 4 Pole 800Amps 50 kA Thermal magnetic adjustable type & should be Ics=Icu=100% with both side spreader links all as specified and directed. Make : Legrand /Siemens/ABB/L&T
S & F in replacement of ACB type manual fixed with microprocessor based LSIG & tempreture rise protection consisting of digital display with battery backup 3 ph ,4 pole , 415 Volts, 630 Ampr 50KA in existing panel & connecting to incoming & outgoing with suitable rating of Aluminium/Copper busbar properly testing of ACB all as specified and directed . Make: Legrand-DMX3-Cat No: 028730 or equivalent in ABB/Siemens
S & F in replacement of ACB type manual fixed with microprocessor based LSIG & temprature rise protection consisting of digital display with battery backup 3 ph ,4 pole , 415 Volts, 800 Ampr 50KA in existing panel & connecting to incoming & outgoing with suitable rating of Aluminium/Copper busbar properly testing of ACB all as specified and directed . Make: Legrand-DMX3-Cat No: 028731 or equivalent in ABB/Siemens
S & F in replacement of power contactor 4 pole , 415 Volts, 630 Ampr AC1 with integrated auxiliary contacts and coil voltage 200-240V AC/DC in existing panel & connecting to incoming & outgoing with suitable rating of Aluminium/Copper busbar properly all as specified and directed . Make: Legrand/ ABB/Siemens/L&T
S & F in replacement of power contactor 4 pole , 415 Volts, 800 Ampr AC1 with integrated auxiliary contacts and coil voltage 100-240V AC/DC in existing panel & connecting to incoming & outgoing with suitable rating of Aluminium/Copper busbar properly all as specified and directed . Make: Legrand/ ABB/Siemens/L&T/Indo asian
S&F in replacment of 3 phase digital multi function meter with suitable accessories and fixing arrangements. Make : L&T, Cat no CORNEL 4380 or its equivalent
S&F in replacment of voltmeter/Ammeter of range 0 to 500 Volts.
S&F in replacament of LED type phase indicator to be fitted on panel ( R,Y, B as per site requirement)
M&L for dismentling and disconnecting the ACB rating 800/630 amps Make: Crompton greaves/ C&S/ L&T by carrying out repairs/ servicing, checking and renewing the defective shunt trip coil & UV trip 415 volts AC, checking and rectifying the defective CTs and rectifying the mechanism operation including spring charging system, reinstalling the same in the panel and providing necessary line and connections all as directed by Engineer-in-charge
Material and labour for dismantling of old danger notice plate and supply and fixing danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts & nuts of approved size of 20 x 15 cm size.
M & L for Scraping of old paint from two pole structure without removing accessories and preparation of surfaces for repainting. painting of 4 pole structure with two coats of aluminium paint incl channels, DO fuse parts, clamps etc complete including marking of pole No with black paint with all arrangement for ladder and painting of bottom portion of the pole upto 1.0 m from top of the copping with one coat of synthetic enamel red paint over a coat of red oxide primer etc all as specified and directed.
All as per item no 59.00 above but for 6 pole structure.
Supply only HT fuse element 22 KV fibre glass type suitable for folloiwng :- (Make EADC/Equivalent) (a) 22 KV 50 Amps
(b) 22 KV 60 Amps
Disconnecting all the electrical connections from H.T.and L.T. side of unserviceable transformer of cap above 160 KVA to 500 KVA i.e. Jumpers/cable from the cable end box or bushings & earthing terminal of the transformers, loading and unloading of transformer & transportation by vehicle from substation to the repairing workshop including reinstallation, commissioning and testing complete.
Opening the transformer cover along with the conservator by removing the nut bolts then after removing the internal HT.& LT connections by taking them out by removing studs, bushings, taking out the core-winding assembly out of the tank removing out burnt HV and LV windings from the core assembly,Draining & decanting of burnt transformer oil and cleaning of sludge deposited in the tank with CTC of transformer having ratio 22/0.433 KV . Rewinding of HV and LV coils with suitable size super enamelled copper wire / strip ( As Existing ) having suitable class insulation material . Heating of core winding assembly in hot chamber for 48 hours and remove all the moisture present in it , removal of leakage of tank if any by welding, refilling transformer oil to tank , after putting the core-winding assembly into the tank, reassembling making the internal H.T. & L.T. connections by fixing the studs, bushings,fitting the top cover by replacing cork sheet gasket along with conservator, testing the transformer in the workshop, all as directed by Engineer-in-charge.for various capacities as under :- a) upto 160KVA
b) All as per item no 67.00 above 160KVA to 400 KVA
c) b) All as per item no 67.00above 400KVA upto 650KVA Note: (i) U/S items required for repairs shall be measured and paid under relevant item of this schedule. (ii) Transformer oil with die electric strenght not less than 40KV either new or filtered shall be filled and shall be measured and paid separately under respective item. (iii) Following Routine test to be carried out at work shop :-(a) IR value. (b) High voltage test. (c ) Ratio test. (d) Short circuit test. (e) BD value of oil
Supply only super enamelled copper winding wire / strip of any size for H.T coils of transformers
Supply only copper winding wire/ strip of any size for L.T. coils of transformers including providing insulation all as required.
Reconditioning of LT coil of copper wound transformer by turning the old paper insulations, straightening the entire LT Strip providing new paper insulations of superior quality and making coil of suitable design as original all as specified and directed by Engr-in-Charge.
Supply & fix HT Bushing(as per sample)
Supply & fix LT Bushing(as per sample)
Supply & fix brass stud (for LT433V side)of suitable size complete with one chuck nut, two nuts, washers and rubber seal, all as per sample for outdoor type transformer of the capacity as under:- a) upto 160 KVA
b) All as per item no 73.00above 160KVA upto 250KVA
c) All as per item no 73.00 above 250KVA upto 650KVA
Supply & fix brass stud (for HT 22KV side) of suitable size complete with one chuck nut, two nuts, washers and rubber seal, all as per sample for outdoor type transformer of the capacity as under:- a) upto 160KVA
b) All as per item no 74.00 above 160KVA upto 250KVA
c)All as per item no 74.00 above 250KVA upto 650KVA
Scrubing of old rusted paint from transformer and preparation of surfaces for fresh painting, by means of spray painting with two coats of synthetic enamel paint of approved colour of transformer up capacity 100 KVA to 500 KVA and writing SM No/MES No of the transformer etc complete all as specified and as directed.
M&L for dehydration of transformer oil with mobile transformer oil filtration plant at site with all accessaries connected to transformer and carrying out filteration of oil for desired dielectric strength i.e. not less than 40 KV at 2.5mm gap. Note :- 1. Test certificates shall be submitted before and after filteration for dielectric strength on the proper format .
M & L for replacement of breather assembly of transparent plastic body with top and bottom portion pressed with metalic cover, filled with silica jel blue in colour and suitable for pipe entry of 15/20/25mm dia as per the site requirement, complete all as specified and as directed by Engineer-in-Charge.
Supply and Filling/ topping up new transfermer oil of approved make conforming to IS- 335 / 1983 including testing of IR value of the oil not less than 60 KV, complete all as specifaied and as directed by Engineer - in - charge. Make : Power Oil/ HP/ BP
M&L for earth testing, identifying the earthings in system and recording the results on indicator board and producing three copies of test sheet duly signed by Contractor/ JE/ AGE E/M all as directed by Eng-in-charge. Note :- (i) Cost of labour and tools required for testing is deemed to be included in quoted rates.
M&L for earthing with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25M deep below ground level with top edge of the plate not less than 1.5M below normal ground level connected to galvanised strip 32x6mm by means of nuts, bolts, checknuts, washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part I connected to earthing test point including excavation/ earth work in any strata removal of surplus earth, GI pipe for watering and funnel, PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 in cover slab with 40mm dia light grade GI protection pipe and 20mm dia light grade GI pipe for watering all as specified and directed by Eng-in-charge.
M&L for earthing with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25M deep below ground level with top edge of the plate not less than 1.5M below normal ground level connected to GI Earth wire 4 mm by means of nuts, bolts, checknuts, washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part I connected to earthing test point including excavation/ earth work in any strata removal of surplus earth, GI pipe for watering and funnel, PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 in cover slab with 40mm dia light grade GI protection pipe and 20mm dia light grade GI pipe for watering all as specified and directed by Eng-in-charge.
M&L for hard core of broken stone or boulders of gauge n. exc. 63 mm, deposited, spread and leveled in layers n. exc. 15 cm thick, watered and rammed to a true surface.
S&F in replacement of timer switch 16 Amps, 230 Volts, 24 hrs dial type for operation with by pass operation. Make :- Legrand Cat No 6499 15, MaxiRex 4QT (daily) or equivalent in GIC/L&T/ Indoasian
S&F in replacement of triple pole power contactor suitable for 40 Amps, with coil voltage 230 Volts. Make: L&T/ Siemens/ GE.
Supply and fix outdoor type FRP junction box light weight suitable for pole mounting includin flat iron clamp duly painted with two coats of aluminium paint over a coat of red oxide primer and GI nut, bolts, washers and necessary connector for loop in loop out cable connection and suitable size galnds, of size 250x200x105 mm. Make - Syntex/ Anchor
Supply and fix inreplacement of 3 x 1 sq mm PVC Cercular copper cable for connection of street light fitting, Security light fitting, post top lantern and garden light fitting and including all fixing arrengenment with proper fixing all as directed by Engr in charge.
Dismentling and taking down existing any type ( Street light/Bulk head/ Tube light) fitting fixed on bldgs/poles /wall.
S & Fix LED Street light fitting 90 Watts High performance IP 66 LED street light luminaires with complete acessories all as specified and directed by Engr In charge Make - Wipro Cat part no :- LR02-102-XXX-57-G2 or eqvt in Bajaj/ Havells/Crompton.
S & Fix LED Street light fitting 60 Watts High performance IP 66 LED street light luminaires with complete acessories all as specified and directed by Engr In charge Make - Wipro Cat part no :- LR02-671-XXX-57-G2 or eqvt in Bajaj/ Havells/Crompton.
Supply & fix LED 35W decorative post top lantern for 360 degree indirect light, made in cast aluminium with decorative opal polycarbonate diffuser with IP 65 protection, resistance to impact and corrosion, glare free and better uniformity all as directed and specified. Make- wipro Cat No - LP07-431-XXX-57-CL or equivalent in Crompton/Philips/Havells/Bajaj
M & L for replacement of unserviceable MS clamp with new clamp as per sample/as per site requirement made out of MS flat iron 25 x 5mm including fixing nuts bolts, vashers etc and painting with two coats of syntetic enamel paint over a coat of red oxide primer complete all as directed
Supply and fix electronic driver for LED street light fitting as per sample/existing fitting specifications complete with all accessories as suitalable for street light fitting of size 90 Watt. Note- Quoted rate include replacement of driver and testing and making fitting serviceable and upto JE/Engr-in-Charge satisfaction.
Supply and fix electronic driver for LED street light fitting as per sample/existing fitting specifications complete with all accessories as suitalable for street light fitting of size 60 Watt. Note- Quoted rate include replacement of driver and testing and making fitting serviceable and upto JE/Engr-in-Charge satisfaction.
Supply and fix electronic driver for LED street light fitting as per sample/existing fitting specifications complete with all accessories as suitalable for street light fitting of size 30/45 Watt Note- Quoted rate include replacement of driver and testing and making fitting serviceable and upto JE/Engr-in-Charge satisfaction.
To facilitate in attending Electrical complaint of external electrification/street lights in residential and technical area of DIAT(DU) and milit with qulified one x electrician all as specified and directed by Engr-in-charge- ( i) One Electrician from 0900 Hrs to 1700 Hrs. (ii) Electrician shall be employed all working days incl Sundays and holidays . (iii) The unit rate quoted by the contractor shall be inclusive of working & attending the complaints as directed by Engr-in-charge. (iv) The electrician who is on duty must be provided with common mobile cell to facilitate and render good services to the users and the same shall be deemed to be included in the unit rate. (v) Complaint slip to be collected daily from complaint cell and same shall be returned to the complaint cell on completion of job. (vi) All relevant norms and IE rules provisions shall be adhered while working on electric circuits and necessary protective devises and tools required shall be inclusive of the provisions and the same shall be deemed to be included in the unit rate. (vii) Contractor shall provide all tools required for attending complaint with proper tool bag. (viii) Any emergency HT/LT fault shall be rectified as per direction of Engr-in-charge/JE E/M (ix If individual remains absent on site, contractor shall make an alternative arrangement ,If contractor fails to make such arrangement recovery shall be made at double the quoted rate as specified in Sch A as per included for same.
SOURABH ENGINEERS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .