Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.6 LAccepted-AOC MURSTEY COLONY PLOT NO 16 LEH 194101 LADAKH | LEH LADAKH | LADAKH | 194101 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹43.9 L+₹6.4 L (17.1%)Rejected-Finance R O ZANGSTI LEH LADAKH 194101 | LEH | LEH | LADAKH | 194101 | L2 | Rejected-Finance Being Other Than Lowest Bidder | |
| 3 | L3₹45.5 L+₹7.9 L (21.1%)Rejected-Finance | L3 | Rejected-Finance Being Other Than Lowest Bidder |
Tender Value
₹38.8 L
EMD Value
₹77,660
Closing Date
5 Apr 2025, 6:00 pmClosed
GE 873 EWS
Garrison Engineer 873 Engineer Works Section PIN 913 873 C/O 56 APO
SPECIAL REPAIR TO BLDG No T-30 (CG BN), T-104 (ARTY REGT) AT BASE CAMP AND T-52 (SUP PL) AT KHALSAR UNDER AGE B/R-II OF GE 873 EWS
2025_MES_699619_2
GE/873/EWS/94/2024-25
Open Tender
Civil Works
Item Rate
180 days
GE 873 EWS
Please refer NIT and Tender Documents
8 documents required · 8 mandatory
₹500
GE 873 EWS
₹77,660
Yes
9 Apr 2025
22 Mar 2025
7 Apr 2025
22 Mar 2025
5 Apr 2025
29 Mar 2025
Amount
Schedule 'A' Part-I (B/R itmes) Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing servicable tiles to store and rubbish off the premises complete, all as specified and as directed.
Material and labour for 25 mm thick PCC 1:2:4, type B0, (using 12.50mm graded crushed stone aggregate) as in levelling course or floor sub base, finished even & fair without using extra cement complete all as specified and as directed by the Engineer–in–Charge.
Material and labour for non–skid ceramic coloured tiles joint free premium/1st quality (square/rectengular) 7 to 8 mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floor, set and jointed in neat cement slurry and pointed in coloured cement to match the surface over and including screed bed 15 mm thick in cement mortar 1:6 complete all as specified and as directed by the Engineer–in–Charge.
Dismantling wall and ceiling boarding of any type, thickness or description, any description, fixed in position with nails, screws including cover filllets complete all as specified and directed by the Engineer–in–Charge
M&L for 9mm thick prelaminated particle board, in wall interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed in wall with nail to timber frame work complete all as specified and directed by the Engineer–in–Charge.
M&L for 9mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, in ceiling fixed with nail to timber frame work complete all as specified and directed by the Engineer–in–Charge
Dismantling timber in fillets, rails, post, rafters purlins etc under 40 sq cm in section complete all as specified and directed by the Engineer–in–Charge
M&L for plain fillet 2nd class soft wood section are exc 13 but n exc 25 Sqcm in square, rectangular or triangular in section, clean sawn, secure with nail or brads complete all as specified and directed by the Engineer–in–Charge
M&L for plain fillet 2nd class soft wood section are exc 3 but n exc 6 Sqcm in square,rectangular or triangular in section, clean sawn, secure with nail or brads complete all as specified and directed by the Engineer–in–Charge
Dismantling of plain or corrugated steel or AC sheeting any gauge, thickness including nainital or similar pattern roof /wall cladding covering, complete all as specified and directed by the Engineer–in–Charge
S&F for galvanised mild steel sheeting of 0.63 mm thick corrugated with two corrugation side laps and fixed with J hookes two framed work with PVC and steel washers as in roof or wall cladding etc. with grade of zinc coating 275 all as specified and directed by the Engineer–in–Charge.
S&F for plain, galvanised, mild steel sheeting of 0.63 mm thick, in ridges, hips, valley gutters, drip and straight flashings etc. (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed by the Engineer–in–Charge
Material and labour for preparation of new/previously untreated steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by the Engineer–in–Charge.
Material and labour preparation of old decorated steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coat of synthetic enamel paint complete all as specified and as directed by the Engineer-in-Charge.
Taking down chowkats or frames with shutter area exceeding 1.50 Square meter and not exceeding 4.00 Square meter (without taking off shutters from the frames) and removing from site, including cutting holes for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces to match with existing finish complete all as specified and as directed by the Engineer–in–Charge.
Taking down chowkats or frames with shutter area not exceeding 1.50 Square meter (without taking off shutters from the frames) and removing from site, including cutting holes for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces to match with existing finish complete all as specified and as directed by the Engineer–in–Charge.
Dismantling of timber scantling 40 sqcm hard wood frames and over in section, in any position as specified and directed by Engineer-in-Charge.
S&F plain, solid, straight chowkats of second class hard wood and frames, wrought, framed rebated on the solid, rounded or chemfered, put together with glue pinned at joints complete all as specified and directed by the Engineer–in–Charge
S&F 30mm thick 2nd class hard wood plain, framed, panelled shutters (two or more panels) with lock rail and panels of 9mm thick BWP commercial, ply or 12mm thick veneered particle boards. The size of rail and style as per IS-1003 (part-I) kiln seasoned and chemicaly pressure treated complete all as specified and directed by the Engineer–in–Charge.
Supply and fixing factory made 30 mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc. (without sash bars), edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass etc size of members of shutters as specified in SSR Part–I, Section–8, clause 8.24 (a) (wood shall be kiln seasoned and chemically pressure treated) complete all as specified and as directed by the Engineer–in–Charge.
Material and labour for preparation of new wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed by the Engineer–in–Charge.
Material and labour for sheet glass 3.00mm thick, ordinary quality and glazing with oil putty /wooden beading in square not exceeding 0.5 sqm in each pane complete all as specified and as directed by the Engineer–in–Charge.
Supply and fixing mild steel cold rolled butt hinges 100mm long medium weight complete all as specified and as directed by the Engineer–in–Charge.
Supply and fixing mild steel cold rolled butt hinges 75mm long medium weight complete all as specified and as directed by the Engineer–in–Charge.
Supply & fix mild steel sliding door bolts 250 mm long clip type, stove enamelled black with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on stapple plate and fixed, complete all as specified and directed by the Engineer–in–Charge
Supply and fixing 150 mm long mild steel barrel tower bolts of extruded section and fixed complete all as specified and as directed by the Engineer–in–Charge.
Supply and fixing 100 mm long mild steel barrel tower bolts of extruded section and fixed complete all as specified and as directed by the Engineer–in–Charge.
Supply and fixing 150 mm long aluminium handle fabricated type anodised complete all as specified and as directed by the Engineer–in–Charge.
M&L 150mm overall length of cover plate floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specifeid and directed by the Engineer–in–Charge.
Supply and fixing mild steel curtain rod 25mm dia with and including mild steel decorative brackets, two lotto (finials) for each rod length at both end etc fixed with stainless steel screws as in repair complete all as specified and as directed by the Engineer–in–Charge.
S&F in repairs aluminium (die cast body) door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and directed.
S&F aluminium soild body Hat and coat hooks, solid body, 175mm to 250 mm complete all as specifeid and directed.
Demolition of cement concrete (un–reinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed by the Engineer–in–Charge.
M& for providing cement concrete 1:3:6, type C-1 (using 20mm graded crushed stone aggregate), 75 mm thick as in plinth protection /hardstanding laid in bays not exceeding 2 Sqm each and finishing even and fair on top without using extra cement with 6mm wide joints throughout the thickness of plinth protection in concrete bays and in between the walling and plinth protection, filling the joints with mastic filling comprising of one part of heated bitumen 85/25 and 3 parts of sand (all by weight) complete all as specified and directed by the Engineer–in–Charge
M&L for preparation of old decorated surfaces of walls, pillers, cornices etc by scrapping down smoke soot, moulds, moss, efflorescent salts, trading oil and greasy spots and scrapped surface area to obtain smooth finishing as required and applying two coats of cement based paint over a coat of primer, complete all as specified and as directed by the Engineer–in–Charge.
Schedule 'A' Part-II (E/M items) Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as perconditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed by the Engineer–in–Charge
Taking down of MCB DB/TPN any type including MCB SP/SPN and making good of wall complete all as specified and directed by the Engineer–in–Charge
M&L Point wiring with 1.5 Sqmm (nominal area) copper conductor FRLS cable (multi-stranded) PVC insulated and unsheathed electric cable 1100 volts drawn through PVC casing and caping of suitable size (as per conductor run) with all fittings and accessories and including PVC insulated unsheathed electric cable 1100 volts 1.5 Sqmm (multi-stranded) copper conductor single core (green colour) as continuous earth wire connected to common earth dolly including 50mm deep box made out of 2nd class hard wood board of suitable size and shape and other boxes for mounting light fittings etc covered with 3mm thick plastic laminated Hylum ISI marked for following complete all as specified and directed by the Engineer–in–Charge Note:- Screw used for fixing TW baords, casing and caping ceiling rose, square blocks etc should be nickel cadmium screws.
(a) One light/fan point controlled by one 5 Amps one way switch
(b) One 3 pin socket outlet 5 Amps on independent board
(c) One 3 pin socket outlet 5 Amps on same board
M&L point wiring for power point with 4.0 sqmm (nominal area) copper conductor FRLS cable ( multi-stranded) PVC insulated and unsheathed cable conductor 1100 Volts drawn through PVC casing capping of suitable size(as per conductor run) with all fittings and accessories and including PVC insulated unsheathed electric cable 1100 volts 2.5 Sqmm (multi-stranded) copper conductor single core (green colour) as continuous earth wire connected to common earth dolly including 50mm deep box made out of 2nd class hard wood board of suitable size and shape and other boxes for mounting light fittings etc covered with 3mm thick plastic laminated Hylum ISI marked for following complete all as specified and directed by Engineer–in–Charge. Note:- Screw used for fixing TW baords, casing and caping ceiling rose, square blocks etc should be nickel cadmium screws.
S&F Switch piano flush button single pole one way 5 Amps, 240 Volts complete all as specfied and directed.
S&F socket outlet 2 in 1, 3pin, 5A(multipurpose) sutable for 2 pin/3 pin plug flush type complete all as specified and directed by the Engineer–in–Charge
S&F switch socket combination 3 pin, 5 Amps, 2in1, flush type (multipurpose) 2 pin / 3 pin plug complete all as specified and directed by the Engineer–in–Charge
S&F switch socket combination 2 in 1, 3 pin, 5/15 Amps, flush type (multipurpose) complete all as specified and directed by the Engineer–in–Charge
S&F Ceiling rose surface backelite ISI marked with 3 terminal including connecting and testing complete all as specified and directed by the Engineer–in–Charge
S&F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed by the Engineer–in–Charge
Supply and fixing Rechargeable LED Bulb energy saver 9 W, B22(220-240 V) 50 hz, 6500k fast charging 2200mAH battery including, white color all as specified and as directed. Make:- CG/Phillips/Havells
S&F surface and wall mounted LED batten with polycarbonate housing and integrated electronic driver tube light fitting 20W, 4 ft long, 220 Volts, and connecting to ceiling rose with three core twisted flexible copper cable of suitable size complete all as specified and directed by the Engineer–in–Charge
S&F LED light fitting 1x10W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size 230V, 50 HZ all as specified and directed.
S&F MCB DB sheet enclosure, Double door type, single pole and neutral 240V with 200 Amp rated bus bar suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete confirming to IP 42/43 without MCB and with enclosure blank plates for unused way suitable for 12 way complete all as specified and directed by the Engineer–in–Charge
Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning all as specified and directed.
Supply and fixing MCB SPN 240V, 10KA 'C' curve 40-63 Amp current carrying capacity in the MCB DB complete with connection testing and commissioning all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm thick burried directly in ground not less than 2.25m deep below normal ground level (with the top edge of the plate not less than 1.50 m below the normal ground level) connected to GI earth wire 4 mm by means of GI bolts, nuts, check nuts and washers of GI all as shown in electrical plate No.3 of SSR Part-I connected to earthing test point with and including necessary excavation and earth work in any strata PCC pit 1:3:6 type C-1, 20mm bore medium grade GI pipe for watering 15mm bore light grade pipe for GI wire protection and funnel including 40mm thick RCC slab cover and testing on completion all as specified and as directed.
S&F GI bracket for street light of 32mm bore GI pipe (medium grade of length 1.5 meter), bend to shape including providing2x pairs of MS flat iron clamp (of suitable size, made out of 40mm x 5mm mild steel flat) with nuts, bolts and washer of suitable size, including applying two coat of red oxide primerand one coat of aluminium paint complete all as specified and directed by the Engineer–in–Charge
Supply and fixing LED bldg security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete making all necessary connection with suitable capacity of 3 core circular cable complete all as specified and directed by the Engineer–in–Charge
Taking out un-serviceable/faulty cable/service connection cable of any grade / type / class of any size for repair / replacement from pole / wall / cable duct under ground trench etc for re-use or removal from site of work all as specified and as directed. (Note- Excavation and earth work shall be measured and paid separately)
Supply, laying, fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 25 sqmm 3.50 core complete all as specified and directed.
Supply, laying, fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 16 sqmm 4 core complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtrs in depth for laying of cable, fixing of stay etc 10 Sqm on plan and n exc 1.5 in depth and getting out in hard/dence soil complete all as specified and directed.
Returing, filling in incl spreading, levelling watering and well remming in layers n.exc 25cm width, complete all as specified and directed.
Removing excavated material to a distance not exc 50m and depositing where directed at level not exc 1.5m above the starting point all as specified and directed
M&L for sand cushioning to underground cables using new dry river sand laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete, punned to 18cm, complete all as specified and directed. Note : Punned thickness of 18cms shall be measured for payment.
M&L Un-reinforced precast factory made concreate cable covers, class LV type-I, with flat size 250x150x40 mm Complete all as specified and directed.
Supply and laying/fixing, GI pipe medium grade 40 mm bore (dia)including all type fittings fixed on walls/to poles with clamps /laid in trenches as cable protection all as specified and directed.
Supply, Install Testing & Commissioning of self supporting totally enclosed double door at front, LT feeder piller compartmentalised design, dust and varmin proof of size 600 mm (Height) x 600 mm (Length) x 450 mm (Width) suitable for 440 Volt 3 phase 4 wire system made out of 3.15 mm thick CRCA sheet and built upon regid frame work having front and rear hinged doors with neoprence rubber gasket including danger plate, earthing strip point and, ventilation louvers at the rear side, bottom detachable gland plate complete with suitable size of Zinc/Cromium plated and nuts, bolts, and washers etc. The pannel shall be synthetic enamelled painted and the control circuit diagram shall be with colour code solid conductor copper 1.5 sqmm cable for easy identification including incomming/outgoing cable holes at the bottom, complete after taking down the old unserviceable one. The Panel shall be emmbeded with 75 x 6 mm MS Angle Iron frame and to be grouted with PCC foundation (1:2:4) type B2 upto a height of 50 cm from normal ground level complete all as specified, directed and comprising of the following. (a) Aluminium bus bar 200 amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. (b) MCB of SPN of 4 pole, 63 amps, 10 KA, with breaking capacity of 25 KA, (Make: L & T/Havells) - 01 No (c) MCB of SP 06 to 32 A, 10 KA (Make: L & T/Havells) - 02 No INDICATING DEVICES (a) LED Indicating lamps for Main Supply indicating R', Y' B' - 01 Set of 3 (b) Digital Voltmeter (Make AE/L&T) - 01 No (c) Current Transformer having Ratio 400/5, 15 VA - 01 Set of 3 (d) Digital Ammeter ( Make(AE/L&T) - 01 No
Supply and fix exhaust fan, steel body AC single Phase 230 volts of size 300m sweep with, blades, and frame and louvers complete with bolts, nuts & washers, embedded in the wall including provisioning of three core flexiable copper cord of size 23/0.0076 of required length from ceiling rose or connector to exhaust fan for connection, complete all as specified and directed by the Engineer–in–Charge
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by the Engineer–in–Charge.
Amount of credit of Rs. 87,543.00 for retrieved materials is mentioned in Schedule of Credit, which will be deducted offline while acceptance of tender. Note :- Tenderers will not quote against this item being a firm amount.
MS SHOWKAT ALIJOO (BID ID -3276487)
M/S GHULAM MOHAMMAD CHATAPA (BID ID -3276535)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .