Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.7 LAccepted-AOC C2 PAIXOMONTIRO APTS BEHIND NSD ALTO DABOLIM VASCO DA GAMA GOA 403 801 | SOUTH GOA | GOA | 403801 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹41.5 L+₹3.7 L (9.73%)Rejected-Finance | L2 | Rejected-Finance Higher bidder | |
| 3 | L3₹43.8 L+₹6.0 L (15.8%)Rejected-Finance FLAT NO 4 VIRGINIA CO OP HOUSING SOCIETY AIR PORT ROAD CHICALIM VASCO DA GAMA GOA 403 711 | SOUTH GOA | GOA | 403711 | L3 | Rejected-Finance Higher bidder | |
| 4 | L4₹44.5 L+₹6.7 L (17.6%)Rejected-Finance | L4 | Rejected-Finance Higher bidder | |
| 5 | L5₹44.6 L+₹6.7 L (17.7%)Rejected-Finance H NO 767 NEAR OLD POST OFFICE NEW VADDEM VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | L5 | Rejected-Finance Higher bidder |
Tender Value
Refer Docs
EMD Value
₹76,000
Closing Date
8 Jun 2021, 6:00 pmClosed
SH A K SINGH SE CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
SPECIAL REPAIRS TO WARDROOM COOK HOUSE DINING HALL AND MB BLOCK P 95 2 AT INS HANSA UNDER GE NW VASCO
2021_MES_438882_1
85420/E8
Open Tender
Civil Works
Item Rate
180 days
CWE NAVY VASCO
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE NW VASCO
₹76,000
Yes
17 Jul 2021
27 Apr 2021
10 Jun 2021
27 Apr 2021
8 Jun 2021
1 Jun 2021
Amount
Schedule 'A' -Part I (B/R Works)
M&L for gunniting exposed concrete surfaces of beam, column and slabs with one layer of complast spray set modified concrete in proportion (50Kg cement 3 to 6mm granite chips 75 kg zonal sand 75 kg and complast 2% by weight of cement water 1 to the following locations :-
(a) 40 mm thick in columns
(b) 30 mm thick in beams
(c) 20 mm thick in slabs
S&F hard drawn steel wire fabric cut to length bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm dia not exceeding 4 Kg/sqm complete all as specified and as directed
M&L for bonding the entire exposed surface with one coat of SBR latex as per manufacturer instructions over wire fabric and surfaces of concrete structure complete all as specified and as directed
Dismantling/Taking out existing hessain base felt of any other existing water proofing treatment from roof including cement plaster and exposing the top surface of RCC slab including removing dust, dirt and washing the roof and removing the dismantled debris to a distance exceeding 200 m but not exceeding 3000m spread and leveled complete all as specified and as directed
M&L for providing 10mm thick plaster in cement mortar 1:4 mixed with 3% integral water proofing compound over roof top surface finished to even & smooth w/o using extra cement complete all as specified and as directed Note :- Integral water proofing compound will be measured and paid separately
M&L for preparation of surface with wire brush and remove loose particle & laitance, wash with clean water, damaged or hollow portion, sharp edges etc. must be cut and removed till the mother slab. Filling the cracks and damaged portion with polymer mortar and allow it to cure for 24 hrs. Brush apply the 1st Priming coat of approved make on prepared concrete/plastered surface by diluting 2 parts of Prime seal with 1 (one) part of water and allow to dry for 04 (four) hours. Apply the first coat of waterproofing coating of approved make without any dilution at the rate of 2 Sqm per liter over the primed surface. On the wet surface of 1st coat overlay a open-woven fibre glass mesh, min 40 GSM of size 2mm x 2mm and allow it to soak completely. Immediately apply the second coat with a roller, to ensure complete coverage of the fibre mesh. Apply the third coat after 6 to 8 hrs once the second coat is dry. Drying time between coats will be 6 to 8 hours all as directed and as per manufacturers instructions.
Taking down cement plaster on brick or stone walls, ceilings etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed
M&L for rendering 15 mm thick on block masonry surfaces or other than fair faces of brick work in cement mortar 1:4. finished to even and smooth without using extra cement complete all as specified and as directed
M&L for rendering 15 mm thick cement plaster on concrete solid block walls in two coats first coat of 10 mm in cement mortar 1:4 & 2nd coat of 5mm in cement mortar 1:4 mixed with 3% integral water proofing compound finished to even & smooth w/o using extra cement complete all as specified and as directed Note :- Integral water proofing liquid will be measured and paid separately.
M&L for rendering 5 mm thick cement plaster on ceiling in cement mortar 1:3 mixed with 3% integral water proofing compound finished to even & smooth without using extra cement separately complete all as specified and as directed Note :- Integral water proofing liquid will be measured and paid separately.
Supply only water proofing compound complete all as specified and as directed
M&L for preparing new plastered ceiling surfaces and applying two coat of oil bound distemper over chalk whiting, on plastered surfaces, preparatory to distempering, after applying 3mm thick wall care putty on ceiling complete all as specified and as directed
M&L for preparing new plastered wall surfaces and applying two coat of oil bound distemper over chalk whiting, on plastered surfaces, preparatory to distempering, after applying 3mm thick wall care putty on wall complete all as specified and as directed
M&L for complete removal of existing treatment and Preparing old plastered ceiling surfaces and applying two coat of oil bound distemper over chalk whiting, on plastered surfaces, preparatory to distempering, after applying 3mm thick wall care putty on ceiling complete all as specified and as directed
M&L for complete removal of existing treatment and Preparing old plastered wall surfaces and applying two coat of oil bound distemper over chalk whiting, on plastered surfaces, preparatory to distempering, after applying 3mm thick wall care putty on wall complete all as specified and as directed
M&L for preparation of new plastered surface and applying two coats of weather proof high glove antifungal paint on external surface with suitable primer complete all as specified and as directed
M&L for complete removal of existing treatment and preparing old plastered wall surfaces and applying two coats of weather proof high glove antifungal paint on external surface with suitable primer complete all as specified and as directed
Taking down chowkats or frames not exceeding 1.5 sq m without taking off shutters from the frames each all as specified and as directed.
Taking down chowkats or frames exceeding 1.5 sq m but not exceeding 4 sqm without taking off shutters from the frames each all as specified and as directed.
S&F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam colour PVC sheet on back face, including 20 mm thick PVC lining around all 4 edges of shutter, supplying & fixing in frame at site as per specification & drawing complete all as specified and as directed.
S&F Factory made 100% solid wood plastic(WPC) Decorative Door Frame, single rebate of size 95mm x 45mm made from wood plastic composite(single extruded process) material with density 780 Kg/Cum complete all as specified and as directed.
S&F Butt hinges medium weight stainless steel of 100mm size complete all as specified and as directed.
S&F Extruded stainless steel of 100 mm grip size complete all as specified and as directed.
S&F Stainless steel, barrel tower bolts of extruded section of 150mm size complete all as specified and as directed.
S&F Stainless steel sliding door bolt of size 300 mm with hasp and staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolt and sliding bolt or extruded section or cast aluminum alloy complete all as specified and as directed.
S&F Toughened glass door with toughened glass of 12 mm thick fixed with floor spring, hold & open function, 300 mm long stainless steel pull handles, locking arrangements including all necessary fittings and frameworks complete all as specified and as directed. Note: Design shall be Blumcraft's series 1301 or 640c or equivalent as approved by GE.
S&F Frosted toughened glass door with toughened glass of 12 mm thick fixed with floor spring, hold & open function, 300 mm long stainless steel pull handles, locking arrangements including all necessary fittings and frameworks complete all as specified and as directed. Note: Design shall be Blumcraft's series 1301 or 640c or equivalent as approved by GE.
S&F Aluminium (extruded section body) door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and as directed.
Taking up or down steel water tubing of 20 mm bore and connections including cleaning for refixing or removing to store complete all as specified and as directed.
Taking up or down steel water tubing of 25 mm bore and connections including cleaning for refixing or removing to store complete all as specified and as directed.
Supplying and laying of CPVC pipes of 20 mm dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed.
Supplying and laying of CPVC pipes of 25 mm dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed.
S&F in repair PVC Connections 15mm size with PTMT nuts of length 450mm complete all as specified and as directed.
S&F in repair two way bib cock with wall flange complete all as specified and as directed.
S&F Powder coated aluminium window/ventilators shutter including frame, any type sliding or openable with frame, & other similar work etc. fabricated by using the approved standard section including necessary arrangements to receive 4mm thick glass or wire mesh with aluminium channel beading & stainless steel screws including the cost of rubber gasket/rubber beading etc. complete including necessary handles, roller wheels, hinges etc complete all as specified and as directed. Note :- Weight of aluminium section shall be measured exclusive of all fittings fixtures, hinges, handle, bolts, rubber gasket/rubber beading and locking arrangements.
S&F Pillar taps fancy type of 15 mm dia, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and as directed.
Dismantling boarding, any description, fixed in any position with Screws complete all as specified and as directed
S&F 18 mm thick single side prelaminated woodgrain solid PVC sheet suitablely fixed in shelves; Partitions and shelves of built-in cupboards, almirahs, book cases, toilet boxes, racks, pelmets and similar work with all fittings and locking arrangements as per direction and specifications complete all as specified and as directed
Schedule 'A' -Part II (E/M Works)
Taking down carefully any type of copper/aluminium point wiring (light, fan, socket or power complete including conduits/casing capping with fittings such as switches. ceiling roses, pendents regulators ,bells.. sockets, tube light fittings etc, removing the materials/debris and making good the disturbed surface of walls & floors etc to match with the original existing finish complete all as specified and as directed
M & L for one point wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LSH conforming to IS 694 of size 1.5 Sq mm single core, including one No 1.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LSH as continuous earth wire drawn in and including PVC conduit medium grade of as required size (not less than 20 mm dia) ISI marked medium grade with all accessories of same grade fixed concealed in wall including provision of modular metal flush box modular cover plate with frame top cover for housing switch, socket, fan regulators etc for one light point controlled by one 5 Amp switch one way complete all as specified and as directed
All as per Item No.40 here in before but for one fan/exhaust fan point controlled by one 5 Amp switch one way complete all as specified and as directed
All as per Item No.40 here in before but for one 3/5 pin,5 Amp switch socket outlet on the independent board complete all as specified and as directed
All as per Item No.40 here in before but for one 3/5 pin,5 Amp switch socket outlet on the same board complete all as specified and as directed
M&L for point wiring with PVC insulated un-sheathed cable with stranded copper conductor FR- LSH conforming to IS: 694 of size 2.5 Sq mm single core, including one No. 2.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LSH as continuous earth wire drawn in and including PVC conduit medium grade of as required size (not less than 20 mm in width) ISI marked medium duty, with all accessories of same grade, fixed concealed in wall including provision of modular metal flush box modular cover plate with frame top cover for housing mounting switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type on the independent board complete all as specified and as directed
Taking down unserviceable any type of copper/aluminium sub main wiring of any type/size/core/ type complete including conduits/casing capping etc, removing the materials/debris and making good the disturbed surfaces of walls, floors and ceilings etc to match with the original existing finish complete all as specified and as directed
M & L for sub main wiring with two runs of single core 10 Sqmm FR-LSH Copper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & including non- metallic rigid PVC casing & capping (double interlock type) of suitable width medium duty with all accessories such as Tees, elbows, junction boxes etc. as required fixed on wall along with one run of 10 Sqmm single core PVC FR-LSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/distribution board and testing on completion etc complete all as specified and as directed Note:Three runs of 10 sqmm cable and one run of PVC casing and capping shall be considered as one unit length
M & L for sub main wiring with two runs of single core 6 Sqmm FR-LSH Copper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & including non- metallic rigid PVC casing & capping (double interlock type) of suitable width medium duty with all accessories such as Tees, elbows, junction boxes etc. as required fixed on wall along with one run of 6 Sqmm single core PVC FR-LSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/distribution board and testing on completion etc complete all as specified and as directed Note:Three runs of 6 sqmm cable and one run of PVC casing and capping shall be considered as one unit length
M & L for sub main wiring with two runs of single core 4 Sqmm FR-LSH Copper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & including non- metallic rigid PVC casing & capping (double interlock type) of suitable width medium duty with all accessories such as Tees, elbows, junction boxes etc. as required fixed on wall along with one run of 4 Sqmm single core PVC FR-LSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/distribution board and testing on completion etc complete all as specified and as directed Note:Three runs of 4 sqmm cable and one run of PVC casing and capping shall be considered as one unit length
S & F in repairs modular switch single pole one way 6 A, 240 V complete all as specified and as directed
S & F in repairs modular switch single pole one way 16 A, 240 V complete all as specified and as directed
S & F in repairs modular socket outlet 2 in 1, 6 Amp 240 volts, complete all as specified and as directed
S & F in repairs modular socket outlet 5A/16A 5 in 1 3 pin flush type universal, 240 volts complete all as specified and as directed
S & F in repairs ceiling rose, 3 phase/ PVC / polycarbonate, isolated body complete all as specified and as directed.
S&F in repairs modular fan step regulator, 120W-2 module complete all as specified and as directed.
S&F in repairs white cover plate with frame 2 module complete all as specified and as directed
S&F White Cover plate with frame 3 module complete all as specified and as directed
S&F White Cover plate with frame 6 module complete all as specified and as directed
S&F White Cover plate with frame 8 module complete all as specified and as directed
S&F Metal flush box 2 module complete all as specified and as directed
S&F Metal flush box 3 module complete all as specified and as directed
S&F Metal flush box 6/8 module complete all as specified and as directed
Taking down old unserviceable panel of any size from cook house entrance area complete all as specified and as directed
Taking down unserviceable any type of Main Switch, DB's including MCB including wooden/GI/MS sheet board etc and removing from site and making good the disturbed surface of wall etc complete all as specified and as directed.
S&F in repairs single pole and neutral enclosure with a 2 pin and earth plug and socket complete with one MCB SP 20 Amps, 10 KA 'C 'series, 240 Volts complete all as specified and as directed.
S & F MCCB DB VTPN, 12 way, (MCCB + 12+12+12 way O/G) double door, vertical type, metal door IP 54, with provision one MCCB of 200 amps breaking capacity 25 KA, 4 pole without MCB complete all as specified and as directed
S&F in repairs MCCB of 200 A breaking capacity 25 KA, 4 pole thermal magnetic release, compact type suitable for MCCB DB Vertical type as incoming in the existing DB's complete all as specified and as directed
S & F Vertical MCB DB's VTPN 4 Way sheet steel, phospetised, powder coated with 200 Amps rated bas bar double door, 415 Volt complete all as specified and as directed
S & F MCB TPN 63 Amps 415 volts complete all as specified and as directed
S & F in repairs MCB TP 63 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified and as directed
S&F in repairs MCB SP 06 to 32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified and as directed
S & F DB mounted MCB type indicating lamp Three phase (Red+Yellow+Blue) complete all as specified and as directed
M&L for earthing complete with copper earth plate electrode 600 x 600 x 3.15 mm thick buried directly in ground earth pit not less than 2.25 m deep below normal ground level with top edge of the plate not less than 1.5 m below normal ground level connected to copper strip Size 25 x 3 mm thick by mean of nuts/bolts check nuts and washers of brass as shown in electrical plate No.3 of SSR part including necessary excavation and earth work. Gt Pipe 15 mm bore light grade for watering with Funnel wire mesh and refilling of soil shall be provided with Gl pipe light grade 25 mm dia up to 7.5 m from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common sall etc & earth work in any strata PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick precast RCC cover slab 1:2: 4 type B with 5 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and directed by Engineer-in-charge Note: GI earth wire upto 7.5 RM is included in the unit rate quoted
Taking down carefully ceiling fans of size 1200 mm sweep at any height of any sweep/make/model after disconnecting electric connection and dismantling and opening the body of ceiling fan and examine for repairs including servicing, overhauling, greasing etc and cleaning the complete body both internal & external parts with cleaning agent and renewal of minor spare parts such as split pins, cater pins, coupling boll, capacitor holder, terminal adaptor, screws, nuts, spring washers for blade/body etc and replacement of accessories such as ball bearings, gun metal bushes, capacitor, canopy top & bottom, shackle clip assembly and assembling of all parts and painting with two coat of synthetic enamel paint by using electric spray machine similar to match with existing colour including hanging and fixing back in existing location and connecting of electrical connections and testing for its satisfactory performance after renovation of bldg complete all as specified and as directed Note : After taking down fan will be in contractor custody to keep in safe condition
S&F Exhaust fan 300 mm sweep. single phase 230 volts. metallic body complete with all accessories including fixing arrangement with louvers in existing hole by providing rugged bolts embedded in wall and making good the disturbed portion and necessary cable connections including removing of old unserviceable fans from existing site and deposited to MES store complete all as specified and as directed
S & F in repairs energy efficient surface Mounted LED Luminaire 40 watts 4 feet long, with acrylic cover complete with all accessories including necessary two core copper wire for connection from ceiling rose to connector of approx length 0.75 m complete all as specified and as directed
S&F in repairs LED mirror light fitting 1 x 12 Watts WW. operating voltage 140 V to 265 V indoor decorative aluminum die cast IP 42 complete with all accessories internally pre- wired and including connecting up with twin core twisted flexible copper conductor cable with suitable sizes complete all as specified and as directed
S & F in repairs surface mounting 2'X2', 43 watts 230 V 50 HZ LED luminaire to enhance the delight of Each occupants with comfortable experience though its classic design & glare free soft illumination complete all as specified and as directed
S&F LED flood light fitting 240 watts made in pressure die cast aluminium housing and reflector and enclosed with toughened glass with IP66 protection complete with all accessories such as LED's and electronic driver internally prewired including necessary fixing arrangement on PCC pole by providing MS angle on bracket 50x50x6mm of adequate length as per site requirement with MS flat iron clamp 32x6 mm necessary nuts bolts and washers etc and making cable connection complete all as specified and as directed
S&F in repairs LED post top lamp with de cast aluminium body and with white powder coated aluminium reflector and IP:65 protection 40 watts capacity complete all as specified and as directed
S&F in repairs LED wall light up and down light outdoor type 2X6 watt 230 V 50 HZ IP 65 compete all as specified and as directed
K M SUBHANAIAH
M/S jvsr constructions
CVs CONSTRUCTIONS
M/S DUBAL CONSTRUCTION
M/s RAJ CONSTRUCTION
M/S Kartik Enterprises
Super Construction
pk janardhanan
SACHIN CONSTRUCTIONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .