Loading…
Loading…
Tender Value
₹1.0 Cr
EMD Value
₹2.1 L
Closing Date
1 Sept 2026, 2:00 pm6d left
EE/SWSD
Office of the Executive Engineer Siliguri W/s Division PHE Dte.
DAY TO DAY OPERATION AND MAINTENANCE OF 12 MGD (55.02 MLD) WATER TREATMENT PLANT AT FULBARI, P.S. RAJGANJ, DIST. JALPAIGURI FOR SILIGURI COMPREHENSIVE WATER SUPPLY SCHEME UNDER SILIGURI W/S DIVISION, P.H.E. DTE.,FOR 365 DAYS
2026_PHED_1035262_1
PHE/SWSD/EE/NIeT- 04 of 2026-27 (SL.NO. 01 )
Open Tender
CIVIL WORKS
Percentage
365 days
SILIGURI
As per BOQ
4 documents required · 4 mandatory
₹2.1 L
Yes
3 Aug 2026
3 Aug 2026
3 Sept 2026
3 Aug 2026
1 Sept 2026
3 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Operation of water treatment plant commencing from Inlet chanel of raw water with continuous supervision of the functional aspects of the following individual units including routine maintenance of the mechanical installations as per instruction and satisfactions of the Engineer-in-charge 8 hours X 2 shifts in a day any time depending upon availability of power (normally between 6.00 A.M. to 10.00 P.M.) In terms with following modules: | - | - | - | - |
| 2 | (a) (i) Running of flash mixer along with lubrication and minor re-alignment (if necessary including re-placement of fuse wire and all other minor maintenance of mechanical installations for 2 nos. flash mixers. | - | - | - | - |
| 3 | (a) (ii) Running of clarifier bridges, driving motors gear pinion etc. along with lubrication and minor re-alignment, re-placement of fuse wires and minor maintenance of electrical and mechanical installations for 2 nos. clarifiers. | - | - | - | - |
| 4 | (a) (iii) Running of flocculator drive motor, gear pinion etc. along with lubrication and all other maintenance of mechanical / electrical installations for all the flocculators. | - | - | - | - |
| 5 | (b) Operation of alum tank agitator paddles of 3 nos. alum solution tanks with supervision of the functional aspects of the following units :(8 hours X 2 shifts in a day any time depending upon availability of power (normally between 6.00 A.M. to 10.00 P.M.) | - | - | - | - |
| 6 | (b) (i) Running of alum agitator paddles, drive motors, reduction gear pinion shafts etc. as necessary along with lubrication and minor re-alignment including replacement of fuse wires and all other maintenance of mechanical / electrical installations for all the 3 nos. agitators. | - | - | - | - |
| 7 | (b) (ii) Loading of alum cakes from the alum storage godown to the alum solution tanks by the help of alum hoist / manually along with lubrication and minor maintenance of alum hoist mechanical and electrical parts. | - | - | - | - |
| 8 | (c) Operation of the chlorinator and chlorine booster pump with continuous supervision of the functional aspects of each individual units including routine maintenance of mechanical and electrical installations as per instruction and satisfaction of the Engineer-in-charge including hypochlorite dosing if necessary.(8 hours X 2 shifts in a day any time depending upon availability of power (normally between 6.00 A.M. to 10.00 P.M.) | - | - | - | - |
| 9 | (c) (i) Running of chlorinator with its ancilliaries including running booster pumps for 2 nos. chlorinators or running of hypochlorite dosing system along with lubrication and all other maintenance of mechanical / electrical installation for all the chlorinators, booster pumps, hypochlorite dosing system. | - | - | - | - |
| 10 | © (ii) Handling & changing of empty chlorine cylinder with skilled personnel keeping the same to the chlorine storage godown including minor maintenance of mechanical / electrical installations and proper maintenance of chlorine leak detector. | - | - | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.57 MB
Tendernotice_2.pdf
PDF • 0.96 MB
Tendernotice_3.pdf
PDF • 0.81 MB
Tendernotice_4.pdf
PDF • 0.29 MB
Tendernotice_5.pdf
PDF • 0.30 MB
Tendernotice_6.pdf
PDF • 0.55 MB
Tendernotice_7.pdf
PDF • 0.39 MB
Tendernotice_8.pdf
PDF • 3.72 MB
BOQ_2542980.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].