| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC | ₹1.1 Cr | L1 | Accepted-AOC Being Lowest Bidder |
| 2 | L2₹1.4 Cr+₹21.4 L (18.8%)Rejected-Finance TP 117 2ND FLOOR MAURYA ENCLAVE PITAMPURA DELHI 110034 | DELHI | DELHI | DELHI | 110034 | ₹1.4 Cr+₹21.4 L (18.8%) | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹1.4 Cr+₹23.2 L (20.3%)Rejected-Finance | ₹1.4 Cr+₹23.2 L (20.3%) | L3 | Rejected-Finance Not being lowest |
| Sl No | Description | Qty | Unit | GLIBS CONSTRUCTION L2 | M/S MG GROUP L3 | Ashish Sehgal and Co. L1 |
|---|---|---|---|---|---|---|
| 1.00 | Material and Labour for complete removal of any type of existing roof treatment including bedding layer of concrete/mud any thickness in cement mortar and including carefully removal of solar plates and refixing the same at same place after the execution and disposed of retrieved material outside MOD land/low lying area complete all as specified and as directed. | 1,320 | Sqm | 20 ₹26,400 | 400 ₹5,28,000 | 10 ₹13,200 Lowest |
| 2.00 | Material and Labour for cement concrete 1 : 2 : 4 type B-1 (using 20 mm graded stone aggregate) as in roof padding 50mm thick average over roof slabs for providing proper slope with and including mixing of WPC liquid 150 ml per bag of cement complete all as specified.
Note : WPC will be measured and paid separately. | 66 | Cum | 3,500 ₹2,31,000 | 4,600 ₹3,03,600 | 2,000 ₹1,32,000 Lowest |
| 3.00 | Cleaning and preparation of the surface to receive Fosroc Proofex ORG or its equivalent in approved make water proofing system shall be a sound base, any crack shall be treated with Cementous repair mortar of Fosroc Renderoc CS or epoxy crack filling mortar by proper grooving arrangement all as directed by engr - in charge. | 1,320 | Sqm | 150 ₹1,98,000 | 100 ₹1,32,000 Lowest | 100 ₹1,32,000 Lowest |
| 4.00 | Providing and laying / fixing TPO membrane of nonflammable waterproofing on roof which shall be a 1.5mm thick loose laid TPO membrane layers overlapped to achieve a minimum weld of 110mm, Hot air welding can be either hand applied or by means of automatic machines and the rolls either end are overlapped with layers of non-woven geotextilefiber, the separation layer provided to prevent the mechanical abrasion and cushioning between the Fosroc Proofex ORG membrane or its equivalent in approved make and the concrete substructure, the termination of Fosroc Proofex ORG or its equivalent in approved make by aluminium strip anchoring.
Note: Work shall be executed by authorised applicator with prior experience of more than 5 years in applying similar system. | 1,320 | Sqm | 1,600 ₹21,12,000 | 1,800 ₹23,76,000 | 1,550 ₹20,46,000 Lowest |
| 5.00 | Material and Labour for dismantling loose concrete cover of RCC slab, ceiling , columns, beams, chajja, balconies, staircase and as directed, roughening and cleaning concrete surfaces with steel wire brushes, removing of rust from existing steel surfaces with rust removers of SIKKA rest off 100 applied two coast @0.15kg/Sqm per coat of steel surface and cleaning all rust with steel wire brush and washed with water and allowed to dry incl Supply and Fixing welded fabric GI wire mesh or wire , size not less than 75 x 75 mm and 3 mm dia as reinforcement to concrete. After placing the additional re-inforcement, all concrete surfaces shall be thoroughly scrubbed with brushes, washed with water and allowed to dry to this surface , apply chemical polycrete admixture at the rate not less than 2% by weight of cement and providing minimum 30 mm thick (average thickness) guniting mix (using 1 part of ordinary Portland cement 53 grade and 2 parts of ghaggar sand mixed with adhesive/admixture at the rate as directed) with a pressure of 2.2 to 2.5 kg per sqm by gunniting machine and surfaces finished even and fair including necessary padding, shuttering form work etc and finally applying 5 mm thick cement plaster in CM 1:3 complete all as specified and directed by Engineer-in-Charge. | 350 | Sqm | 800 ₹2,80,000 | 900 ₹3,15,000 | 650 ₹2,27,500 Lowest |
| 6.00 | Taking down chowkats or frames with shutters (with out taking off shutters from the frames) not exc 1.5 Sqm each incl removing complete all as specified and directed by Engr-In-Charge. | 100 | Each | 150 ₹15,000 | 100 ₹10,000 Lowest | 120 ₹12,000 |
| 7.00 | Supply and Fixing aluminium chequered grill of anodized section of mesh 100x100mm or 80x80mm of 4/ 8/6/mm dia of bar fixed to frame with 20x20mm aluminium flat section with screw complete all as specified and as directed. | 180 | Sqm | 1,800 ₹3,24,000 | 1,500 ₹2,70,000 | 960 ₹1,72,800 Lowest |
| 8.00 | Material and Labour for 16-18mm thick Granite slab on top of cooking platform, bar counter window sill and similar work including cutting polishing rounding on edge etc machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone over and including 15mm thick screed bed in CM 1:4. including grinding and polishing complete all as specified and directed by Engr-In-Charge | 33 | Sqm | 3,000 ₹99,000 | 2,600 ₹85,800 | 2,200 ₹72,600 Lowest |
| 9.00 | Supply and Fixing for powder coated (minimum thickness of powder coating 50 micron) aluminium anodized three track sliding window with two or more shutter with 5 mm thick plane glass, one shutter of stainless steel mosquito proofing with good quality bearing ,handle lock,etc rubber beading and glazing clips etc using following sections as given in 'JINDAL' catalogue etc as specified as per manufacturer instructions with the following size, complete all as specified and directed by Engr-in-Charge.
Note : (1)Glass and wire not measured and paid separately however cost of all other connected accessories deemed included in unit rate. (2) faces of windows jamb should be given fair finish before fixing the window as per requirement of site | 180 | Sqm | 5,700 ₹10,26,000 Lowest | 6,500 ₹11,70,000 | 8,000 ₹14,40,000 |
| 10.00 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engr in Charge. | 86 | Sqm | 20 ₹1,720 | 50 ₹4,300 | 10 ₹860 Lowest |
Tender Value
₹1.5 Cr
EMD Value
₹2.2 L
Closing Date
5 May 2026, 6:00 pmClosed
CWE (AF) Palam
CWE (AF) Palam, delhi Cantt-10
ADDN/ALTN TO AIRMEN LIVING IN ACCN AT HQ WAC (U) AT SUBROTO PARK UNDER GE (AF) SUBROTO PARK, DELHI CANTT-10
2026_MES_759272_1
CWE/PM/SP-02/2026-27
Open Tender
Civil Works
Item Rate
365 days
Subroto Park
Please refer Tender documents.
11 documents required · 11 mandatory
₹1,000
GE (AF) Subroto Park
₹2.2 L
Yes
14 Jul 2026
6 Apr 2026
12 May 2026
6 Apr 2026
5 May 2026
28 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Material and Labour for complete removal of existing any type of existing roof treatment including bedding layer of concrete/mud any thickness in cement mortar and including carefully removal of solar plates and refixing the same at same place after the execution of work disposed from MD land complete all as specified and as directed. | - | Sqm | - | - |
| - | Material and Labour for cement concrete 1 : 2 : 4 type B-1 (using 20 mm graded stone aggregate) laid as in padding 50mm thick average over roof slabs for providing proper slope including finishing surface even and smooth without unsing extra cement with admixture of WPC liquid 150 ml per bag of cement complete all as specified. Note : WPC will be measured and paid separately. | - | Cum | - | - |
| - | Cleaning and preparation of the surface to receive Fosroc Proofex ORG or its equivalent in approved make water proofing system shall be a sound base, any crack shall be treated with cementious repair mortar of Fosroc Renderoc CS or epoxy crack filling mortar by proper grooving arrangement all as directed by engr - in charge. | - | Sqm | - | - |
| - | Providing and laying / fixing TPO membrane of nonflammable waterproofing of roof which shall be a 1.5mm thick loose laid TPO membrane layers overlapped to achieve a minimum weld of 110mm, Hot air welding can be either handapplied or by means of automatic machines and the rolls either end are overlapped with layers of non-woven geotextilefiber, the separation layer provided to prevent the mechanical abrasion and cushioning between the Fosroc Proofex ORG membrane or its equivalent in approved make and the concrete substructure, the termination of Fosroc Proofex ORG or its equivalent in approved make by aluminium strip anchoring.
Note: Work shall be executed by authorised applicator with prior experience of more than 5 years in applying similar system. | - | Sqm | - | - |
| - | Material and Labour for dismantling loose concrete cover of RCC slab, ceiling , columns, beams,chajja, balconies, staircase and as direceted, roughening and cleaning concrete surfaces with steel wire brushes, removing of rust from existing steel surfaces with rust removers of SIKKA restoff 100 applied two coast @0.15kg/Sqm per coat of steel surface and cleaning all rust with steel wire brush and washed with water and allowed to dry incl Supply and Fixing welded fabric GI wire mesh or wire , size not less than 75 x 75 mm and 3 mm dia as reinforcement to concrete. After placing the additional re-inforcement, all concrete surfaces shall be throughly scurbbed with brushes, washed with water and allowed to dry to this surface , apply chenmical policrete admixture at the rate not less than 2% by weight of cement and providing minimum 30 mm thick (average thickness) guniting mix (using 1 part of oridinary poartland cement 53 grade and 2 parts of ghaggar sand mixed with adhesive/admixture at the rate as directed) with a pressure of 2.2 to 2.5 kg per sqm by guniting machine and surfaces finished even and fair including necessary padding, shuttering form work etc and finally applying 5 mm thick cement plaster in CM 1:3 complete all as specified and directed by Engineer-in-Charge. | - | Sqm | - | - |
| - | Taking down chowkats or frames with shutters (with out taking off shutters from the frames) not exc 1.5 Sqm each incl removing complete all as specified and directed by Engr-In-Charge. | - | Each | - | - |
| - | Supply and Fixing aluminium chequered grill of anodized section pf mesh100x100mm or 80x80mm of 4/ 8/6/mm dia of bar fixed to frame with 20x20mm aluminium flat section with screw complete all as specified and as directed. | - | Sqm | - | - |
| - | Material and Labour for 16-18mm thick Granite slab on top of cooking plateform, bar counter window sill and simillar work including cutting polishing rounding on edge etc machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone over and including 15mm thick screed bed in CM 1:4. including grinding and polishing complete all as specified and directed by Engr-In-Charge. | - | Sqm | - | - |
| - | Supply and Fixing for powder coated (minimum thickness of powder coating 50 micron) aluminum anodized three track slinding window with two or more shutter with 5 mm thick plane glass, one shutter of stainless steel mosquito proofing with good quality bearing ,handle lock,etc rubber beading and glazing clips etc using following sections as given in 'JINDAL' catlogue etc as specified as per manufacturer instructions with the following size, complete all as specified and directed by Engr-in-Charge.
Note : (1)Glass and wire not measured and paid separately however cost of all other connected accessories deemed included in unit rate. (2) faces of windows jamb should be given fair finish before fixing the window as per requirement of site | - | Sqm | - | - |
| - | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engr in Charge. | - | Sqm | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.20 MB
BOQ_850453.xls
BOQ • 0.33 MB
Tendersp02.pdf
Tender Documents • 0.92 MB
Credit02.pdf
Tender Documents • 0.15 MB
CorrgnNo02date.pdf
PDF • 0.09 MB
CorrgnNo01date.pdf
PDF • 0.09 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .