Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹19.9 L+₹1.1 L (5.84%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹20.0 L+₹1.2 L (6.10%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹20.7 L+₹1.9 L (9.83%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹21.2 L+₹2.4 L (12.5%)Rejected-AOC NO 354 2ND CROSS VARADARAJNAGAR VIDYARANYAPURA POST BANGALORE 5600 097 | 5600097 | L5 | Rejected-AOC L5 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
28 Jul 2021, 6:00 pmClosed
GE (AF) Yelahanka
GE (AF) Yelahanka Bangalore - 63
REPAIRS/REPLACEMENT OF LT PANEL BOARD, MCCBs,SERVICING OF LT ACB AND LT OH LINE/UG CABLES AND ALLIED WORKS AT AFS STATION YELAHANKA
2021_MES_455794_1
8889/E8
Open Tender
Civil Works
Item Rate
180 days
AFS Yelahanka
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Yelahanka
₹50,000
Yes
4 Oct 2021
29 Jun 2021
30 Jul 2021
29 Jun 2021
28 Jul 2021
15 Jul 2021
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc., and getting out in hard/dense soil all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in not exceeding 25 cm thick complete all as specified and directed.
Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point as directed.
Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 with peak, size250 mm x 150mm x 40mm all as specified and as directed.
Supply, lay, spread in trenches 'M' sand including spreading, levelling, punning for cushioning of cable all as specified and as directed. Note : For measurement purpose only punned thickness shall be considered.
Supply and laying in trenches, LT underground cable of size 6 Sqmm 2 core XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands,jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall including taking down complete all as directed by Eng-in-cahrge.
All as per item No 6 here-in-before but 10sqmm 4 core
All as per item No 6 here-in-before but 16 Sqmm 4 core
All as per item No 6 here-in-before but 25 Sqmm 3.5 core
All as per item No 6 here-in-before but 35 Sqmm 3.5 core
All as per item No 6 here-in-before but 50 Sqmm 3.5 core
All as per item No 6 here-in-before but 70 Sqmm 3.5 core
All as per item No 6 here-in-before but 95 Sqmm 3.5 core
All as per item No 6 here-in-before but 120 Sqmm 3.5 core
All as per item No 6 here-in-before but 240 Sqmm 3.5 core Note : For Sl No 6 to 15, necessary excavation and connected items shall be measured and paid separately under respective items of this schedule.
Boring of holes under roof, pavement, hardstanding by trenchless technology using ultrasound technique and necessary machine including GI pipe of 50/80/100mm dia suitable for 0.4mpa working pressure.
Supply and laying GI tubing light grade 50mm dia in trenches/fixing on pole /wall/crossing in drain etc.for protection of UG cable
Supply and laying GI tubing light grade 80mm dia in trenches/fixing on pole /wall/crossing in drain etc.for protection of UG cable
S & F danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for LT, 20x15cm size including taking down old unserviceable one.
Restringing of LT overhead lines conductor of any size (Conductor will be measured separately, if required)
Supply and fix in repair 40 to 100 Amp rating, 240V, 10KA 'C' curve miniature circuit breaker (MCB) of four pole in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair 32 Amps rating, 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of Single Pole and Neutral, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed by Engr-in-Charge.
Supply and fixing of PVC spacers for 4 wire LT 1100 Volts grade overhead line all as directed.
Supply and fixing of PVC spacers for 2 wire LT 1100 Volts grade overhead line all as directed.
Supply and fix cable route indicator made out of 3 mm thick MS sheet of size 20 cm x 15 cm duly painted with two coats black paint over a coat of red oxide primer and writing cable direction, capacity, size of cable with white paint, mounted on angle iron 40x40x3 mm, angle height 45 cm, (30cm below ground level) with PCC 20cmx20cmx15cm all as specified and as directed by Engineer- in- charge.
Supply, installation and commmissioning in repair LT out door loop in loop out terminal box with sloping canopy of size 600x450x250mm made out of 3 mm thick CRCA sheet duly painted with two coars of syntehtic enamel paint over a coat of rex oxide, front and rear hinged doors mounted on 40x40x6 mm MS angle iron frame 90 cms height erected in ground with PCC foundation 1:4;8 with 40mm stone aggregate including supply and fixing insulated aluminium bus bar of size 50x 6mm for three phase and neutral 200mm length respectively mounted on insulators and terminating with suitable cable with glands and provision of one MCCB 63 Amps 4 pole ,415 Amps, 50 Hz of breaking capacity 16 KA as incomer including taking down old terminal boxes complete all as specified and directed by Engr-in-Charge.
Supply and fix bus bar box of size 450x300x500mm fabricated by 3 mm thick MS sheet outdoor type,mounted/fixed on angle Iron frame of MS equal angle size 40x40x6mm of height 0.90 mtr and fixed in ground complete box with dust/vermin proof including aluminium bus bar flat of size 50x6 mm fixed as bus bar over the insulators, sleeved for three phase and neutral and spray painting the box with two coats of enamel paint over a coat of metal primer including necessary excavation, PCC for fixing the box complete all as specified and directed by Engr-in-Charge.
Supply and jointing straight through joint outdoor type 1100 volts grade heat shrinkable type suitable for 3.5x 25 sqmm to 3.5x 70 sqmm LT XLPE cable and testing after jointing complete all as specified and as directed by Engr-in-charge.
Supply and jointing straight through joint outdoor type 1100 volts grade heat shrinkable type suitable for3.5x 95 sqmm to 3.5x 120 sqmm LT XLPE cable and testing after jointing complete all as specified and as directed by Engr-in-charge.
Preparing old faded painted surfaces of 9 m/11 m long steel tubular/RCC/PCC/Rail pole complete including all accessories such as cross arms bracings, brackets etc and paints with two coats of Aluminium paint of approved colour including writing pole number with paint same as existing earlier all as directed.
Preparing of old faded paint surface and painting with paint to existing LT PCC/RCC/steel tubular poles of size 9m/11 mtr long upto the height of 1.2m from the bottom with approved white and blue colour alternatively including numbering of poles same as existing earlier all as directed
Supply only CTs suitable for existing LT panel board of capacity 400 to 630 Amps all as specified and as directed.
Supply only CTs suitable for existing LT panel board of capacity 250 to 320 Amps Amps all as specified and as directed.
Supply only CTs suitable for existing LT panel board of capacity 63 to 200 Amps Amps all as specified and as directed.
Supply only LED indicator lamps (R Y B ) suitable for existing panel all as pecified and directed.
Supply and fix MCCB 400 Amps, 4 pole 415 Volts,50 Hz,36 KA adjustable thermal and magnetic based type all as specified and directed.
All as per item no 38 above but 200 Amps 4 pole 36 KA adjustable and magnetic based type
All as per item no. 38 above but 100 Amps 4 pole 25KA adjustable type
All as per item no. 38 above but 63 Amps 4 pole 16KA adjustable type
Supply only digital ammeter 100amps range suitable for mounting existing panel all as specified and directed
Supply only digital voltmeter 500 Volts range suitable for mounting existing panel all as specified and directed
M & L for Earthing complete with galvanised earth plate electrode of size 600x600x6 mm thick burried directly in ground earth pit not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 mtrs below ground level connected to 4 mm dia GI earth wire as earth lead upto a length of 7.5 metre long by means of bolts,nuts, washers etc. and protected by GI pipe light grade 15mm dia and 20mm dia GI tubing light grade with funnel for watering, all as shown in electrical plate No 3 of SSR Part-I, back-fill with salt and charcoal, provision of test point including connected to earth test point and necessary earth work excavation in any type of soil PCC (1:3:6) type C1 bed and chamber RCC (1:2:4) type B1, iron grill including GI cover with hinge and funnel watering pipe etc all as specified and directed by Engr-in-Charge.
Dismantling taking out air circuit breaker 400/630/800 amps capacity 3 pole 415 volts 50 Hz and removing mechanical assembly fixed and moving contact set and replacing mechanical parts like spring, bushes, levers and checking for worn out contacts, overvoltage and under voltage settings and replacing the following electrical parts (i) fixed contact assembly (ii) moving contact assembly, (iii) pole assembly (iv) Arc chute . Reassembling, testing and commissioning completely all as directed by Engineer in charge Note:- Replacement of unserviceable electrical parts will be measured and paid for separately under relevant items of this schedule.
Supply only fixed contact assembly for 630/800 Amps 3 pole 415 volts ACB all as specified and as directed by Engineer in charge
All as per item No 51 here-in-before but 400 Amps capacity
Supply only moving contact assembly for 630/800 amps 3 pole 415 volts ACB all as specified and as directed by Engineer in charge.
All as per item No 53 here-in-before but 400 Amps capacity
Supply only pole assembly for 630/800 amps 3 pole 415 volts ACB all as specified and as directed by Engineer -in- charge.
All as per item No 55 here-in-before but 400 Amps capacity
Supply only Arc chute for 630/800 amps 3 pole 415 volts ACB all as specified and as directed by Engineer- in- charge.
All as per item No 57 here-in-before but 400 Amps capacity
Supply and fix aluminium lugs suitable for UG cable of size 6 Sqmm to 25 Sqmm all as specified and as directed.
All as per item No 59 but of size 35 Sqmm to 50 Sqmm
All as per item No 59 but of size 70 Sqmm
All as per item No 59 but of size 95 Sqmm
All as per item No 59 but of size 120 Sqmm
Preparing old faded surface of existing LT panel/feeder pillar located at various places by rubbing and removing the old paint complete and painting with two coats of super enamel paint over a coat of red oxide primer including writing of incoming and outgoing feeder details as required size of letters all as specified and directed.
Cleaning of all the substations located at technical and domestic area once in a month as per Engr-in-charge's instructions by applying cloth for removing dirt on all the installations located inside the sub stations. Cleaning also includes the cleaning of side wall and roof, cleaning of floor, removing the dirt away from the sub station all as specified and as directed. Note:- (i) The quoted rate shall also include the rate of materials like cottton, Broom, MAFF, Stick for mounting Broom, Phenol etc. which are required for proper cleaning of installations
SREE VARU ELECTRICALS
SP ENTERPRISES
RMK PROJECTS
S S BUILDERS
M/S SRI BALAJI ENTERPRISES
RRK PROJECTS
eurekaenterprises
chowdeshwariconstructionco
Thirumala Construction
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .