Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.8 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹8.8 L+₹4,159.50 (0.47%)Rejected-AOC | L2 | Rejected-AOC REJECTED |
Tender Value
₹9 L
EMD Value
₹9,000
Closing Date
6 Nov 2024, 3:00 pmClosed
COMMISSIONER KUMBAKONAM CITY MUNICIPAL CORPORATION
COMMISSIONER KUMBAKONAM CITY MUNICIPAL CORPORATION
Providing New Service Cable MCCBs and KIOSK Box at Senthilnathan Nagar UGD Pumping Station
2024_MAWS_498500_1
9459/2024/E2
Open Tender
Civil Works
Item Rate
180 days
kumbakonam
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹9,000
Yes
2 Jan 2025
4 Nov 2024
6 Nov 2024
4 Nov 2024
6 Nov 2024
4 Nov 2024
Amount
Supply and Delivery of L.T. cables 3.5 1.1 kv grade armoured aluminium conductor cross linked poly ethylene insulated pvc sheathed cables conforming to is 7098 (part i)/1988 and as amended thereafter with ISI marking
Supply and delivery and fixing of Porcelin 500AMS Fuse unit cost including labour,bolt,nut and washer cable electrical connection and testing etc Complete as per IS Specifications
Supply and Delivery of 320AMPS 4 Pole moulded case circuit breaker (mccb) with thermo magnetic relay
Labour charge for 320AMPS 4 Pole moulded case circuit breaker (mccb) with thermo magnetic relay including labour,bolt,nut and washer cable electrical connection and testing etc Complete as per IS Specifications
Supply and Delivery of 200Amps 4 Pole moulded case circuit breaker (mccb) with thermo magnetic relay
Labour charge for 200AMPS 4 Pole moulded case circuit breaker (mccb) with thermo magnetic relay including labour,bolt,nut and washer cable electrical connection and testing etc Complete as per IS Specifications
Supply and Delivery of 125Amps 4 Pole moulded case circuit breaker (mccb) with thermo magnetic relay
Labour charge for 125AMPS 4 Pole moulded case circuit breaker (mccb) with thermo magnetic relay including labour,bolt,nut and washer cable electrical connection and testing etc Complete as per IS Specifications
Provision For 2 Lock one Key arrangements for Genset and EB Side
Supply and Delivery of L.T. cables 3.5 1.1 kv grade 3.5 of 50 armoured aluminium conductor cross linked poly ethylene insulated pvc sheathed cables conforming to is 7098 (part i)/1988 and as amended thereafter with ISI marking(Meter Cutout to ICDP TO MV panel to FCMA to kiosk box)
Supply and Delivery of L.T. cables 3.5 1.1 kv grade 3.5 of 25 armoured aluminium conductor cross linked poly ethylene insulated pvc sheathed cables conforming to is 7098 (part i)/1988 and as amended thereafter with ISI marking(Meter Cutout to ICDP TO MV panel to FCMA to kiosk box)
Supply and delivery and fixing of kiosk box with copper busbar as per I.S Specifications
Supply delivery and fixing of ariel board with 500 amps fuse unit 3nos with suitable board and fixing of RCC Pole As per IS Specification.
For laying in trenches inside the pumproom or in air 95sqmm
Labour Charge for testing FCMA 55HP Starter's and and Motor
Supply delivery and fixing 200 Amps TPN Switch with HRC Fuses Sheet Steel Double Break And Neutral on suitable angle iron framework with MS Cable entry boxes with earth connection only.
Supply and fixing of 65mm (2-1/2") GI pipe (Class 'B') of 6 metre length with 300mm x 300mm x 6mm MS base plate duly welded at the bottom with concreting with construction of masonary pedestal with suitable MS box to house 5A control switch 16A fuse unit (500V) etc with suitable angle iron frame work with door and with lock and key arrangements and with supply and fixing of 48w LED street light fluorescent fitting with copper chokes and condenser with fluorescent tubes with 1 metre of 32mm dia GI pipe (Class 'B') complete with necessary clamps on the above post with PVC unsheathed leads with painting of suitable colour
Supply and Delivery of L.T. cables 3.5 1.1 kv grade 4X6Sq.mm armoured aluminium conductor cross linked poly ethylene insulated pvc sheathed cables conforming to is 7098 (part i)/1988 and as amended thereafter with ISI marking
For laying in trenches including Earthwork upto 95sqmm
Supply and delivery and fixing of rate for mixed di-electric capacitor with tneb test certificate with accessories including banking conformiing to is 2834.
Supply and delivery and fixing of 65mmG.I Pipes (Medium) as per IS 1239/Part 1/2004 TWAD SOR
supply and fixing of 1400mm (56") sweep AC ceiling fan High speed complete with 2 module 100W fan step regulator (Lower end) with 1 metre down rod with fan clamp with side plates and cross arm of size 450mm (18")
Rejuvenation Of Existing M.V Panel cost including painting,internal wiring and earth testing by using meggar as per I.S Specification.
Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than 40mm with copper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry SD 233
Supply and fixing of single box type 4'36W fluorescent fitting complete with electronic ballast with TW round blocks on wall or ceiling with flu tube with PVC unsheathed Copper leads from terminals to the fitting SD 87
Supply and delivery and fixing of Miniature Circuit Breaker 240V/415V 50Hz A.C Supply 1)single pole 6A to 32A 10KvA TWAD SOR-2023-24
Supply and delivery and fixing of Miniature Circuit Breaker 240V/415V 50Hz A.C Supply 1)Four pole 32A 10KvA TWAD SOR-2023-24
Supply and Laying Of 1.5 Sqmm 10 Core Copper PVC Insulated cable as per IS Specifications
Selva Construction (BID ID -1178860)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_592382.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .