Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹56.8 L
EMD Value
₹1.1 L
Closing Date
26 Oct 2026, 3:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
SIG/NORTH
14 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or V whichever is less ;where V= Advertised value of the tender in crores of Rupees N=Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, asper the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information asper format-6, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s)during last 07 (seven) years, ending last day of month previous to the one in which tender is invited:(i)Three similar works each costing not less than the amount equal to30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender.
Defination of Similar Work :- Any signaling work involving outdoor work and / or addition and /or alteration in existing Indoor signaling system. OR any CLS or RI or EI or TPWS or IBS or ABS or BPAC work involving indoor and/or outdoor. Similar work to include indoor if the tendered work involves addition and / or alteration in existing indoor signaling system and outdoor if the tendered work involves outdoor work. OR Any such work involving activities as given in the name of the tendered work.
14 conditions · 5 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The tenderer shall clearly specify whether the tender is submitted on his own or on behalf of a partnership concern. If the tender is submitted on behalf of a partnership concern, he should submit the certified copy of partnership deed (PD) along with the tender and authorization to sign the tender documents on behalf of partnership firm. If these documents are not enclosed along with the tender documents, the tender will be treated as having been submitted by individual signing the tender documents. The tenderer whether sole proprietor, a limited company or a partnership firm if they want to act through agent or individual partners should submit along with the tender or at a later stage, a power of attorney(POA) duly stamped and authenticated by a Notary public or by Magistrate in favour of the specific person whether he or they be partners of the firm or any other person specifically authorizing him or them to submit the tender, sign the agreement ,receive money, witness measurement, sign Measurement Books, compromise, settle, relinquish any claims preferred by the firm and signed No claim certificate and refer all or any dispute to arbitration.
Tenderer should clearly state the status of firm and submit the relevant document in support of authentication, in absence of following/relevant documents the offer of tenderer is summarily rejected: (A)Self-declaration /proprietorship certificate in case of proprietor firm along with POA if any. (B) Partnership deed and power of attorney in case of partnership firm. (C)Certified copy of an extract of resolution passed by the board of directors in case of limited firm or Private Limited Company
(a) Sole Proprietorship Firm: (i)All documents in terms of Para 10 of the Tender Form (Second Sheet)of Tender document
(b) HUF: (i)A copy of notarized affidavit on Stamp Paper declaring that he who is submitting the tender on behalf of HUF is in the position of 'Karta' of Hindu Undivided Family (HUF) and 1.1.2 he has the authority, power and consent given by other members to act on behalf of HUF. (ii)All other documents in terms of Para10 of the Tender Form (Second Sheet)of Tender document
(c) Partnership Firm: (i)All documents as mentioned in para18 of the Tender Form document
(d) Company registered under Companies Act2013: (i)The copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company (ii)A copy of Certificate of Incorporation(iii)A copy of Authorization/Power of Attorney 1.1.4 issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company. (iv)All other documents in terms Para 10 of the Tender Form (Second Sheet) of Tender document
(e) LLP (Limited Liability Partnership): (i)A copy of LLP Agreement (ii)A copy of Certificate of Incorporation (iii)A copy of Power of Attorney/Authorization issued by the LLP in favour of the individual to sign the tender on behalf of the LLP and create liability against the LLP. (iv)An undertaking by all partners of the LLP that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from 1.1.5 participation intenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm/ LLP or JV in which they were/ are partners/members. Concealment /wrong information in regard to above shall make the contract liable for determination under Clause 62 of the Standard General Conditions of Contract.(v)All other documents in terms of Para 10 of the Tender Form(Second Sheet).
(f) Registered Society & Registered Trust: (i)A copy of Certificate of Registration (ii)A copy of Memorandum of Association of Society/Trust Deed (iii)A copy of Power of Attorney in favour of 1.1.6 the individual to sign the tender documents and create liability against the Society/Trust. (iv)A copy of Rules & Regulations of the Society (v)All other documents in terms of Para 10 of the Tender Form (Second Sheet) of tender document
Information as per Para 16 of GCC Part (1)(Tender form second sheet Annex-I) related to Employment/Partnership Etc. of Retired Railway Employees and Clauses 59 (9) & 62 (1) (xv) to GCC regarding employment etc. Of retired government officers by railway contractors
Certificate of Information regarding EMPLOYMENT/PARTNERSHIP etc. of Retired Railway Employees with the tender as per the attached proforma, Format 11 of tender document
Certificate of NO RELATIVE being an employee of Western Railway as per attached Performa Format10 of Tender document
Supply of material, installation Testing and commissioning of Signalling outdoor work in connection with the Extension of High-level passenger platforms at Vaitarna, Saphale, Kelve Road, Boisar, Gholvad,Palghar & Dahanu Road under ADEN/DRD of Mumbai Divison,Western Railway.
SG_216_2_171_WA_PH53~WR
SG_216_2_171_WA_PH53
Open
Works - General
6 Months
Mumbai, Maharashtra
₹0
₹1.1 L
30 Sept 2026
30 Sept 2026
12 Oct 2026
156 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 13,46,167.82 | ||
| — | 10.00 | — | — | ||
| Main Signal Post Tubular 140 mm Dia, 5.6 MtrLength as per IRS: S-6/81 or Latest & RDSODrg. No. SA-24625(Advance).Along with all accessories signal post base and ladder (ALL MS PARTSHOT DIP GALVANIZED -100 MICRON) | — | — | — | 2,12,400 | |
| — | 2.00 | — | — | ||
| Offset brackets for Main Signal, made of tubular steel, outer diameter 140mm, thickness of pipe4.5 mm. horizontal length of pipe 545 mm& vertical length of pipe 324 mm with fixing arrangement on Main Signal post asper Drawing NoSW/554/G/R. (ALL MSPARTS HOTDIP GALVANIZED -100 MICRON) | — | — | — | 8,878.56 | |
| — | 10.00 | — | — | ||
| Excavation and casting of foundation for main signal post as per CSTE 6294 WR with contractor's own material including cement and anchor bolt of standard size. The required scaffolding, ferma, etc. for casting of foundation will have to be brought by the contractor at his own cost | — | — | — | 84,373.4 | |
| — | 10.00 | — | — | ||
| Erection of CLS Post with base and signal unit on top or on OFF set Bracket, fixing of front and back staging, ladder and guards with contractor's own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any The work shall be done as per instructions of Rly engineer at site. It also includes provision & fixing of maintenance platform as per design given by Engineer -In-Charge at site. It also includes supply of padlock for signal units and cable termination box. X' arms to be provided by the contractor till the signals are introduced. The Item includes cutting of Signal post if required by Site In charge. 2/3/4 aspect signal unit mounted directly on signal post. | — | — | — | 83,387.4 | |
| — | 4.00 | — | — | ||
| Phenolic laminated Sheet,grade P3 in standard size of1220 X 1220 x 10 mm as perspec. No IS 2036 of 1995 orlatest. Test report ofmanufacture to be supplied. | — | — | — | 17,771.72 | |
| — | 2.00 | — | — | ||
| Fabrication and fixing of SMC sheet in location box by providing all fixtures as per Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. The work shall be done as per Drg and arrangement similar to SK 783- 1/2. With latest alterations & as per instructions of Rly engineer at site.Note: SMC sheet will be taken in place of phenolic laminated sheet. Single Case | — | — | — | 4,890.72 | |
| — | 2.00 | — | — | ||
| Fabrication and fixing of SMC sheet in location box by providing all fixtures as per Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. The work shall be done as per Drg and arrangement similar to SK 783- 1/2. With latest alterations & as per instructions of Rly engineer at site.Note: SMC sheet will be taken in place of phenolic laminated sheet. Half Case | — | — | — | 1,555.56 | |
| — | 500.00 | — | — | ||
| ARA Terminal blocks with links made of PBT Spec No.s/75/2006 (Rev - 2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4. | — | — | — | 37,500 | |
| — | 500.00 | — | — | ||
| Fixing of ARA Terminals /Screw less connectors and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry. | — | — | — | 11,375 | |
| — | 50.00 | — | — | ||
| Wire long 4 inch ,Ties Size : 3 x 100mm/0.1" x 3.9" (WL), Tags Size: 20mm x 13mm (each packet contains 100 pieces of tags)(Nos of packets consider as nos) | — | — | — | 3,835 | |
| — | 500.00 | — | — | ||
| Termination of outdoor cables, main cables laid in location boxes, Cable termination rack etc. at both ends on ARA terminal or on 8 way terminals or on screw less connectors. Both ends of a cable core terminated shall be counted as one terminal. This includes all associated works of pulling out the cable from underground, peeling off insulation, dressing of cable core supported on sting rod with contractor's own material. The work shall be done as per instructions of Rly engineer at site. | — | — | — | 11,850 | |
| — | 25.00 | — | — | ||
| Pad locks Godrej make, Hardened NavTal 7 lever, 65mm Dia with common key or similar product having same feature & technical data. | — | — | — | 4,919.75 | |
| — | 5.00 | — | — | ||
| Maintenance Free Earth Electrode of length3m, including supply of 3 bags of Earthenhancementmaterial for earthling(10KGs/bag) for each electrode & otheraccessories as per Drg. No. SDO / RDSO/E&B/001 andRDSO Spec No. RDSO /SPN/197/2008. This item includes thefollowing items: (a) Copper bonded steelearth electrodeof 3.0 meter long & 17.2 mmdia with Cu- bonding thickness of min 250micron - 1 no. (b) Earth-enhancingcompound(10 Kg/Bag) - 3 No. (c) Cu- strip 200 X 25 X 6 mm to terminate earth rod =1no. (d) Cu-strip 300 X 25 X 6 mm(MEEB)= 1 no. (e) Cu-strip 150 X 25 X 6mm (SEEB) = 1 no. | — | — | — | 52,015 | |
| — | 5.00 | — | — | ||
| Installation of Maintenance Free Earth Electrode for Maintenance Free Earth spec of RDSO/SPN/197/2008. | — | — | — | 7,283.95 | |
| — | 5.00 | — | — | ||
| Supply of Fiber/ SMC/FRP/RCCEarthChamber as per STS/E/TAN/3006 3.0 ver or as per instructions of Engineer Incharge | — | — | — | 3,245 | |
| — | 4.00 | — | — | ||
| Preparation and fixing of location box board on 03 mm ACP sheet with size 12 x 18 size A3 for location box including pasting of printed/ painted vinyl sheet and lamination (printing/painting of location detail on vinyl sheet covered in schedule item separately). | — | — | — | 958.92 | |
| — | 75.00 | — | — | ||
| Transferring of Signaling/Telecom cables from existing Location box to New Location box . The work include breaking/ Dismantling of Existing foundation of locations, excavating and removing / segregating coils of 2C/6C/12C/19C/24C/30C/Quad cables which may be about 10 mtrs. in length. These cables are to be disconnected and removed from the existing location one by one as per the instruction and under the supervision of Railway staff present at site. The cable is then to be inserted and terminated in new location box. The item includes neatly dressing of cable, making wiring tree etc.The material required to dressing /lacing will be arrange by contactor. The work is required to be done systematically and with due precaution during the block or disconnection within the time that may be allowed. The excavation work to be done carefully without damaging the cable to avoid undue failure. (Termination charges will be given separately). Note: Proportionate payment will be made if cable of other length. One No unit = One cable of 10 m length) | — | — | — | 23,850 | |
| — | 5.00 | — | — | ||
| Providing brick masonry in ratio 1:6 cement and mortar including plastering with 1:4 cement and sand mixture both sides, 20 mm thick each with contractor's owned class II bricks, including excavation, curing, grouting, bolting etc. wherever required. Bricks sand and cement to be supplied by the contractor. | — | — | — | 10,306.8 | |
| — | 5.00 | — | — | ||
| Cement concrete work for miscellaneous items in the ratio 1: 3: 6. Item includes excavation, ramming, curing and plastering with cement & sand mixture (aggregate not exceeding 3.8 cm.) (Aggregate cement & sand to be supplied by the contractor). | — | — | — | 31,295 | |
| — | 10.00 | — | — | ||
| Dismantling / Releasing of existing Signaling Gears. One Signalling gear will be all parts of one signal (consisting of CLS unit, Signal post along with base) or lever frame (5 levers set), or one point (consisting of all parts of a mechanical point, point machine, ground connections etc.) or one track circuits (consisting of battery box & other parts of DC Track circuit / AFTC /DAC) or one Block instruments or One Lifting Barrier or One Location Box etc. .This includes the cost of transportation of release materials to store depot or as decided by consignee in charge. This work to be done by contactors with his own vehicle and labour. (Per unit means Per Gear). | — | — | — | 10,628.2 | |
| — | 10.00 | — | — | ||
| Dismantling of Concrete foundation/ DemolishingRCC/CC/Stone work /CuttingTar/ carpentering/ CC Flooring/Precast concrete slab/ Brick work including leading the debrisinside Railway limit or outsideRailway limit as directed by site in charge. This work to be done by contactors with his own vehicle and labour. | — | — | — | 6,054.1 | |
| — | 450.00 | — | — | ||
| Half Round RCC pipes & collars of 150 mm internal dia (1 meter long) along with collars as per IS No. 458/2003 of NP type. Tenderer shall submit inspection/test report before supply for priorapproval by Engineer in charge. | — | — | — | 71,919 | |
| — | 200.00 | — | — | ||
| Excavation of cable trench as per cable route plan, 1 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr wide advised by Engineer-in-charge alongside the track in normal (all type) soil/strata, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc., covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on Western Railway and instructions of Railway Engineer at site. In case 1m depth of trench is not achievable due to site conditions, specific approval of JA grade officer will be required for each site where trench depth of 1m is not possible. Without the approval of JA Grade officer, no payment for trenching will be made for trench depth less than 1m. | — | — | — | 1,67,800 | |
| — | 30.00 | — | — | ||
| Digging of trench 1.2 M deep from rail flange/ road level and, 0.3 Mtr to 0.6 Mtr wide and back filling after placing of DWC/ RCC/GI pipe. (Placing of DWC/RCC/GI pipe covered separately).The ballast disturbed be screened and dressed as required by Engineer-in-charge or his representatives and road tarred immediately. For track crossing, Drg. No.CSTE/3644 Pg.7 of 11 and for Road Crossing, Drg. No. CSTE/3644 Pg. 5 of 11 are to be followed. | — | — | — | 26,217.9 | |
| — | 450.00 | — | — | ||
| Placing of DWC/RCC pipes along with collars in trenches at places of track and road crossings, platform cuttings etc. also for straight cable laying. (Cable laying is covered separately.) | — | — | — | 14,949 | |
| — | 5000.00 | — | — | ||
| Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes/ Trucking. This also includes laying of cables in track crossings & road crossings. Item includes provision of labels of colored plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each G.P.(Cables will be daggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes. | — | — | — | 46,850 | |
| — | 10.00 | — | — | ||
| Supply and installation of RCC cable route marker engraved and painted on both side along the route every 50mm and route diversion as per Drg. No 4014/00/CC4 or latest/ Stone marker. | — | — | — | 4,126.6 | |
| — | 4.00 | — | — | ||
| Installation of track device (double rail contact) including digging of trench, track crossing, laying of anti-rodent, anti-oxidant & non-flame propagating type Double Walled Corrugated (DWC) pipe as per IS- 14930 part- I or II or latest and all other accessories as per site requirement to be for laying of transmitter and receiver cable. The item also includes installation of EJB / Track side Electronics including foundation & earthing as per OEM's guidelines and Technical requirement & specification with their own material. NOTE: Installation / programming / configuration / commissioning of Axle counter equipment to be carried out in accordance with latest guidelines issued by Railways/RDSO preferably by Authorized representative of OEM. | — | — | — | 51,807.36 | |
| — | 4.00 | — | — | ||
| Fixing and wiring of DC track circuit equipments i.e. track feed charger, resistance, track relay, battery, PPTC fuses etc., in the Apparatus Case and battery box as per standard practice. Termination of tail cable on M 6 / Screw less terminals WAGO or FINOLEX or similar approved make terminals/ fuse blocks / HRC fuse. Item includes testing / commissioning of track circuit. Complete wiring material (including PPTC fuses) which are not covered in Schedule will be supplied by contractor. (Supply of Track feed battery charger, track feed battery, resistances & 'B' type choke & Track relays will be supplied by Railways / covered in Schedule separately). | — | — | — | 26,668 | |
| — | 4.00 | — | — | ||
| Installation of DC track circuits covering points zones also. The item includes provision of continuity bonds of seven strand PVC jacketed wire/ GI wire 8 SWG on rail joints after drilling bond-hole of 7.0/7.1/7.2mm Dia (double bond with sleeves and rail clips are to be provided at each rail joint), insertion of insulated block joint, fixing of Track lead Junction box on MS angle two numbers of size 40X40X5 mm 1200 mm length for track feed/ jumper / track relay ends of track CCTs (as per double TLJB arrangements) and also for fixing jumper cables as per insulation diagram WR Drg No. CSTE/6055 and standard practice, making rail connections through suitable insulated sleeves from Track lead Junction box at TF, jumper & TR end with seven strand PVC jacketed wire /GI wire 8 SWG, rail clips for fixing bond wire on the TLJB as per standard practice, termination of tail cables on bootleg terminals etc. TF/TR wiring shall be fixed on the suitable arrangement on PRC sleepers with the help of hooks. Hooks shall be provided on PRC sleepers with the help of suitable steel bracket. This item also includes fixing & supply of channel pins etc. The item also includes supply of MS angles/ trestles, GI wire 8 SWG / seven strand PVC jacketed wire, hooks, rail clips etc. | — | — | — | 29,314.88 | |
| — | 10.00 | — | — | ||
| Manufacturing, fabrication and supplying retroreflective sign boards made up of thermoset plastic toughened moulding composite sheets of 3.0mm thickness Face to be fully covered with High Intensity Grade (encapsulate Lence type) sheeting of 3M, in various colour combination including subject matter, numbers, message, symbols, borders, etc.as approved by Engineer In charge, pasted on substrate by suitable adhesive material & with screws/rivets at 20 cm centre to centre to back support sheet.(Warranty Period: Upto 30 months from the date of delivery.) | — | — | — | 87,969 | |
| — | 50.00 | — | — | ||
| Supply of vertical post made up of thermoset plastic toughened moulding Composite material of section 75 mm x 45 mm x 3.0 mm (outside dimension) in black colour, rapped with white colour retroreflective tape of 300 mm in alternate bands, with suitable anchoring arrangement of cross round bars of dia 12mm and 200mm length at 50mm to 75mm above from bottom for Sr. DEN/SE/CSTM as per attached drawing and specification. | — | — | — | 35,931 | |
| — | 1.00 | — | — | ||
| Torque wrench with reversible ratchet,10-50 Nm withprecision +/- 3%Make:- WERA,Gedore, Stahwille,Snapon. | — | — | — | 21,791 | |
| — | 25.00 | — | — | ||
| Maintenance of Track mounted equipments like S&T fitting on turnouts including differentactivitiesduring BCM/TTM/TRRworks as follows:- Speciallyopening and refixing of DC- TCjumpers/AFTC jumpers / Axlecounter,transducers duringdifferent Engg. works Opening ofDC-TC /AFTC jumpers /axle countertransducers digging work fromrailto TLJB /TMU /0 bond /location isrequired to be done as per siterequirement also after refixing ofDC-TC /AFTCjumpers /Axle countertransducers needs to be buried inproper depth. It includes drillinghole in rail as per siterequirement.The team to be provided for thiswork should comprise of : Fitter- 1Nos., Blacksmith 1Nos.Mason/Carpenter- 1 No. andHelpers-5 Nos. also it include anywork of EOLB or sliding boom andearthing arrangementof Signallinggears. Any other work as perinstruction of Railway Engineer. AllT&P & Jigs required to execute theworkwill be supplied by thecontractor. | — | — | — | 1,32,450 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .