Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.3 LAccepted-AOC | L1 | Accepted-AOC REASONABLE | |
| 2 | L2₹38.3 L+₹31,918.28 (0.84%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L2 | Rejected-Finance HIGH RATE | |
| 3 | L3₹39.1 L+₹1.1 L (3.03%)Rejected-Finance 171 NARAYAN PETH PUNE PUNE MAHARASHTRA 411030 | PUNE | MAHARASHTRA | 411030 | L3 | Rejected-Finance HIGH RATE | |
| 4 | L4₹44.4 L+₹6.4 L (16.9%)Rejected-Finance | L4 | Rejected-Finance HIGH RATE | |
| 5 | L5₹45.3 L+₹7.3 L (19.3%)Rejected-Finance | L5 | Rejected-Finance HIGH RATE |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
4 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI PRAVEEN KUMAR, IDSE
GE KHADAKWASLA NDA KHADAKWASLA PUNE-411023
REPAIR AND REPLACEMENT OF ELECTRICAL OVERHEAD LINES AND LT UG CABLES AND CONNECTED WORKS AT NDA KHADAKWASLA
2023_MES_601541_1
8707/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE KHADAKWASLA
As per Tender Documents
9 documents required · 9 mandatory
₹500
Yes
GE KHADAKWASLA
₹96,000
Yes
21 Jul 2023
6 Jun 2023
6 Jul 2023
6 Jun 2023
4 Jul 2023
22 Jun 2023
6 Jun 2023 - 21 Jun 2023
Amount
Relaying / Rerouting of serviceable XLPE LT UG cable of following sizes including disconnection from LT Panel/Pole/FP etc and reconnection after re-laying work to LT Panel/Feeder Pillar /MDB according to existing system with suitable size of AL Lugs, nut-bolts & washers etc and fixed on any type of wall with suitable size of GI saddles etc complete of following sizes :- Note - Excavation / earthwork, cable protection covers & sand cushioning will be measured and paid separately under respective items of BOQ. (a) 3.5 Core 400 Sqmm
(b) All as per item No 1 above but 3.5 Core 300 Sqmm
(c ) All as per item No 1 above but 3.5 Core 240 Sqmm
(d) All as per item No 1 above but 3.5 Core 185 Sqmm
(e ) All as per item No 1 above but 3.5 Core 150 Sqmm
(f) ll as per item No 1 above but 3.5 Core 120 Sqmm
(g) All as per item No 1 above but 3.5 Core 95 Sqmm
(h) All as per item No 1 above but 3.5 Core 70 Sqmm
(j) All as per item No 1 above but 3.5 Core 50 Sqmm
(k) All as per item No 1 above but 3.5 Core 35 Sqmm
(m) All as per item No 1 above but 3.5 Core 25 Sqmm
(n) All as per item No 1 above but 4 Core 16 Sqmm
(m) All as per item No 1 above but 4 Core 10 Sqmm
Supply and laying in replacement including testing and commissionnig of LT UG Cables 1100 volts grade, XLPE insulated, screened and PVC sheathed, galvanised steel strip armoured with multi stranded aluminum conductor, ISI marked, heavy duty including disconnection from LT Panel/Fedder Pillar/Pole etc and reconnection after laying work to same LT Panel/Feeder Pillar /Pole according to existing system with suitable size of AL Lugs, nut-bolts & washers etc including cables laid in trenches/ducts/under plinth floors/ passing through pipes etc or fixed on any type of wall with suitable size of GI saddles etc complete of following sizes :- Note - Excavation / earthwork, cable protection covers & sand cushioning will be measured and paid separately under respective item of BOQ. (a) 3.5 Core 400 Sqmm
(b) All as per item No 14 above but 3.5 Core 300 Sqmm
(c ) All as per item No 14 above but 3.5 Core 240 Sqmm
(d) All as per item No 14 above but3.5 Core 185 Sqmm
(e ) All as per item No 14 above but 3.5 Core 150 Sqmm
(f) All as per item No 14 above but 3.5 Core 120 Sqmm
(g) All as per item No 14 above but 3.5 Core 95 Sqmm
(h) All as per item No 14 above but 3.5 Core 70 Sqmm
(j) All as per item No 14 above but 3.5 Core 50 Sqmm
(k) All as per item No 14 above but 3.5 Core 35 Sqmm
(l) All as per item No 14 above but 3.5 Core 25 Sqmm
(m) All as per item No 14 above but 4 Core 16 Sqmm
(n) All as per item No 14 above but 4 Core 10 Sqmm
Excavation in trenches, n.exc 1.5m wide and n. exc 1.5 m depth and getting out for foundation of pole, stay, laying of cable and pipe etc :- (a) Hard/Dense soil
(b) All as per item No 27 above but Soft / Disintegrated Rock
Returning and filling, including spreading levelling and well ramming in layers n exc 25 cm all as specified and directed.
Removing excavated material a distance n. exc 50 m & depositing where directed at a level n. exc 1.5 m above the starting point.
M&L for dry sand cushioing to under ground cable in trenches incl spreading, leveling and hand punning complete all as specified and directed. Note : For measurement purpose punned thickness shall be considered.
Supply and laying in replacement of burnt clay fly ash building bricks, designation 75 (Kg/Sqcm), laid in right angle along the cable for protection of cable, complete all as specified and directed.
Supply & Laying in replacement of half round un-reinforced concrete pipe, inner dia 150 mm and outer dia 200mm, half round for bottom and half round for top and before laying excavated area shall be leveled, complete all as specified and directed. Note : 01 Half round top and 01 half round bottom together will be considered as one running meter
Supply and laying 40 x 32 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 10 to 16 Sqmm 4 core complete all as specified and directed
Supply and laying 50 x 38 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 25 to 35 sqmm 3.5 core complete all as specified and directed
Supply and laying 63 x 50 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 50 Sqmm 3.5 core complete all as specified and directed
Supply and laying 77 x 63 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 70 Sqmm 3.5 core complete all as specified and directed
Supply and laying 90 x 75 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 95 Sqmm 3.5 core complete all as specified and directed
Supply and laying 110 x 95 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 120 to 150 Sqmm 3.5 core complete all as specified and directed
Supply and laying 120 x 103 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 185 to 240 Sqmm 3.5 core complete all as specified and directed . .
Supply and laying 160 x 135 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approved colour complete with fittings i.e.coupler,Tee, elbow clamp for cable protection of size 300 to 400 Sqmm 3.5 core complete all as specified and directed
Supply and laying in replacement G.I pipe light grade pipe 100 mm dia with all fittings required for protection of under ground cable complete all as specified and as directed.
M&L for road cutting through existing bituminous road as required for laying pipe/cable etc and make good with and including earthwork and necessary excavation, complete material required to match with the existing one or with PCC (1:2:4) type B1 and bitumin complete all as specified and as directed
M & L for Straight Through Jointing Kit Heat Shrink type suitable for 1.1 KV LT XLPE armoured aluminium stranded conductor Cable Outdoor type complete with jointing material and accessories including taking shut down and opening the cable from both side of Bus Bar Panel/LT Panel/MCCB/ACB etc and re-terminated the same cable in the same Bus Bar Panel/LT Panel/MCCB/ACB etc according to existing system after completion of jointing work complete all as specified and directed of following sizes :- (a) 3.5 Core 400 Sqmm
(b) All as per item No 44 above but 3.5 Core 300 Sqmm
(b) All as per item No 44 above but 3.5 Core 240 Sqmm
(c ) All as per item No 44 above but 3.5 Core 185 Sqmm
(d) All as per item No 44 above but 3.5 Core 150 Sqmm
(e ) All as per item No 44 above but 3.5 Core 120 Sqmm
(f) All as per item No 44 above but 3.5 Core 95 Sqmm
(g) All as per item No 44 above but 3.5 Core 70 Sqmm
(h) All as per item No 44 above but 3.5 Core 50 Sqmm
(j) All as per item No 44 above but 3.5 Core 35 Sqmm
(k) All as per item No 44 above but 3.5 Core 25 Sqmm
(l) All as per item No 44 above but 4 Core 16 Sqmm
(m) All as per item No 44 above but 4 Core 10 Sqmm
M & L in replacement of earthing complete with galvanized steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 m deep below normal ground level in any type of soil strata, connected to galvanized earth lead wire of 4 mm dia by means of bolts, nuts and washers of galvanised iron or steel all as shown in earth plate No 3 of MES schedule 2009 Part – I connected to LT Poles /DBs etc. as required including necessary excavation and earth work, concrete pit chamber, cover of PCC 1:2:4 type B1 including lifting handle and Earth lead and 20mm Dia GI watering pipe medium grade, Funnel, wiremesh, etc. complete all as specified and directed by Engr-in-Charge including testing on completion.
S & F in replacement of MCCB's 415 Volts , 4 pole with Fix / adjustable type 63 Amps with breaking capacity 16 KA complete all as specified and as directed.
Labour for restretching/tightening the existing LT overhead conductors & GI earth wire mounted on insulators of any type on poles manually or by mechanical means to the extent of permissible sag and tension and binding with steel wires of appropriate size complete having 5 to 7 conductors per span of approx 35-40 mtr length between poles and tightning of stay wire etc complete all as specified and directed
Supplying and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium 6 Sqmm stranded conductor, Twin core cable flat served with inner sheathing of PVC tape and overall PVC sheathed in service connections including taking down existing one complete all as specified and directed.
S & F in replacement of LT Jumper with the help of Aluminium Counductor Steel Reinforcement. The length of jumper shall not be less than 2 meter including connection with the help of connector and aluminium lugs, nut bolt washers etc on the LT Pole complete all as specified and directed
Pruning / trimming of branches of trees interfering or overhanging on electrical overhead lines in such a way to have a clearance of not be less than 2 mtrs all around the outermost conductor of the span complete all as specified and directed Note : span shall be measured pole to pole as One Span).
M&L in replacement aluminium conductor steel reinforced fixing on the over head LT pole with the help of aluminium tapes/ binding wire including taking down existing one complete all as specified as directed
S & F in replacement pin type porcelain vitreous white brown or green insulator of size 100 mm height, 65 mm dia suitable for 1100 volts grade including one galvanised mild steel spindle two galvanised iron washers and one galvanised iron nut including taking down existing one, complete all specified and directed.
S & F in replacement Shackle type porcelain vitreous white brown or green insulator of size 100 mm height, 115 mm dia suitable for 1100 volts grade including two galvanised mild steel straps, washers, insulators bolts and nut etc including taking down existing one complete all specified and directed.
M&L in replacement stay assembly complete with accessories as shown in electrical plate no 1 including loop type insulator, stay clamps, stay strands, excavation work of any type of soil strata and PCC work and taking down existing one complete all as specified and directed
Labour for tightening/re-stretching of stay assembly complete with accessories such as Stay stranded wire, Stay Clamps, Bow including replace the damaged oval/loop type insulator with new one etc complete all as specified and directed
M&L for plain concrete cement (1:3:6) type C2 (Using 40mm size graded stone aggregate) for foundation, filling and mass concrete of poles including necessary form work complete all as specified and directed.
Supply & Fix including commissioning digital automatic timer switch distribution panel board, factory assembled in powder coated steel sheet enclosure, comprising of 4P MCB, 40 Amps & 3 Pole power contactor 40/50 Amps and 230V digital time switch for controlling LED street lights, including earth work for fixing Timer switch distribution panel board and shall be provided 4 Nos 20x20x3mm thick angle iron supports of not less than each 0.6 mtr height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 type C1 at suitable depth complete all as specified and directed at site.
M&L for PCC (1:3:6) type C1 (Using 20mm size graded stone aggregate) for coping of poles including fair finishing the exposed surfaces even and smooth without using extra cement including necessary formwork complete all as specified and directed
Demolition of unreinforced PCC, floors, foundation etc in any position and any description including removal of demolished material complete all as specified and directed.
Supply & Fix on pole/ wall, SMC Junction box dimensions (270 x 225 x 135)mm (LxBxD), 3 phase 4 wire system, including cable connecting base, 6 Amp DP MCB with mounting SS railing, Cable lugs suitable to 35 Sqmm 3.5 core cable, connection for incoming and outgoing cables including Fixing arrangement on wall/ pole etc complete all as specified and directed
M&L for cross arms bracing supports clamps and back plate fabricated from structural steel sections including nuts bolts washers welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat and one coat of synthetic enamel paint including dismantling cross-arms of MS channel or angle section etc. complete all as specified and directed
M&L in replacement steel tubular swaged poles complete with cast iron base plate finial taper plug bolts nuts & screws as specified type 410 SP-31 (9 mtrs long) as Pole/Strut including dismantling old/US steel struts, complete all as specified and directed.
M&L for preparation of existing surface of steel tubular pole by srapping down peeled off old paint, cleaning etc of length 8.5/9/11 mtrs and cross arms etc and applying one coat of aluminium coat paint including rewriting pole Nos as directed with black paint complete all as specified and directed
S&F in replacement of 4 core 10 Sqmm PVC insulated multistranded copper cable including suitable size of Copper lugs, nut-bolts and washers etc and also clamped on any type of wall with suitable size of GI clamps/shaddles including flexible conduit etc complete all as specified and directed.
S & F in replacement 3 core 1.5 Sqmm PVC insulated multistranded copper cable including suitable size of Copper lugs, nut-bolts and washers etc and also clamped on any type of wall with suitable size of GI clamps/shaddles etc complete all as specified and directed.
M&L for LT UG Cable fault finding/testing from FP Box to fault location including taking shut down and opening the cable from both side of Bus Bar Panel/LT Panel/MCCB/ACB/Transformer etc and re-terminated the same cable in the same Bus Bar Panel/LT Panel/MCCB/ACB etc according to existing system after completion of fault finding/testing work complete all as specified and directed of following sizes cables :- Note:- Job will be measured after fault detection of any type regarding this decision of Engineer-in-charge shall be final & binding. (a) 3.5 Core 400 Sqmm
(b) All as per item No 78 above but 3.5 Core 300 Sqmm
(c ) All as per item No 78 above but 3.5 Core 240 Sqmm
(d) All as per item No 78 above but 3.5 Core 185 Sqmm
(e ) All as per item No 78 above but 3.5 Core 150 Sqmm
(f) All as per item No 78 above but 3.5 Core 120 Sqmm
(g) All as per item No 78 above but 3.5 Core 95 Sqmm
(h) All as per item No 78 above but 3.5 Core 70 Sqmm
(j) All as per item No 78 above but 3.5 Core 50 Sqmm
(k) All as per item No 78 above but 3.5 Core 35 Sqmm
(l) All as per item No 78 above but 3.5 Core 25 Sqmm
(m) All as per item No 78 above but 4 Core 16 Sqmm
(n) All as per item No 78 above but 4 Core 10 Sqmm
Labour for disconnecting the LT UG Cable (approx 10-12 No of Cables) of any size from LT ACB breaker and setting aside at safe place/side by taking proper shut down for human saftey, cleaning the duct/trench by removing foreign material/mud from trench/duct including reconnecting the all LT UG Cables according to existing system complete all as specified and directed.
M & L in replacement for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones of Post Office RED Colour and fixed on LT Poles with M.S. clamps, bolts and nuts of required size, for 440 Volts LT of size 200 X 150mm complete including taking down existing one complete all as specified and directed.
M & L for route tracing of LT UG cables under ground/road from one end to another end of cable, size upto 400 sqmm including taking shut down and opening the cable from both side of Bus Bar Panel/LT Panel/MCCB/ACB/Transformer etc and re-terminated the same cable in the same Bus Bar Panel/LT Panel/MCCB/ACB etc according to existing system after completion of route tracing work all as specified and directed.
S & F Wire mesh Cable Tray Hot Dipped Galvanized size 54 X 100mm, Trays should comply Standard EN ISO 14 61: at least 550 h of SST. The deflection of cable tray must be no more than 1/200th of the distance between two supports and tested in accordance with the standard IEC 61537, Wire cable trays must be designed with an optimum span of 1.5 m, taking into account the maximum carrying capacity authorised by the manufacturer including all standard wall mounting accessories e.g. SS Mounting Bracket, bends, Fastners, kitastar, nut, bolts and washers etc, It shall be manufactured with a longitudinal 'T- welded' safety edge complete all as specified and directed.
M & L in replacement of GI Earthing complete with galvanized steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 m deep below normal ground level in any type of soil strata, connected to galvanized iron strip 25 x 4 mm by means of bolts, nuts and washers of galvanised iron or steel all as shown in earth plate No 3 of MES schedule 2009 Part – I connected to machinery/equipment for LT Panel, Feeder Pillars, Sub Feeder Pillars etc. as required including necessary excavation and earth work, concrete pit, chamber and pit cover in PCC 1:2:4 type B1 including lifting handle and Earth lead and 20mm Dia GI watering pipe medium grade, Funnel, wiremesh etc. complete all as specified and directed by Engr-in-Charge including testing on completion.
S & F in replacement of Wire mesh Cable Tray Hot Dipped Galvanized size 54 X 300mm, Trays should comply Standard EN ISO 14 61: at least 550 h of SST. The deflection of cable tray must be no more than 1/200th of the distance between two supports and tested in accordance with the atandard IEC 61537, Wire cable trays must be designed with an optimum span of 1.5 m, taking into account the maximum carrying capacity authorised by the manufacturer including all standard wall mounting accessories e.g. SS Mounting Bracket, bends, Fastners, kitastar, nut, bolts and washers etc , It shall be manufactured with a longitudinal 'T- welded' safety edge complete all as specified and as directed.
S & F in replacement PVC spiral spacer for LT overhead line of gray colour suitable for 3 phase 4 wire system, length of the spacer should not be less than 1200mm including taking down existing one and all arrangements shall be adopted by contractor for the same complete all as specified and directed. Note : Necessary ladder & scafolding etc if required for this job is the responsibility of the contractor and rates included in this job.
S & F 400 Sqmm single core multistranded Copper Cable, 1100 Volts XLPE insulated for connection of Transformer LT side to LT panel MCCBs with copper lugs, SS nut bolts and washers accessories as per site requirement complete all as specified and directed
S & F in replacement of GI strip 25 x 4 mm earth as earth continuity conductor or main earthing lead fixed to wall batten or recess or chases or buried in ground or fixed to poles or any other indicated situation etc., cjomplete all as specified and directed.
S & F in replacement of Cable Route Marker made up of Cast Iron of dia 80 mm and thickness 4.65 mm with supporting angle iron of size 20 x 20 x 3 mm and height 0.6 mtr for stand including priming, painting and wirting of "LT UG CABLE" in suitable size of letter including necessary earthwork and grouted at suitable depth in PCC 1:3:6 Type C2 using 40 mm graded aggregate in mass concrete complete all as specified and directed
metro electrical services
KESARI AND SONS
SONU ENTERPRISES
Star Electrical
CHAITANYA WINDWELL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .