| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.3 LAccepted-AOC | L1 | Accepted-AOC DUE TO L1 | |
| 2 | L2₹22.5 L+₹2.7 L (13.9%)Rejected-AOC | L2 | Rejected-AOC HIGHER RATE | |
| 3 | L3₹22.6 L+₹2.8 L (14.3%)Rejected-AOC BARIYAWAN BARIYAWAN BARIYAWAN BARIYAWAN AMBEDKAR NAGAR UTTAR PRADESH 224210 | AMBEDKAR NAGAR | UTTAR PRADESH | 224210 | L3 | Rejected-AOC HIGHER RATE | |
| 4 | L4₹23.3 L+₹3.5 L (17.6%)Rejected-AOC RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L4 | Rejected-AOC HIGHER RATE | |
| 5 | L5₹23.9 L+₹4.1 L (20.8%)Rejected-AOC 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L5 | Rejected-AOC HIGHER RATE |
Tender Value
Refer Docs
EMD Value
₹57,320
Closing Date
14 Aug 2023, 6:00 pmClosed
GE NEW DELHI
GE NEW DELHI, SP MARG NAR ABHM GATE NO 5
REPAIR/REPLACEMENT OF E/M NATURE OF WORKS OLD/ UNSERVICEABLE WIRING AND CONNECTED WORKS AT NAU SENA BAGH-I CHANAKYAPURI AND NAU SENA BAGH-II NARAINA UNDER GE NEW DELHI
2023_MES_609330_1
NIT No GE/ND-45/2023-24
Open Tender
Civil Works
Item Rate
270 days
GE NEW DELHI
REFER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE NEW DELHI
₹57,320
Yes
15 Jan 2024
17 Jul 2023
16 Aug 2023
17 Jul 2023
14 Aug 2023
31 Jul 2023
Amount
S&F in replacement of switch piano flush type 6 Amp, SP, one way 230 volts AC all as specified. Note:-The make should match the existing switch/socket on ground.
S&F in replacement of switch piano flush type 6 Amp SP two way 230 volts AC all as specified. Note:-The make should match the existing switch/socket on ground.
S&F in replacement of bell push switch piano flush type 6 Amps, SP, 230 Volts AC all as specified. Note:-The make should match the existing switch/socket on ground.
S&F in replacement of switch piano flush type 16 Amp, SP, one way 230 volts AC all as specified. Note:-The make should match the existing switch/socket on ground.
S&F in replacement of piano flush type socket out let 5 pin 5 Amp, 230 volts AC all as specified. Note:-The make should match the existing switch/socket on ground.
S&F in replacement of piano flush type multipurpose socket out let 6 pin 15/5 Amp, 230 volts AC all as specified. Note:-The make should match the existing switch/socket on ground.
S&F in replacement of piano type electronic fan regulator suitable for 1200/1400 mm ceiling fan all as specified .Note:-The make should match the existing fan regulator on ground.
S&F in replacement of Plug Top 05 Amps, 230volts AC, 3-pin complete all as specified and as directed.
S&F in replacement of Plug Top 16 Amps, 230volts AC, 3-pin complete all as specified and as directed.
S&F in replacement of call bell suitable for 230 volts AC all as specified. Note:-The make should match the existing bell on ground.
S&F in replacement of ceiling rose 3 terminal / PVC / Polycarbonate, insulated body all as specified.
S&F in replacement of B-22 holder suitable for Led bulb 9 watts all as specified. Make: As per sample.
S&F in replacement of fan capacitor 1.5 Mfd all as specified.
S&F in replacement of fan capacitor 2.5 Mfd all as specified.
S&F in replacement of fan capacitor 3.15 Mfd all as specified.
S&F in replacement of fan capacitor 4.0 Mfd all as specified.
S&F in replacement of modular switch 06 A SP one way 240 volts complete all as specified and as directed. Note:-The make should match the existing switch/socket on ground.
S&F in replacement of modular switch 16 A SP one way 240 volts complete all as specified and as directed. Note:-The make should match the existing switch/socket on ground.
S&F in replacement of modular socket 6 A Multi socket for 2 pin and 3 pin 240 volts complete all as specified and as directed. Note:-The make should match the existing switch/socket on ground.
S&F in replacement of modular socket outlet 16 A-2/3 pin combined 240 volts complete all as specified and as directed. Note:-The make should match the existing switch/socket on ground.
S&F in replacement of modular Fan regulator 240 volts complete all as specified and as directed. Note:-The make should match the existing switch/socket on ground.
S&F in replacement of modular white cover plate with frame 2 module.
S&F in replacement of modular white cover plate with frame 3 module.
S&F in replacement of modular white cover plate with frame 4 module.
S&F in replacement of modular white cover plate with frame 6 module.
S&F in replacement of modular white cover plate with frame 8 module.
S&F in replacement of modular white cover plate with frame 12 module.
S&F in replacement of modular metal flush box, 2 module.
S&F in replacement of modular metal flush box, 3 module.
S&F in replacement of modular metal flush box, 4 module.
S&F in replacement of modular metal flush box, 6 module.
S&F in replacement of modular metal flush box, 8 module.
S&F in replacement of modular metal flush box, 12 module.
S&F in replacement of decorative lamninated hylam sheet 3 mm thick of size 8"x5" including necessary cutting of sheet for fixing switch/socket.
S&F in replacement of decorative lamninated hylam sheet 3 mm thick of size 9"x11" including necessary cutting of sheet for fixing switch/socket.
S&F in replacement of decorative lamninated hylam sheet 3 mm thick of size 9"x13" including necessary cutting of sheet for fixing switch/socket.
S&F in replacement of decorative lamninated hylam sheet 3 mm thick of size 5"x5" including necessary cutting of sheet for fixing switch/socket.
S&F in replacement of T-cover/rount sheet of any size as required at site complete as specified and directed
S&F in replacement of single core,FRLSH cable, PVC insulated, unsheathed, multi stranded copper conductor cable of size 1.5 Sqmm all as specified.
S&F in replacement of single core,FRLSH cable, PVC insulated, unsheathed, multi stranded copper conductor cable of size 2.5 Sqmm all as specified.
S&F in replacement of single core, FRLSH cable, PVC insulated, unsheathed, multi stranded copper conductor cable of size 4 Sqmm complete all as specified and as directed.
S&F in replacement of single core, FRLSH cable, PVC insulated, unsheathed, multi stranded copper conductor cable of size 6 Sqmm complete all as specified and as directed.
S&F in replacement of single core, FRLSH cable, PVC insulated, unsheathed, multi stranded copper conductor cable of size 10 Sqmm complete all as specified and as directed.
S&F in replacement of two core cable, PVC insulated, unsheathed, multi stranded copper conductor cable of size 1 Sqmm complete all as specified and as directed.
S&F in replacement of three core cable, PVC insulated, unsheathed, multi stranded copper conductor cable of size 2.5 Sqmm complete all as specified and as directed.
S&F in replacement of for MCB SP 06 to 32 Amps 240 Volts, 10 KA, `B' curve, all as per site requirement and as directed by Engr-in-Charge.
S&F in replacement of MCB SP 40-63 Amp, 10kA breaking capacity, Series 'B' complete all as specified and as directed.
S&F in replacement of MCB SPN 32 Amps, 240 Volts, 10 KA, `B' curve, all as per site requirement and as directed by Engr-in-Charge.
S&F in replacement of MCB SPN 40 Amps, 240 Volts, 10 KA, `B' curve, all as per site requirement and as directed by Engr-in-
S&F in replacement of MCB SPN 63 Amps, 240 Volts, 10 KA, `B' curve, all as per site requirement and as directed by Engr-in-Charge.
S&F in replacement of MCB TPN/ Isolator 4P of 40 Amps 415 volts, 'B' Series 10 KA as per site requirement and as directed.
S&F in replacement of MCB TPN/ Isolator 4P of 63 Amps 415 volts, 'B' Series 16 KA as per site requirement and as directed.
S&F in replacement of MCB TPN/ Isolator 4P from 100/125Amps 415 volts, 'B' Series 25 KA as per site requirement and as directed.
S&F in replacement of MCCB TP 63/100 Amp, 415 Volts,16kA fixed type complete all as specified.
S&F in replacement of MCCB TP 125 Amp, 415 Volts ,16kA fixed type complete all as specified.
S&F in replacement of MCCB TP 160 Amp,415 Volts, 16kA adjustable type complete all as specified.
S&F in replacement of MCCB TP 250 Amp,415 Volts, 36kA adjustable type complete all as specified.
S&F in replacement of LED Batten fitting 10 watt - 2FT White, aluminium extruded complete all as specified and directed.
S&F in replacement of LED Batten fitting 20 watt - 4FT White, aluminium extruded complete all as specified and directed.
S&F in replacement of 06 watt aesthetically designed ceiling/surface mounting round shaped LED downlighter complete all as specified and directed. Note:-The make should match the existing LED light on ground.
S&F in replacement of 03 watt aesthetically designed circular shaped decorative ceiling LED light fitting complete all as specified and as directed.Note:-The make should match the existing LED light on ground.
S&F in replacement of 09 Watt Wall mounted decorative LED light fitting complete all as specified and as directed
S&F in replacement of 3.6 Watt aesthetically designed Wall mounted decorative mirror LED light fitting complete all as specified and as directed. Note:-The make should match the existing LED light on ground.
S&F in replacement of 09/12 Watt surface/ceiling mounted decorative downlighter LED light fitting complete all as specified and as directed. Note:-The make should match the existing LED light on ground.
S&F in replacement of 15/18 Watt surface/ceiling mounted decorative downlighter LED light fitting complete all as specified and as directed. Note:-The make should match the existing LED light on ground.
S&F in replacement Recessed mounting 36 Watt 2'x2' full glow essential LED panel fitting luminaire with suitable for indoor space and fix in existing POP including cutting/grouting of existing POP and get electrically connected the fitting with switch board for suitable size of PVC copper wire complete all as specified and directed.Note:-The make should match the existing LED light on ground.
S&F in replacement of 1x4 fullglow recess mounted LED panel light of 30 W luminaire with high transmitive diffuser suitable for indoor space complete all as specified and as directed.
S&F in replacement of LED inverter bulb 10 watt complete all as specified and as directed.
S&F in replacement of LED bulb 09 watt complete all as specified and as directed.
Supply only in replacement of test lamp bulb 100 watt complete all as specified and as directed.
S&F in replacement of inverter type LED Building security light fitting 25 watt including GI bracket of suitable size,fixing with clamp ,nut,bolt and other connected accessories complete all as specified and as directed.
S&F in replacement of 10 Watt, LED bulkheads light fitting complete with suitable driver complete all as specified and as directed.
S&F in replacement of decorative LED type post top lanterns luminaire 40 watts, outdoor type for 360 degree indirect light with resistant to corrosion, glare free with suitable driver complete all as specified and as directed
S&F in replacement of LED bollard luminaire 10 watts, inverted pyramid tripod type with soft 360 degree light outdoor type having resistant to corrosion with better optics for uniform distribution complete with suitable driver & fixing nuts, bolts & washers all as specified and directed
S&F in replacement of LED flood light luminaires 90 watts, 230 volts AC, outdoor type with pressure diecast housing resistant to impact and corrosion, glare free complete with lamp, driver complete all as specified and as directed.
S&F in replacement of LED driver suitable for 40 watt post top lantern fitting 40 watt LED lamp complete all as specified and as directed.(As per sample)
S&F in replacement of LED driver suitable for 10 watt bollard LED light complete all as specified and as directed.(As per sample)
S&F in replacement of LED driver suitable for 36 watt 2'X2' LED panel light complete all as specified and as directed.(As per sample)
S&F in replacement of LED driver suitable for 6-18 watts LED light(wall/ceiling) complete all as specified and as directed.(As per sample)
S&F in replacement of LED driver suitable for 90/120/130 watts flood LED light complete all as specified and as directed.(As per sample)
Taking down of old unserviceable ceiling fan/exhaust fan dismantling of blades, transportation to work shop and carrying out rewinding, transportation to site, reinstallation and testing Complete all as specified and directed by Engineer-in-charge. Note : Rewinding will be measured and paid separately under this Schedule.
M&L for Rewinding of ceiling fan 1200 mm sweep by dismantling of fan motor cutting and removing of burnt windings, cleaning, winding with supper enameled copper wire of superior quality, same gauge of wire, same Nos of turns, provn of insulation paper applying of varnish drying of varnish and assembling of fan including replacement gun metal bush where ever required Complete all as specified and directed by Engineer-in-charge. Note : The lathe machine work if necessary to making uppper/lower sheet of fan will be measured under this item only.
All as per ser item No 86 but 1400 mm sweep
All as per ser item No 86 but exhaust fan 230/300 mm sweep
All as per ser item No 86 but exhaust fan 450/600 mm sweep
S&F in replacement of ceiling fan Ball bearing of suitable size & model.
S&F in replacement of 'U' clamps with rubber reel, bolts, nuts, washers and safety pin ceiling fan of existing size.
S&F in replacement of Down rod of any height fabricated out of MS pipe 12mm dia heavy duty duly painted with one coat of white paint complete.
S&F in replacement of Canopy of Celing fans of 1200/1400mm swipe size heavy duty duly painted with one coat of white paint complete.
S&F in replacement of blade (Set of 3 blades) of Celing fans of 1200/1400mm swipe size duly painted with one coat of white paint complete
S&F in replacement of blade of exhaust/fresh air fans of 230/300/450 mm swipe size duly painted with one coat of paint of suitable colour complete.
S&F in replacement of metal frame of exhaust/fresh air fans of 230/300/450 mm swipe size duly painted with one coat of paint of suitable colour complete.(As per sample)
S&F in replacement of motor(copper winding) of exhaust/fresh air fans of 230mm swipe size duly painted with one coat of paint of suitable colour complete.(As per sample)
S&F in replacement of motor (copper winding) of exhaust fans of 300mm swipe size duly painted with one coat of paint of suitable colour complete.(As per sample)
S&F in replacement of motor (copper winding)of exhaust fans of 450mm swipe size duly painted with one coat of paint of suitable colour complete.(As per sample)
Supply only in replacement MS fastner bolt 8mm dia and 100mm (Min.) for fixing Exhaust fan/Bldg security light etc with nut and washer.
M&L for spray painting two coat (white colour) with synthetic enamel paint to Ceiling fans/Exahust fan of any capacity to reach upto satisfied finish of painting after cleaning and preparation of surface complete all as specified and directed by Engineer-in-charge.
Taking down geyser 25ltrs capacity of any make, opening up complete for inspection descalling by chemical treatment of internal tank , themrostate pipe, base plate assembly carrying out minor repairs including replacement of gaskets testing and refixing in position including making electrical and water connection complete all as specified and directed by Engineer-in-Charge.
M&L for spray painting two coat (white colour) with synthetic enamel paint to Geysers 25 Liters capacity to reach upto satisfied finish of painting after cleaning and preparation of surface complete all as specified and directed by Engineer-in-charge.
S&F in replacement heating element Bajaj type 1.5 KW (circular/square/triangular) as required at site as per sample for any make of geyser including rubber washers complete all as specified and directed. Note:-The make should match the existingheating element on ground.
S&F in replacement 25 Ltr inner stainless steel tank suitable for 25 Ltr storage water heater complete all as specified and directed.
S&F in replacement of insulating material (Glass wool) for 25 litre capacity Geysers all as directed by Engineer -in - charge.
S&F in replacement of base plate assembly (As per sample) as required at site heavy duty suitable for 25 litre capacity stainless steel tank geyser with inlet, outlet and thermostat pipe with drain plug and screw for fixing the assembly including clamps for holding the assembly with nuts, bolts,packing and safety valves suitable for all type of geysers installed at site.
S&F in replacement of chromium plated connection pipe of required length with two brass adopters washers and connecting up complete all as specified and directed.
S&F in replacement of PVC connection pipe of required lenth with two brass adopters washers and connecting up complete ISI mark all as specified and directed by Engr-in Charge
S&F in replacement of safety nut for high pressure release.
S&F in replacement of non return valves 15mm dia and connecting up complete (ISI marked).as per sample
S&F in replacement of Top & Bottom cover body suitable for 25 Ltrs storage water storage heater made of MS sheet complete as per site requirement all as specified & directed by Engineer-in-Charge.
S&F in replacement of outer body for geyser made out of MS sheet suitable for 25 ltrs capacity geyser vertical/horigontal type all as specified and directed.
S&F in replacement of thermostat (As per sample) as required at site for 25 Liters capacity Geyserof any make/model.
S&F in replacement of indicator lamp (Red & Green) 230 volts suitable for Geyser (as per sample)
S&F in replacement of of mild steel hole fastner 10mm dia, 100mm long including nut and washer.
S&F in replacement of metal clad plug top 20 Amp, 230 volts AC all as specified.
S&F in replacement of metal clad socket outlet 20 Amps, 230 volts AC all as specified.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. and making good disturbed surfaces of walls, floors etc.
M&L for point wiring complete, stranded copper conductor 1.5 Sqmm nominal area PVC insulated FRLSH 1100 volts grade electrical cable in but with through existing concealed PVC/ MS conduit and including replacement of unserviceable pressed steel terminal boxes of required size with top cover 3 mm thick laminated sheet of required color with screwed and cup washer with all accessories including 1.5 sqmm stranded copper conductor PVC unsheathed cable earth wire to common earth and connected to earth dolly complete all as specified for One light/Fan/Bell point controlled by one switch 5 Amps one way using cable (1.5 Sq mm for phase and neutral and 1.5 sqmm for earthing) including cutting chasing and making good to disturbed surface of walls including necessary touch up with adjoining surface of disturbed area i.e with OBD/colour work/white wash as existing finishes complete all as specified and directed by Engr-in-Charge. Note :- wiring should be done in existing conduit. New conduit will be added where there is a burnt/blokage/damage to the existing conduit including bends/elbows/tees/Junction boxes.
One light / fan/bell point controlled by one switch SP, one way, 230 volts.
One 3 pin socket outlet 5/6 Amps on same board.
One socket outlet 5/6 Amps on independent board.
One power socket 15/16 Amp but with cable 2.5 Sqmm for phase & neutral and for earth 2.5 sqmm.
S&F in replacement of PVC Casing Caping of size 1" complete all as specified & directed.
S&F in replacement of PVC conduit 20mm dia, rigid, complete all as specified & directed.
S&F in replacement of flexible PVC pipe of 20mm dia rigid complete all as specified & directed.
S&F in replacement of submain wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLSH type, 1100 volts grade 2 x 4 sqmm complete drawn in existing conduit along with 1x 4 sqmm PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type for continuous earth wire and connected to common earth dolly complete all as specified Note :- New conduit of suitable size with connected fitting will be laid if there is a burnt/blokage/damage to the existing conduit including bends/elbows/tees/Junction boxes including making good to disturbed surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
S&F in replacement of submain wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLSH type, 1100 volts grade 2 x 6 sqmm complete drawn in existing conduit along with 1x 6 sqmm PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLSH type for continuous earth wire and connected to common earth dolly complete all as specified. Note :- New conduit of suitable size with connected fitting will be laid if there is a burnt/blokage/damage to the existing conduit including bends/elbows/tees/Junction boxes including making good to disturbed surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
S&F in replacement of submain wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 10 sqmm complete drawn in existing conduit along with 1x 10 sqmm PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLSH type for continuous earth wire and connected to common earth dolly complete all as specified. Note :- New conduit of suitable size with connected fitting will be laid if there is a burnt/blokage/damage to the existing conduit including bends/elbows/tees/Junction boxes including making good to disturbed surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
S&F in replacement of metal clad enclosure with plug and socket 20 Amp with one MCB SP upto 20 Amps 230 volts AC all as specified.
S&F in replacement of factory made concealed sheet steel distribution boards, double door, SPN, 4 way, 230 volts AC, IP 43 with suitable busbar, neutral link, earth link suitable for MCB, DP/SPN as incomer & MCB SP as outgoing all as specified.
S&F in replacement of factory made concealed sheet steel distribution boards, double door, SPN, 8 way, 230 volts AC, IP 43 with suitable busbar, neutral link, earth link suitable for MCB, DP/SPN as incomer & MCB SP as outgoing all as specified.
S&F in replacement of factory made concealed sheet steel distribution boards, double door, SPN, 12 way, 230 volts AC, IP 43 with suitable busbar, neutral link, earth link suitable for MCB, DP/SPN as incomer & MCB SP as outgoing all as specified.
S&F in replacement of factory made load line DB's double door made out of CRCA mild steel sheet with insulating materials like polyester epoxy coated surface mounting 4 way VTPN 415 Volts, IP 43 with suitable busbar, neutral link & earth link suitable for MCCB TP as incomer & MCB SP/TP as out going complete all as specified.
S&F in replacement of factory made load line DB's double door made out of CRCA mild steel sheet with insulating materials like polyester epoxy coated surface mounting 8 way VTPN 415 Volts, IP 43 with suitable busbar, neutral link & earth link suitable for MCCB TP as incomer & MCB SP/TP as out going complete all as specified.
S&F in replacement of Exhaust fan Louvers 230/300 mm Size, including taking out old louvers up to fourth floor complete all as specified.Note:-Staircase arrangement for fixing louvers will be made by contractor.
Comprehensive, preventive and periodical maintenance of ice cube making machine (02 Nos) of capacity 140 Kg per 24 Hrs Make: Scotsman installed at NOM-Varuna in reliable, safe and efficient manner by regular examining, lubricating and adjusting the mechanical ,electrical and refrigerant parts including repacement of defective / spares parts and testing on completion to the entire satisfaction of Engr-in-charge complete all as specified. (Note:- (i) Fixing charge is deemed to be included in this item .(ii) All the complaints will be rectify within 24 hrs from the time of receipt of complaint. If contractor fails to rectify the complaint within 24 hrs from the time of receipt of complaint, the compensation / penalty of Rs 500.00 per complaint per day shall be recovered from the contractor's dues.) (iii) all the parts of the machine are covered under this items for the smooth functioning of ice cube making machine and the contractor may quote the rate accordingly. Contractor is expected to inspect the Machine at NOM Varuna before quoting the rate.
M& L for servicing,cleaning,oiling, greasing including replacement of necessary defective spares parts of air curtains and repair of motor/compressor/blower of air curtains complete all as specified and directed by Engr-In-Charge.
M&L for Earthing complete with galvanized steel earth plate 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate n.less than 1.5 m below normal ground level, connected to galvanized iron wire 4 mm as earthing lead by means of bolts, nuts, check nuts & washers of galvanized iron or steel besides building at all joints as shown in drgs and including excavation and earth work, GI pipe light grade 25mm bore of protection of GI wire from earth electrode, supply and laying charcoal dust, common salt, PCC (1:2:4) type B-1 Chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type B-1using 20 mm graded stone aggregate Reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia , PGI funnel and wire mesh , 20 mm dia GI Pipe light grade for watering complete all as directed by Engr-in-Charge.
RAJDHANI ENTERPRISES
m/s VK construction company
RUCHIKA ENGG.WORKS
SANJEEV ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .