| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹16.2 LAccepted-AOC NO 235 PSK ILLAM SANKARAN NAGAR CHINNAMMAN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | 1 | Accepted-AOC BEING LOWEST TENDERER AND FULFILLING ALL THE REQUISITE CRITERIA | |
| 2 | 2₹17.5 L+₹53,569 (3.16%)Rejected-Finance 1001 63 SHALIMAR GARDEN ISMAILGANJ NEAR INDIRA NAGAR SECTOR 08 CROSSING LUCKNOW 226016 | LUCKNOW | UTTAR PRADESH | 226016 | 2 | Rejected-Finance NOT BEING LOWEST TENDERER | |
| 3 | 3₹18.3 L+₹1.3 L (7.80%)Rejected-Finance 63 2ND MAIN ROAD NGO COLONY ADAMBAKKAM CHENNAI 600 088 | CHENNAI | CHENNAI | TAMIL NADU | 600088 | 3 | Rejected-Finance NOT BEING LOWEST TENDERER | |
| 4 | 4₹23.5 L+₹6.6 L (38.8%)Rejected-Finance 53 13 A OUTER CIRCULAR ROAD KILPAUK GARDEN COLONY CHENNAI 600 010 | CHENNAI | CHENNAI | TAMIL NADU | 600010 | 4 | Rejected-Finance NOT BEING LOWEST TENDERER | |
| 5 | 5₹30.8 L+₹13.8 L (81.4%)Rejected-Finance NO 23 SECOND MAIN ROAD RAJAMMAL NAGAR MADAMBAKKAM CHENNAI 600 126 | CHENNAI | CHENGALPATTU | TAMIL NADU | 600126 | 5 | Rejected-Finance NOT BEING LOWEST TENDERER |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
7 Dec 2023, 6:55 pmClosed
GE CHENNAI
GE CHENNAI FORT ST GEORGE CHENNAI 600009
REPAIRS/REPLACEMENT OF INTERNAL WIRING, FITTINGS, FIXTURES AND CONNECTED WORKS AT C AND E AREA UNDER GE CHENNAI
2023_MES_627088_1
8706
Open Tender
Civil Works
Item Rate
275 days
CHENNAI
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE CHENNAI
₹70,000
Yes
2 Mar 2024
6 Nov 2023
14 Dec 2023
6 Nov 2023
7 Dec 2023
23 Nov 2023
Amount
Taking down carefully copper/aluminium point wiring light, fan, socket or power complete with fittings such as switches, ceiling roses, regulators sockets etc and making good disturbed surfaces of walls, floors to match with the existing surface complete all as specified and directed .
Taking down carefully by unserviceable fittings of any description complete and making good disturbed surfaces of walls, floors to match with the existing surface complete all as specified and directed .
M&L for point wiring of size 1.5 sqmm with PVC insulated unsheathed multistranded copper conductor cable of 1100V grade drawn through new non metallic rigid PVC conduit including accessories, concealed in wall/floor and fixed on ceiling/roof etc, including pressed steel terminal boxes concealed in walls for housing modular switchs,sockets, fan regulators etc., incl provn of 1.5 sqmm PVC insulated copper earth conductor cable for earth continuity and connecting to common earth dolly complete all as specified and directed for :-
one light point controlled by one switch
one fan point controlled by one switch
one 3 pin socket outlet 5 amps on the same board controlled by one switch.
one 3 pin socket outlet 5 amps on independent board controlled by one switch.
one light point controlled by two nos of two switches
one bell/buzzer point controlled by one bell push
As per above items No 3 for one socket outlet three pin 15 amps control by one switch independent board with cable 2.5 sqmm size complete all as specified and directed.
M&L for point wiring of size 1.5 sqmm (two run) with PVC insulated unsheathed multistranded copper conductor cable of 1100V grade drawn through non metallic rigid Existing PVC conduit , in wall/floor and fixed on ceiling/roof etc, including pressed steel terminal boxes concealed in walls for housing modular switchs,sockets, fan regulators etc., incl provn of 1.5 sqmm PVC insulated copper earth conductor cable for earth continuity and connecting to common earth dolly complete all as specified and as directed for :-
one light point controlled by one switch
one fan point controlled by one switch
one bell/buzzer point controlled by one bell push
one 3 pin socket outlet 5 amps on the same board controlled by one switch.
one 3 pin socket outlet 5 amps on independent board controlled by one switch.
one light point controlled by two nos of two way switches.
As per above items No 5 for one socket outlet three pin 15 amps control by one switch independent board with cable 2.5 sqmm size complete all as specified and directed.
M&L for point wiring of size 1.5 sqmm (two run) with PVC insulated unsheathed multistranded copper conductor cable of 1100V grade drawn through non metallic rigid surface PVC conduit , in wall/floor and fixed on ceiling/roof etc, including pressed steel terminal boxes concealed in walls for housing modular switchs,sockets, fan regulators etc., incl provn of 1.5 sqmm PVC insulated copper earth conductor cable for earth continuity and connecting to common earth dolly complete for :-
one light point controlled by one switch
one fan point controlled by one switch
one bell/buzzer point controlled by one bell push
one 3 pin socket outlet 5 amps on the same board controlled by one switch.
one 3 pin socket outlet 5 amps on independent board controlled by one switch.
one light point controlled by two nos of two way switches
As per above items No 7 for one socket outlet three pin 15 amps control by one switch independent board with cable 2.5 sqmm size
M&L for point wiring of size 1.5 sqmm (two run) with PVC insulated unsheathed multistranded copper conductor cable of 1100V grade drawn through new non metallic rigid PVC casing caping in wall/floor and fixed on ceiling/roof etc, including pressed steel terminal boxes concealed in walls for housing modular switchs,sockets, fan regulators etc., incl provn of 1.5 sqmm PVC insulated copper earth conductor cable for earth continuity and connecting to common earth dolly complete all as specified and directed for :-
One light point controlled by one switch
One fan point controlled by one switch
One 3 pin socket outlet 5 amps on the same board controlled by one switch.
One 3 pin socket outlet 5 amps on independent board controlled by one switch.
One bell/buzzer point controlled by one bell push
As per above items No 9 for one socket outlet three pin 15 amps control by one switch independent board with cable 2.5 sqmm size (two run).
S& F for modular metal flush box 2 module complete all as specified and directed.
S& F for modular metal flush box 4 module complete all as specified and directed.
S& F for modular metal flush box 6 module complete all as specified and directed.
S& F for modular cover plate with frame 2 module complete all as specified and directed.
S& F for modular cover plate with frame 4 module complete all as specified and directed.
S& F for modular cover plate with frame 6 module complete all as specified and directed.
S&F modular switches suitable for type AC 240V, 6 amps 1 module complete all as specified and directed.
S&F modular sockets suitable for type AC 240V, 6 amps 2 module complete all as specified and directed.
S&F modular switches two way suitable for type AC 240V, 6 amps 1 module complete all as specified and directed.
S&F modular switches suitable for type AC 240V, 16 amps 1 module complete all as specified and directed.
S&F modular power sockets suitable for type AC 240V, 16 amps 2 module complete all as specified and directed.
S&F modular fan regulator suitable for type AC 240V, 2 module complete all as specified and directed.
S&F modular bell switch suitable for type AC 240V, 06 amps complete all as specified and directed.
S&F call bell of multi music type A/C 230 volts complete all as specified and directed.
S&F ceiling rose , polycarbonate, isolated body with 2 to 3 terminals complete all as specified and directed.
Taking down ceiling fan carrying out repairs by rewinding of ceiling fan with enamelled copper wire with suitable gauge and insulating material including varnishing with suitable class of insulating varnish ,painting with two coats of synthetic enamel paint and writing MES number , including replacement bushes/bolt and nuts etc and connecting with twin core flexible cord from ceiling rose and testing complete all as specified and as directed.
Taking down Exhaust fan carrying out repairs by rewinding of exhaust fan with enamelled copper wire with suitable gauge and insulating material including varnishing with suitable class of insulating varnish ,painting with two coats of synthetic enamel paint and writing MES number , including replacement bushes/bolt and nuts etc and connecting with twin core flexible cord from ceiling rose and testing complete all as specified and as directed.
S&F lamp holder insulated body with back plate for batten fittings/angle holder complete all as specified and directed.
S&F of LED bulb 9 w high suitable for lamp holder complete all as specified and as directed. Make : Havells/CG/Philips /Wipro
Supply and fix 20Watts LED light fitting, basic all purpose surface and wall mounted LED batten 20Watts with aluminium housing and integrated electronic driver including 20W LED tube - 1No on surfaces of wall or ceiling including taking down the old fitting complete all as specified and as directed. Make Havells as per cat No: LUMILINEPLUSNEOBS20W LED865SPCSSIND or techno commercial equivalent in Philips /Bajaj/Crompton/Wipro
Supply and fix 10Watts LED light fitting, basic all purpose surface and wall mounted LED batten 10Watts with aluminium housing and integrated electronic driver including 10W LED tube - 1No on surfaces of wall or ceiling including taking down the old fitting complete all as specified and as directed. Make Havells as per cat No: LUMILINEPLUSBS10W LED865SPCSSIND or techno commercial equivalent in Philips /Bajaj/Crompton/Wipro
Supply and fix 36 Watts 2X2 ceiling light Environment friendly, new generation, aesthetically, ultra modern designed Recess mounting luminaire with high brightness SMD LEDs as light source suitable for Armstrong/Grid ceiling including taking down the old fitting complete all as specified and as directed. Make Havells as per cat No: VENUSNEO 2X2PLR36WLED865G2 or techno commercial equivalent in /Philips /Bajaj/ Crompton/Wipro
S&F in repairs switch piano flush type 5 amps single pole one way including taking down unserviceable complete all as specified and directed.
S&F in repairs switch piano flush type 5 amps single pole two way switch including taking down unserviceable complete all as specified and directed.
S&F in repairs socket outlet 2 in 1, 3pin 5 amps 230 volts including taking down unserviceable complete all as specified and directed.
S&F switch piano flush type 15 amps single pole one way including taking down unservicable complete all as specified and directed.
S&F in repairs socket outlet 3 pin, 15 Amp, flush type including taking down unserviceable complete all as specified and directed.
S&F in repairs bell push 5 amps 230 volts flush type including taking down unserviceable complete all as specified and directed.
S&F in repairs Electronic fan regulator dimmer type,450w , 240 volt including taking down unserviceable complete all as specified and directed.
Taking down sub main wiring any type and any size complete after taking proper disconnecting of electric supply properly and making good surface complete all as specified and directed
S&F sub main wiring complete with two runs of 4 sqmm PVC insulated unsheathed single core multistrand copper conductor cable of 1100 volts grade drawn through new non metallic rigid PVC conduit pipe concealed in wall along with accessories fixed on walls/floors/ceiling with one run of 4 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor all as specified and directed. Note:- Two runs of PVC insulated cable 4 sqmm + one run 4 sqmm of earth wire and one run of conduit including accessories shall be measured as one length.
S&F sub main wiring complete with two runs of 4 sqmm PVC insulated unsheathed single core multistrand copper conductor cable of 1100 volts grade drawn through new non metallic rigid PVC casing capping on wall along with accessories fixed on walls/floors/ceiling with one run of 4 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor all as specified and directed. Note:- Two runs of PVC insulated cable 4 sqmm + one run 4 sqmm of earth wire and one run of conduit including accessories shall be measured as one length.
S&F sub main wiring complete with two runs of 4 sqmm PVC insulated unsheathed single core multistrand copper conductor cable of 1100 volts grade drawn through new non metallic rigid Existing PVC conduit on wall along with accessories fixed on walls/floors/ceiling with one run of 4 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor all as specified and directed. Note:- Two runs of PVC insulated cable 4 sqmm + one run 4 sqmm of earth wire and one run of conduit including accessories shall be measured as one length.
Taking down AC box any type and any size complete after taking proper disconnecting of electric supply properly and making good surface complete all as specified and directed
S&F for modular 25 Amp motor starter AC switch with two module with socket 25 Amp including indication both red and green complete all as directed. Make Legrand cat No 673031 or equivalent in ANCHOR/HAVELLS
Earthing complete with galvanised steel earth plate electrode 60cm x 60 cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25m deep below ground level with top edge of plate not less than 1.5 below ground level connected to GI 4 mm earth wire by means of bolts, nuts check nuts washers made of galvanised iron or steel earth wire protected by GI pipe 15 mm bore light grade connected upto switch board incl 20mm bore GI water pipe with funnel and wire mesh all as shown in electrical plate No.3 of SSR Part I including dearth chamber of PCC 1:2:4 type B1 using 20mm grade aggregate with RCC cover slab 1:2:4 type B1, 40mm thick with 15mm dia MS bar 100mm C/C both ways and 6 MM dia MS hooks complete all as specified including testing on completion.
RK ENTERPRISES
EVEREST ENGINEERING WORKS
M/s.Sai Agency
PREMIER ENGINEERING SYSTEMS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .