| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹42.6 L+₹1.7 L (4.07%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹43.3 L+₹2.4 L (5.81%)Rejected-Finance 70 SUBHASH ROAD HARJINDER NAGAR KANPUR 208007 | KANPUR | KANPUR | UTTAR PRADESH | 208007 | L3 | Rejected-Finance Being L3 |
| Sl No | Description | Qty | Unit | M/S SHIVA CONSTRUCTION L3 | M/S ANIL ARORA L2 | AJAY CONSTRUCTION L1 |
|---|---|---|---|---|---|---|
| 1.00 | Taking down cement plaster of any description on brick or stone masonry wall , etc including racking out joints, hacking for key, scrubbing down with water etc, all as specified. | 960 | Sqm | 10 ₹9,600 | 10 ₹9,600 | 5 ₹4,800 Lowest |
| 2.00 | M&L for Rendering 15 mm thick in cement and sand mortar 1:4 on brick work or cement concrete wall surfaces including mixing only water proofing compound as per manufacturers instruction and finishing the surface even and smooth without using extra cement complete all as specified.
Note:- Waterproofing compound will be measured and paid separately. | 200 | Sqm | 160 ₹32,000 Lowest | 170 ₹34,000 | 160 ₹32,000 Lowest |
| 3.00 | M&L for Rendering 15 mm thick in cement and sand mortar 1:4 on brick work or cement concrete wall surfaces and finishing the surface even and smooth without using extra cement complete all as specified. | 400 | Sqm | 155 ₹62,000 Lowest | 170 ₹68,000 | 170 ₹68,000 |
| 4.00 | M&L for Rendering 15 mm thick in cement and sand mortar 1:6 on brick work or cement concrete wall surfaces including finishing the surface even and smooth without using extra cement complete all as specified. | 300 | Sqm | 155 ₹46,500 | 160 ₹48,000 | 150 ₹45,000 Lowest |
| 5.00 | M&L for 5 mm thick rendering in cement mortar 1:3 on concrete surface of ceiling, finished even and smooth without using extra cement. | 60 | Sqm | 145 ₹8,700 Lowest | 150 ₹9,000 | 230 ₹13,800 |
| 6.00 | M&L for Preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed by Engineer-in-Charge | 60 | Sqm | 18 ₹1,080 | 15 ₹900 Lowest | 20 ₹1,200 |
| 7.00 | M&L for preparing new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint (first Quality) over one coat of red oxide primer complete all as specified. | 50 | Sqm | 60 ₹3,000 | 45 ₹2,250 Lowest | 60 ₹3,000 |
| 8.00 | M&L for preparation of old painted wood and wood based surfaces of any description, not otherwise described over 10 cm width or girth, including knotting and stopping holes and applying one coat of synthetic enamel paint (first Quality) complete all as specified and directed by Engineer-in-Charge | 120 | Sqm | 48 ₹5,760 | 35 ₹4,200 Lowest | 40 ₹4,800 |
| 9.00 | M&L for preparation of old painted surfaces of steel of any description, not otherwise described over 10 cm width or girth, and applying one coat of synthetic enamel paint (first Quality) complete all as specified and directed by Engineer-in-Charge | 70 | Sqm | 50 ₹3,500 | 35 ₹2,450 Lowest | 45 ₹3,150 |
| 10.00 | M&L for complete removal of existing treatment from internall wall surfaces including facia, cornices etc to make surface clean, free from dust, loose paint etc complete all as specified & directed | 950 | Sqm | 15 ₹14,250 | 10 ₹9,500 Lowest | 20 ₹19,000 |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
8 Nov 2025, 6:53 amClosed
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
REPAIR B/R MAINT WORKS IN ELECTRICAL INSATALLATION AND DG SET INSTALLATIONS CONSISTING OF PLASTERING CABLE DUCTING HARDSTANDING SMART PERIODICAL SERVICES ROOF TREATMENT AND CERTAIN ALLIED WORKS IN THE AREA OF AGE EM EXT (ELECT) UNDER GE EM LUCKNOW
2025_MES_736051_1
GE/EM/LKO/EXT(ELECT)/T-44 OF 2025-2026
Open Tender
Civil Works
Item Rate
180 days
Lucknow
As per NIT
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹99,000
Yes
12 Dec 2025
18 Oct 2025
10 Nov 2025
18 Oct 2025
8 Nov 2025
1 Nov 2025
Amount
Taking down cement plaster of any description on brick or stone masonry wall , etc including racking out joints, hacking for key, scrubbing down with water etc, all as specified.
M&L for Rendering 15 mm thick in cement and sand mortar 1:4 on brick work or cement concrete wall surfaces including mixing only water proofing compound as per manufacturers instruction and finishing the surface even and smooth without using extra cement complete all as specified. Note:- Waterproofing compound will be measured and paid separately.
M&L for Rendering 15 mm thick in cement and sand mortar 1:4 on brick work or cement concrete wall surfaces and finishing the surface even and smooth without using extra cement complete all as specified.
M&L for Rendering 15 mm thick in cement and sand mortar 1:6 on brick work or cement concrete wall surfaces including finishing the surface even and smooth without using extra cement complete all as specified.
M&L for 5 mm thick rendering in cement mortar 1:3 on concrete surface of ceiling, finished even and smooth without using extra cement.
M&L for Preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed by Engineer-in-Charge
M&L for preparing new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint (first Quality) over one coat of red oxide primer complete all as specified.
M&L for preparation of old painted wood and wood based surfaces of any description, not otherwise described over 10 cm width or girth, including knotting and stopping holes and applying one coat of synthetic enamel paint (first Quality) complete all as specified and directed by Engineer-in-Charge
M&L for preparation of old painted surfaces of steel of any description, not otherwise described over 10 cm width or girth, and applying one coat of synthetic enamel paint (first Quality) complete all as specified and directed by Engineer-in-Charge
M&L for complete removal of existing treatment from internall wall surfaces including facia, cornices etc to make surface clean, free from dust, loose paint etc complete all as specified & directed
M&L for preparation of new plastered surfaces / surface obtained after removal of existing treatment of walls and applying two coats of oil bound distemper (first Quality) over one coat of primer over and including 2 mm to 3 mm thick cement base wall care putty complete all as specified and directed by Engineer-in-charge.
Deployment of manpower & tools etc for Complete removal of existing treatment on wall / roof projections including facia, cornices etc by scrapping with mechanical sander (having mechanical vacuum mechanism) with sanding pad of appropriate grit to make surface clean, free from dust, loose paint etc by skilled labour complete all as specified and directed.
M&L for applying minimum 1 mm thick exterior grade wall care putty over prepared plastered wall surface to achieve the surface even and smooth for application of painting complete all as specified and directed.
Material & Labour for applying two coats of 100% Premium acrylic emulsion paint, having VOC less than 50 gm / litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre / 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre / 10 sqm over on putty applied surfaces of walls, primer & paint shall be applied by air less spray machine (Mechanical means) complete all as specified & directed.
M&L preparation of old painted surface of walls and applying one coat of 100% Premium acrylic emulsion paint, having VOC less than 50 gm / litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre / 10 sqm complete all as specified & directed.
Demolition of brick work or stone / boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and pre cast concrete articles complete all as specified and directed.
M&L for Brick work with Fly ash brick designation 100 Kg / Sqcm, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, using bricks of size 230 mm x 110 mm x 75 mm confirming to IS 12894, complete all as specified and as directed by Engineer-in-Charge.
M&L for Brick work in half brick thick wall with Fly ash brick designation 100 Kg / Sqcm, straight or curved on plan exc 6 m mean radius built in cement mortar 1:4, using bricks of size 230 mm x 110 mm x 75 mm confirming to IS 12894, complete all as specified and as directed by Engineer-in-Charge.
Dimolition of stone slab of any description / thickness in floors, aprons etc including cement mortar bedding laid bedded and pointed in any mortar, including removal of debries to a distance exc 1.5 km but n.exc 5 Km complete all as specified and directed.
M&L for 18 to 20 mm thick granite slab (of any type) machine cut & machine polished, set & jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone laid over and including screed bed 15 mm thick in cement mortor 1:4 complete all as specified and directed.
M&L for 75 mm thick plain cement concrete 1:4:8, type D- 2, using 40 mm graded stone aggregate as in sub base complete all as specified and directed.
Dimolition of stone slab / tiles and similar work of any description / thickness in floors, aprons etc laid & bedded dry including removal dry sand screed complete all as specified and directed.
M&L for 60 mm thick factory made chamfered edge cement concrete interlocking paver block of M-35 grade, in gray cement with approved design & pattern / shape laid as in foot path, / hard standing / drive ways or parking etc., made by table vibratory method using PU mould, laid over and including 20 mm thick compacted bed of fine sand, compacting and proper embedding / laying of inter locking paver blocks over the the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed.
Laying & fixing only of inter locking PCC paver block of any descreption, laid as in foot path / hard standing / drive ways or parking etc., laid over and including 20 mm thick compacted bed of fine sand, compacting and proper embedding / laying of inter locking paver blocks over the the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed. Note:- servicable Interlocking paver blocks retrived from demolition shall be used.
M&L for chequered cement concrete tiles of size 30 cm x 30 cm x 20 mm thick, with grey cement and pigment set & jointed with gray cement slurry and pointed with gray cement & pigment laid over and including 20 mm thick screed bed in CM 1:4 as in floors complete all as specified.
Demolition of cement concrete (un-reinforced) in ground floors and paving n. exc 15 cm thickness (below or above ground level), complete all as specified and directed.
M&L for plain cement concrete 1:2:4, type B-1, using 20 mm graded stone aggregate as in roof kerbs or mud stops or similar work rounded or chamfered on edges complete all as specified and as directed by Engineer-in-charge.
Dismantling of RCC posts, struts of any section including taking out embedded portion in concrete or brick masonry of any position place including swan neck fencing and making good to disturbed portion all as specified.
M&L for mild steel work in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165, complete all as specified and directed.
M&L for PCC 1:3:6, type C2, using 40 mm graded stone aggregate, as in foundation, filling and mass concrete complete all as specified and directed.
S&F Framed work such as grills, gratings, etc. with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290, Gde-E-165
S&F Mild steel screw bolts (machine made) of 10mm dia of sank with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified and directed.
Dismantling fencing wire mesh any type complete all as specified and directed.
Fixing only chain link fencing of description fixed to steel post with mild steel flat & nut bolt etc. Note: (i) Supply only fencing, will be measured and paid separately. (ii) Supply and fix mild steel nut bolt, line wire and flat will be measured and paid separately.
Supply only chain link fencing made out of mild steel galvanised wire of size & aperture approved by the Engineer - in - Charge, conforming to IS 2721 all as specified & directed. Note:- Fixing only fencing will be measured and paid separately.
Excavating in post holes (or similar holes) in soft/lose soil each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed by Engineer -in- Charge
S&F in repair Galvanised, 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and directed. (Note :- Each line wire to be measured)
Temporarily blocking of inlet of septic tanks / manhole of depth 0.50 to 1.5 metre with suitable wooden plugs / gunny bags and pumping / bailing out effluent and taking out / removing the accumulated sludge soil sewage / any other foreign / foul materials etc (solid / semisolid) from the septic tanks / manholes, complete and cleaning the septic tank / manholes with fresh water by mechanically / manually including taking out the blocking arrangements of inlet and making the system functional all as specified and directed by Enginee-in-Charge.
Temporarily blocking of inlet of septic tanks / manhole of depth 1.50 to 4.50 metre with suitable wooden plugs / gunny bags and pumping / bailing out effluent and taking out / removing the accumulated sludge soil sewage / any other foreign / foul materials etc (solid / semisolid) from the septic tanks / manholes, complete and cleaning the septic tank / manholes with fresh water by mechanically / manually including taking out the blocking arrangements of inlet and making the system functional all as specified and directed by Enginee-in-Charge.
Temporarily blocking of 150 mm bore sewage line with suitable wooden plugs / gunny bags and cleaning the same by rodding and removing the sludge alongwith brick bats / stones / broken bottles / any other foreign materials etc complete and cleaning the sewage line with fresh water by mannually / mechanilly as directed by EIC, and taking out the blocking arrangements of inlet and making the system functional all as specified and directed.
Temporarily blocking of 200 mm bore sewage line with suitable wooden plugs / gunny bags and cleaning the same by rodding and removing the sludge alongwith brick bats / stones / broken bottles / any other foreign materials etc complete and cleaning the sewage line with fresh water by mannually / mechanilly as directed by EIC, and taking out the blocking arrangements of inlet and making the system functional all as specified and directed.
Demolition of existing roof treatment of any type, including screed bed etc complete all as specified and directed.
M&L for 15 mm thick screed bed in cement mortar 1:4 over RCC roof slab including mixing only water proofing compound as per manufacturer instruction complete all as specified and directed by Engineer-in-Charge. (WPC will be measured and paid separately)
M&L for water proofing treatment on roof surfaces in the following manner:- (a) The surfaces shall be painted with hot bitumen grade 30/40 confirming to IS-73 @ 1.20 kg / sqm over a coat of bituminous primer conforming to IS-3384 @ 0.30 ltr /sqm. (b) Supply & lay 3 mm thick APP water proofing membrane reinforced with non woven polyester matt laid using bitumen torch by torch application with a side lap of 10 cm & 15 cm end lap weighing not less than 3.5 kg / sqm. Note: - (i) Work to be carried out through authorised applicators of the manufactures and work will be carried out in complete / in patches in roofs (ii) Contractor shall submit written guarantee of 10 years from date of completion & submit security deposit @ 2.5% of executed amount or Rs 6250.00 which ever is more.
Note For Item No 44 (iii) WPT INFORMATION PLAQUE. All buildings where water proofing treatment carried out shall be provided with “WPT Information plaque” of adequate size on wall of building. “WPT Information plaque” shall be of provided with base coat with 2 coat white synthetic enamel paint over one coat primer. Following information shall be mention with 2 cm height letter, numbers painted with black synthetic enamel paint all as directed by the Engineer-in-Charge. Quoted rate by the contractor against water proofing items shall be deemed to include cost of said “WPT Information plaque” 1. CA No --------------------------------- 2. Name of Contractor ---------------------- 3. Date of completion of work --------------- 4. Date of Expiry of waterproofing treatment ----------- 5. Name of Sub division -----------
Supply only water proofing compound of approved quality complete all as specified and directed by Engineer-in-Charge
M&L for preparation of untreated surface of APP membrane of any description over 10 cm in width or girth, not otherwise described and applying two coat of aluminium paints over one coat primer complete all as specified and directed.
S&F in repairs 110 mm outer dia PVC (SWR) pipes, single socketed, in any length with rubber ring joints, fixed to walls or floors including PVC clamp complete all as specified and as directed
Demolition of floor, hearth or wall tiling or stone slab laid, bedded & pointed in any mortar including demolition of cement mortar bedding or backing coat, including removal of debries from site.
M&L for premium / 1st quality non skid ceramic tiles of 7-8 mm (square or rectangular) area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles laid over and including 15 mm thick screed in CM 1:6, complete all as specified and directed.
M&L for premium / 1st quality glazed ceramic tiles in vertical surfaces 300 mm x 450 mm x 7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles laid over and including 10 mm thick screed in CM 1:3, complete all as specified and directed.
M&L for premium / 1st quality vitrified ceramic tiles 8-10 mm thick (square / rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floor etc. set and jointed in neet cement slurry and pointed white or coloured cement to match the shade of the tiles, laid over and including 15 mm thick screed bed in CM 1:6, complete all as specified and directed.
S&F in repairs 15 mm bore tubes, 'medium grade', galvanised, with all fitting; ( such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs, unions etc) and fixed to wall / ceiling with clips, wall hooks, wooden plugs or laid in floors including screwing and waste and for forged bends on piping as required, complete all as specified.
Supply and fix in repair 500 litres capacity double layer, rotational moulded, polythene water storage tank (Cylindrical vertical with closed top) hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and including 20 mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe complete.
Disconnecting existing tank of capacity 500 ltrs, setting aside or lowering if required and reconnecting or refixing in same positing or other position, including cleaning and removing all scale and dirt etc from tanks and from the mouths of circulating pipes etc complete all as specified .
S&F in repairs 15 mm size Bib taps, cast iron with crutch handle, screwed for 15 mm bore dia. iron pipe or for brass ferrule and fixed complete all as specified and directed.
Taking down chowkats or frame, (without taking off shutter from the frame) area not exceeding 1.5 sqm each complete all as specified and directed by Engineer-in-Charge
Taking down chowkats or frame, (without taking off shutter from the frame) area exceeding 1.5 but n exc 4 Sqm complete all as specified and directed by Engineer-in-Charge
Taking down shutters of any description exc 1 Sqm but n.exc 2 Sqm each complete all as specified and directed by Engineer-in-Charge
S&F well seasoned 2nd class hard wood plan, solid, straight chowkat and frames, wrought framed, rebate on the solid rounded or chamfered, put together with glue pinned at joint complete all as specified and directed by Engineer-in-Charge
M&L for Mild steel work as in hold fast / Bands, straps, supports or stays for rainwater, including bolts, if required, and similar small articles conforming to Fe-290 Gde-E-165 all as specified.
M&L for Cutting holes in brick walls in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required, depth of embedded portion of holdfasts measured from the face of the jamb into the wall not exc. exc. half brick complete
S&F 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified.
S&F for PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour pvc sheet reinforced with MS square tube, suppling & fixing in opening as per specn & drg
S&F for factory made solid PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm with stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, complete all as specified.
S&F 100 mm size butt hinges medium weight cold rolled mild steel complete all as specified and directed by Engineer-in-Charge
S&F 150 mm size Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed by Engineer-in-Charge
S&F 150 mm Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed by Engineer-in-Charge
S&F Aluminium anodised sliding door bolt 300 mm long, with hasp, staple (bolt type) and fixing clip of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed by Engineer-in-Charge.
S&F in repairs CP mild steel gratings suitable for 75 / 100 mm dia for NT/ FT complete all as specified and directed.
Supply and fix in repairs white vitreous china squatting pan ‘ORISSA’ pattern of size 580 mm x 450 mm white with integral foot rests with ‘P’ or ‘S’ trap, front or back inlet including all connection and provision of lime concrete base complete all as specified and as directed..
S&F in repair white vitreous China wash down water closet pan (padestal pattern), fixed in position with fixing bolts, connection to drain pipe and to flushing pipe, etc., complete.
Supply and fixing in repairs Plastic water closet seat, white, closed pattern with flat bottom , and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
S&F in repair PVC low level flushing cistern, valveless, syphonic action type, double push botton, 10 litres capacity with inlet, ball valve float and handle with and including brackets & PVC bend pipe 32 mm dia of required length and making connection complete complete all as specified.
S&F in repair PVC connection 15 mm size with PTMT nut, length 450 mm complete all as specified and directed.
S&F in repair PVC connection 15 mm size with PTMT nut, length 600 mm complete all as specified and directed.
S&F in repair galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm in steel window clips and wooden beading in wooden joinery complete all as specified and directed.
M&L for preparation of new wood and wood based surfaces of any description, not otherwise desceribed over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Hacking out old broken glass (any thickness size, quality or description) from wooden frames or stone, concrete or bricks round, glazed with putty or fixed with bedds complete all as specified and directed by Engineer-in-Charge
S&F 3 mm thick sheet glass, ordinary quality and glzing with oil putty / timber bedds in square n. exc. 0.50 sqm in each pane complete all as specified and directed by Engineer-in-Charge
S&F 3.0 mm thick figured glass ordinary quality and glazing with oil putty n.exc 0.5 Sqm each pane
S&F 4.8 mm thick sheet glass odinary qulity and glazing with neosprene beading n.exc 0.5 Sqm in each pane.
Supply & fix in repair Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of mild steel heavy duty fixed, complete all as specified and directed.
S&F in repairs Aluminium body (extruded section) body Door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters 701 to 850 mm in width and of weight between 36 to 60 Kg and fixed, complete all as specified and directed.
S&F in repair 100 mm size mild steel mortice lock, for aluminium door, with 4 brass levers and duplicate key complete all as specified and directed by Engineer-in-Charge
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed.
S&F rolled mild steel section as in main and cross beams, hip and jack rafters; purlin where connected to common rafters and running rails and guides for for sliding doors; fixed with angle cleats or other connecting plates confirming to Fe 410-W (Gde-E-250 quality A).
Dismantling of roof sheet (any descriptions) including ridges in roof covering complete all as specified and directed.
S&F Pre- painted galvatume aluminum zinc coating GI based corrugated/plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self driven screws complete all as specified and directed.
S&F false ceiling of E-board of size 600 x 600 x 4 mm thick, white prelaminated seif embossed reinforced designer ceiling board tiles of approved texture at all height including snap grid for false ceiling of size 600 mm x 600 mm grid EXPOSED GRID SYSTEM fabricated with galvanised iron powder coated section all as shown on serial page No 185 of SSR part II (2020 print) including dismantling of existing ceiling, complete all as specified directed by the Engineer-in-Charge
M&L for Super heavy series PVC Wall panelling consisting of 5-8 mm thick Plain / wood colour PVC sheet of approved coloured & pattern, fixed on walls as per manufactures instruction including dismantling of existing panelling complete all as specified & directed.
S&F in repair ABS plastic chromium plated Health faucet fixed with spring action and lever along with Flexible hose with brass nut of length 1 m to 1.2 m fitted in the existing water connection in the toilets, Complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair white vitreous China wash hand basin (Flat back) of size 580 x 450 mm fixed on and including new brackets complete, 32 mm size brass chromium plated waste coupling, complete.
S&F in repair 32 mm size flexible pipe of PVC fixed to WHB / urinals as waste pipe (not less than 600mm long) including PVC coupling complete all as specified and directed.
S&F in repair 15 mm size pillar taps, cast copper alloy, chromium plated, fancy type, with capstan heads, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe and fixed complete all as specified and directed by Engineer-in-charge.
Taking down copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, bell, bell push, light fitting etc and making good disturbed surfaces of walls, floors,etc.as directed.
Material & Labour for conceled point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn through and including PVC conduit not less than 20 mm dia, including all accessories like bend, tees, junction boxes etc. including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable of green colour as earth wire connected to common earth dolly, including pressed steel terminal box of suitable size with laminated white top sheet cover of 3.00 mm thick complete.
All as per Item No 99 above but for one 5 pin 5 Amp socket outlet point on an independent board.
All as per Item No 99 above but for one 5 pin 5 Amp socket outlet point on the same board with other switch.
All as per item No 99 above but wiring with 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable and 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as earth wire for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch.
Material & Labour for conceled point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn through existing concealed conduit, including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable of green colour as a earth wire connected to common earth dolly, including pressed steel terminal box of suitable size with laminated white top sheet cover of 3.00 mm thick complete.
All as per Item No 103 above but for one 5 pin 5 Amp socket outlet point on an independent board.
All as per Item No 103 above but for one 5 pin 5 Amp socket outlet point on the same board with other switch.
All as per item No 103 above but wiring with 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable and 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as earth wire for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch.
S&F switch piano flush button single pole one way 5 Amp 240 volt complete all as directed.
S&F switch piano flush button single pole one way 15 Amp 240 volt complete all as directed.
S&F socket outlet flush type multipurpose 2 in1, 3 pin 5 and 16 Amp, 240 volts complete as directed.
S&F socket outlet flush type multipurpose 2 in 1, 5 pin 6 Amp, 240 volts complete as directed.
S&F fan regulator electronic, step up socket type, 230 volt,125 W and conection complete all as directed.
S&F ceiling rose polycarbonate body surface type three terminal complete as directed.
Supply & fix in repair LED 10 watt bulk head light fitting made from aluminium pressure die cast housing, with heat resistance protection cover, integrated type, 6500 K, 120 lumens / watt system efficiency, including inbuilt electronic driver complete all as specified and as directed.
Supply and fix in repair wall / surface mounting luminaires integrated LED Batten (2 feet) 10 / 12 W, 6500 K, 230V, system efficiency not les than 100 lumens / watt, with extruded aluminium housing with frosted PMMA / PC diffuser & integrated electronic driver fixed in position and connecting with ceiling rose complete all as per specified and directed by Engr-in-charge.
Supply and fix in repair wall / surface mounting luminaires integrated LED Batten (4 feet) 20 W, 6500 K, 230V, system efficiency not les than 100 lumens / watt, with extruded aluminium housing with frosted PMMA / PC diffuser & integrated electronic driver fixed in position and connecting with ceiling rose complete all as per specified and directed by Engr-in-charge.
S&F in repair LED Building security light 25 Watt with high power LED source, system efficency not less than 110 lumen / watt), aluminium die casted housing, built in electronic driver, IP65 and IK 07 with 4 KV inbuilt surge protection including electrical connection with PVC three core copper conductor cable of size 1.5 sqmm, & all necessary fixing accessories, all as specified and directed by Engr-in-charge.
S&F in replacement street light bracket fabricated with mild steel galvanised pipe light grade, 32 mm bore, 1.20 mtr long bend in required shape, fixed on wall with and including mild steel clamp fabricated with flat iron of size 40 x 3 mm and nut of sutable size, duly painted with two coats of synthetic enemal paint over one coat primer complete all as specified and directed.
Supply and fix retro fit LED lamp 12 watt, complete all as specified and as directed.
S&F in repairs integrated 25 watt LED type Post top lantern with high power LED as light source, with built in electronic driver, energy saving, environmental friendly, long life asethetically designed with symmetrical light distribution, spun auminium landscape lumainaire, fixed in position and connecting complete all as directed.
Material & Labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 6.00 Sqmm, PVC insulated, unsheathed, fire retardant low smoke, drawn through and including heavy duty rigid PVC conduit not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 6.00 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire in green colour, fixed on wall / ceiling, including taking down old sub main wiring complete. Note: (i) 2 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment.
Material & Labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 4.00 Sqmm, PVC insulated, unsheathed, fire retardant low smoke, drawn through existing concealed conduit including one run single core multistranded copper conductor cable, of size 4.00 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire in green colour, fixed on wall / ceiling, including taking down old sub main wiring complete. Note: (i) 2 Runs of main cable and one run earth wire will be measured as one Unit for payment.
S&F in repair flat or circular PVC insulated, with inner sheathing of PVC tape and overall PVC sheathed aluminium conductor cable of size 2 core 06 Sqmm 1100 volt grade, fixed for service connection, complete all as specified and as directed.
S&F in repair flat or circular PVC insulated, with inner sheathing of PVC tape and overall PVC sheathed aluminium conductor cable of size 2 core 10 Sqmm 1100 volt grade, fixed for service connection, complete all as specified and as directed.
S&F in repair distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 4 way with 200 Amps rated copper busbar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, fixed flush to wall complete all as specified and directed.
S&F in repair distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 8 way with 200 Amps rated copper busbar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, fixed flush to wall complete all as specified and directed.
S&F in repair distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 12 way with 200 Amps rated copper busbar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, fixed flush to wall complete all as specified and directed.
S&F in repair distribution board (DB), double door type made out of sheet metal enclosure (CRCA sheet) dust and vermin proof DB, TPN 4 way with 200 Amps rated copper busbar, 415 Volts earth bar IP 43 protection, fixed flush to wall complete all as specified and directed.
S&F MCB, single pole 6 to 32 Amp, 240 volts, 10 KA breaking capacity, 'C' curve complete all as specified and directed.
S&F MCB, single pole & neutral 63 Amp, 240 volts, 10 KA breaking capacity, 'C' curve complete all as specified and directed.
S&F MCB, triple pole & neutral 63-100 Amp, 415 volts, 10 KA breaking capacity, 'C' curve complete all as specified and directed.
S&F in replacement sheet metal enclosures with socket plug top and MCBs with a two pin and earth plug and socket complete with including one single pole MCB 20 Amps C curve complete all as per specified and directed
S&F in repairs VTPN distribution board, 4 way double door suitable for incommer 4 pole MCCB, 415 V & SP / TP MCB as outgoing, 200 Amps rated Busbar, inter connection link, cable ties, earth bar etc incl necessary civil works and electrical connections with suitable lugs / spreader links complete all as specified and directed by Engr-in-charge. Note: MCCB & MCB to be measured and paid seprately.
S&F MCCB 100 Amps 415 volts, 4 pole 16 KA breaking capacity fixed in DB and connecting complete as directed.
S&F in repair switch piano flush button single pole one way 5 Amp 240 volt complete all as directed.
S&F in repair switch piano flush button single pole one way 15 Amp 240 volt complete all as directed.
S&F in repair socket outlet flush type multipurpose 2 in1, 3 pin 5 and 16 Amp, 240 volts complete as directed.
S&F in repair socket outlet flush type multipurpose 2 in 1, 5 pin 6 Amp, 240 volts complete as directed.
S&F in repair switch socket combination flush type multipurpose 2 in 1, 3 pin 5 and 15 Amp, 230 volts complete as directed.
S&F in repair angle batten type holder insulated body with back plate suitable for batten fittings as directed.
S&F in repair PVC gang box fitted with and including piano type switch 15 A and socket 15 A, 230 Volts complete with pvc gitties and screws all as specified and as directed.
M&L of Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to galvanized earth lead wire 4.0 mm dia by means of nut, bolts, check nut & washer of galvanized iron or of steel, earth lead protected by 15 mm dia GI pipe light grade, watering pipe 20 mm dia GI light grade, GI wire mesh, GI funnel, alternate layer of char coal and salt, PCC chamber, recessed for and including RCC cover including all necessary excavation & earth work, earth wire 7.5 mtr connected to main switch board, testing the earthing after completion all as specified and shown in electric plate No 3 of MES SSR Part-I 2009 complete all as specified and directed .
Taking down old detiorated, rusted out lived and unsv ceiling fan, supply & fix new ceiling fan 1200 mm sweep, BLDC copper wound motor, AC single phase, 230 volts, white colour complete with fan blade, down rod, canopy and provn of connection with three core flexible copper wire cable of size 1.50 sqmm from ceiling rose to fan, writing of MES Nos as approved size of letter complete all as specified and directed.
Taking down detiorated, rusted out lived and unsv exhaust fan, supply & fix new exhaust fan metal body 300 mm sweep, 900 RPM, copper bound motar, AC 230 volts, single phase with louvers including making connection with three core PVC insulated 1100 volts grade multi stranded copper wire of appropriate size including testing, writing of MES Nos as approved size of letter complete all as specified and directed.
Taking down detiorated, rusted out lived and unsv exhaust fan, supply & fix new exhaust fan metal body 380 mm sweep, 900 RPM, copper bound motar, AC 230 volts, single phase with louvers including making connection with three core PVC insulated 1100 volts grade multi stranded copper wire of appropriate size including testing, writing of MES Nos as approved size of letter complete all as specified and directed.
Taking down detiorated, rusted out lived and unsv exhaust fan, supply & fix new exhaust fan metal body 450 mm sweep, 900 RPM, copper bound motar, AC 230 volts, single phase with louvers including making connection with three core PVC insulated 1100 volts grade multi stranded copper wire of appropriate size including testing, writing of MES Nos as approved size of letter complete all as specified and directed.
Taking down detiorated, out lived and unsv fresh air ventilator fan, supply & fix new 250 mm sweep fresh air ventilator fan, PVC body & PVC blade, 230 Volt, 50Hz, single phase AC supply, with PVC louvers fixed in position and connecting with ceiling rose, writing of MES Nos as approved size of letter complete all as specified and directed.
Taking down detiorated, out lived and unsv fresh air ventilator fan, supply & fix new 300 mm sweep fresh air ventilator fan, PVC body & PVC blade, 230 Volt, 50Hz, single phase AC supply, with PVC louvers fixed in position and connecting with ceiling rose, writing of MES Nos as approved size of letter complete all as specified and directed.
M/S ANIL ARORA (BID ID -3465233)
M/S SHIVA CONSTRUCTION (BID ID -3469801)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
Tender44.pdf
Tender Documents • 1.36 MB
BOQ_824191.xls
BOQ • 0.50 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .