| 1 | L1₹8.7 LAccepted-AOC OLD NO 10 B NEW NO 39 3RD MAIN ROAD RAJALAKSHMI NAGAR VELACHERY CHENNAI 600 042 | CHENNAI | CHENNAI | TAMIL NADU | 600042 | ₹8.7 L | L1 | Accepted-AOC lowest rate quoted by the tenderer hence the tender is accepted |
| 2 | L2₹8.8 LRejected-AOC | ₹8.8 L | L2 | Rejected-AOC higher rate quoted compared to lowest tenderer quoted rate |
Tender Value
Refer Docs
EMD Value
₹8,700
Closing Date
13 Feb 2026, 3:00 pmClosed
Executive Engineer
Executive Engineer Buildings C and M South Presidency Division Chepauk Chennai 5
Special Repairs to Gents staff toilet and other repair works to training institute and walls to Second and third floors of Triplicane Sub Registrar Office in Bharathi Salai at Royapettah Chennai 14
2026_PWD_655163_1
TNPWD/48-02/21M/2025-2026
Open Tender
Civil Works
60 days
Royapettah chennai
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹8,700
12 May 2026
11 Feb 2026
13 Feb 2026
11 Feb 2026
13 Feb 2026
11 Feb 2026
Dismantling , removing and carefully stacking Doors & windows including removal of frames,hinges and fastenings etc., complete complying with standard specification and as directed by the departmental officers at site of work.
Dismantling the damaged floor finish and dadooing walls in cement mortar with mosaic tiles / Glazed tiles/cuddapah slab and clearing away with carefully stacking the material useful for reuse for any thickness etc., complete complying with standard specification and as directed by the Departmental officers.
Clearing the surface thoroughly with water and remove all the impurities and loose plaster, flacks, fungus growth etc by suitable mechanical means like scrapping or wire brushing and subsequantly wash with adequate water to get an abosulutely cleaned surface to take on further treatment. All the grooves will be refilled with multi proof co polymer with filler loose plastes and cured cement mass will be removed tto multi proof acrylic co ploymer with cement and fine and mix in the ratio 1:2:4 (one of cement two of river sand four of aggregate ) to fill of proof acrylic co polymer mix with cement ratio 1:2 coats over night setting the cure with water apply weather tuff sealter coat polymer membrance two coats mixed with water in the ratio 8:2 etc complete complying with standard specification and as directed by the departmental officers at site of work.
Brick Jelly Lime Concrete 1:2:5 using 20mm brick jelly in Lime Mortar 1:2 - 10 cu.m. etc., Complete complying with standard specification and as directed by the departmental officers.
Paving the floor with best quality vitrified Tiles 600x600x8mm of size and variety conforming IS 15622 with water absorbtion less than 0.08% of approved colour and shade laid over cement mortar bed of 20mm thick in cement mortar 1:3 (one cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer in all floors and the top pointed with Water Resistant Tile Epoxy Grout etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Dadooing walls with best approved quality, Designed colour ceramic tiles of size 600mmx300mmx10mm set in Cement Mortar 1:2 (One Cement and Two sand) 10mm thick and pointing the joints with water resistent tile epoxy grount at the rate of 0.27 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers.
Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with "P" or "S" trap conforming to BIS with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two sand and Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works).
Supplying and fixing Mild Steel grills for windows, ventilators etc.,complete complying with standard specifications and as directed by the departmental officers
Supplying and fixing in position of 19mm thick Antitermite plywood including cock of painting with complete complying with standard specification and as directed by the departmental officers.
Supplying and fixing in position Sun control film of best quality etc., complete complying with standard specification and as directed by the departmental officers.
Renewing the damaged broken unserviceable two way tap of Jaquar make including labour charges for fixing in position etc complete complying with standard specification and as directed by the departmental officers at site of work.
Renewing and fixing Angle Cock with new one of Jaquar make including labour for fixing in position etc complete complying with standard specification and as directed by the departmental officers at site of work.
Supplying and fixing unitex Red carpet of approved quality of brand and fixing the same in position with necessary synthetic resin in to alignment as director by the departmental officers.
Renewing and refixing in position of best Indian make white glazed earthernware big size Magnum urinal of best quality and approved make of size 380x400x590mm with GI pipe, 32mm dia bell mouth PVC connection and waste pipe, 15mm dia GI pipe of required length, 15mm dia GM wheel valve, 15mm dia brass nipple 2 Nos., and fixing the urinals in position with necessary TW plugs, clamps, screws, etc., including dismantling masnory and re-doing the same to the original condition, etc., including painting the pipe with two coats of best quality approved synthetic enamel paint over one coat of red oxide primer and checked without any leakage etc. complete complying with standard specifications and as directed by the departmental officers.
Supplying and fixing granite for urinal partition including nosing in all edges, labour charges for fixing etc., Complete and as dirceted by the departmental officers
Supplying and fixing position CI Nahani Trap / Floor Trap of size 100 x 75mm with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of sand and five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works)
Renewing and refixing the WPC door shutters including cost of furniture fitting such as 3 nos 4"brass butt hinges,2nos 6"brass tower bolts,2nos 4"brass handle, 1 no brass drop, single key shutter, mortice lock without night latch, etc., complete complying with standard specification.
Renewing and laying and jointing UPVC Pipe(Un-Plasticized Polyvinyl Chloride) UPVC used for residential and home applications, water pressure in residential areas do not normally exceed the maximum tolerance.(schedule-40) but excluding cost of such specials and fixing in position dismantling masonry and make the same to original condition etc complete complying with standard specification and as directed by the departmental officers at site of work.
UPVC pipe of 20mm dia
Renewing and refixing UPVC special of approved quality and make including labour for fixing in position etc complete complying with standard specification and as directed by the departmental officers at site of work.
20mm dia UPVC Elbow
20mm dia UPVC Tee
20mm dia UPVC Coupler
20mmx15mm reducer elbow
Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level
110mm dia PVC soil pipe
75mm dia PVC soil pipe
Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works).
110mm dia UPVC Elbow
110mm dia UPVC Door elbow
110mm dia UPVC Door Tee
75mm dia UPVC Elbow
75mm dia UPVC Tee
Painting the walls two coats of Interior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification and as directed by the departmental officers.
Painting the old wood work two coats in all floors with best Synthetic enamel paint of approved quality, colour in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Painting Old iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with Two coats of best approved first quality and colour of synthetic enamel paint in all floors etc., complete complying with standard specification and as directed by the departmental officers.(The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Renewing the damaged vertical blinds with new horizontal zebra fabric roller blinds of superior quality double ply plinds with 100% polister composition weight of 340 gsm / square metre and 0.40mm thick and finished width of 250cm with 100% light transmission etc.,omplete complying with standard specification and as directed by the departmental officers at site of work.
Collecting the scattered debries using tipper machinery from work spot and loading into the tipper lorry and conveying away the same to outside by lorry to a lead of 3km entirely with in city limit including loading and unloading charges and dumping in low places and levelling neatly etc., complete complying with standard specification and as directed by the departmental officers. (200 cft volume capacity)
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.11 MB
CONDITION02.pdf
Tender Documents • 0.32 MB
BOQ_785595.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid