Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹7.4 LAccepted-AOC | 1 | Accepted-AOC accepted | |
| 2 | 2₹7.4 L+₹1,262 (0.17%)Rejected-AOC | 2 | Rejected-AOC rejected | |
| 3 | 3₹8.0 L+₹62,455 (8.48%)Rejected-AOC | 3 | Rejected-AOC rejected | |
| 4 | 4₹9.1 L+₹1.7 L (22.9%)Rejected-AOC | 4 | Rejected-AOC rejected | |
| 5 | 5₹9.9 L+₹2.5 L (34.1%)Rejected-AOC | 5 | Rejected-AOC rejected |
Tender Value
₹8.2 L
EMD Value
₹16,400
Closing Date
4 Dec 2019, 5:00 pmClosed
EE PHED No.1 Faridabad
EE PHED No.1 Faridabad
Providing and Installation 1 No. Tubewell against failed T.W. in Govt. College for Woman Sector-16-A, Faridabad
2019_HRY_108651_1
SE GGM No. 6773 dated 11.11.2019
Open Tender
Civil Works
Works
90 days
Faridabad
2 documents required · 2 mandatory
₹1,000
Yes
Engineer in Chief
₹16,400
Yes
10 Feb 2020
19 Nov 2019
5 Dec 2019
19 Nov 2019
4 Dec 2019
19 Nov 2019
Amount
Drilling of 609.60 mm dia bore by hydraulic rotary drillring reverse circulation method)/. according to ISI specification No 2800-1991 (Fart-l) as amended up to date and modified to extent of the specification attached with this schedule of items of work in all kinds of soil and boulders up to 125mm dia except rocky strata including the cost of all consumable stores, fuel oil, soil, stabilizing material and transportation of rig and other accessories to the site of proposed bore and back, complete to the satisfaction of the Engineer-in-charge.
Supply & Lowering 219.10mm outer dra ERW steel pipes as per lS 4270-1992 as amended up to date duly lSl marked for housing pipe in 4 to 7 meters random length with 88.90 mtr. of threaded ends (8 threads to an inch or 25 40mm) manufactured out of 6 40 mm thick M.S plates with required number of M S socket 177.80}mm with inside thread to match the pipe threads and made out of M S plate in to borehole in vertical position including cost of all scaffolding, derricks, jim, poles, tools and plants, ropes guys M.S clamp embedded in foundation etc. complete in all respects to the satisfaction of the Enginner-in-charge of the work including cost of all threading of pipe welding where required and all sockets . The pipe shall be painted with anti corrosive paint and covered tightly with polythene.
Prov. & lowering 219.10 mm o/d LCG Screen confirming to ISI Specification of outer dia 221 mm equivalent thickness 8.00 mm , tensile load 14000 kg, minimum and ring thickness 8 mm slot opening 0.75 mm open area 25%
Prov. & fixing in position suitable bail plug hook of 219.10 mm as per IS 226/ 1975 as amended up to date including the cost of MS screwed sockets etc complete in all respects to the entire satisfaction of Engineer- in charge of the work.
Supplying and packing graded gravel of size as per ISI 4097/ 1988 as amended up to date and specification attached with this schedule of items of work. The gravel should be free from dust. Dirt or Vegetable matters packing to be done from the housing pipe to the boom of liner all around in the bore and will be placed after line and housing pipes have been lowered and suitable clamped . Thickness and size of the gravel packing will be designed and directed by the Engineer-in-charge strictly as per relevant ISI.
Supplying and fixing well threaded MS cap for 219.10 mm outer dia MS pipe as per ISI 226/1975 as amended up to date to the satisfaction of the Engineer-in charge.
Supply as per IS 226/1975 as amended up to date deodar wooden box made of 20 mm thick wood size 60 cm x 30 cm x 75 cm with lid and locking arrangement etc. for preserving the strata samples received from the bore as and when desired by the Engineer- in-charge
supplying and fixing 219.10 mm M S clamp as per ISI 226/1976 as amended up to date for supporting the sousing pipe supported on two girders not less than ISMB 100 mm x 150 mm weight not less than 17.00 kg/ m cross section area not less than 21.67 sq cm , flange thickness 7.00 mm web thickness 5.40 mm , 2.00 mm long embedded in suitable foundation as approved by the Engineer-in- charge
Development of T/Well according to clause 9.3 of IS 2800- 1991 (Part-I) as amended up to date and specifications attached and as directed by the Engineer- in – charge of the work including the cost of all consumable stores , fuel, oil compressors, pumps and machinery etc. as required for this work. a) when development by compressor of 600 CFM 250 PSI and suitable rating of 25 hours
Resistivity Survey
Supplying, erection testing and commissioning of Submersible Pumping Set as per BIS Specification No.8034-1989 (as amended upto date for pumps) and IS. 9283-1979 (as amended upto date for motor) the pump Motor set should be capable of pumping clear fresh cold water having Characteristics as specified in Clause-4 of IS. 8034/1989 and Clause 4.1 of IS 9283/1979. Each pump Motor Set shall be supplied with joint free 50 M. double length PVC. Insulated and PVC. Sheathed Fexible 3 core flat type submersible Cable of finolex make and junction box for jointing of submersible Cable and Submersible pumping set. i) 300LPM/ 80 Mtrs .Head (10.00 BHP)
Supplying erection, testing of electric control Panel Board for T/wells in Pump Chamber consisting of MS Sheet of thickness 14 gauge duly painted box type floor mounted made of Angle frame containing 1 Nos. fully automatic air brake Starter suitable for 10.00 HP Motor, Main switch of suitable range with HRC fuse, 1 No. Volt meter (0 to 500 Volts), 1 No. Amp. Meter of 0 to 32 Amp., 3 sets of Indicating lamp, Capacitor of suitable capacity & 1 No. Single Phase Preventors with the Timer Switch including wiring in Panel Board & suitable Electric Energy Meter wiring from to Electric Control Panel Board complete in all respect as per Specification given in Schedule No.II.
Supplying and fixing following C.I. D/F pipe, CI specials, sluice valves with wheel, non return valves with G.M. Flap including cost of jointing materials, excavation, laying refilling including making adequate supports of asonry/ concrete/ steel for delivery pipe from Submersible Pump Set upto 1.5 meter outside the outer wall of Pump Chamber as per plan shown as per specification given in Schedule No. II. A) Detail of pipe and specials CI D/F bends, reducers, tapers, tees, tail piece, blank flange etc. upto 100 mm i/d
C.I. D/F pipes a) 100 mm i/d
Earthing with G.I. earth pipe 4.5 meter long 40mm dia with masonry enclosure & 4mm dia G.I. wire in 15mm dia G.I. pipe from earth electrode as per I.E./1996 rules & as required by Chief Electrical Inspector of HVPN as per specification in schedule No.II complete in all respect.
P & F of presure Gauges with siphon cock as per IS : 3624 , & havinig 150 mm dia, Dial Gauge, in delivery pipe inside pump chamber
Providing & fixing of DI Special required for laying of pipe line, Bend, Tee, Reducer etc. complete in all respects confirming to IS Specification 9523 as amended upto date.
Bidder Name
Amount
Kunal Enterprises
Harender Kumar
KASAM KHAN CONTRACTOR
HAFEEJ KHAN
Chitkara Constructions
Kunal Enterprises
Chitkara Constructions
KASAM KHAN CONTRACTOR
HAFEEJ KHAN
Harender Kumar
Chitkara Constructions
KASAM KHAN CONTRACTOR
HAFEEJ KHAN
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .