Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.4 LAccepted-AOC SAIDAKADAL SRINAGAR KASHMIR | SRINAGAR | JAMMU AND KASHMIR | 190001 | ₹28.4 L Quoted ₹29.5 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹30.8 L+₹1.3 L (4.48%)Rejected-Finance 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | ₹30.8 L+₹1.3 L (4.48%) | L2 | Rejected-Finance Other than lowest bidder |
| 3 | L3₹36.6 L+₹7.1 L (24.1%)Rejected-Finance | ₹36.6 L+₹7.1 L (24.1%) | L3 | Rejected-Finance Other than lowest bidder |
Tender Value
₹47.8 L
EMD Value
₹95,600
Closing Date
4 May 2024, 6:00 pmClosed
GE 860 EWS Karu
GE 860 EWS Karu Pin- 194201
SERVICING MAINTENANCE REPLACEMENT OF FUEL FILTER V BELT OIL FILTER AND ALLIED WORK SERVICES OF DG SETS AT KARU ZONE I AND CAPTIVE REPAIRS TO VARIOUS DG SETS AND REPLACEMENT OF MINOR PARTS PANELS AND MISC WORKS AT TANGTSE AND DURBUK AREA UNDER GE
2024_MES_649277_1
8143/2024-25/E8
Open Tender
Civil Works
Item Rate
270 days
GE 860 EWS Karu
As per tender documents
9 documents required · 9 mandatory
₹500
GE 860 EWS Karu
₹95,600
Yes
15 Jun 2024
4 Apr 2024
6 May 2024
4 Apr 2024
4 May 2024
19 Apr 2024
Amount
Material and labour for replacement of fuel filter for 1000/1010 KVA DG Set , Make:-Greaves and change of fuel filter after every 250 Hrs complete all as per site requirement
Material and labour for replacement of fuel filter for 160 KVA DG Set , Make:-Cummins and change of fuel filter after every 250 Hrs complete all as per site requirement
Material and labour for replacement of fuel filter for , 160, 125, 82.5, 62.5, 32.5 A DG Set , Make:-Kirloskar and change of fuel filter after every 250 Hrs complete all as per site requirement
Material and labour for replacement of lub oil filter/super by pass filter for 1000/1010 KVA DG Set , Make:- Cummins and change of oil filter after every 250 Hrs complete all as per site requirement including lubricating and greasing to all parts.
Material and labour for replacement of lub oil filter for 200, 160, 125, 82.5, and change of oil filter after every 250 Hrs complete all as per site requirement including lubricating and greasing to all parts.
Material and labour for replacementlub oil filter for 63/35 KVA DG Set , Make:-Kiloskar and change of fuel filter after every 250 Hrs complete all as per site requirement
Material and labour for replacement of air cleaner filter for 1000/1010 KVA DG Make : Cummins set change of air cleaner filter Make: Kirloskar/Greaves after every 500 Hrs complete all as per site requirement.
Material and labour for replacement of air cleaner filter for 160/125/82.5 KVA DG set change of fuel filter Make:Cummins/Kirloskar after every 500 Hrs complete all as per site requirement.
Material and labour for replacementl of Air cleaner filter for 63/35 KVA DG Set , Make:-Kiloskar and change of fuel filter after every 500 Hrs complete all as per site requirement
Calbiration of injector assembly including replacement of injector cups, barrel,nozzles, O-rings screen filter and setting the oil pressure with testing suitable for 160/125/82.5 KVA DG Set, Make:- Kirloskar and Model HA69TC DG set complete all as directed by Engr-in-Charge.
Calbiration of injector assembly including replacement of injector cups, barrel,nozzles, O-rings screen filter and setting the oil pressure with testing suitable for 1010 , Make:-Cummins DG set complete all as directed by Engr-in-Charge.
S&F in replacement of fan belt suitable for 160/100/125/82.5 KVA DG set complete all as directed by Engr-in-Charge. Make-Fenner/KCL
S&F in replacement of fan belt suitable for 1010 KVA DG set complete all as directed by Engr-in-Charge. Make-Fenner/KCL
Supply & fix in replacement of U/S lead acid battery 12 Volt 180AH with initially charged Make-Exide
Repair/servicing self starter by supply and fixing including taking out the following parts ,(a). Field Coil (b).Armature Winding (c ).Bush (d). Solenoid switch (Gear) for 1010 KVA DG Sets Make : Cummins
Repair/servicing self starter by supply and fixing including taking out the following parts ,(a). Field Coil (b).Armature Winding (c ).Bush (d). Solenoid switch (Gear) for 63/82.5/125 KVA DG Sets Make : Kirloskar
M & L for replacement of automatic voltage regulator for DG Set of following capacity :-
(a) DG Set 1010 KVA Make : Cummins
(b) DG Set 160/125/82.5 KVA Make : Kirloskar/Cummins
(c) DG Set of capacity 62.5/32.5 KVA Make : Mahindra
Dismantling the radiator from the engine of 1010 KVA DG set transporting the radiator from site to workshop. Dismantling the radiator in and including descaling ,gas welding the leaking tube whichever required for proper functioning of radiator. After repair retransportation from workshop to site and fixing the same with engine as existing and reseting to complete satisfaction of Engr-in-Charge.
All as per item Ser No. 21.00 here-in-before but of capacity 160/125/82.5 KVA
Dismantling disconnecting Turbo charger from 1010 Kva DG Sets supply and fixing the same complete as specified and as directed by Engr-in-charge.Make :Holmet or equivalent
Supply & fixing in replacement Diesel pipe set flexible for 1010/160/125/82.5 KVA DG Set complete all as specified and as directed by Engr-in-Charge. Make :- Cummins/Kirloskar
Supply & fixing hose rubber C/W inlet suitable for 160/125/82.5 Kva DG Set complete all as specified and as directed by Engr-in-Charge. Make :-Kirloskar
Supply & fixing water pump assembly suitable for 1010 Kva DG Set complete all as specified and as directed by Engr-in-Charge. Make :- Cummins or Equivalent
Supply & fixing water pump assembly suitable for 160/125/82.5 Kva DG Set complete all as specified and as directed by Engr-in-Charge. Make :- Kirloskar/Cummins or equivalent
S & F in replacement Alternator (Battery Charger) suitable for DG Set of capacity 1010 KVA of existing make and Modal complete all as specified and directed
M & L for cleaning of fuel tank of DG sets of capacity upto 1010 KVA by draining out the fuel and storing in a container for re-filling complete all as specified and directed by Engr-in-charge
Supply and fixing for replacement of copper battery lead 3 Mtrs long PVC insulated multi stranded with brass clamp incl necessary bolts & nuts and fixing lugs etc complete all as specified and as directed by Engr-in-Charge.
Draining all the U/S DAFC 50% from the DG Sets Supply and filling theDAFC 50% all as specified and as directed by Engr-in-charge.Make Servo, HP or any approved Make.
Supply and fix electronic nozzle suitable for 82.5 KVA DG set of existing make and model including taking out old UNSV nozzles Make:-Greaves/Kirloskar/Cummins DG set complete all as directed by Engr-in-Charge.
All as per item Ser no. 32.00 here in before but suitable for DG set of capacity 30 to 63 KVA
Supply and fix nozzle suitable for 1010 KVA DG set of existing make and model including taking out old UNSV nozzles Make:-Greaves/Kirloskar/Cummins DG set complete all as directed by Engr-in-Charge.
All as per item Ser no. 34.00 here in before but suitable for DG set of capacity 63 to 160 KVA
S& F in replacement oil feed pump with assembly of existing make and model suitable for DG set of capacity 63 KVA to 1010 KVA
S&F in replacement Self Starter 24 volt suitable for DG Set of capacity 160/125 KVA of existing maka and model complete all as specified and directed Make : Lukas or equivalent
S&F in replacement Self Starter 12 volt suitable for DG Set of capacity 63/82.5 KVA of existing maka and model complete all as specified and directed Make : Lukas or equivalent
Supply and fix in repair off load change over switch 415 volt 50 Hz confirm to IS-13947-3 with enclosure and side handle of cap 400 Amp four pole including takind down old switch Make Havells /C&S/Indoasian
Supply and fix in repair off load change over switch 415 volt 50 Hz conform to IS-13947-3 with enclosure and side handle of cap 200 Amp four pole including takind down old switch Make Havells /C&S/Indoasian
M & L Calibration of electronic panel of 82.5 KVA Kirloskar DG set with Laptop and fixing all fault including replacement of US relays/wiring as per requirement by cummins engineer all as directed at site
M & L Calibration of electronic panel of 30/63 KVA Kirloskar DG set with Laptop and fixing all fault including replacement of US relays/wiring as per requirement by cummins engineer all as directed at site
M & L for repair and cleaning of exhaust silencer of DG Set of capacity 1010 KVA including cutting and welding as per requirement complete all as specified and directed by Engr-in-Charge
M & L for repair and cleaning of exhaust silencer of DG Set of capacity 160/1225/82.5 KVA including cutting and welding as per requirement complete all as specified and directed by Engr-in-Charge
Supply & fixing in replacement of Oil sensor suitable for DG set of capacity of DG Sets 63 to 1010 complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement of Water/Coolent sensor suitable for DG Sets 63 to 1010 KVA complete all as specified and directed by Engr-in-Charge.
M & L for Calibration of FIP of DG set of capacity 1010 KVA including supply & fixing in replacement plunger, DV, governor wet O-Ring, Pin roll, barrel, Pin ball bearing spring, washer and testing for following capacity of DG Set complete all as specified and directed by engr in Charge.
All as per item Ser No. 47.00 here in before but DG set of capcity 63 to 160 KVA
Supply and Replacement of Thermostate valve suitable for DG Sets of capacity 63 to 1010 KVA complete all as specified and directed by Engr-in-Charge.
M&L for Strip opening of alternator 160/125 KVA DG set , removing rotor from the stator and rewinding to CT coils complete with super enameled copper winding wire of appropriate size including insulating material and replacing the following parts of the alternator.Note: Re-assembling all the component of the alternator and mounting the same on the existing foundation including welding of alternator foundation plate by electric arc welding ,aligning the alternator with engine and testing on full load as specified in particular specification and as directed by Engr-in-Charge.
All as per item Ser No. 50.00 here in before but DG set of capacity 82.5/125 KVA
S& F in replacement Control Card (PCB) of existing make and model suitable for DG set of capacity 125/82.5 KVA Make : Kirloskar
S & F in replacement Alternator (Battery Charger) suitable for DG Set of capacity 63/82.5/125 KVA of existing make and Modal complete all as specified and directed
Draining all the U/S E Oil from the DG Sets Supply and filling the 20 W 40 E oil all as specified and as directed by Engr-in-charge.Make Servo, HP or any approved Make.
S&F in replacement hoses of DG set of capacity 1010 KVA Make : kirloskar/CG of existing size complete all as specified and directed by Engr-in-charge
S&F in replacement hoses of DG set of capacity 63/82.5/125/160 KVA Make : kirloskar/CG of existing size complete all as specified and directed by Engr-in-charge
M & L Cleaning of radiator for following capacity DG sets of capacity 63 to 160 KVA by using anti scalent chemical and radiator cleaning solution (Ready to Wash) by pressure pump and brush and re-assembling after painting of the same complete all as directed.
Supply & fixing in replacement of DC wiring of Control panel and DG set of capacity 63 to 125 KVA , complete all as specified and directed by Engr-in-Charge.
S& F In replacement FIP for DG set of Capacity 125/82.5 KVA Make : Kirloskar /cummins of existing make and model as directed by Engr-in-charge
Supply and fix in repair off load change over switch 415 volt 50 Hz conform to IS-13947-3 with enclosure and side handle of cap 63 Amp four pole including taking down old switch Make Havells /C&S/Indoasian
Supply and fix in repair On load change over switch 415 volt 50 Hz confirm to IS-13947-3 with enclosure and side handle of cap 200 Amp four pole including taking down old switch Make Havells /C&S/Indoasian
Supply and fix in repair On load change over switch 415 volt 50 Hz conform to IS-13947-3 with enclosure and side handle of cap 400 Amp four pole including taking down old switch Make Havells /C&S/Indoasian
Supply and fix in repair On load change over switch 415 volt 50 Hz conform to IS-13947-3 with enclosure and side handle of cap 630 Amp four pole including taking down old switch Make Havells /C&S/Indoasian
Supply and fix in repair On load change over switch 415 volt 50 Hz conform to IS-13947-3 with enclosure and side handle of cap 100 Amp four pole including taking down old switch Make Havells /C&S/Indoasian
Dismantlig/disconnecting the defected Fuel valve of 1010 KVA DG Set supply and fixing the same complete all as specified and directed by Engr-in-charge Make ;-Cummins.
Dismantlig/disconnecting/opppening the defected heads of the DG Set 1010 KVA shifting the heads of the DG Sets to Autherised work shop grinding polishing complete with connected items like head valve guide valve, Head Gasket etc reqd while repairing the head of the DG SET refixing the same complete all as directed by Engr-in-charge.
All as per item Ser No. 66.00 above here-in-before but DG set of capacity 100/125 KVA DG Set
Calibration of PT pumps, replacement of PT pump kit, gasket set, washers, nuts,plungers,delivery valves, oil pump , O ring and set the oil pressure with testing suitable for 160 KVA DG set complete all as directed by Engr-in-Charge. Make-Cummins .
Calibration of PT pumps, replacement of PT pump kit, gasket set, washers, nuts,plungers,delivery valves, oil pump , O ring and set the oil pressure with testing suitable for 200/250/160 KVA DG set complete all as directed by Engr-in-Charge. Make-Kirloskar..
Supply & Fixing actuator fuel controller 1010 KVA Make- Cummins
Dismantling/ disconnecting Muffler from 1010 Kva DG set supply and fixing the same as specified and as directed by Engr-in-charge.Make cummins
Dismantling/ disconnecting Muffler from 200 Kva DG at power house set supply and fixing the same as specified and as directed by Engr-in-charge.Make Kirloskar
M & L for dismantling and opening Head of DG Set of capacity 125/160/82.5 KVA and replacement of all unserviceable parts and Head Gasket including necessary lathe work as per requirement complete all as specified and directed
Supply and fix in replacement Speed governor suitable for DG Set of capacity 125/160/200 KVA of existing make and model all as specified and directed
M&L for Strip opening of alternator 1010 KVA DG set , removing rotor from the stator and rewinding to CT coils complete with super enameled copper winding wire of appropriate size including insulating material and replacing the following parts of the alternator.Note: Re-assembling all the component of the alternator and mounting the same on the existing foundation including welding of alternator foundation plate by electric arc welding ,aligning the alternator with engine and testing on full load as specified in particular specification and as directed by Engr-in-Charge.
NOTE for Srl Item No 1.00 to 75.00: The items pertain to works at Karu Zone I area. Rate quoted by the contractor shall deem to consider this aspect. NOTE for Srl Item No 77.00 to 123.00: The items pertain to works at Tangste and Durbuk area. Rate quotedby the contractor shall deem to consider this aspect.
M&L for Checking, Inspection, maintanance and servicing complete including replacement of unserviceable spare parts of the DG set (comprising of Engine/ Alternator/ Control panel) of the following capacity for smoth functioning complete all as per manufacturers instructions and all as directed by Engr- in- Charge :- A. (a) Checking of lubricating oil condition (b) Checking engine for oil, water leakage and rectifying the same (c) Checking of all the nut bolts of engine and alternator (d) Checking of all belts and adjust the tension properly (e) Cleaning of air filters (f) Checking and readjusting the valve clearance (g) Change of Oil/Fuel filters and engine oil if necessary (h) Checking of starter motor battery and charger (i) Checking of cooling system and fuel system (j) checking of all power cables and AVR connections and mounting bolt tightnees of alternator (k) checking the function of AVR genaral checks (l) Checking of control panel meters and gadgets functiong (m) Checking of all control and safety wirings B. (a) Checking of flexible coupling of engine and alternator (b) Cleaning of crank case ventilation pipe (c) Checking of injectors and fuel pump (d) Checking of alternator and carbon brushes of following capacity DG sets NOTE: (1) Cost of Spare parts required will be paid and measured separately (2) Servicing/routine check up carried out through authorised service centre of manufacturer (3) Make of spare recommendation by auth service centre of manufacturer. 4. 'B' checl will be carried out after every 250 running Hrs of of DG set or as and when required or directed by Engr-in-charhge 5. Contractor has to depute DG mechanic/technician as and when servicing of DG sets is due and as and when any DG set become unserviceable within 48 Hrs or as directed by Engr-in-charge . In case of failure a recovery of 5000 will be charged for non addressing the complaint of DG set within the given time
320 KVA DG Sets
160 KVA DG Set
100/125 KVA DG Set
82.5 KVA DG Set
63 KVA DG set
35/40 KVA DG set
S&F in replacement of Air Cleaner Element (inner & outer) suitable for following capacity of DG Set. Air cleaner will be changed after every 500 hrs or when reqd complete all as specified and directed.Make MICO/Sakura/ Fleetguard
320 KVA DG Set
160 KVA DG Set
125 KVA DG Set
82.5/100 KVA DG Set
63 KVA DG set
35/40 KVA DG set
S&F in replacement of Fuel filter Element (Primary & Secondary) for following capacity of DG Set: (Fuel filter will be changed after every 250 hrs or when reqd) complete all as specified and directed.
320 KVA DG Set
160 KVA DG Set
125 KVA DG Set
82.5/100 KVA DG Set
63 KVA DG set
35/40 KVA DG set
S&F in replacement of Lub Oil Filter Element for DG Sets of following capacity (Lub oil filter will be changed after every 250 hrs or when reqd) complete all as specified and directed .
320 KVA DG Set
160 KVA DG Set
125 KVA DG Set
82.5/100 KVA DG Set
63 KVA DG set
35/40 KVA DG set
S&F in replacement of ‘V’ belt suitable for alternator of following capacity of DG Sets complete all as directed by Engr in Charge:-
320 KVA DG Set
160 KVA DG Set
125 KVA DG Set
100 KVA DG Set
63 KVA DG set
35/40 KVA DG set
Replacement of 'V' belt for radiator/water pump suitable for following capacity DG Sets complete all as specified and directed by Engr-in-Charge. Make Kirloskar/Cummins/Greaves
320 KVA DG Set
160 KVA DG Set
125 KVA DG Set
100 KVA DG Set
63 KVA DG set
35/40 KVA DG set
Replacement of fuel pipe with banjo bolt at both side suitable for following capacity DG sets complete all as specified and directed by Engr-in-Charge.
320 KVA DG Set
160 KVA DG Set
125 KVA DG Set
100 KVA DG Set
63 KVA DG set
35/40 KVA DG set
Repair of Dynamo/Alternator Assy for following capacity DG Set complete all as specified and directed by Engr-in-Charge.
320 KVA DG Set
160 KVA DG Set
100 /125 KVA DG Set
63 /82.5 KVA DG set
M & L for changing /toping up of best quality of engine oil 20W50 type for various type/capacity DG sets including removing of old burnt engine oil from DG Sets complete all as specified and directed
Supply only cotton waste for daily use for cleaning the DG sets complete all as specified and directed.
Supply and fill batteries distilled water for the DG sets of all Dg set complete all as specified and directed.
Supply and fill batteries electrolyte for the DG sets at all DG Sets complete all as specified and directed.
S&F replacement of auotmatic voltage regulator(AVR) 24 volt all as specified and directed by Engr in Charge.
320 KVA DG Set
160 KVA DG Set
125 KVA DG Set
100 KVA DG Set
63 KVA DG set
M& L for Replacement of water pump assembly for following capacity DG sets complete all as specified and directed by Engr-in-Charge.
320 KVA DG Set
125/100 KVA DG Set
160 KVA DG Set
63/82.5 KVA DG set
Supply and replacement of self starter 12/24 Volt for following capacity DG Set complete all as specified and directed by Engr-in-Charge.
160 KVA DG Set
125 KVA DG Set
100 KVA DG Set
63 KVA DG set
Replacement of Turbo charger assy.for following capacity DG sets complete all as specified and directed by Engr-in-Charge.
160 KVA DG Set
125/100 KVA DG Set
63 KVA DG set
M&L for Replacement of Fan Hub assembely for following capacity of DG Set complete all as specified and directed by Engr in Charge.
160 KVA DG Set
100 KVA DG set
M & L for taking out burnt winding of exciter of following capacity of DG Sets including re-winding copper wire of super quality, of existing size, No of turns, varnishing, heating complete including testing on full load to entire satisfaction of Engr in Charge.
160 KVA DG Set
100/125 KVA DG Set
63 KVA DG set
35/40 KVA DG set
M & L Cleaning of radiator for following capacity DG sets by using Keroscene oil and radiator cleaning solution (Ready to Wash) by pressure of pump and brush and necessary welding/brazing and Re-assembling after painting of the same complete all as directed.
320 KVA DG Set
160 KVA DG Set
125/100 KVA DG Set
63 KVA DG set
35/40 KVA DG set
Supply & fixing in replacement of DC wiring of following capacity of DG Sets , complete all as specified and directed by Engr-in-Charge.
160/100 /125 KVA DG set
35/40/62.5 KVA DG set
Supply & fixing in replacement of Hose Pipe of following capacity of DG Sets complete all as specified and directed by Engr-in-Charge.
160 KVA DG Set
125 KVA DG Set
100 KVA DG Set
63 KVA DG set
35/40 KVA DG set
Supply & fixing in replacement of Oil sensor of following capacity of DG Sets complete all as specified and directed by Engr-in-Charge.
160 KVA DG Set
125 KVA DG Set
100 KVA DG Set
63 KVA DG set
35/40 KVA DG set
Supply & fixing in replacement of Water/Coolent sensor of following capacity of DG Sets complete all as specified and directed by Engr-in-Charge.
160 KVA DG Set
125 KVA DG Set
100 KVA DG Set
63 KVA DG set
35/40 KVA DG set
M&L for Strip opening of alternator 160/125 KVA DG set , removing rotor from the stator and rewinding to CT coils complete with super enameled copper winding wire of appropriate size including insulating material and replacing the following parts of the alternator.Note: Re-assembling all the component of the alternator and mounting the same on the existing foundation including welding of alternator foundation plate by electric arc welding ,aligning the alternator with engine and testing on full load as specified in particular specification and as directed by Engr-in-Charge.
All as per item Ser No.101.00 but DG set of capacity 100/82.5 KVA
Supply and Replacement of lub oil pump suitable for following Capacity DG Sets of existing make and model complete all as specified and directed by Engr-in-Charge.
160/125 KVA DG Set
100/ 63 KVA DG set
Supply and Replacement of Thermostate valve suitable for following Capacity DG Sets complete all as specified and directed by Engr-in-Charge.
320 KVA DG Sets
160 KVA DG Set
125/100 KVA DG Set
63 KVA DG set
35/45 KVA DG set
Supply and Replacement of Oil seal front and rearsuitable side for following Capacity DG Sets Complete all as specified and directed by Engr-in-Charge.
160 KVA DG Set
100/125 KVA DG set
63 KVA DG set
35/40 KVA DG set
Supply and Replacement of battry terminal for DG Sets complete all as specified and directed by Engr-in-Charge.
Supply and fixing battery cable assy. with copper conductor multistranded RED and BLACK colour 2mtr long 20/25 sqmm for connection to self starter unit to Battery unit complete.
M & L for Calibration of Injector unit including supply & fixing in replacement O-Ring, Pin roll, barrel, Pin spring, washer and testing DG Set of capacity up to 320 KVA Set complete all as specified and as directed by Engr in Charge.
M & L for Calibration of FIP including supply & fixing in replacement plunger, DV, governor wet O-Ring, Pin roll, barrel, Pin ball bearing spring, washer and testing for following capacity of DG Set complete all as specified and directed by engr in Charge.
125 KVA DG Set
160 KVA DG Set
63/82.5/100 KVA DG set
35/40 KVA DG set
Dismantling of electronic nozzle 6 Nos from 160 KVA DG Set (Make Cummins) and Calibrate electronic nozel from company and refixing the same and testing all as directed by engineer in charge
All as per item Ser No. 110.00 here in before but DG set of capacity 100 KVA
All as per item Ser No. 110.00 here in before but DG set of capacity 62.5 KVA
M & L for taking out US electronic nozzles from DG Set of Capacity 160 KVA Make Cummins, and S & F new electronic nozzles - 06 Nos of existing make all as specified and directed by Engr-in-Charge
All as per item Ser No. 113.00 here in before but DG set of capacity 100/125 KVA Make 100 KVA - Cummins, 125 KVA - Kirloskar
M&L for supply and fixing in replacement of Crank wheel suitable for 63/125/100 KVA DG set complete all as specified and directed by Engr-In-Charge
Supply and topping up of best quality antifreezing ,inhabitor (Coolant) liquid for DG Set of various capacity and locations complete all as specified and directed.
M & L for replacement of exhaust silencer of 63/100 KVA DG set complete all as specified and directed by Engr in Charge.
M & L Calibration of electronic panel of 160 KVA Cummins DG set with Laptop and fixing all fault including replacement of US relays/wiring as per requirement by cummins engineer all as directed at site
M & L Calibration of electronic panel of 100/125 KVA Cummins DG set with Laptop and fixing all fault including replacement of US relays/wiring as per requirement by cummins engineer all as directed at site
Supply and fixing DG Set battery of 12 V 180 AH including first filling of distrilled water all as directed at site.Make : Exide/Amaron
Supply and fix in repair off load change over switch 415 volt 50 Hz confirm to IS-13947-3 with enclosure and side handle of cap 400 Amp four pole including takind down old switch Make Havells /C&S/Indoasian
Supply and fix in repair off load change over switch 415 volt 50 Hz conform to IS-13947-3 with enclosure and side handle of cap 200 Amp four pole including takind down old switch Make Havells /C&S/Indoasian
M & L for cleaning of fuel tank of DG sets of capacity upto 320 KVA by draining out the fuel and storing in a container for re-filling complete all as specified and directed by Engr-in-charge
M/S TRADE LINK
M/S NISSAR ALI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .