Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC | ₹1.4 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹1.4 Cr+₹36,940 (0.26%)Rejected-Finance 15 281 CHHILI INT ROAD GHATIYA AZAM KHAN AGRA UTTAR PRADESH 282003 | AGRA | UTTAR PRADESH | 282003 | ₹1.4 Cr+₹36,940 (0.26%) | L2 | Rejected-Finance Other Than Being Lowest |
| 3 | L3₹1.5 Cr+₹7.5 L (5.20%)Rejected-Finance SHIVAJI NAGAR GALI NO 1 DHANGU ROAD MODEL TOWN PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹1.5 Cr+₹7.5 L (5.20%) | L3 | Rejected-Finance Other Than Being Lowest |
| Sl No | Description | Qty | Unit | Garima Construction Co L2 | Shetty Construction Co L1 | KEWAL SONS L3 |
|---|---|---|---|---|---|---|
| 1.00 | Dismantling floor, hearth, or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and disposing of unserviceable materials outside MD land, complete all as specified and directed. | 2,881 | Sqm | 45 ₹1,29,645 | 18 ₹51,858 Lowest | 40 ₹1,15,240 |
| 2.00 | M&L for non-skid coloured ceramic tiles 7 to 8 mm thick (square or rectangular), area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid in floors over and including 20 mm thick screed bed in cement mortar (1:6), complete all as specified and directed. | 360 | Sqm | 800 ₹2,88,000 | 800 ₹2,88,000 | 700 ₹2,52,000 Lowest |
| 3.00 | M&L for light-shade double charged vitrified ceramic tiles 10 mm thick (square or rectangular), polished, area of each tile not exceeding 0.36 sqm, set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid in floors over and including 20 mm thick screed bed in cement mortar (1:6), complete all as specified and directed. | 1,110 | Sqm | 1,100 ₹12,21,000 | 1,060 ₹11,76,600 Lowest | 1,200 ₹13,32,000 |
| 4.00 | M&L for light-shade double charged vitrified ceramic tiles 10 mm thick (square or rectangular), polished, area of each tile not exceeding 0.36 sqm, set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid as skirting or dado over and including 15 mm thick backing coat in cement mortar (1:4), complete all as specified and directed. | 161 | Sqm | 1,150 ₹1,85,150 | 1,140 ₹1,83,540 Lowest | 1,250 ₹2,01,250 |
| 5.00 | M&L for coloured glazed ceramic tiles 450 × 300 × 7 mm / 350 × 250 × 7 mm thick, as on vertical surfaces such as skirting or dado, set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 15 mm thick backing coat in cement mortar (1:4), complete all as specified and directed. | 1,250 | Sqm | 950 ₹11,87,500 | 940 ₹11,75,000 | 750 ₹9,37,500 Lowest |
| 6.00 | Taking down chowkats or frames not exceeding 1.5 sqm each, with shutters (without taking shutters off from the frames), complete all as specified and directed. | 84 | Each | 125 ₹10,500 | 75 ₹6,300 Lowest | 100 ₹8,400 |
| 7.00 | Taking down chowkats or frames exceeding 1.5 sqm but not exceeding 4 sqm each, with shutters (without taking shutters off from the frames), complete all as specified and directed. | 216 | Each | 150 ₹32,400 | 100 ₹21,600 Lowest | 115 ₹24,840 |
| 8.00 | S&F 2nd class hardwood plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed. | 2.3 | Cum | 38,000 ₹87,400 | 42,000 ₹96,600 | 25,000 ₹57,500 Lowest |
| 9.00 | S&F 35 mm thick flush shutters, solid core construction, with blockboard core and commercial plywood face panels on both sides, commercial type, complete all as specified and directed. | 105 | Sqm | 2,500 ₹2,62,500 | 1,650 ₹1,73,250 Lowest | 2,350 ₹2,46,750 |
| 10.00 | Supply & fixing in repairs powder coated aluminium sections for partitions, windows, ventilators and doors including fabrication of frame/shutters and fixing to walls/floors with necessary lugs, cleats etc including all accessories such as glazing clips, handles, tower bolts, rollers rubber beadings for fixing glass panes in frame including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required complete all as specified
Note: - (i) Glass panes will be measured & paid separately.
(ii) The rate quoted shall be inclusive of neoprene beading, glazing clips, screws, etc. as required but shall not be measured for arriving of weight.
(iii) Minimum thickness of powder coating shall be 25 micron.
(iv) The rate shall be inclusive of the locking arrangement including complete packing with silicon gel around contacting surface of aluminium work with matching existing area.
(v) The size of aluminium sections shall be as per HQ CE(N) MZ TD drawing No TD/2021/01 to 05 | 1,700 | Kg | 525 ₹8,92,500 | 585 ₹9,94,500 | 480 ₹8,16,000 Lowest |
Tender Value
₹1.5 Cr
EMD Value
₹2.2 L
Closing Date
25 Feb 2026, 6:00 pmClosed
CWE (NW) Mumbai
CWE (NW) Mumbai
SPECIAL REPAIR TO NAVAL FLATS AT HARBOUR HEIGHTS UNDER GE NW NOFRA, MUMBAI
2025_MES_745588_2
8680/CWE(NW)Mumbai/E8
Open Tender
Civil Works
Item Rate
300 days
GE (NW) NOFRA
Class B
Category a (i)
7 documents required · 7 mandatory
₹1,000
GE (NW) NOFRA
₹2.2 L
Yes
23 Mar 2026
12 Feb 2026
27 Feb 2026
12 Feb 2026
25 Feb 2026
20 Feb 2026
12 Feb 2026 - 19 Feb 2026
Dismantling floor, hearth, or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and disposing of unserviceable materials outside MD land, complete all as specified and directed.
M&L for non-skid coloured ceramic tiles 7 to 8 mm thick (square or rectangular), area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid in floors over and including 20 mm thick screed bed in cement mortar (1:6), complete all as specified and directed.
M&L for light-shade double charged vitrified ceramic tiles 10 mm thick (square or rectangular), polished, area of each tile not exceeding 0.36 sqm, set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid in floors over and including 20 mm thick screed bed in cement mortar (1:6), complete all as specified and directed.
M&L for light-shade double charged vitrified ceramic tiles 10 mm thick (square or rectangular), polished, area of each tile not exceeding 0.36 sqm, set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid as skirting or dado over and including 15 mm thick backing coat in cement mortar (1:4), complete all as specified and directed.
M&L for coloured glazed ceramic tiles 450 × 300 × 7 mm / 350 × 250 × 7 mm thick, as on vertical surfaces such as skirting or dado, set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 15 mm thick backing coat in cement mortar (1:4), complete all as specified and directed.
Taking down chowkats or frames not exceeding 1.5 sqm each, with shutters (without taking shutters off from the frames), complete all as specified and directed.
Taking down chowkats or frames exceeding 1.5 sqm but not exceeding 4 sqm each, with shutters (without taking shutters off from the frames), complete all as specified and directed.
S&F 2nd class hardwood plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed.
S&F 35 mm thick flush shutters, solid core construction, with blockboard core and commercial plywood face panels on both sides, commercial type, complete all as specified and directed.
Supply & fixing in repairs powder coated aluminium sections for partitions, windows, ventilators and doors including fabrication of frame/shutters and fixing to walls/floors with necessary lugs, cleats etc including all accessories such as glazing clips, handles, tower bolts, rollers rubber beadings for fixing glass panes in frame including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required complete all as specified Note: - (i) Glass panes will be measured & paid separately. (ii) The rate quoted shall be inclusive of neoprene beading, glazing clips, screws, etc. as required but shall not be measured for arriving of weight. (iii) Minimum thickness of powder coating shall be 25 micron. (iv) The rate shall be inclusive of the locking arrangement including complete packing with silicon gel around contacting surface of aluminium work with matching existing area. (v) The size of aluminium sections shall be as per HQ CE(N) MZ TD drawing No TD/2021/01 to 05
S&F aluminium grill with and including suitable aluminium anodised frame F/H section as requird manufactured by M/S Decogrill as per design No DG- 104, 7.5 mm thick all as specified and as directed by Engr- in- charge.
S & F Factory made single extruded WPC (Wood Ceosetory windows & other Frames/Chowkhat of size 45 x 85 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive trength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge.
S & F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N edge),minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire ardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, with wood free EPS all as per direction of Engineer-In-Charge.
S&F 3 mm thick frosted or obscured glass panes, glazing with new or old wooden/aluminium beads, size exceeding 0.5 sqm each, complete all as specified and directed.
M&L for preparing new wooden surfaces of any description exceeding 10 cm in width or girth and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified and directed.
M&L for preparing old painted wooden surfaces of any description exceeding 10 cm in width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed.
S&F aluminium alloy sliding door bolt, 300 mm long, hasp and staple (bolt type), with fixing clips of cast or extruded section, complete with bolts and nuts, complete all as specified and directed.
S&F aluminium anodised barrel tower bolts 200 mm long, of extruded section, complete all as specified and directed.
S&F aluminium anodised barrel tower bolts 150 mm long, of extruded section, complete all as specified and directed.
S&F aluminium alloy handles, 150 mm size, cast type, anodised, ISI marked, complete all as specified and directed.
S&F stainless steel butt hinges 125 mm, medium weight, fixed complete all as specified and directed.
M&L for Mild-Steel flat for holdfasts, wind ties, etc., conforming to Fe-310-0 or Fe-410-0, complete all as specified and directed.
S&F floor door stopper, aluminium alloy body and tongue, 150 mm long, anodised finish with hard-drawn steel spring, complete all as specified and directed.
MM&L for cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in bed blocks or similar work, complete all as specified and directed.
S&F 7-lever Godrej Night Latch, brass or steel, complete all as specified and directed.
S&F in repair brass “magic eye” peep hole for entrance door shutter, complete all as specified and directed.
Re-securing, easing, and adjusting shutters of any description, area exceeding 1 sqm but not exceeding 2 sqm each, without taking down, complete all as specified and directed.
S&F in repairs sliding door bolt 300 mm long, aluminium alloy, with hasp & staple (bolt type), including fixing clips, bolts, and nuts, complete all as specified and directed.
S&F in repairs aluminium anodised barrel tower bolt 200 mm long, extruded section, complete all as specified and directed.
S&F in repairs floor door stopper, aluminium alloy body and tongue, 150 mm long, anodised, complete all as specified and directed.
SS&F in repairs aluminium alloy handles, 150 mm size, cast type, anodised, ISI marked, complete all as specified and directed.
S&F in repairs 7-lever Godrej Night Latch, complete all as specified and directed.
S&F in repairs vitreous china wash-down closet, white, wall-hung or pedestal type, with ‘P’ or ‘S’ trap, including soft-close seat cover, chromium-plated hinges, connecting accessories, flushing and anti-syphonage pipes, and fixing screws, complete all as specified and directed.
S&F in repairs vitreous china squatting pan (Orissa pattern), 580 × 440 mm, white, with integral footrests, including connection to trap and flushing pipe, complete all as specified and directed.
S&F in repairs low-level PVC flushing cistern, 10-litre capacity, with internal fittings, handle, and 32 mm dia PVC flush pipe, complete all as specified and directed.
S&F in repairs vitreous china wash-hand basin, white, flat back, 550 × 400 mm, with CI brackets, CP waste coupling, PVC waste pipe and connection to floor trap, complete all as specified and directed.
S&F in repairs 15 mm bore pillar tap, cast copper alloy, CP finish, capstan head, screwed down high-pressure type, fixed complete all as specified and directed.
S&F in repairs health faucet (ABS body), with 8 mm dia flexible tube and wall hook, complete all as specified and directed.
S&F in repairs aluminium anodised tubular towel rail, 20 mm dia, D-type, 600 mm long between flanges, complete all as specified and directed.
S&F as in repairs brass chromium plated shower rose 125mm size, including fixed to steel tube, complete all as specified.
S&F shower arm 15 mm dia, 195 mm long with 45° bend and flange, PTMT body, any colour, minimum mass 40 gm, complete as specified and directed.
S&F two-way bib taps, chromium finish, screwed-down type, fixed in position, complete with washers and fixing accessories, all as specified and directed.
Taking down 15 mm old steel tubing and associated connections and refixing in new or original positions (walls, ceilings, floors etc.), including making good, complete as specified and directed.
S&F CPVC pipes 20 mm bore having thermal stability for hot and cold water supply, including all plain and brass-threaded fittings of required sizes, fixed to walls, ceilings, or laid in floors or concealed as required, with suitable clamps and accessories,including taking down old unserviceable tubing and making good disturbed surfaces, complete all as specified and directed by Engineer-in-Charge. Note: (1)Quoted rate shall be deemed to include provision of necessary scaffolding, safety gear, and handling arrangements for execution of work in high-rise buildings as directed at site.
S&F in repairs CP bib cock 15 mm bore complete all as specified and directed.
S&F short CI sanitary connection, upto 100 mm dia (for short connection to fixture), pipe length not exceeding 300 mm, complete as specified and directed.
S&F in repairs cast iron floor trap 75 mm dia with grating, jointed to waste with cement mortar and fixed in cement concrete base as required, complete all as specified and directed.
S&F recessed type Toilet paper holder, stainless-steel, fixed with suitable screws on wall/tiles, complete as specified and directed.
S&F (in repairs) PVC bathroom cabinet with 4 mm looking mirror overall size 450 × 300 mm, approved tint/pattern, fixed and drilled with 2 Nos chromium-plated screws, complete as specified and directed.
S&F PVC connection 15 mm size with PTMT nut, length 600 mm, complete as specified and directed.
S&F stop/angle valve (fancy type) 15 mm bore, chromium-plated, screwed down, high-pressure type with butterfly handle, screwed both ends for 15 mm pipe, complete as specified and directed.
S&F 15 mm brass CP mixer for mixing hot & cold water, screwed down for iron pipe and fixed as directed, complete as specified and directed.
S&F in repairs soap-dish holder of any approved type, fixed to plugs with chromium-plated brass screws, complete as specified and directed.
S&F decorative corner glass shelf, size 300 × 120 mm, 8 mm thick, with 25 mm high railing, edges rounded, supported on chromium-plated brass brackets fixed with chromium-plated brass screws to plugs, complete as specified and directed.
S&F 100 mm CI ‘P’ or ‘S’ trap, jointed with neat cement paste, fixed to wall or roof at any floor/height including all necessary fittings, complete as specified and directed by EIC.
Taking down cement plaster, any description, on brick, stone, or concrete walls including raking out joints, hacking for key, scrubbing down with water, and disposing of debris outside MD land, complete all as specified and directed. Note: The quoted rate shall be deemed to include provision of all necessary scaffolding, safety arrangements, and staging platforms required for working at heights as directed at site.
M&L for rendering 15 mm thick in cement mortar (1:6) on brick or concrete surfaces, finished even and smooth without using extra cement, including preparation of surfaces, complete all as specified and directed. Note: The quoted rate shall be deemed to include provision of steel scaffolding, working platforms, safety belts, and arrangements required for safe execution of plastering work in high-rise buildings as directed by the Engineer-in-Charge.
M&L for plastering 10 mm thick in cement mortar (1:3) on ceiling surfaces, finished even and smooth without using extra cement, including preparation of surfaces, curing, and making good to edges and corners, complete all as specified and directed by the Engineer-in-Charge. Note: The quoted rate shall be deemed to include provision of all necessary steel scaffolding, staging, working platforms, ladders, safety gear, and protective arrangements required for execution of ceiling plastering work in high-rise buildings as directed at site.
M&L for preparation of newly plastered wall surfaces and applying two coats of oil-bound distemper over one coat of primer on 2 mm wall care putty , complete as specified and directed.
M&L for preparation of newly plastered ceiling surfaces and applying two coats of oil-bound distemper over one coat of primer on 2 mm wall care putty , complete as specified and directed.
M&L for complete removal of existing wall treatment and preparation of old distempered/painted surfaces and applying two coats of oil emulsion distemper over one coat of primer and 1–2 mm wall care putty , complete as specified and directed.
M&L for preparation of old plastered ceiling surfaces and applying one coat of oil emulsion distemper on ceiling, complete as specified and directed.
S&F in repairs fancy drapery rods, powder-coated aluminium, 20–25 mm size, including fixing brackets, screws and accessories, complete as specified and directed.
M&L 18 to 20 mm thick machine cut mirror polished Granite work (any type), table/rubbed & polished, e.g., steps, jambs, pillars, window-cills, cooking platforms and similar, including 15 mm thick screed bed (1:4), pointing in white cement (1:2) with marble dust and pigment to match, moulding and rounding, complete as specified and directed.
M&L for machine-cut cuddapah stone slab 22–25 mm thick, bedded and jointed with grey cement slurry mixed with pigment to match shade, including rubbing and polishing, complete as specified and directed.
S&F in repairs stainless-steel sink with draining board, 1.0 mm thick, kitchen or laboratory type, complete with plugs, washers and waste; bedding in cement mortar to dwarf wall or fixing cantilever brackets and connecting union to pipe; overall size 915 × 460 mm bowl size 410 × 330 × 160 mm, complete as specified and directed.
S&F in repairs long-neck kitchen sink tap, approved make, fixed complete as specified and directed.
S&F 38 mm dia PVC flexible waste pipe, 800 mm long for kitchen sink, complete as specified and directed.
S&F in repairs stainless-steel plate rack of size 900 × 580 × 210 mm, fixed to wall with screws, complete as specified and directed.
M&L for 18mm thick Marine plywood, grade BWP, type BB with both side 0.9mm thick decorative choice laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instruction,fixed with screws to timber frame work including 1st class HW lipping alround the shutter/edges and polishing etc as in kitchen cupboard/ wardrobe shutters complete all as specified and directed.
S&F stainless steel kitchen baskets for storage of plates, cups, bottles etc., made out of stainless steel of grade SS 304 not less than 6 to 8 Kg each using square hollow tubes of size 12mm x 12mm x 1.25mm thick for framework as required and solid round bars / 26 guage thick sheet to make desired pattern, suitable for sliding under kitchen platform on a pair of channels, including fixing with steel screws, fixed in repairs, complete. Note : (i) Telescopy channels shall be measured and paid under separate item.
S&F telescopic channels, powder-coated with ball bearings, suitable for sliding stainless-steel kitchen basket, 600 mm long standard width, fixed over 2nd class hardwood rectangular fillet (area exceeding 3 cm² and not exceeding 6 cm²), secured with screws to cuddapah stone where required, complete as specified and directed.
S&F 100 mm long fancy extruded brass handle, fabricated type, fixed with nut, screw and washer, complete as specified and directed.
S&F 150 mm long fancy extruded brass handle, fabricated type, fixed with nut, screw and washer, complete as specified and directed.
S&F continuous piano hinge (30 mm flap) stainless steel, bright finish, fixed with mild-steel screws, complete as specified and directed.
S&F plastic body magnetic catcher with iron plate to be fixed to cabinet shutters, approved pattern/shape, fixed with screws on wooden/plywood surfaces, complete as specified and directed.
Treatment of sunken floor slab compraises of the following specifications and all as specified :- (i)M&L for cleaning the sunken/lowered portion of RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely. 40mm thick avg PCC 1:2:4 type B-0 using 12.5mm graded aggregate as in padding concrete to achieve proper slope including cutting holes in bricks or RCC wall for spout (Cost cutting holes and pipes shall be measured and paid separately). (ii) Rendering of uneven surfaces with 6mm thick CM 1:4 mixed with integral water proofing compound @ 3% by wt of cement consumed. Fill it with water and check dampness and seepage. Where dampness/seepage is noticed, nozzles shall be fixed and grouting carried out.( WPC shall be measured & paid separately). (iii)All junctions points of side wall where CI/GI pipes are passing through shall be sealed with epoxy putty. (iv)After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean. (v) M&L for applying two coats of polymer modified cementious water proof coating as per manufacturs instruction to bottom and vertical sides up to finished floor level+100mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed.(This item shall be measured and paid separately) (vi)Plaster the bottom and sides up to bottom of the skirting with minimum 20mm thick CM 1:4 mixed with integral water proofing compound 3% by wt of cement consumed as per manufacturer's specification including rounding of corners and junctions sloping towards spout.( WPC shall be measured & paid separately)
(vii)All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 all round after painting with anticorrosive paint (this item shall be measured & paid separately). Note :- Test the water proofed area (ponding test) by filling water for at least 72 hours and tested for leakage seepage and to the entire satisfaction of GE. Cost of testing is included in the rates quoted above.
Cutting holes in brick or RCC walls (excluding half-brick walls) for insertion of spouts etc., making good the openings and finishing, complete all as specified and directed.
Supply and fixing 25 mm bore GI tubing medium grade with all fittings such as bends, socket, tees, elbows, unions, barrel, nipple, plugs, etc laid in floors with suitable size GI clamps complete all as specified.
M&L for applying two coats of polymer modified cementious water proof coating as per manufacturs instruction to bottom and vertical sides up to finished floor level+100mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed.
M & L Injection grouting in RCC slab shall be cast/laid to the slope as directed/as per site conditions. After RCC slab is laid, cured and fully set, water shall be ponded in the sunken slab portion as per specified ponding test. The location of seepage/leakage, if any, shall be identified and marked. The portion of the slab where leakage/seepage is observed shall be repaired with grouting at contractor's expences. The area of dripping/leakage shall be cleaned to expose the surface. Mark the spots for injection grouting. If leakage is through a crack, mark grouting points along the crack in a staggered manner. If the leakage is across the area mark grouting spots in a grid pattern. Drill grouting holes so as to neatly fit the injection packers. Drilling to be done at an angle of 45 to the plane of grouting surface. Fix PVC/MS nozzles in the low viscosity, injecting polyurethane resin/epoxy grout using a grouting pump. Repeat the process after 1 or 2 days if the leakage continues at some point. allow to cure for 24 hours and seal the grouting holes appropriately using epoxy putty etc complete all as specified and as directed.
Removing of dismantled/ demolished material / old debris/tiles etc by mechanically or manually, outside MD land as and when directed.
M&L plain cement concrete (PCC) 1:4:8 with brick aggregate for lean concrete/filling works as in general filling or sub-base, complete all as specified and directed.
Supply only Integral water proofing compound complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including all fittings and accessories such as switches, ceiling roses, pendants, regulators, sockets, light fittings, etc. Removing materials to store for safe custody or credit (credit for taken-down items shall be as per conditions separately) and making good disturbed surfaces of walls, ceilings, and floors complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring in existing buildings conforming to IS 732:1989, complete with 1.5 sq mm single-core multi-stranded FRLS PVC insulated unsheathed copper conductor (1100 V grade, confirming to IS 694:2010) drawn through and including rigid non-metallic PVC medium-grade concealed conduit of suitable size (thickness not less than 1.2 mm, ISI-marked) with all accessories, including modular metal flush boxes concealed in walls and one FRLS PVC insulated and unsheathed multi-stranded green copper conductor 1.5 sq mm as earth continuity conductor connected to common earth dolly.
(a) One light point controlled by one switch SP one way.
(b) One ceiling fan point controlled with one 5A switch
(c) One exhaust fan point controlled with one 5A switch
(d) One 3 pin socket outlet 5Amps on independant board.
(e) One 3 pin socket outlet 5Amps on same board with other switches.
(f) One bell pont controlled by one bell push 5 amps independent board.
All as per Item No. 88 above, but using 2.5 sq mm FRLS PVC insulated unsheathed multi-stranded copper conductor (1100 V grade) drawn through concealed conduit with 2.5 sq mm green copper earth continuity wire connected to common earth dolly, including all accessories complete all as specified and directed. Notes: (i) Circuit conductor from MCB DB to switchboards shall not be less than 2.5 sq mm. (ii) Separate circuit shall be drawn from MCB; no tapping from light circuit is permitted. (iii) Modular metal flush boxes shall be measured and paid under relevant items separately.
S&F Modular switch 6 Amp, 1 Module, one way, ISI marked complete all as specified and directed.
S&F Modular switch 16 Amp, 1 Module, one way, ISI marked complete all as specified and directed.
S&F Modular type bell push 6 Amp, 1 Module, ISI marked complete all as specified and directed.
Supply and fix electric door bell AC 230 Volt single pole “ding-dong” type ISI marked complete all as specified and directed.
S&F Modular socket 6 Amp, 2/3 pin combined, 3 Module, ISI marked complete all as specified and directed.
S&F Modular socket 16 Amp, 6 pin combined, 3 Module, ISI marked complete all as specified and directed.
S&F Modular electronic fan regulator 5 step, 120 Watt, 230 Volt, 2 Module, ISI marked complete all as specified and directed.
S&F Ceiling rose, surface or flush type, bakelite, ISI marked, three terminals complete all as specified and directed.
S&F Modular white cover plate with frame, 1 Module, ISI marked complete all as specified and directed.
S&F Modular white cover plate with frame, 2 Module, ISI marked complete all as specified and directed.
S&F Modular white cover plate with frame, 3 Module, ISI marked complete all as specified and directed.
S&F Modular white cover plate with frame, 4 Module, ISI marked complete all as specified and directed.
S&F Modular white cover plate with frame, 6 Module, ISI marked complete all as specified and directed.
S&F Modular white cover plate with frame, 8 Module, ISI marked complete all as specified and directed.
S&F Modular white cover plate with frame, 12 Module, ISI marked complete all as specified and directed.
S&F Modular metal flush box 1/2 Module, ISI marked complete all as specified and directed.
S&F Modular metal flush box 3 Module, ISI marked complete all as specified and directed.
S&F Modular metal flush box 4 Module, ISI marked complete all as specified and directed.
S&F Modular metal flush box 6 Module, ISI marked complete all as specified and directed.
S&F Modular metal flush box 8 Module, ISI marked complete all as specified and directed.
S&F Modular metal flush box 12 Module, ISI marked complete all as specified and directed.
S&F LED batten type integral sleek extruded polycarbonate fitting with white acrylic cover, 1x18 Watt (min 120 lumen/watt) warm white, internally prewired, including connection with twin core flexible copper conductor complete all as specified and directed.
S&F LED batten type integral sleek extruded polycarbonate fitting with white acrylic cover, 1x10 Watt, (min 120 lumen/watt) warm white, internally prewired, including connection with twin core flexible copper conductor complete all as specified and directed.
M&L for PVC/polycarbonate lamp holder with cord grip cap suitable for pendant fittings complete all as specified and directed.
S&F LED lamp 12 Watt (min 120 lumen/watt), 240 Volt, 50 Hz, AC supply, luminous flux 1450 lumens complete all as specified and directed.
Supply and Fix double door type distribution board (DB), 16-way (MCB type), suitable for single-phase 240 Volts, with IP–42 protection, fabricated from powder-coated CRCA steel sheet, fitted with 200 Amps rated tinned copper bus bar, neutral link, and earth bar, including interconnection with existing wiring using suitable size copper lugs/pin terminals, mounting on wall, making all electrical connections, testing, and commissioning complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repair ISI marked 40 Amp, 30mA, 230V, DP RCBO, conforming to IS:12640 (Part 2)-2016, having front face indication for earth leakage fault, sliding bottom clamp, colour coded on/off indication on dolly, biconnect IP20 protected lower terminals and sliding shutters, complete all as specified and directed by the Engineer-in-charge.
Supply and fix MCB SPN 40 to 63 Amp, 240 Volt, C Series complete all as specified and directed.
S&F MCB SP 6 to 32 Amp, 10 kA rating complete all as specified and directed.
Supply and fix sub-main wiring comprising two runs of 4 sqmm single core FRLS PVC insulated 1100 Volt grade stranded copper conductor and one run of 4 sqmm green colour earth wire, drawn through PVC casing and capping not less than 25 mm size ISI marked, complete all as specified and directed. Note : The quoted rate shall be deemed to include the cost of all accessories, fixing materials, and proper dressing of wires inside casing. For the purpose of measurement, two runs of main conductors, one run of earth continuity conductor, and one run of PVC casing and capping (or conduit) shall together be measured as one complete run.
Supply and fixing Submain wiring with proper colour coding, 2 single core FRLS 1100 volts grade cable with stranded copper conductor of size 10 Sqmm in and including PVC casing and caping of suitable size not less than 25 mm , ISI marked including 1 single core cable with stranded copper conductor of size 10 Sqmm (green colour) for earthing. Make of cable: Plaza/ Havelles/ Finolex. Make of PVC Casing caping : Finolex/ Precision/ Plaza. Note: The quoted rate shall be deemed to include the cost of all accessories, fixing materials, and proper dressing of wires inside casing. For the purpose of measurement, two runs of main conductors, one run of earth continuity conductor, and one run of PVC casing and capping (or conduit) shall together be measured as one complete run.
S&F Plug and Socket enclosure in sheet metal with SP MCB 20 Amp, 240 Volt complete for window type air conditioner complete all as specified and directed.
S&F and testing wall mounted auto clean electric Ducted chimney, 220 Volt, touch control, black tempered glass, heat auto-clean, 2x1.5W LED lamp, suction capacity not less than 1350 cum/hr, filterless with stainless steel oil collector, with a noise level of less than 60 decibels (dB) complete all as specified and directed.
&F aluminium flexible exhaust pipe 150 mm dia, 8.5 to 10 feet long with end cap and clamps including cutting circular opening in wall, inserting PVC sleeve and sealing complete all as specified and directed.
S&F copper chromium plated hot water extension pipe 450 mm long with brass adaptor and fixing in position complete all as specified and directed.
Supply and fix in repair 450mm long PVC connector with brass adaptor, washer and fixing in position complete all as specified.
Taking down ceiling fan and overhauling of ceiling fan any size and Make, dismantling parts, properly cleaning/removing old existing grease, oil and applying new oil grease, varnishing for winding, new winding of ceiling fan with copper wire, cleaning dust, rust and replacing petty items with new as required such as Nuts, Bolts, washers, bushes, ball bearing, cap, fan shaft, rotor, capacitor 2.5 Mfd, body cover etc and reassembling, connecting with copper conductor multi stranded 3 core wire of size 14/0.0076 including one coant of synthetic enamel paint and connecting to new ceiling fan safety wire complete and testing and refixing the same its original postion after repair complete all as specified and directed by Engr in Charge.
Taking down exhaust fan of any size and overhauling of exhaust fan any size and Make, dismantling parts, properly cleaning/removing old existing grease, oil and applying new oil grease, varnishing for winding, new winding of ceiling fan with copper wire, cleaning dust, rust and replacing petty items with new as required such as Nuts, Bolts, washers, bushes, ball bearing, cap, fan shaft, rotor, capacitor 2.5/4.0 Mfd, body cover etc and reassembling, connecting with copper conductor multi stranded 3 core wire of size 14/0.0076 including one coant of synthetic enamel paint complete and testing and refixing the same its original postion after repair complete all as specified and directed by Engr in Charge.
S&F modular TV socket ISI marked including flush box, cover plate and frame complete all as specified and directed.
S&F telephone socket RJ-45 ISI marked including flush box, cover plate and frame complete all as specified and directed.
M&L for rigid non-metallic medium grade ISI marked PVC conduit not less than 20 mm dia and 1.2 mm thick concealed in wall with junction boxes, bends, elbows, couplers, lock nuts and accessories complete all as specified and directed.
Material and Labour for supplying and installing PVC mini trunking of size 32 mm × 20 mm × 1.5 mm thick, including all required finishing accessories such as flexible cover, internal and external angles, end caps, base joints, clip partitions, and derivations, suitable for electrical/signal/telephone wiring. Trunking shall conform to EN 50085-2-1 and NF C 68-104 standards, with minimum IP 40 degree of protection and IK 07 mechanical impact resistance, made of non-flame-propagating PVC in white colour (RAL 9003). The work shall include fixing to wall, ceiling, or other surfaces with all necessary hardware and making good disturbed portions, complete all as specified and directed by the Engineer-in-Charge.
Taking down existing geyser and check the serviceability of geyser and replace the minor parts heating elemant, thermostate, indicator lamp, nut bolts, washers,thermal cut out, fastners, stop leakage from inner tank and replace the top plug and one coat of sybthetic enamel paint and refix the same in its original position complete all as specified and directed by Engr in Charge.
Note for all items above 1)The tenderer shall note that before quoting his unit rates, all items of work shall be executed in a high-rise building and shall include provision of necessary scaffolding and safety measures. 2)Debris shall be removed from time to time as directed by the Engineer-in-Charge. 3)Any damage caused to the RCC structure or adjoining portions during demolition or dismantling, due to negligence of the contractor, shall be made good by the contractor at his own expense. 4)Safety Precaution: Necessary safety precautions for men, material and structures shall be taken by the contractor during execution of work. 5)Necessary steel scaffolding shall be provided by the contractor for multistoried buildings. The contractor shall ensure that all workmen wear safety belts at all times. 6)The work shall be carried out while the building remains partially occupied in Phases as given in SCH A NOTES 7) Work shall be carried out as per rules of the HARBOUR HEIGHT A CO-OPERATIVE HOUSING SOCIETY LTD as given in Special Conditions and recoveries of Rs 200 per day per flat (for the contract and extended period if any)and others shall be paid directly to the society by the contrator. The amount for the same shall be included in the rate quoted by the contractor for respective items. NO CLAIM in this regards shall be entertained by the department. The contractor shall submit to the department NOC from the society for issuing of completion certicate. 8)The quoted rate for all items shall be deemed to include compliance with all the above conditions.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
8680.rar
Tender Documents • 3.34 MB
BOQ_842741.xls
BOQ • 1.79 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .