Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.2 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹15.6 L+₹1.3 L (9.23%)Rejected-AOC 03 PATEL STREET GANDHI NAGAR AVADI TIRUVALLUR TAMIL NADU 600054 | THIRUVALLUR | TAMIL NADU | 600054 | L2 | Rejected-AOC Rejected | |
| 3 | Rejected-Technical D NO 71 31 252 DURGANAGAR MALKAPURAM VISAKHAPATNAM 530011 | VISAKHAPATANAM | ANDHRA PRADESH | 530011 | - | Rejected-Technical Firm asked to provide proof for experience in execution of AC work not provided till date. Hence Rejected |
Tender Value
₹14 L
EMD Value
₹28,000
Closing Date
5 Mar 2020, 6:00 pmClosed
GARRISON ENGINEER M
GARRISON ENGINEER M NAVAL AIR STATION ARAKKONAM - 631006
SPECIAL REPAIRS FOR REPLACEMENT OF BER DECLARED WINDOW TYPE AND SPLIT TYPE AIR CONDITIONERS WITH SINGLE PHASE VOLTAGE STABILIZERS (PHASE-III) AT INS RAJALI ARAKKONAM
2020_MES_322957_1
8873 OF 2019-2020
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
GE M NAS ARAKKONAM
Please refer tender documents
7 documents required · 7 mandatory
₹500
Yes
GE M NAS ARAKKONAM
₹28,000
Yes
16 Mar 2020
20 Feb 2020
7 Mar 2020
20 Feb 2020
5 Mar 2020
20 Feb 2020
Amount
Supply and install air cooled split air conditioner electric driven single phase of capacity of 1.5 TR with copper condenser coil, green gas, mounting stand with all accessories, 100% copper (for indoor, outdoor units and mounting kits) as per BEE "Ministry of Power" Government body ISEER table valid from 2018 to Dec 2020 equivalent to 5 star rating of EER for Jan 2016 to Dec 2017 complete all as specified and as directed by Engr-in-charge. Note: Extra length of copper tubing with insulation, as per site requirement is deemed to be included in the rate quoted. Make: Blue star model No.IC318XBTU/ Carrier Model No.CA 118DF3N8FO/ Voltas Model No.183VJ
Supply and install air cooled split unit air conditioner electric driven single phase of capacity of 2 TR with copper condenser coil, green gas, mounting stand with all accessories 100% copper (for indoor, outdoor units and mounting kits) as per BEE "Ministry of Power" Government body ISEER table valid from 2018 to Dec 2020 equivalent to 5 star rating of EER for Jan 2016 to Dec 2017 complete all as specified and as directed by Engr-in-charge. Note: Extra length of copper tubing with insulation, as per site requirement is deemed to be included in the rate quoted. Make: Blue star model No.IC3124XBTU /Carrier Model No.CA 124DF3N8FO/ Voltas Model No.243VJ
Supply and install voltage stabilizer for automatic operation single phase nautral air cooled indoor type and designed for input variation between 90 V to 300 V with output voltage stabilised at 230 V with accuracy +/- 2.5% and capacity 4 KVA complete all as specified and as directed by Engr-in-charge. Make: V-Guard / Shakti /Zenith /Volina
Supply and install voltage stabilizer for automatic operation single phase nautral air cooled indoor type and designed for input variation between 90 V to 300 V with output voltage stabilised at 230 V with accuracy +/- 2.5% and capacity 5 KVA complete all as specified and as directed by Engr-in-charge. Make: V-Guard/ Shakti/ Zenith/ Volina
Supply and fix for sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with one MCB SP 'C' curve 20 to 32 Amps complete all as specified and as directed by Engr-in-charge. Make: Legrand/ Seimens/ ABB/ Schneider
Taking down unserviceable sub main wiring of any size along with earth wire of any sizes complete all as specified and as directed by Engr-in-charge.
Material and labour for sub main wiring PVC insulated, unsheathed FRLS cable, 1100 volts grade, multi stranded with copper conductor of 2X6 sqmm for phase and neutral and 1X6 sqmm as earth wire, drawn through and including suitable size of PVC conduit pipe and accessories complete all as specified and as directed by Engr-in-charge. Make: Finolex/ Plaza/ Polycab/ Universal/ Gloster
Material and labour for cutting chases on brickwork concrete surfaces not exc 10cm girth and making good in cement mortar (1:3) the existing surface after carrying out the concealed wiring including necessary finishes complete all as specified and as directed by Engr-in-charge.
Cutting into old masonry to form toothings and bonding in new brick or stone work including making good in mud mortar complete all as specified and as directed by Engr-in-charge.
Material and labour for brick work with subclass 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and as directed by Engr-in-charge.
Material and labour for rendering 10mm thick on fair faces of brick work or concrete surface in CM 1:6 complete all as specified and as directed by Engr-in-charge.
Material and labour for rendering 15mm thick on fair faces of brick work or concrete surface internal surfaces of walls in CM 1:4 surfaces finished even and smooth without using extra cement complete all as specified and as directed by Engr-in-charge.
Material and labour for preparation of new plastered surfaces and apply two coats of external weather proof paint over a coat of algea proof acrylic primer on RCC masonry walls etc, manually to achieve required finishes complete all as specified and as directed by Engr-in-charge.
Material and labour for two coats of OBD over priming coat on newly plastered surfaces of wall including preparation of surfaces complete all as specified and as directed by Engr-in-charge.
Material and labour for removing of BER declared window/ split ACs of any make /size along with voltage stabilizers metal enclosure stand refrigerator copper pipes and all connected accessories and deposit the AC and voltage stabilizers to MES store yard complete all as specified and as directed by Engr-in-charge.
SIVA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .