Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹6.8 LAccepted-AOC HYDERABAD TELANGANA 500076 INDIA UDYAM TS 02 0009467 | MEDCHAL MALKAJGIRI | TELANGANA | 500076 | 1 | Accepted-AOC Lowest | |
| 2 | 2₹8.5 L+₹1.5 L (20.7%)Rejected-Finance | 2 | Rejected-Finance Other than Lowest |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
19 Jul 2024, 6:00 pmClosed
AGE (I) Highground
AGE (I) Highground Chandigarh
REPAIR AND MAINTENANCE OF DG SETS,STREET LIGHTS,SECURITY LIGHTS,HIGH MAST LIGHTS AND OTHER CONNECTED ITEMS AT AIR FORCE STATION MULLANPUR UNDER AGE (I) HIGHGROUND CHANDIGARH
2024_MES_661224_1
AGE(I)/HG CHD/T-11/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE (I) Highground Chandigarh
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE (I) Highground
₹20,000
Yes
10 Jan 2025
21 Jun 2024
26 Jul 2024
21 Jun 2024
19 Jul 2024
5 Jul 2024
Amount
Maintenance of DG set of any make, type, model as per set norms of the original manufacturer set and by the authorised rep of the company after unscrewing nut, bolts, screws etc. for servicing, maintenance, tigthtening, adjustment & cleaning of all moving and stationary parts of DG set, complete and segregating the parts for repair/ refixing/ replacing of capacity 15KVA , complete all as specified and directed. Make of DG sets :- kirloskar/Crompton Greaves/Ruston/Ashok Leyland /Cummins Note: The quoted rate includes the following: (a) Taking down of unserviceable parts. (b) Any minor repair, replacement of minor parts such as screws, gasket, nuts, bolts, washers, cleaning & greasing etc. of DG set parts. (c) Defective parts/ engine oil to be replaced will be measured & paid separately under supply only item as apended below.
All as per Serial Item No. 1 here-in-before but capacity 20 KVA For parameter light
All as per Serial Item No. 1 here-in-before but capacity 30 KVA
All as per Serial Item No 1 here-in-before but capacity 40 KVA
All as per Serial Item No. 1 here-in-before but capacity 63 KVA
Supply only under mentioned spare/parts suitable for the DG set complete all as specified and directed:-
Primary fuel filter element for DG set capacity 15KVA
Primary fuel filter element for DG set capacity 20KVA
Primary fuel filter element for DG set capacity 30KVA
Primary fuel filter element for DG set capacity 40KVA
Primary fuel filter element for DG set capacity 63KVA
Secondry fuel filter element for DG set capacity 15KVA
Secondry fuel filter element for DG set capacity 20KVA
Secondry fuel filter element for DG set capacity 30KVA
Secondry fuel filter element for DG set capacity 40KVA
Secondry fuel filter element for DG set capacity 63KVA
Air filter element for DG set capacity 15KVA
Air filter element for DG set capacity 20KVA
Air filter element for DG set capacity 30KVA
Air filter element for DG set capacity 40KVA
Air filter element for DG set capacity 63KVA
Oil filter element for DG set capacity 15KVA
Oil filter element for DG set capacity 20KVA
Oil filter element for DG set capacity 30KVA
Oil filter element for DG set capacity 40KVA
Oil filter element for DG set capacity 63KVA
Fuel and oil line complete for DG set capacity 15KVA
Fuel and oil line complete for DG set capacity 20KVA
Fuel and oil line complete for DG set capacity 30KVA
Fuel and oil line complete for DG set capacity 40KVA
Fuel and oil line complete for DG set capacity 63KVA
Water hose pipe set complete for DG set capacity 40KVA
Water hose pipe set complete for DG set capacity 63KVA
Material and labour for taking out radiator and repairing/brazing to make it leakage free, cleaning and re-fixing the radiator including testing for DG set capacity 15KVA to 40KVA, complete all as specified and directed.
All as per item No. 34 here-in-before but DG set capacity 63KVA complete all as specified and directed.
Supply and filling lubricant oil (Engine oil) SAE30 (Make as recommended by the manufacturer of DG set and as approved)
Supply, install, connecting and testing in replacement maintenance free batteries, 12 Volts, 180AH complete all as specified and directed.
Supply, install, connecting and testing in replacement maintenance free batteries, 12 Volts, 90 AH complete all as specified and directed.
Supply, install, connecting and testing in replacement maintenance free batteries, 12 Volts, 32AH, 2m copper leads -02 Nos & brass clamps complete all as specified and directed.
Supply and fix, battery lead not less than 1.5mtr long, made out of 50Sqmm copper cable with terminal of brass with marking (+)/(-) and fixing in position and testing, including taking down and removal, complete all as specified and directed.
Supply and filling, engine coolant in radiators of DG sets as per DG set manufacturer's recommendations at different locations, brought at site in sealed packets, complete all as specified and directed.
Maintenance, repair, servicing and calibration of automatic mains failure panel, DC & 415/440 volt AC supply operated system by locating faults and replacement of unserviceable parts and components for DG set 10KVA to 400KVA and testing on completion , complete all as specified and directed. Make of DG sets:- Kirloskar/Crompton Greaves/Sudhir/Ashok Leyland Note: The quoted rate includes the following: (a) Taking down of unserviceable parts. (b) Any minor repair, replacement of minor parts such as screws, gasket, nuts, bolts, washers, cleaning & greasing etc. of DG set parts. (c) Defective parts/ engine oil to be replaced will be measured & paid separately under supply only
Repair of faulty worn out control wiring DC/AC for engine starting and off, with adequate and suitable size copper conductor wire, connected with proper copper lugs & terminals through protection pipe/casing, complete all as specified and directed.
Repair of worn out/faulty internal wiring of controls and timers, indicating/measuring instruments through various control fuses and relays with suitable and adequate size of copper conductor wire, connected with suitable copper lugs and terminals, complete all as specified and directed.
Replacement of worn out small control fuses, indicating lamps, various type of copper lugs, thimbles terminals all as deemed necessary or directed including minor spare parts and components in order to make system serviceable and perfectly in working order , complete all as specified and directed.
Material and Labour for repairing battery charging dynoma including replacing worn out/unserviciable spares up to the capacity of 63 KVA all as specified and directed.
Material and Labour for repairing self starfer including replacing worn out/unserviciable spares up to the capacity of 63 KVA all as specified and directed.
Material and Labour for replacing the unserviciable AVR of DG sets up to the capacity of 63KVA and testing complete all as specified and directed.
Supply and Fix in repair, Power contractor 3 pole 63 Amps 415 volts operating coil , complete all as specified and directed.
Supply and Fix in repair, Power contractor 3 pole 100 Amps 415 volts operating coil , complete all as specified and directed.
Material and Labour for repairs to unserviceable street/security lights/Flood lights fittings of LED, of any wattage and size by taking down from poles any size/buildings after disconnecting the electric connection, replace the unserviceable drive ,PVC connector etc, cleaninng, refixing the light fittings at its original position after rectifying the defects and connecting to street light feeder including testing complete all as specified and directed. Note :- (i) Replacement of parts like drive , will be measured and paid seperatily as supply only (ii) The cost of labour ,tools and minor spares required for replacement of parts shall deem to include in the unit rate quoted by the contractor.
Taking down the existing light fittings multi mounting brackets from High Mast Pole/Structure (12 mtrs High) for repairs/replacing the defective parts and refixing the same in original position after carrying out necessary repair/replacement of parts i.e. unserviciable ignitor, ballast, capacitor from control gear box , complete all as specified and directed.
Supply and Fix PVC insulated stranded aluminium conductor, 1100 volts grade heavy duty cable of size 2.5Sqmm 2 core (from junction box to street light fitting mounted on steel tubular/PCC pole) including taking down existing unserviceable cable, complete all as specified and directed.
Supply and fixing electronic drive suitable for LED street light /Flood light of capcity up to 60W all as specified and and directed.
Supply and fixing electronic drive suitable for LED street light /Flood light of capcity up to 70W to 180 all as specified and and directed.
Supply and fixing Water pump for DG sets suitable upto to the capacity upto 63 KVA including diamantling and refixing the accessories of prime mover all as specified and directed.
Supply and Fix in replacement KIOSK box weather proof made out of PVC/HDPE fire retardent,non fusing,shock and rust proof, pole mounted, hinged door size minimum 300X200X100mm comprising of aluminum bus bar 4 strips for 3 phase and neutral 63 Amp with 6Amp MCB including clamps with necessary MS nuts bolts and washer complete all as specified and directed.
Material and Labour for taking out and reinstalling 1.5 hp electric motor for high mast after repair/rewinding of motor all as specified and directed.(Cost of taking motor upto workshop and repair deemed to include in the quoted rate)
Material and Labour for cleaning of diesel tank of DG set of any capacity including replacement of worn out pipe line and measuring scale and fixing in original position and make it leak proof with necessary clamps complete all as specified and directed.
Taking out FIP from DG set, of cap upto 63 transportation to authorised service centre for repair /maintenance and refixing to DG set including replacement of necessary spare parts such as Plunzers, governer kit with pin , Nozzels , Head ball guide kit, Head sheet , Rock rod, Rollar bearing , oil seal, piston & rings pin, jain kit and sleeves complete all as directed and specified.
Supply and fix in replacement of fully automatic battery charger suitable for 12V battery upto the capacity of 180AH having Ammeter and charge cut option complete all as specified and directed.
Supply and fix in replacement of LED street light fitting 60W AC 230V 50 Hz powder coated pressure die cast alluminum housing power LED with heat resistant toughned glass IP 66 complete all as specified and diredted. Make-Crompton Cat part Num-LSTP-60-CDL-M,or equivalent as per Appendix 'B' List of approved makes.
Supply and fix in replacement of LED flood light fitting 200W AC 230V 50 Hz powder coated pressure die cast alluminum housing power LED with heat resistant toughned glass IP 66 for high mast complete all as specified and directed. Make :Crompton LFLN-200-CDL-60/M OR equivalent as in APPENDIX ‘B’ List of approved makes.
Supply and fix in replacement of LED street light fitting 45W AC 230V 50 Hz powder coated pressure die cast alluminum housing power LED with heat resistant toughned glass IP 66 complete all as specified and directed. Make-Crompton cat part No-TRP-417-45-57-SL-LM-NBK or equivalent as per Appendix 'B' List of approved make.
Supply and fix in replacement of LED High Bay light fitting 70W AC 230V 50 Hz powder coated pressure die cast alluminum housing Circular LED Flood Light with tapered fin design and excellent thermal management along with IP66 protection. complete all as specified and directed. Make-Crompton cat part No-LFLN11-70-CDL/60 or equivalent as per Appendix B List of approved makes.
Supply and fix in replacement of LED flood light fitting 140W AC 230V 50 Hz powder coated pressure die cast alluminum housing Circular LED Flood Light with tapered fin design and excellent thermal management along with IP66 protection complete all as specified and directed. Make-Crompton cat part No-LFLN11-140-CDL/60 or equivalent as per Appendix B List of approved makes.
Supplying and fixing in repair On-load type Changeover switch 100A, 4-pole, 415 volt, open execution type complete all as specified and as directed. Make: L&T/Havells/BCH/Schneider
Supplying and fixing in repair On-load type Changeover switch 200 Amp, 4-pole, 415 volt, open execution type complete all as specified and as directed. Make: L&T/Havells/BCH/Schneider
Supply and fixing in replacement lubricant oil pump for DG sets suitable upto to the capacity upto 63 KVA including diamantling and refixing the accessories of prime mover all as specified and directed.
Demolition of concrete foundation and taking out existing pcc poles and removal of pole to store for reuse or credit and disposal of dibris outside MOD land, including disconnecting and taking down old street light fittings, complete all as specified and directed.
Supply and fixing/erecting in true vertical position ,Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31, 9 MTR Long complete all as specified and directed. Note: Earth work and pcc shall be measured and paid seperately.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for cement concrete (unreinforced) or road cutting complete all as specified and as directed.
Material and Labour for PCC 1:2:4 type B-1 using 20mm graded stone aggregate for coping incuding necessary form work, complete all as specified and directed.
Material and Labour for PCC 1:4:8 type D-2 using 40mm graded stone aggregate for foundation and mass concrete filling, complete all as specified and directed.
Dismantling and taking down ,cross arms of ms channel or angel channel or angle section ,including clamps bolt washers etc , and removal ,complete all as specified and directed.
Material and Labour for Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections Fe-290 grade E-165 quality including nuts, bolts, washers,welding, bending cold or hot,drilling holes for bolts, in any shape or size including two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
Material and labour, painting two coats of aluminium paint to steel tubular poles of any description (external surface only) including MS cross arms etc making of 5 strips of width 300mm each (03 Nos Sky blue and 2 No. white) writing pole No. with black paint with letters/figures in girth 3 inch, including preparation of old painted surface, complete all as specified and directed.
Material and Labour for replacing the unserviceaable Volatge monitoring relay of AMF panel of DG sets up to the capacity of 63KVA and testing complete all as specified and directed.
Taking out of alternator upto 30 kva KVA DG set of of any make at site 3 phase 415 volts 50 Hz from the existing position after disconnecting all electrical cable earthing and transportation to workshop,dismantling the alternator and rewinding the same with existing guage super enamelled copper wire of approved make varnishing the same and heating properly in heat chamber, re-assembling the alternator after replacement of ball bearing rusted nut and bolts and install the same to the existing position and apply 2 coat of synthetic enamel paints after successfully repairs and testing complete as specified and directed. Note:- (i) Contractor will provide labour, machinery , tools, crane, transportion required.(ii) All parts will be measured and paid separately under relevant items (iii) Fixing charges of parts/spares are incl in quoted rates.
Material for rewinding Copper wire for stator/field of existing gauge.
Supply only 'F' class insulation paper
Supply only 10 No size insulation sheet
Supply only Glass paper
Supply only Cotton tape
Supply only Varnish
Supply only main connection wire 50 sqmm copper single core
Supply only Copper thimble
Supply only Sleeve 'F' class
Supply only Ball bearing 6310
Supply only field insulation 'F' class
Supply only suitable diode assembly
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material (Epoxy Based) and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of size 16 to 50 sq mm complete all as specified and as directed.
Supply & Fix in repairs LED Post top lantern of 1X20 Watt with die cast aluminium spigot and lid cover, high efficient LEDs and clear acrylic cover IP-65, complete all as specified and directed. Make-Crompto LPTH-20-CDL or equivalent as in APPENDIX ‘B’ List of approved makes.
Material and Labour for detecting of fault in LT UG cable with fault locator equipment to locate the fault in LT cable of any length any size complete all as specified and directed. Note :- (a) The fault which is detected through cable fault locater will only be paid under this item (b) Charges of cable fault locator and DG set including transportation charges deemed to be included in the quoted rate. (c ) Earth fault locator will be provided by the contractor for even single fault and no dealy on this account will be acceptable otherwise penality will levied Rs 1000/- per day. (d) Necessary testing of cable after making joint will be deemed to be including in the cost of relevent item. However necessary earth work cable cutting , joint making Joint will be paid under relevant item.
Disconnecting & taking out defective underground cable from trenches, pole, pipe, floor, wall, under road etc and locate the fault manualy, rectify the defect and relaying cable including connecting and testing for any size complete all as specified and directed. Note: Excavation/earth work, joint and any other item shall be measured & paid separately under relevent item .
Making / drilling / boring hole under road / plinth for crossing electrical cables / pipes manualy or with the help of machine as per requirement complete all as specified and directed.
Taking out from trenches/floors/road/wall/pipe/pole LT cable of any size/description and removing from site incl making good the disturbed surfaces to match with existing surface complete all as specified and directed.
Relaying old serviceable bricks reused for cable protection complete all as specified and directed.
Supply and laying, connecting and testing XLPE underground cable insulated, and overall sheathed with aluminium conductor heavy duty 1100 volts grade 6 sqmm 2 core laid in trenches/ on poles/ road crossing or passing through existing/new pipe under road crossing, clamping on wall etc complete all as specified and directed. Note: (i) Earth work, removing, returning filling and pipe will be measured and paid separately. (ii) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways are incl in the quoted rates. (iii) All equipments , machinery or tools if required for laying electrical cable through new/existing pipes are provided by the contractor without any extra cost.
All as per Serial Item No. 99 here-in-before but 10 Sqmm 4 Core size
All as per Serial Item No. 99 here-in-before but 16 Sqmm 4 Core size
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in loose/soft soil and getting out for underground cable/erection of poles, stays , trench etc complete all as specified and as directed.
Material and Labour for sand cushioning for cable with river washed sand and punning to provide required cover as per SSR part I complete all as specified and as directed.
Supplying and laying bricks common burnt clay sub class 'B' old size for cable protection complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick layers complete all as specified and as directed.
Removal of excavated material n.exc 50 mtr away and depositing where directed at a level n.exc 1.5 mtr above from starting point complete all as specified and as directed.
Material and Labour for Caliberation of generator controller of DG set 20 KVA including complete wiring connection and making DG set fully functional complete all as specified and directed.
Note: The total amount shall subject to adjustment of credit of Rs 24109.00 for old Materials as per Schedule of Credit
J H CONSULTANTS (BID ID -3067752)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .