Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.0 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹20.0 L+₹3.8 L (23.2%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹20.9 L+₹4.7 L (28.7%)Rejected-Finance 365 B 10 HENRY COMPLEX MATHIYAS NAGAR KP ROAD NAGERCOIL KANNIYAKUMARI DISTRICT 629001 | KANNIYAKUMARI | TAMIL NADU | 629001 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹21.7 L+₹5.5 L (33.9%)Rejected-Finance SCHOOL LINE NEAR MINNIEBAY JUNCTION SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹22.9 L+₹6.7 L (41.1%)Rejected-Finance | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
25 Apr 2022, 6:00 pmClosed
Garrison Engineer Haddo
GARRISON ENGINEER HADDO Military Engineer Services Haddo Post Port Blair Andaman and Nicobar 744102
REPAIRS/ REPLACEMENT OF INTERNAL WIRING, DISTRIBUTION BOXES, CEILING AND EXHAUST FANS, GEYSERS, DEFECTIVE LIGHTS AND FITTINGS AND OTHER RELATED ITEMS IN COAST GUARD AREA UNDER GE HADDO, PORT BLAIR
2022_MES_516934_1
8626/GE/H/PB
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE Haddo Port Blair
Class E Category b (i)
9 documents required · 9 mandatory
₹500
GE Haddo
₹40,000
Yes
4 Jun 2022
6 Apr 2022
30 Apr 2022
6 Apr 2022
25 Apr 2022
20 Apr 2022
6 Apr 2022 - 13 Apr 2022
Amount
Taking down carefully old unserviceable aluminum/ copper point wiring (light, fan, socket or power) complete, including fittings & fixtures such as switches, ceiling roses, lamp holders, pendants, regulators sockets, light fittings, junction/terminal boxes etc; removing from site and making good disturbed surfaces of walls, floors etc., to match with existing surrounding surfaces complete all as specified and as directed.
Taking down existing unserviceable main switches/ distribution boards/Fuse Units of any description alongwith MCBs/MCCBs and making good disturbed surfaces to match with existing surrounding finishes complete all as specified and as directed.
Taking down carefully old unserviceable light fittings only and removing from site complete all as specified and as directed.
Taking down existing unserviceable sub main wiring of any description and making good disturbed surfaces to match with existing surrounding finishes complete all as specified and as directed.
M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC casing and capping of suitable size (not less than 25mm) and accessories fixed on walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in CI boxes/pressed steel terminal boxes 60mm deep made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint outside and with two coats of aluminium paint inside and laminated sheet cover of 3mm thick on top for housing the switches, socket outlet etc, all as specified and as directed for the following :-
ONE LIGHT/FAN point controlled by one, one way 6 Amps switch.
ONE 6A SOCKET OUTLET point controlled by one, one way 6 Amps switch on independent board.
ONE 6A SOCKET OUTLET point controlled by one, one way 6 Amps switch on same board.
ONE BELL point controlled by one, one way 6 Amps switch.
ONE 6A SOCKET OUTLET point controlled by one, one way 6 Amps switch on independent but below the switch board of light point with cable of 1.5Sqmm size.
M&L for Point wiring complete with 4 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC casing and capping of suitable size (not less than 25mm) and accessories fixed on walls/ceilings etc., including provision of PVC insulated 4 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in CI boxes/pressed steel terminal boxes 60mm deep made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint outside and with two coats of aluminium paint inside and laminated sheet cover of 3mm thick on top for housing the switches, socket outlet etc, all as specified and as directed for ONE 16A SOCKET OUTLET point controlled by one, one way 16 Amps switch on independent board.
S&F switch piano, flush type, single pole, one way, 6 Amps, 240 volts complete all as specified and as directed.
S&F switch piano, flush type, single pole, one way, 16 Amps, 240 volts complete all as specified and as directed.
S&F switch socket outlet, 5 pin, 6A, flush type, multipurpose, 240 volts complete all as specified and as directed.
S&F switch socket outlet, 2-in-1, 6 pin, 6A/16A, flush type, multipurpose, 240 volts complete all as specified and as directed.
S&F bell push, flush type, single pole, one way, 6 Amps, 240 volts complete all as specified and as directed.
M&L for ceiling rose, three terminal, 65x20mm size, PVC/Polycarbonate, insulated body, 6A, 240 volts complete all as specified and as directed.
S&F switch socket combination box type 2 in 1, 5 pin, 6 Amps, flush type,universal complete all as specified and as directed.
S&F switch socket combination box type 2 in 1, 6 pin, 6 Amps & 16 Amps, flush type,universal complete all as specified and as directed.
S&F electric bell, ding dong type, AC, 230 volts complete all as specified and as directed.
S&F electronic fan regulator for ceiling fan, step type, 5 speed, AC, 120 watts, 230 volts complete all as specified and as directed.
M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC casing and capping of suitable size (not less than 25mm) and accessories fixed on walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in modular type pressed steel terminal boxes of suitable modules made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint all over and modular cover plates with frames on top for suitable modules on top for housing switches, sockets etc., all as specified and as directed for the following:-
ONE LIGHT/FAN point controlled by one, one way 6 Amps modular switch.
TWO LIGHT points controlled by one, one way 6 Amps modular switch.
ONE BELL point controlled by one, one way 6 Amps modular switch.
ONE 6A SOCKET OUTLET point controlled by one, one way 6 Amps modular switch on independent board.
ONE 6A SOCKET OUTLET point controlled by one, one way 6 Amps modular switch on same board with other switches.
ONE 6A SOCKET OUTLET point controlled by one, one way 6 Amps switch on independent but below the switch board of light point with cable of 1.5Sqmm size.
M&L for Point wiring complete with 4 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC casing and capping of suitable size (not less than 25mm) and accessories fixed on walls/ceilings etc., including provision of PVC insulated 4 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in modular type pressed steel terminal boxes of suitable modules made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint all over and modular cover plates with frames on top for suitable modules on top for housing switches, sockets etc., all as specified and as directed for ONE 16A SOCKET OUTLET point controlled by one, one way 16 Amps modular switch on independent board.
S&F modular switch, one way, one module, single pole, 6 Amps, 240 Volts AC complete all as specified and as directed.
S&F modular switch, one way, one module, single pole, 16 Amps, 240 Volts AC complete all as specified and as directed.
S&F modular socket, multipurpose, 2/3 pin combined, 2 module, single pole, 6 Amps, 240 Volts AC complete all as specified and as directed.
S&F modular socket, multipurpose, 2/3 pin, 6/16 Amps combined, 2 module, single pole, 240 Volts ACcomplete all as specified and as directed.
S&F modular bell push, one way, one module, single pole, 6 Amps, 240 Volts AC complete all as specified and as directed.
S&F modular electronic fan regulator for ceiling fan, step type, 5 speed, AC, 2 module, 120 watts, 240 volts complete all as specified and as directed.
Taking down carefully ceiling fan of any sweep from ceiling hook at any height after disconnecting from electricity, dismantling blades, opening up for carrying out servicing/over hauling, examining for damaged worn out parts like shaft, ball bearings etc., and applying grease to bearings, assembling back, preparing painted surfaces by cleaning dust, grease etc., and by filling cavities with filler to receive spray paint using synthetic enamel paint of existing shade and writing MES No. in synthetic enamel paint, fixing up blades and hanging back in position and providing and connecting up with 1.0 sqmm twin core twisted flexible copper conductor of suitable length from connector of fan to ceiling rose and testing complete all as specified and as directed. NOTE: Spare parts like ball bearings, shafts, fan blades, copper winding shall be replaced only if found damaged and certified by Engineer-in-charge. If spares are replaced, they shall be measured and paid separately as SUPPLY ONLY. A book shall be maintained for record of servicing and replacement of spares with MES Nos. of fans.
Taking down carefully exhaust fan/ wall mounting fans of any sweep from its position at any height after disconnecting from electricity, dismantling blades, opening up for carrying out servicing/over hauling, examining for damaged worn out parts like shaft, ball bearings etc., and applying grease to bearings, assembling back, preparing painted surfaces by cleaning dust, grease etc., and by filling cavities with filler to receive spray paint using synthetic enamel paint of existing shade and writing MES No. in synthetic enamel paint, fixing up blades and fixing back in position and providing and connecting up with 1.0 sqmm twin core twisted flexible copper conductor of suitable length from connector of fan to ceiling rose and testing complete all as specified and as directed. NOTE: Spare parts like ball bearings, shafts, fan blades, copper winding shall be replaced only if found damaged and certified by Engineer-in-charge. If spares are replaced, they shall be measured and paid separately as SUPPLY ONLY. A book shall be maintained for record of servicing and replacement of spares with MES Nos. of fans.
Rewinding of ceiling fan (any sweep) stator by super enamelled copper winding wire of suitable gauge and size with Garware insulating paper, insulating varnish and oven drying for requisite insulation values including necessary PVC sleeves. lead wires and testing after assembling in position in ceiling fan complete all as specified and as directed.
Rewinding of exhaust fan by super enamelled copper winding wire of suitable gauge and size with Garware insulating paper, insulating varnish and oven drying for requisite insulation values including necessary PVC sleeves. lead wires and testing after assembling in position in exhaust fan complete all as specified and as directed.
Rewinding of wall mounted fan by super enamelled copper winding wire of suitable gauge and size with Garware insulating paper, insulating varnish and oven drying for requisite insulation values including necessary PVC sleeves. lead wires and testing after assembling in position in exhaust fan complete all as specified and as directed.
SUPPLY ONLY sealed ball bearing suitable for ceiling fan with bearing No. 6201/6202 complete all as specified and as directed.
SUPPLY ONLY shaft suitable for ceiling fan 1200mm/1400mm sweep complete all as specified and as directed.
S&F Ceiling fan blade set of 1200/1400mm sweep complete all as specified and as directed.
S&F exhaust fan blade set of 150/250/300/380mm sweep complete all as specified and as directed.
S&F wall mounted fan blade set of 300/400mm sweep complete all as specified and as directed.
Taking down carefully electric geysers of any make, type and capacity after disconnecting of electrical and water connections, opening of bottom cover, checking of all parts and taking out copper tank, checking of its leakage and removing the dust, brazing the leakage and painting of geysers with two coats of synthetic enamel paint, replacement of burnt out spares and assembling the geyser and re-fixing back in its original position complete all as specified and as directed. NOTE: Spares shall be measured and paid separately under relevant items as SUPPLY ONLY.
SUPPLY ONLY heating element 1500 watts.
SUPPLY ONLY thermostat switch.
SUPPLY ONLY pressure release valve.
SUPPLY ONLY thermal cut out.
SUPPLY ONLY indicator lamp RED/GREEN colour.
SUPPLY ONLY PVC connection 15mm size with PTMT nuts of length 600mm. MAKE: PRAYAG/ POLYTUFF
S&F Starter switch of capacity 25 Amps, working on 240 volts, AC supply, suitable for air conditioner complete all as specified and as directed. MAKE: Crabtree Cat part No. ACAO252504 or equivalent in ANCHOR/ L&T/ HAVELLS
M&L for Sub main wiring complete with four runs (3P+1N) of 10.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 10.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including 32mm wide rigid non-metallic PVC casing and capping and its accessories (OR) 25mm dia PVC conduit and conduit accessories fixed on surface of wall/ceiling/roof/ floor complete all as specified and as directed. NOTE: Four runs of 10.0 Sqm copper conductor, One run of 10.0 Sqmm copper conductor as earth wire and one run of PVC casing and capping / PVC conduit shall be measured as one unit length.
M&L for Sub main wiring complete with four runs (3P+1N) of 6.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 6.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including 32mm wide rigid non-metallic PVC casing and capping and its accessories (OR) 25mm dia PVC conduit and conduit accessories fixed on surface of wall/ceiling/roof/ floor complete all as specified and as directed. NOTE: Four runs of 6.0 Sqm copper conductor, One run of 6.0 Sqmm copper conductor as earth wire and one run of PVC casing and capping / PVC conduit shall be measured as one unit length.
M&L for Sub main wiring complete with two runs (1P+1N) of 6.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 6.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including 32mm wide rigid non-metallic PVC casing and capping and its accessories (OR) 25mm dia PVC conduit and conduit accessories fixed on surface of wall/ceiling/roof/ floor complete all as specified and as directed. NOTE: Two runs of 6.0 Sqm copper conductor, One run of 6.0 Sqmm copper conductor as earth wire and one run of PVC casing and capping / PVC conduit shall be measured as one unit length.
M&L for Sub main wiring complete with two runs (1P+1N) of 4.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 4.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including 32mm wide rigid non-metallic PVC casing and capping and its accessories (OR) 25mm dia PVC conduit and conduit accessories fixed on surface of wall/ceiling/roof/ floor complete all as specified and as directed. NOTE: Two runs of 4.0 Sqm copper conductor, One run of 4.0 Sqmm copper conductor as earth wire and one run of PVC casing and capping / PVC conduit shall be measured as one unit length.
M&L for Sub main wiring complete with two runs (1P+1N) of 2.5 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 2.5 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including 32mm wide rigid non-metallic PVC casing and capping and its accessories (OR) 25mm dia PVC conduit and conduit accessories fixed on surface of wall/ceiling/roof/ floor complete all as specified and as directed. NOTE: Two runs of 2.5 Sqm copper conductor, One run of 2.5 Sqmm copper conductor as earth wire and one run of PVC casing and capping / PVC conduit shall be measured as one unit length.
S&F MCB DB, TPN, 4-way, vertical type, double door, 415 Volts with 200 Amps rated bus bar, IP-43 protection, shrouded neutral bus bar, cement spill protector, concealed in wall and making good disturbed surfaces to match with surrounding surface complete including taking down old unserviceable DB of any type/rating all as specified and as directed. MAKE: INDO ASIAN Cat part No. 811870 or equivalent in L&T/ LEGRAND/ HAVELLS
S&F MCB DB, SPN, 12-way, vertical type, double door, 240 Volts with 200 Amps rated bus bar, IP-54 protection, shrouded neutral bus bar, cement spill protector, concealed in wall and making good disturbed surfaces to match with surrounding surface complete all as specified and as directed. MAKE: INDO ASIAN Cat part No. 811828 or equivalent in L&T/ LEGRAND/ HAVELLS
S&F MCB DB, SPN, 8-way, vertical type, double door, 240 Volts with 200 Amps rated bus bar, IP-54 protection, shrouded neutral bus bar, cement spill protector, concealed in wall and making good disturbed surfaces to match with surrounding surface complete all as specified and as directed. MAKE: INDO ASIAN Cat part No. 811826 or equivalent in L&T/ LEGRAND/ HAVELLS
S&F MCB DB, SPN, 4-way, vertical type, double door, 240 Volts, 50 Hz with 200 Amps rated bus bar, IP-54 protection, shrouded neutral bus bar, cement spill protector, concealed in wall and making good disturbed surfaces to match with surrounding surface complete all as specified and as directed. MAKE: INDO ASIAN Cat part No. 811824 or equivalent in L&T/ LEGRAND/ HAVELLS
S&F in repair MCCB, 4 pole, 125 Amps, 50Hz, 25KA rupturing capacity, 415 Volts adjustable type with thermal and magnetic release complete all as specified and as directed. MAKE: INDO ASIAN/ L&T/ LEGRAND/ HAVELLS
S&F MCCB, 3 pole, 100 Amps, 50Hz, 16KA rupturing capacity, 415 Volts adjustable type with thermal and magnetic release complete all as specified and as directed. MAKE: INDO ASIAN/ L&T/ LEGRAND/ HAVELLS
S&F MCB, TPN, "C" series, 415 volts, 63 Amps, 10 KA rupturing capacity complete all as specified and as directed. MAKE: INDO ASIAN Cat part No. 811220 or equivalent in L&T/ LEGRAND/ ABB/ HAVELLS
S&F MCB, TP, "C" series, 230 volts, 63 Amps, 10 KA rupturing capacity complete all as specified and as directed. MAKE: INDO ASIAN Cat part No. 811198 or equivalent in L&T/ LEGRAND/ ABB/ HAVELLS
S&F MCB, TP, "C" series, 230 volts, 40 Amps, 10 KA rupturing capacity complete all as specified and as directed. MAKE: INDO ASIAN Cat part No. 811196 or equivalent in L&T/ LEGRAND/ ABB/ HAVELLS
S&F MCB, DP, "C" series, 230 volts, 40 Amps, 10 KA rupturing capacity complete all as specified and as directed. MAKE: INDO ASIAN Cat part No. 811174 or equivalent in L&T/ LEGRAND/ ABB/ HAVELLS
S&F MCB, SP, "C" series, 240 volts, 6 to 32 Amps, 10 KA rupturing capacity complete all as specified and as directed. MAKE: INDO ASIAN Cat part No. 811122 to 811129 or equivalent in L&T/ LEGRAND/ ABB/ HAVELLS
S&F 18 Watts, 220 Volts surface mounted LED ceiling light fitting with high performance LED, slim square/round panel, made from die-cast aluminium and CRCA covering, powder coated in white colour. high efficiency PMMA diffuser complete all as specified and directed. MAKE: PHILIPS, Model: Star Surface/ CG Cat Part No: LCDSPLN-R-18-NW-WW or CG Cat No LCDSPLN-S-18-NW-WW or equivalent in HAVELLS/ LUKER NOTE: The rate quoted deemed to include for any alterations required to existing false ceiling as per site condition for fixing light fitting
S&F 18 Watts, 220 Volts recess mounting LED ceiling light fitting, round/square shaped, made from die-cast aluminium and CRCA covering, powder coated in white colour suitable for armstrong/grid ceiling complete with separate electronic driver complete all as specified and directed.. MAKE: PHILIPS, Model: Astra Max Metal Panel/ CG Cat Part No: CDR-206-18-57-SL-NWH or equivalent in HAVELLS/ LUKER NOTE: The rate quoted deemed to include for any alterations required to existing false ceiling as per site condition for fixing light fitting
S&F 15 Watts, 220 Volts recess mounting LED ceiling light fitting, round/square shaped, made from die-cast aluminium and CRCA covering, powder coated in white colour suitable for armstrong/grid ceiling complete with separate electronic driver complete all as specified and directed.. MAKE: PHILIPS, Model: Astra Max Metal Panel/ CG Cat Part No: CDR-205-15-57-SL-NWH or equivalent in HAVELLS/ LUKER NOTE: The rate quoted deemed to include for any alterations required to existing false ceiling as per site condition for fixing light fitting
S&F 12 Watts, 220 Volts recess mounting LED ceiling light fitting, size round/square shaped, made from die-cast aluminium and CRCA covering, powder coated in white colour suitable for armstrong/grid ceiling complete with separate electronic driver complete all as specified and directed.. MAKE: PHILIPS, Model: Astra Max Metal Panel/ CG Cat Part No: CDR-205-12-57-SL-NWH or equivalent in HAVELLS/ LUKER NOTE: The rate quoted deemed to include for any alterations required to existing false ceiling as per site condition for fixing light fitting
S&F LED lighting fixture, 20 Watts, 220 Volts , 50Hz with extruded aluminium heat sink, environmental friendly energy efficient fitting surface mounted including taking down old defective/rusted/burntout 28 Watts T-5 FTL fittings complete all as specified and as directed. MAKE: PHILIPS, Model: Astra Line 4ft or equivalent in HAVELLS/ CROMPTON GREAVES / LUKER
S&F LED lighting fixture, 10 Watts, 220 Volts , 50Hz with extruded aluminium heat sink, environmental friendly energy efficient fitting surface mounted complete all as specified and as directed. MAKE: PHILIPS, Model: Astra Line or equivalent in HAVELLS/ CROMPTON GREAVES / LUKER
S&F 30 Watts LED light, recess mounting luminaire with glare free uniform illumination having longer life and less maintenance, size 600mmx600mm, 25000 burning hours including all accessories and fixing arrangements for fixing the light fitting complete all as specified and as directed. MAKE: PHILIPS Cat part No. RC380BLED30S-6500-G5 L60 W60 PSU OD / CROMPTON GREAVES Cat Part LCTLRNE-30-F0-WW or equivalent in HAVELLS/LUKER
S&F Wall mounting decorative fixtures made up of metal & glass suitable for 9 Watts LED bulb with and including bulb complete all as specified and as directed. MAKE: PHILIPS Model: 34302 or equivalent in HAVELLS/ CROMPTON GREAVES
S&F 7 W LED Spot Light for low ceiling height application in round shape,pressure die-cast aluminium housing, spring loaded clipsfor easy mounting complete all as specified and as directed. MAKE: Havells Model NO: LHEEGEPBIEIW009 or Equivalent in Philips Model 7W COB PRO/ CG/ C&S
S&F LED flood light fittings of high power LED, IP 66 protection, toughened glass, 70 Watts capacity, 220 V, 50Hz, pressure die-cast aluminium housing and Class I protection including necessary brackets of suitable size, bolts, nuts and washers as required and connected by 3 core 2.5 Sqmm multistranded copper conductor of suitable length including taking down old unserviceable one complete all as specified and as directed. MAKE: PHILIPS Cart part No.BVP141 LED70 CW FG GR PSU or equivalent in CROMPTON GREAVES/ HAVELLS/ C&S
S&F 25 Watts LED security light fitting with aesthetically designed COB LED ensure efficient optics and uniform distribution of light, for street light application. Pressure die cast aluminium housing powder coated in graphite grey and toughened glass of IP 65, including necessary fixing arrangements as per site requirements class-1 of model : Freedom of make CG complete all as specified and as directed. MAKE: Luker Cat No: LST-24/ Philps Cat Part BPRO42LED 19 CW MR S1 PSU GR or C&S Cat part No. LTESSE25WLED/ CROMPTON GREAVES/HAVELLS
S&F LED Strip light, 60 LED per metre, 28watts with driver, 2400 Lumen, 5 metre length, dimension 8mm wide x 3mm thick, including all fixing arrangment as per site requirement complete all as specified and as directed. Make: Philips Model: Sky Pro (WW/CDL/NW)/ CG/ Havels
S&F capacitor 2.5mfd, 230 Volts for ceiling fans including taking out old unserviceable one complete all as specified and as directed. MAKE: CAPCO/UNIVERSAL/TIBCON/EPCOS
M&L for earthing complete with GI earth plate electrode of size 600mmx600mmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5m below normal ground level connected to 4mm dia GI earth wire as earth lead connected by means of bolts, nuts, washers and check nuts made out of galvanised iron or steel all as shown on electrical plate No. 3 of SSR Part-I connected to common earth dolly including testing on completion complete all as specified and directed. NOTES: 1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with TMT bars 8mm dia @ 100mm c/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II. 2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately.
S&F PVC insulated copper conductor cable of size 2.5Sqmm, 1100 Volts grade, Heavy Duty, served with inner sheathing (flexible) industrial cable complete all as specified.
S&F PVC insulated aluminium flat twin core cable of size 4.0Sqmm, 1100 Volts grade, Heavy Duty, weather proof complete all as specified.
S&F Step light 2watts including taking down old unserviceable light fitting complete all as specified and as directed Make: Philips Cat No: 30974 or equivalent in CG/ Havells/ Luker
Removing and refixing the following during Addn/ Altn/ modification of existing structure:-
Light fixture/ switch socket outlet of any type and any capacity
Ceiling Fan/ Exhaust Fan of any sweep
Split Air Conditioner of any capacity
LABOUR ONLY for repairing and rectification of faults in LED fittings of any model/ make/ rating by disconnecting the electrical connections and refixing the same, back in position after carrying out repairs by checking the electrical connections/ electronic drivers etc., and testing after making it fully serviceable by checking the condition of electronic driver and replacing only if required complete all as specified and as directed. Note: (i) Electronic drivers, holders, LED tubes if required to be replaced shall be measured and paid separately as under relevant items of this BOQ as SUPPLY ONLY
Supply only 9 Watts holder type LED lamp 230 Volts, 50Hz complete all as specified and as directed. MAKE: PHILIPS / C&S/ HAVELLS/ CROMPTON GREAVES
Supply only 7 Watts retrofit holder type LED lamp 230 Volts, 50Hz complete all as specified and as directed. MAKE: PHILIPS /C&S/ HAVELLS/ CROMPTON GREAVES
Supply only electronic drivers for 10 to 24 watt LED post top luminaire / LED light fittings operated at input AC voltage 85 to 265 Volts, 50Hz, output DC voltage 42 to 65 Volts, 300MA, P.F > 0.95 complete all as specified and as directed. MAKE: PHILIPS/ CROMPTON GREAVES/ BAJAJ
M&L for repairs to point wiring for light/fan/socket by cutting , removing and replacing the burnt/ unserviceable length of wire with new FRLS Cable with copper conductor of size 1.5/2.5Sqmm size as per site requirement, replacing the saddles and refixing the old loose/ hanging conduit/ casing caping complete all as specified and as directed. Note: Rate inclusive of FRLS cable and other minor accessories.
NOTES FOR ALL ITEMS ABOVE: (i) One Electrician and one helper shall be deputed daily to JE E/Ms office during office hours to ascertain the repairs to be carried out for lights under his AOR. (ii) Necessary arrangements for carrying out repairs shall be under taken by the contractor.
ISLAND SALES ENTERPRISES
M/s Power Engineering Co
A. R. ELECTRICALS
ICON AGENCIES
NAVJEEVAN ENTERPRISES
SKV Engineering
SMS Engineering Corporation
SRI HARSHITA ELECTRICALS
B.R. ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .