| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical Qualified in Technical Bid |
| 2 | Accepted-Technical BUILDING NO FLAT NO A 80 DDA SHED OKHLA INDUSTRIAL ESTATE PHASE 2 NEW DELHI OKHLA INDUSTRIAL ESTATE PHASE 2 NEW DELHI DELHI 110020 | SOUTH EAST DELHI | DELHI | 110020 | Accepted-Technical Qualified in Technical Bid |
| 3 | Rejected-Technical | Rejected-Technical Credentials not submitted as per e-NIT. Not fulfilling e-NIT Criteria |
| 4 | Rejected-Technical E 44 3 1ST FLOOR OKHLA INDUSTRIAL AREA PHASE II OKHLA PHASE II NEW DELHI DELHI 110020 | SOUTH EAST DELHI | DELHI | 110020 | Rejected-Technical Credentials not submitted as per e-NIT. Not fulfilling e-NIT Criteria |
Tender Value
₹1.5 Cr
EMD Value
₹4.4 L
Closing Date
16 Jun 2026, 6:00 pmClosed
SM (E-E)
JPNI Airport, Patna
Provision of Green Gas Aerosol Based Fire Suppression System Thermally Operated For Electrical Panels at Patna Airport
2026_AAI_278842_1
AAI/ER/PAT/SM (E-E)/e-NIT-20/26-27
Open Tender
Electrical Works
Item Rate
60 days
JPNI Airport
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
₹4.4 L
29 Jun 2026
27 May 2026
18 Jun 2026
27 May 2026
16 Jun 2026
27 May 2026
27 May 2026 - 4 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Design and SITC of UL Listed Environment Friendly EPA Approved Aerosol based Fire Suppression System consisting of Aerosol generator having aerosol mass of specific quantity that shall be thermally actuated by means of aluminium alloy / bulb thermal sensor complying to UL 33. The housing shall be constructed of stainless steel shell and shall be sealed with a non permeable membrane. Units shall have passed salt spray corrosion test as per UL2775 Standard and must comply BIS/ NABL/EN / UL Standard 2127 and are part of their listing. Aerosol generated shall be potassium based and shall have No ozone depletion potential and no global warming potential. Agent shall be listed by the US EPA under the SNAP program. Fixed Condensed Aerosol Systems per NFPA 2010. UL approved design density of the aerosol should be generalized by 100g/cu.mtr along with safety factor for Class A, B & C fires as per NFPA. The Aerosol generator should have self life of 15 years. Aerosol generator shall be supplied with Stainless steel Bracket & Thermal Sensor. | |||||
| 1.01 | 30 Gm. | 210 | No | - | - |
| 1.02 | 60 Gm. | 15 | No | - | - |
| 1.03 | 100 Gm. | 12 | No | - | - |
| 1.04 | 250 Gm. | 10 | No | - | - |
| 1.05 | 500 Gm. | 5 | No | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
DNIT.pdf
Tender Documents • 4.30 MB
BOQ_325727.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .