Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.2 LAccepted-AOC | ₹19.2 L Quoted ₹16.2 L | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹16.7 L+₹55,424.81 (3.43%)Rejected-Finance | ₹16.7 L+₹55,424.81 (3.43%) | L2 | Rejected-Finance L2 Bidder |
Tender Value
₹15.4 L
EMD Value
₹30,792
Closing Date
27 Jan 2026, 3:00 pmClosed
O/o The Executive Engineer, Div -I, Panaji
O/o The Executive Engineer, Div -I, Panaji
Work for installing strtlights from Crematorium in Ward No III to Laudade Cross in Ward No IV and near Nilesh Haldankar house in Ward No VII and Near Fatima D Souza house in Ward No II and from Anand Shiva Naik house to main road in Ward No V Neura
2026_ED_27280_1
EE/Div.I/Tender-1(Gen)/6272 dated 16/01/2026
Open Tender
Electrical Works
Percentage
90 days
V. P. Neura
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
₹30,792
24 Jul 2026
17 Jan 2026
28 Jan 2026
18 Jan 2026
27 Jan 2026
19 Jan 2026
Supply of RCC pole 9.00 mtr
Supply of RCC pole 7.5 mtr
Supply of RCC stud pole (7.5m)
Supply of HDGI 4 pin 'X' arm of 75 x 40 Channel
Supply of HDGI 'X' arm clamps for RCC Pole 7.5mtr L.A
Supply of HDGI 'X' arm clamps for RCC Pole 9.0mtr L.A
Supply of HDGI 'X' arm clamps for RCC Pole 9.0mtr S.A
Supply of Complete stay set for 7.5mtr pole
Supply of Complete stay set for 9mtr pole
Supply of AAC 'GNAT' conductor
Supply of LED light (erection charges per LED) 30w
Supply of HDGI streetlight clamps for 25mm pipe (Top/Bottom)
Supply of GI bent pipe 1m x 25mm
Supply of LT Pin insulators
Supply of GI Pin for LT Pin insulators
Supply of LT Shackle insulators
Supply of Metal parts for LT Shackle insulators
Supply of GI Nuts & bolts
Supply of earthing set complete
Supply of GI Pipe 100mm, Class B
Supply of HDGI street light clamps for 100mm pipe(Top/bottom) for cable protection from ground to junction box
Supply of Street Light Service Pillar made out of CRCA sheet with PU painted complete with 4 pole MCCB, 3 pole MCBs, TP Contactors, Electronic/Digital Cum mechanical dual Timer, Connectors etc, complete as per enclosed specifications and approved make.(Street light Pillar)
Supply of FRP junction box including 4 way porcelain connector, cable gland etc.
Supply of 2 x 3 core 1.5 sqmm PVC flexible wire from junction box to the fixture.
Supply of PVC insulated PVC sheathed with aluminium conductor of 1.1KV grade 4 core armoured cable directed by engineer in charge CABLE OF SIZE 25 sqmm
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in :All types of Ordinary rock including all types of laterite rock, blasting prohibited (0.9*0.45*550) a)All kinds of soil
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidatinAg each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge.(0.7*0.45*length of cable trench)
Supplying and filling in plinth under floors, trenches including watering ramming consolidating, dressing, complete.Sand (0.2*0.45*length of cable trench)
Supply of Underground cable protective cover as per specs. The concrete slab shall be machine made using semi dry concrete that is batched in a fully automatic PLC controlled concrete batching plant and cast in a fully automatic : Vibropress" machine with a high vibration frequency and hydraulic pressure of 4MT, The size of the slab shall be 480mm*250mm*50mm and the concrete grade shall be M30 adhring to IS 4561:2000 and shall have minimum crushing strength of 30 N/mm2(28 days strength ) when tested.
Rubble packing for work of laying under ground cable by open trench works at road crossing and road cutting
Erection of RCC pole 9.00 mtr
Erection of RCC pole 7.5 mtr
Erection of RCC stud pole (7.5m)
Erection of HDGI 4 pin 'X' arm of 75 x 40 Channel
Erection of HDGI 'X' arm clamps for RCC Pole 7.5mtr L.A
Erection of HDGI 'X' arm clamps for RCC Pole 9.0mtr L.A
Erection of HDGI 'X' arm clamps for RCC Pole 9.0mtr S.A
Erection of Complete stay set for 7.5mtr pole
Erection of Complete stay set for 9mtr pole
Erection, Testing & Commissioning of AAC 'GNAT' conductor
Erection, Testing & Commissioning of LED light (erection charges per LED) 30w
Erection of HDGI streetlight clamps for 25mm pipe (Top/Bottom)
Erection of GI bent pipe 1m x 25mm
Erection of LT Pin insulators
Erection of GI Pin for LT Pin insulators
Erection of LT Shackle insulators
Erection of Metal parts for LT Shackle insulators
Erection of GI Nuts & bolts
Erection, Testing and Commisioning of Earthing Set Complete
Erection of GI Pipe 100mm, Class B
Erection of HDGI street light clamps for 100mm pipe(Top/bottom) for cable protection from ground to junction box
Erection, Testing and Commisioning of of Street Light Service Pillar made out of CRCA sheet with PU painted complete with 4 pole MCCB, 3 pole MCBs, TP Contactors, Electronic/Digital Cum mechanical dual Timer, Connectors etc, complete as per enclosed specifications and approved make.(Street light Pillar)
Erection, Testing and Commisioning of FRP junction box including 4 way porcelain connector, cable gland etc.
Erection, Testing and Commisioning of 2 x 3 core 1.5 sqmm PVC flexible wire from junction box to the fixture.
Erection, Testing and Commisioning of PVC insulated PVC sheathed with aluminium conductor of 1.1KV grade 4 core armoured cable directed by engineer in charge CABLE OF SIZE 25 sqmm
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in :All types of Ordinary rock including all types of laterite rock, blasting prohibited (0.9*0.45*550) a)All kinds of soil
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidatinAg each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge.(0.7*0.45*length of cable trench)
Supplying and filling in plinth under floors, trenches including watering ramming consolidating, dressing, complete.Sand (0.2*0.45*length of cable trench)
Laying of Underground cable protective cover as per specs. The concrete slab shall be machine made using semi dry concrete that is batched in a fully automatic PLC controlled concrete batching plant and cast in a fully automatic : Vibropress" machine with a high vibration frequency and hydraulic pressure of 4MT, The size of the slab shall be 480mm*250mm*50mm and the concrete grade shall be M30 adhring to IS 4561:2000 and shall have minimum crushing strength of 30 N/mm2(28 days strength ) when tested.
Rubble packing for work of laying under ground cable by open trench works at road crossing and road cutting
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 14.10 MB
Tendernotice_2.pdf
PDF • 4.01 MB
Tendernotice_3.pdf
PDF • 0.07 MB
BOQ_27721.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .