Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.6 LAccepted-AOC 47 HUSENI LAKDA BAZAAR 242 BELLAIS ROAD MUMBAI 08 | MUMBAI | MUMBAI | MAHARASHTRA | 400008 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹54.4 L+₹6.0 L (12.5%)Rejected-Finance | L2 | Rejected-Finance Other than being lowest. | |
| 3 | L3₹59.7 L+₹11.3 L (23.4%)Rejected-Finance A 14 USHA SADAN NEAR POST OFFICE COLABA MUMBAI 05 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | L3 | Rejected-Finance Other than being lowest. | |
| 4 | L4₹70.7 L+₹22.3 L (46.2%)Rejected-Finance B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L4 | Rejected-Finance Other than being lowest. |
Tender Value
₹75 L
EMD Value
₹1.4 L
Closing Date
4 Sept 2024, 6:00 pmClosed
CWE (NW) Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
REPAIR MAINTENANCE OF CI DI PIPE LINES FLOW METERS INCLUDING MISC ITEMS AT RS AREA UNDER GE NW NAVY NAGAR COLABA MUMBAI
2024_MES_662638_1
8207/CWE (NW) Mumbai/E8
Open Tender
Civil Works
Item Rate
180 days
GE (NW) Navy Nagar
As per tender documents
7 documents required · 7 mandatory
₹1,000
Yes
GE (NW) Navy Nagar
₹1.4 L
Yes
CWE (NW) Mumbai
11 Nov 2024
28 Jun 2024
6 Sept 2024
28 Jun 2024
4 Sept 2024
18 Jul 2024
28 Jun 2024 - 11 Jul 2024
11 Jul 2024
Amount
Dismantling the existing damaged glow sign board complete from the entrance gate of Pump House and remove from site. Supply & installation Glow Sign board made out of PGI sheet 1 mm thick fixed with transparent PVC acrvlic sheet cover of thickness 2.5 mm, of colour as directed with letters and digits of approx size 25 x 10 CM (Appx 42 Nos) of colour as directed, fixed with and including 18 watts, 240 Volt LED tube light fitting with rods as required at site( @ 2 sqm per one LED fitting) connecting with existing electrical point using 2 core PVC insulated, 1.5 Sqmm PVC insulated and PVC sheathed stranded copper conductor cable of suitable length with switch, fixing the sign board on GI pole/building using necessary fixing arrangements viz clamps, nuts, bolts and washers and welding , excavation and PCC work all as specified and directed. Note :1. Size of sign board and colour will be decided by the department as per the site requirement. 2. GI Pole shall be used for fixing of sign shall only be measured and paid separately under relevant item of Sch 'A'. Remaining items are deemed to be inclusive in the item rate.
Supply & fixing in repair in Sluice valves flanged end, cast iron body, flanged and drilled and rising type Steel spindle with nut, long body, ISI Marked, class PN 1.6, conforming to IS 14846 of 2000 for following sizes in any position/location including all flange joint with rubber or fiber board gaskets, bolts, nuts, washers, welding etc complete including pumping out accumulated water all as specified and directed of following sizes :- Note :- For Additional manpower, welding, chipping, plastering and any other item required for replacement of the item including making good the disturbed surfaces are deemed to be including in the item rate and no extra payment will be claimed by the contractor to the work.
300mm bore
250mm bore
200 mm bore
150 mm bore
100 mm bore
Supply and fixing in repair CI swing type non return valve (ISI Marked) flanged end of following sizes as per IS: 5312 body, cover C-I IS: 210, PN-10 complete including replacement of nut bolts, cutting of pipe, welding complete all as specified and directed.
300 mm bore
200 mm bore
150 mm bore
100 mm bore
Supply and Laying in repair LT XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10sq. mm, 4 core. Note : 1. The cost of Al thimbles/lugs and cable gland etc is including in the quoted rate and no extra payment will be made for it.
Supply & fixing in repair looping box of size 130mm x 130mmx77mm weather proof IP66/67 including connector blocks four way having suitable size bolt to connect upto 6sqmm x 2 core cable two Nos with the help of suitable gland, thimble nuts, washers supports by flat aluminium clamps not less than 25 mm x 3mm with suitable size nuts, bolts and washers inside and outside looping box including fixing with electric pole and taking out old one of any type complete as directed.
Supply, install, commissiong in repair Mechanical Flowmeter of dia 150 mm, Power Supply : 80 - 300 V AC/DC Output : 4 - 20 mA DC, Line Size : DN150 Pressure Rating : 10 kg/cm2 Design of measuring sensor : Flange ANSI 150 Flange Material : Carbon Steel Sensor Lining : Hard Rubber, Electrode Material : SS 316L Earthing Rings : SS 316, Measuring Tube : SS 304 Coil Housing : Carbon Steel ,Protection Class : IP 65 Note :- Quoted rate includes cutting, welding, any modifications in line/valves, lead joints, GI nut bolts, CI/GI fittings and its fixing including earth work as required at site and no extra cost will be paid to the contractor including making good to the disturbed surfaces complete all as directed.
Supply and fixing in repair HDPE Pipe of size 50 mm bore, PN 10, PE 63 material, including jointing with collars/bends complete all as specified and directed.
Supply and fixing in repairs CI foot valve flanged end IS 4038 PN 0.6, ISI Maked, housing complete including replacement of nut bolts, cutting of pipe, welding complete all as specified and directed.
300 mm bore
200 mm bore
150 mm bore
100 mm bore
Excavating in trenches not exceeding 1.5 mtr wide not exceeding 1.5 mtr in depth and getting out in soft/loose soil all as specified.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms in any type of soil all as specified.
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15 cm thickness (below or above ground level) and debris out side MD land all as specified.
Material & labour cement concrete 1:2:4, type B-2 (using 40 mm graded stone aggregate) as in support of CI pipes, foundation and hardstanding finishing even and fair without using extra cement all as specified.
Removing excavated material exc 250m but n.exc 500m and depositing where directed all as specified.
Material & labour in repairs for CI/DI specials conforming to IS - 1538& 9523, spigot /socket or flanged fitting I.e. bend, tee, collar, flanged/ socket /spigot, tappers, flanges and tail pieces etc suitable for 100/150/200/250/300 mm bore CI/DI pipes (joints and joining material shall be measured and paid seperately)
Material & labour in repairs for run lead joint in repair with pig lead including pumping out / bail out water and necessary excavation and earth work in any type of soil, to repair the joints for following sizes of pipes :-
300 mm bore
250 mm bore
200 mm bore
150 mm bore
100 mm bore
Material & labour for Cutting existing cast iron/DI pipes and reducing for insertion of CI/DI fittings to required length in position for following sizes :- Note :- Pipe fittings used shall be measured and paid under relevant items of schedule 'A' remaining items like welding and other items required shall be deemed to be included in the item rate
300 mm bore
250 mm bore
200 mm bore
150 mm bore
100 mm bore
Supply and fixing in repair Cast iron pipes with spigot and socket ends centrifugally cast class LA, in any length, laid in trenches, on ground, including clamping, welding of the following sizes complete all as specified and directed :-
300mm bore
250 mm bore
200mm bore
150mm bore
100mm bore
80mm bore
Supply and fixing in repairs ERW MS pipe, Medium grade, ISI marked for suction and deliver for pump including painting of one coat red oxide primer and two coats of synthetic enamel paint after fixing, welding and providing necessary PCC support as required at site complete all as specfied and directed by Engineer-in-charge of following sizes :-
150 mm dia
100mm dia
80mm dia
Supply & Fixing in repair/replacement of steel water tubing, galvanised, Medium grade with all fittings in shafts such as nipple, union, socket, elbow, bends, fixed to wall including necessary & capacity up to 15 th floor in high rise buildings in short piece/length, including breaking the existing brick wall for replacement of corroded GI pipe in/on wall and making good the disturbed surfaces complete all as specified and directed by Engineer-in-charge.Note (1)Work to be carried out in high rise buildings plain wall or in shafts or in terraces or inside the flats for cutting the existing GI pipe line and replace the same with new GI pipe in short piece or full length.
25 mm bore
40 mm bore
50 mm bore
80 mm bore
100 mm bore
Supply and laying in replacement of spigot and socket ductile iron water tubing, class K-9, cement mortar lining on inner surface and one coat of bituminous paint over exposed surface ISI marked, IS No. 8329: 2000, including rubber joint of suitable size laid on roof/floor/trenches, cutting, jointing of colar/flange, welding (if required) with proper alignment as per site requirement and carryout testing against leakage before filling the trenches etc complete all as specified and directed.
300mm bore
200mm bore
150mm bore
100mm bore
80mm bore
Attending the water supply breakdowns of any size/type of pipes in any position/location/depth including necessary excavation, earth work, cutting of pipes, welding, replacement of pipes of any nature, flanges, bends, collars, nut bolts, gasket, run lead joint or any other items required for rectification of break downs, testing and making good to the disturbed surfaces after rectification complete all as specified and directed for the following size of pipe lines :- Note :- 1. Items like run lead joint, CI/DI /MS fittings or pipes, nut bolts shall be measured and paid separately under relevant item of schedule 'A 2. Remaining items are shall be deemed to be included in the item rate and no extra payment shall not to be claimed for the completion of break down. 3. After hand over of complaint, contractor shall complete the break down within 24 hrs or other wise panel recovery shall be made 2500/- per breakdown
300/250 mm dia CI/DI/MS pipe line
150 mm dia CI/DI/MS pipe line
50/80/100 mm dia CI/DI/MS/GI pipe line
Opening of valve chambers, cleaning of grass/earthing materiale inside and perimeter of the chamber, servicing of valves, replacement of gland packings, re-fixing of gate of valve in proper position , painting of valves, chamber covers, repairing of hinges complete all as specified and directed
Supply, installation, testing in repair of Pressure relief valve (ISI Marked) of 150mm following specifications Design - Pilot Operated, Globe type MOC Body & Cover - Ductile Iron MOC Trim - SS 304 / ASTM A 351 GR. CF8 MOC Spring - SS 304 MOC - Diaphragm - Nylon Reinforced Nitrile Set Pressure - 55 to 75 Psi-g Temp .- Ambient Application - Water Ends Connection - Flange end as per ASME including excavation , cutting existing 150mm pipe all as specfied and directed by Engineer-in-charge.
Supply, installation,testing in repair of Pressure relief valve of 80mm (ISI Marked) following specifications Design - Pilot Operated, Globe type MOC Body & Cover - Ductile Iron MOC Trim - SS 304 / ASTM A 351 GR. CF8 MOC Spring - SS 304 MOC - Diaphragm - Nylon Reinforced Nitrile Set Pressure - 55 to 75 Psi-g Temp .- Ambient Application - Water, Ends Connection - Flange end as per ASME including excavation , cutting existing 150mm pipe all as specfied and directed by Engineer-in-charge.
Material & labour for cleaning and sterilization of inside surface of RCC/ Steel Underground/semi underground/Over head/Sedmentation/clear water sumps of capacity UG sump reservoir 250000 gallons capacity using seven stage water tank sterilization as under :- (a). First Stage : Drain out the water by using exit valve or high capacity dewatering system. (b). Second stage : Cleaning all the algae formation inside the tank by using TERBAC G10/ Inoxi-60/NB-69 a laboratory tested branded chemical (Test certificate of TERBAC-65/INOXI-60/NB -69 from Govt laboratory mentioning suitability for sterilization should be submitted before sterilization) and scrubbing the walls of the tanks. (c). Third strage : Fresh water cleaning by high speed jet pump. (d). Fourth stage: First bacteria screening is sterilization by using TERBAC-G5/ Inohor-5/NB-10 brannded halogen compound (Test certificate of TERBAC-65 Inohor -51 /NB?10 from Govt laboratory mentioning suitability for sterilization should be submitted before sterilization). (e). Fifth stage: Cleaning the floor of water tank by industrial vaccum cleaner. (f) . Sixth stage :Second bacteria screening and sterilizing by using ultra violet ray ejector covering 360 degree within the tank for killing all suspended bacteria. 2.00 Each Job 150000.00 1.02 (g) Seventh stage : Cleaning and third bacteria screening to sterilize the floor of the water tank using TERBAC G-65 (Test certificate of TERBAC-65 from Govt laboratory mentioning suitability for sterilization should be submitted before sterilization) complete all as specified & durected. NOTE :- The quoted rate is deemed to include for the following :- (i) All cleaning staff shall wear safety helmets, gumboots, safety belts when entering the tanks. (ii) Safety beltsshall be invariabily worn during climbing of stage mounted tanks & getting down in UG sump. (iii) Safety googels shall be worn during spraying of TERBAC-65 & G-65 1.03
All as per item No. 25.00 above but UG sump reservior 200000 gallons capacity
All as per item No. 25.00 above but UG sump reservior 90000 gallons capacity
All as per item No. 25.00 above but UG sump reservior 45000 gallons capacity
All as per item No. 25.00 above but UG sump reservior 25000 gallons capacity
Material & labour for cleaning and sterilization of inside surface of Over headrotational moulded water storage tank 5000 ltrs capacity using seven stage water tank sterilization as under :- (a). First Stage : Drain out the water by using exit valve or high capacity dewatering system. (b). Second stage : Cleaning all the algae formation inside the tank by using TERBAC G10/ Inoxi-60/NB-69 a laboratory tested branded chemical (Test certificate of TERBAC-65/INOXI-60/NB -69 from Govt laboratory mentioning suitability for sterilization should be submitted before sterilization) and scrubbing the walls of the tanks. (c). Third strage : Fresh water cleaning by high speed jet pump. (d). Fourth stage: First bacteria screening is sterilization by using TERBAC-G5/ Inohor-5/NB-10 brannded halogen compound (Test certificate of TERBAC-65 Inohor -51 /NB?10 from Govt laboratory mentioning suitability for sterilization should be submitted before sterilization). (e). Fifth stage: Cleaning the floor of water tank by industrial vaccum cleaner. (f) . Sixth stage :Second bacteria screening and sterilizing by using ultra violet ray ejector covering 360 degree within the tank for killing all suspended bacteria. 2.00 Each Job 150000.00 1.02 (g) Seventh stage : Cleaning and third bacteria screening to sterilize the floor of the water tank using TERBAC G-65 (Test certificate of TERBAC-65 from Govt laboratory mentioning suitability for sterilization should be submitted before sterilization) complete all as specified & durected. NOTE :- The quoted rate is deemed to include for the following :- (i) All cleaning staff shall wear safety helmets, gumboots, safety belts when entering the tanks. (ii) Safety beltsshall be invariabily worn during climbing of stage mounted tanks & getting down in water storage. (iii) Safety googels shall be worn during spraying of TERBAC-65 & G-65 1.03
All as above but capacity 2000Ltrs
S&F in repair Rotational moulded multylayer ( minimum three layer) polyethylene water storage tank confirming to IS12701(1996) hoisting and fixing in position at any location removing existing distmantling RCC/PCC OHT and including making new foundation as well as disconnecting all incoming & out going connection, provision of new tank fittings & connecting it at existing position up to 50 mm GI Pipe connection with nipple, union etc complete all as specified and directed.
5000 Ltr capacity
3000 Ltr capacity
2000 Ltr capacity
1000 Ltr Capacity
Material & labour for Construction of brick masonery valve chamber in repair of size 1.2 x 1.2 x 1.2 M (internal dimension) (above GL 0.30 mtr) suitable for fixing of sluice valves, 15cm thick foundation using PCC 1:4:8 type D-2 over 15cm thick hardcore of broken stone, 23cm thick brick walls built in cement and sand mortar 1:4, 15mm thick internal and external plaster including top of floor in cement and sand mortar 1:3, 15mm thick, finished even and smooth, without using extra cement, 5 mm thick plate cover on 70mm x 70mm x 10 mm MS angle frame embeded in PCC 1:2:4 type B-1coping, having rectangular, hinged, opening of size 150 x 100mm with locking arrangements ,hold fasts, etc, applying one coat of red oxide primer and two coats of synthetic enamel paint to all steel surfaces and earth work in any type of soil including disposal of debris outside MD land complete all as specified.
Supply and fixing in repairs in existing line, gun metal gate valve (ISI Marked) with iron wheel head screwed both ends for iron pipe including fittings i.e. union, socket etc complete all as specified of following sizes :-
25 mm bore
40 mm bore
50 mm bore
80 mm bore
shubham construction (BID ID -3071536)
S S ENTERPRISES (BID ID -3069697)
SHRI SAI ENTERPRISES (BID ID -3076526)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .