Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.8 LAccepted-AOC GYAMDU HOUSE OLD ROAD SHANAM LEH LADAKH UT 194101 | LEH LADAKH | LEH | LADAKH | 194101 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹53.3 L+₹5.5 L (11.6%)Rejected-AOC AIRPORT ROAD SKALZANGLING LEH LADAKH 194101 | LEH LADAKH | LADAKH | 194101 | L2 | Rejected-AOC R |
Tender Value
₹51.2 L
EMD Value
₹1.0 L
Closing Date
22 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) LEH
CWE(AF) Leh
PROVN OF EXTERNAL SERVICES FOR FUEL TANK AT AF STATION LEH
2023_MES_592848_2
81163/E8
Open Tender
Civil Works - Others
Item Rate
180 days
GE (AF) LEH
As per Tender documents
7 documents required · 7 mandatory
₹1,000
GE (AF) LEH
₹1.0 L
Yes
30 Jun 2023
24 May 2023
24 Jun 2023
24 May 2023
22 Jun 2023
31 May 2023
Amount
B/R works Rough excavation not exceeding 1.5m in depth and getting out in soft/loose of soil, complete all as specified and directed.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth and not exceeding 10Sqm on plan and getting out in hard/dense soil, trimming sides, leveling bottom, watering and well ramming bottom, complete all as specified and directed.
Excavation in trenches in hard/dense of soil not exceeding 1.5 metre wide and depth exceeding 1.5 metre but not exceeding 3.0 metre deep for laying of cables and foundation of poles etc. and getting out, complete all as specified and directed.
Returning, filling in trenches (soil), including spreading, leveling and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed.
Removal of surplus excavated soil to a distance exceeding 1.5Km but not exceeding 5.00Km and depositing where directed at a level not exceeding 1.5metre above the starting point, complete all as specified and directed.
Removal of surplus excavated soil to a distance not exceeding 50metre and depositing where directed at a level not exceeding 1.5metre above the starting point, complete all as specified and directed.
Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n exc. 1.5 m high from base, complete all as specified and directed.
Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., hight from base exc 1.5m but n exc. 3.0 m, complete all as specified and directed.
Rolling and consolidating formation surfaces of roads/berms in cutting, with power road roller 8 to 12 tonne capacity or any other approved compactor where rolling by road roller is not feasible, to achieve 98% PROCTER DENSITY to required level, gradient, slope, camber and super elevation including watering as necessary and filling in hollows and depressions which may occure during the process of rolling with and including approved earth, complete all as specified and directed.
Material & labour 150 mm thick (compacted thickness) granular sub base course(GSB), grading as per grade v as specified Table 400-1 of MORTH specifications for Road and Bridge works, 2013, in a single layer over compacted subgrade with natural sand, crushed gravel, crushed stone, crushed slag or combination there of as per the grading required. The materials are mechanically mixed, spread and leveling on the subgrade by using motor grader of adequate capacity and rolling with vibratory roller of capacity 80-100 KN static weight for achieving required compaction density of atleast 98% of the Maximum Dry Density. Consolidating to required gradient and camber complete all as spceified and directed with finished surface tolerances as per Table 900. 1 of MORTH specifications for Road and Bridge works, 2013.
Material & labour 150mm thick (compacted thickness) Water Bound Macadam (WBM), laid in two layers each of 75mm thick, produced using mixing plant over prepared granular sub base with aggregates of grading as per MORTH specifications, including spreading with mechanical paver, rolling and consolidated to required gradient and camber with 8 to 12 tonne vibratory/ power roller complete all as specified and as directed. Note: Each layer shall be provided in seperate operation.
Material and labour, Preparation of un-surfaced water bound macadam surface by brushing with wire brushes for removing caked mud etc , sweeping with brooms and finally fanning the cleaned surfaces with mechanical air compressor to remove all loose dirts and applying evenly a priming/tack coat with paving bitumen of VG-10 @ 10kg/10 Sqm complete all as specified and directed.
Material and labour Premix Bituminous concrete 40 mm consolidated thickness with 5.4% binder (paving bitumen of grade VG-10) content by weight of total mix and crushed aggregates of grading 2 with mix of aggregate and VG-10 bitumen in electronic operated 100-120 TPH batch type hot mix plant, transporting the hotmix from HMP to work site by tippers and laying with hydrostatic paver finisher and as per approved mix and rolled and compacted to required camber and gradient with 8-12 tonne smooth wheeled, vibratory and tandam roller, complete all as per clause 507 MORTH (5th Rev) specification and as specified and directed. Notes:- (i) The contractor shall quotes the rate against item considering 5.5% VG-10 bitumen content. Job mix formula as per Clause No. 505.3.3 of MORTH (5th Rev) for BC shall be worked out from Thapar Insti. of Engg & Tech. Patiala/ NIT Kurukshetra/ PEC Chandigarh/ CTL for obtaining Optimum Binder content (OBC) by the contractor without any financial effect to the Deptt and same be submitted to the GE for approval. Any variation in binder content on minus side shall be adjusted @ Rs 42/Kg of binder and no adjustment shall be made on plus side. (ii) Cost of filler i.e. cement (Ordinary portland cement/ OPC) is deemed to be included in quoted unit rate. (iii) After spreading of mix as per clause 505.4.7 entire surface during the operation shall be rolled with road roller 8-10 tonne (smooth wheeled) followed with vibratory road roller of 8-10 tonne static weight, followed by finished rolling with 6 to 8 tonne smooth wheel tendom roller as per clause nos. 507.4.8 and cost of the same is deemed to be included in quoted unit rate.
E/M works Supply and fix, 40mm bore Steel water tubing medium grade galvanised ( ISI marked) with all fittings( such as bends elbows, Tee, short pieces, connectors back nuts, diminishing pieces, caps and plug, unions etc), complete all as specified and directed.
Supply and fix, 25mm bore Steel water tubing medium grade galvanised ( ISI marked) with all fittings( such as bends elbows, Tee, short pieces, connectors back nuts, diminishing pieces, caps and plug, unions etc), complete all as specified and directed.
Supply and fix gun metal, gate valves of 25mm dia , with iron wheel head, screwed both ends for GI pipecomplete all as specified and directed.
Supply and fix gun metal, gate valves of 40mm dia , with iron wheel head, screwed both ends for GI pipecomplete all as specified and directed.
Material and Labour for PUF Insulated cylindrical double layer water storage tank of capacity 1000 Ltr along with hinged top lid of same material with locking arrangement with following specifications: (a) Inner tank will be double layered HDPE tank of relevant IS specification. (b) Outer 5mm thick FRP joint less casing. (c) Outlet to be fixed at the time of casting of tank. (d) Thickness of PUF insulation -75mm (e) Minimum density of PUF Insulation - 40kg/m³ ± 2 kg/m³ (f) Resin of relevant IS specification to be used.
Material and labour for construction of valve chamber of size 600x 600x 600mm deep dimensions (Over all internal dimension) with PCC foundation, block masonry walls, Plastering, PCC Coping, white washing, mild steel chamber cover, painting to chamber cover including Excavation and earth work in any type of soil complete all as specified below:-Valve chamber shall be provided with the following specifications:- (i) Cement concrete for foundation (1:4:8) type D2 using 40mm graded stone aggregate 150 mm thick extended up to 150 mm beyond the outer face of stone masonry.(ii) Walls of valve chamber 230 mm thick with precast cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregate) using block masonary setting in CM 1:4 complete. (iii) Internal and exposed surfaces of valve chamber both concrete and block masonry surface shall be plastered with CM (1:4), 15 mm thick finished even and smooth and three coats of white wash on exposed plastered/coping surface.(iv) 50 mm thick coping in PCC 1:3:6 type C1 over block masonry wall.(v) Chamber cover shall be of 6 mm thick MS sheet with 40 x 40 x 6 mm size angle iron frame with hold fast and locking arrangement. Steel surface shall be painted with two coats of synthetic paint of first quality over one coat of red oxide primer complete all as specified and directed.
Material and Labour for structural steel/tubular/box section , MS angle of 75x75x6mm iron staging and 2.5mm thick MS plate at top suitable for 1000 Ltrs capacity water tank, including all lattice bars,stiffeners, gusset plates, etc,including two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Material and labour,for providing Tee of size 50mm x 50mm x 40mm including cutting/tapping/screwing of existing pipe of 50mm dia and making connection of , complete all as specified and directed.
Material and labour, sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment.
Supplying and laying, factory made unreinforced precast concrete cable cover HV type-1, flat, of size 300x180x40mm, laid flat and dry in trenches over the cable for protection, length perpendicular to the direction of cable adjacent to each other,, complete all as specified and directed.
Supplying and laying, factory made unreinforced precast concrete cable cover LV type-1, flat, of size 250x150x40mm, laid flat and dry in trenches over the cable for protection, length perpendicular to the direction of cable adjacent to each other, , complete all as specified and directed.
Supply, laying jointing and testing, XLPE insulated screened PVC bedded, galvanized steel strip or wire electric power cable (heavy duty) suitable for earthed system with Stranded compacted circular Aluminium (H4 Grade) Conductor shielded with black extruded semimiconducting compound XLPE insulated, core shielded with back extruded semiconducting compound, copper tape, coloured strips having Red, Yellow & Blue for core indentification, single layer of round galvanized steel strip armoured and black extruded PVC (Type ST-2), overall sheathed, conforming gererally to IS 7098(Part-II)1985 and its latest amendments of size 6.35/11KV(E) volts grade cross sectional area 95 Sqmm, 3 core laid in trenches/ducts/pipes etc, complete all as specified and as directed. Note(s): (i) Returning filling earth work, sand cushioning and PCC cover for protection of cable shall be measured and paid separately.
Supply, laying jointing and testing, fixing to wall using clamps/pole/floor or in air or passing through pipes/ducts/road/path/drain laid in trenches, 1100 volts grade heavy duty electric cable XLPE insulated, screened, PVC bendded, galvanised steel wire or armoured with electric power cable 1100 volts grade with stranded aluminium conductor of size 3.5 core 70 sqmm confirming to IS-7098 Part-1 and its latest amendments complete all as specified and as directed by Engr-in-Charge. Note(s): (i) Returning filling earth work, sand cushioning and PCC cover for protection of cable shall be measured and paid separately.
Supply, laying jointing and testing, fixing to wall using clamps/pole/floor or in air or passing through pipes/ducts/road/path/drain laid in trenches, 1100 volts grade heavy duty electric cable XLPE insulated, screened, PVC bendded, galvanised steel wire or armoured with electric power cable 1100 volts grade with stranded aluminium conductor of size 2.0 core 10 sqmm confirming to IS-7098 Part-1 and its latest amendments complete all as specified and as directed by Engr-in-Charge. Note(s): (i) Returning filling earth work, sand cushioning and PCC cover for protection of cable shall be measured and paid separately.
Material and labour for Anti climbing devices comprising 2.24mm dia galvanised steel 2-strand barbed wire with 2.00mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 metre clamped and properly secured or as ordered (clamps measured separately), complete all as specified and directed.
Supply and fixing, danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size or as directed for HT, 25x20 cm size , complete all as specified and directed.
Material and labour for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrinkeable joint type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 sqmm, complete all as specified and directed.
Material and labour for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrinkeable joint type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 sqmm, complete all as specified and directed.
Supply and fix, GI pipe light grade 100mm dia as protection to cable along the pole/across road crossing/through ceiling/walls with necessary clamps-02 Nos (Flat iron 50x6mm) with nuts and bolts complete all as specified and as directed. Note : Excavation & earth work as required will be measured and paid separately.
Supply and fix, GI pipe light grade 80mm dia as protection to cable along the pole/across road crossing/through ceiling/walls with necessary clamps-02 Nos (Flat iron 50x6mm) with nuts and bolts complete all as specified and as directed. Note : Excavation & earth work as required will be measured and paid separately.
Supplying and erecting in verticle or to be planted as strut, steel tubular swaged welded poles complete with MS base plate 6mm thick of size 300mmx300mm at the centre of the pole, type 410 SP -55 (11 metres long) including drilling of holes of required size and nuts for fixing of cross arms, painting with coat of red oxide zink chrome primer and two coats of aluminium paint on exposed surfaces and two coats of black bituminous paint for portion embedded in concrete painting three white bands and lower portion of pole each of 300mm height at 300mm spacing completeall as specified and directed. (Excavation, earth work, foundation concrete and coping etc will be measured and paid separately).
Supplying and erecting in verticle or to be planted as strut, steel tubular swaged welded poles complete with MS base plate 6mm thick of size 300mmx300mm at the centre of the pole, type 410 SP -31 (9 metres long) including drilling of holes of required size and nuts for fixing of cross arms, painting with coat of red oxide zink chrome primer and two coats of aluminium paint on exposed surfaces and two coats of black bituminous paint for portion embedded in concrete painting three white bands and lower portion of pole each of 300mm height at 300mm spacing completeall as specified and directed. (Excavation, earth work, foundation concrete and coping etc will be measured and paid separately).
Material and labour, Cross arms, bracing, supports, clamps and back plates, fabricated from structural steel section Fe-290 grade E-165 quality including nuts, bolts, washers, and welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of alminium paint over a coat of red oxide primer, complete all as specified and directed.
Supplying and fixing Stay assembly set complete using 230x230x6mm thick, stay plate and 16mm dia rod 180 cm long with all accessories as shown in electrical plate No.1 (Loop type insulator stay clamps, excavation and concrete measured seperately. complete all as specified and directed.
Supplying and fixing Galvanized strand 7/4mm. complete all as specified and directed.
Supplying and fixing loop type insulator, vitreous porcelain, white, or brown or green large size with overall dimensions 140mm, clearance of hole 25.5mm. complete all as specified and directed.
Material and labour, Plain Cement Concrete (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete, complete all as specified and directed.
Material and labour, Plain Cement Concrete (1:3:6) type C-2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete, complete all as specified and directed.
Material and labour, PCC (1:2:4) type B-1, using 20mm graded crushed stone aggregate, as in coping to parapet walls, electric poles etc., weathering slightly, rounded or chamfered including use waste and necessary form work , complete all as specified and directed.
Supply and fixing switch air break operated triple pole structure mechanically operated from ground level mounted on and including 12 Nos insulators and steel frame outdoor type suitable for vertical installation single break fixed contact made of electrolytic copper strip duly electro silver plated with 8 micron thickness and moving contact made of hard-drawn electrolytic copper rod flexible jumper flexible branded tape woven with line tinned copper wire fixed and moving acrcing horn treminal conductor locking arrangement consisting of MS channel HT post type insulator copper alloy high pressure assembly with drop out fuse assmbly and operating rod of 25mm dia medium grade GI pipe complete confirming to IS1018 of 1972 with continous current rating up to 200 amps and voltage 11KV including testing and commissioning, complete all as specified and directed.
Supply and fixing expulsion type fuse single for 11 KV line of capacity 25 Amp , complete all as specified and directed.
Supply, fixing, commissioning and testing lightening arrester expulsion type with all fittings, 65 Kilo ampere discharge cap suitable for 11 KV line discharge class-II, 9KA, 50Hz transmission class conforming to IS-3070 Part-I-1985 for HT 11KV shall consists of multiple spark gaps in series with one or more non linear resistor limit , complete all as specified and directed.
Material and Labour for pin type, porcelain, vitreous brown insulator in repairs including one galvanised mild steel spindle, 02 Nos, GI washer & 01 No GI nut of 150mm height and 150mm dia for 11000 volts grade , complete all as specified and directed.
Material and labour for LT distribution panel, made out of 3.15 mm thick MS sheet, powder coated, dust & vermin proof, IP-66 Protection, Outdoor type factory made cubical totally enclosed type with front and rear door opening as per engineering practice provided with locking arrangement for opening of panel with provision of seperate chamber in upper part to enclose Aluminium bus bar of cap 1.5 times the rated capacity of incomming MCCB mounted on epoxy insulators in horizontal position and stepped manner with min 20cm distance between bus bars & panel body and 06 Nos separate chambers of adequate size embedded in 40mm thick PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate), on angle iron of size 40x40x6mm with footing 30 cm clear space between bottom of panel and flooring including all accessories prewired with insulated copper wires of suitable size, dressing the cable properly with lugs, nuts, bolts washer etc. & refixing the same. The panel shall compromise of the following fittings and fixture: (a) MCCB 160 Amps, 35 KA 4 pole - 01 No (incoming). (b) MCCB 100 Amps, 16 KA , 4 pole - 02 Nos (c) MCCB 63 Amps, 16 KA, 4 pole - 01 No (d) MCB SPN 16 to 32 Amps-02 Nos (e) Indicating lamps Led type (RYB). (f) Mutifunction digital meter with CTs & PTs of suitable size & Type idicating Volts, Amperes, PF, kW, kVA including energy meter - 01 No.
Supply and fixing chain link fencing made out of 4mm dia galvanised iron wire of diamond shape mesh of 75mmx75mm size including rails, straining bolts and provission of binding wire complete all as specified and directed
Supply and fixing Structural steel/tubular/box section/angle/flat iron including special shaped washers etc. omplete using ERW or induction butt welded tubes confirming to IS 1161-1979 grade St-240 complete all as specified and directed
Supply and fixing mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or sqare nut, n. exc 5 cm long and 16 to 20 mm dia of neck.complete all as specified and directed
Material and Labour for MS plain black sheet of thickness 1.6mm for panel canopy cut to size holes punched, including round headed screws, clout nails or rivets and fixed to steel framing with welded seams, including bending or turning up, complete all as specified and directed
Material and Labour for preparation of new steel surfaces of any description over 10cm in width or girth, not otherwise described and apply two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed
Material and Labour for 40mm coarse aggregates laying in sub stations and proper levelling , complete all as specified and directed
Supply and fixing LED flood light fitting 70 watt for operating voltage between 140V to 300V system efficiency not less than 110 lumen/watt PF-0.95 minimum , IP-66 protection, 57 CCT(K) CRI between 80-85 confirming to LM-79 and LM- 80 standard or as per IS-16104 2012 and IS 16106 2012 for estimated life span of minimum 50,000 hrs consisting of high/low voltage cut off maintenance free isolated Electronic driver with over voltage protection, surge protection and other safety test as per IS 15885 Part-2/Sec 13, Low THD, PMMA grade high quality Tranmittance lens Epoxy powder coated Die Cas Aluminium housing (heat sink ) with UV stabilized optics polycarbonate LENS for symmetrical light distribution weather proof gasket for lamp & driver compartment. Heat resistance toughened UV stabilized glass fitted in cast aluminium housing with SS screws , complete all as specified and directed
Supply and fixing junction box of size 200 x140x 95 mm out door type, weather proof factory made out of PVC sheet 1.8mm thick with front side hinged opening having looking arrangement with nuts & bolts & arrangement for infoming and out going cable/wire complete comprising with the followings :- (a) Bus bar with two aluminium strips 100 Amps cap. insulated with insulators, incl colour coding, including PVC cable of size from bus bar to MCB (b) MCB SPN 5 to 30 Amps-01 No (c) clamps made out of 25mm x 3mm flat iron duly welded with nuts & bolts , complete all as specified and directed
Material and Labour for for earth continuity conductor or main earthing lead/strip to wall or burried in ground or drawn in conduit (pipe/fixed to poles) of any type or any other situation for loop earthing etc with GI Strip of size 32 x 6mm, complete all as specified and directed
Material and Labour for Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, burried directly in ground (earth pit not less than 2.25 mtrs deep below ground level ) with top edge of the plate not less than 1.50 mtrs below normal ground level, connected to galavanised iron strip 32x6mm as earth lead up to test point with suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1 using 20mm graded stone aggregates, 40mm thick precast RCC cover in 1:2:4 reinforced with expanded metal(weight not less than 4 kg/sqm), and frame of angle iron 25x25x6mm with lugs 02 Nos with 6mm dia MS bar handle made to shape, excavation and earth work in any type of soil and including medium grade GI watering pipe 20mm bore with funnel and wire mesh and medium grade GI earth lead protection pipe 40mm bore upto main board comnplete as shown in electrical plate No 3 MES schedule Part-I, connected to earthing testing point and testing on completion complete all as specified and directed. Note : (i) The unit rate includes GI pipe upto 7.5m for protection of earth lead. For any additional length the same shall be adjusted through deviation order. (ii) The unit rate includes main earthing lead/strip from earth electode to test point upto 7.5 metre (iii) In case measured value of earth resistance is recorded more than 1.0 ohms then the earthing shall be re done by the contractor without any extra cost to the department. , complete all as specified and directed
Material and Labour for Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, burried directly in ground (earth pit not less than 2.25 mtrs deep below ground level ) with top edge of the plate not less than 1.50 mtrs below normal ground level, connected to galavanised iron earth lead wire 4.00 mm dia as earth lead up to test point with suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1 using 20mm graded stone aggregates, 40mm thick precast RCC cover in 1:2:4 reinforced with expanded metal(weight not less than 4 kg/sqm), and frame of angle iron 25x25x6mm with lugs 02 Nos with 6mm dia MS bar handle made to shape, excavation and earth work in any type of soil and including medium grade GI watering pipe 15mm bore with funnel and wire mesh and medium grade GI earth lead protection pipe 20mm bore upto main board comnplete as shown in electrical plate No 3 MES schedule Part-I, connected to earthing testing point and testing on completion complete all as specified and directed by Engr-in-charge Note : (i) The unit rate includes GI pipe upto 7.5m for protection of earth lead. For any additional length the same shall be adjusted through deviation order. (ii) The unit rate includes main earthing lead/strip from earth electode to test point upto 7.5 metre (iii) In case measured value of earth resistance is recorded more than 1.0 ohms then the earthing shall be re done by the contractor without any extra cost to the department.
Supply, installing, testing and commissioning outdoor typer step down transformer, 11KV/433 Volts (at no load) AC 3 Phase 50 Hz, 100 KVA Capacity, core type, double copper wound oil immersed, Oil Natural- Air Natural (ONAN) cooled, with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYn-11 with Neutral brought out on secondary side (LV Side) and having tapings at 2.5% and + 5% on HV side to be changed by menas of hand operated off load tap changer gear. The maximum temperature rise should not exceed 450 C in oil and 550 C in HV/ LV winding when measured by resistance method after continuous full load run on an ambient temp of 400 C. The transformer shall be as per IS-1180(Part-I) No load voltage ratio: 11/0.433 KV No. of Phase/ Freq. : 3 Phase/50 Hz. Type: Core type, double copper wound. Cooling: ONAN Vector group: DYN 11 Temperature rise (oil winding): 500/ 550 Taps on HV for HV variation: -7.5% to +7.5% in steps of 2.5 each (on circuit type) Termination (HV): Air filed cable box suitable for 11.00 KV, XLPE cable. Termination (LV): Air filed cable box suitable for 1.1 KV, XLPE cable. Conservator with drain valve and level gauge. Oil level indicator. Silica gel breather with oil seal. First filing of filtered oil as per IS-335 including makeup fill during installation of transformer puls 10% extra oil. On circuit switch.
Lifting lugs. Earthing terminals-2 Nos. Thermometer pocket including suitalbe thermometer of digital type. Air release plug. Inspection cover. Top filter valve-1 No. Drain Valve. Oil temperature and winding temperature gauge with max pointer. Rating and diagram plate. Bi-directional plain/flanged rollers. Disconnecting facility for HV cable box. Bucholz relay with alarm with necessary with copper conductor. Control cable, copper armoured from transformer to VCB for bucholz alarm & trip Marshal box. All the items like Exposive vent, One No 100 mm dia, dial type thermometer, vapour pressure release type having range 0-2000 C with metal guard having maximum perimeter temperature reading indicator with re-setting device. First filling of new and unused transformer oil, IS-335 marked filtered and tested upto 40 KV dielectric strength at 2.5 mm air gap between testing electrodes. Thermometer pocket on tank cover, Oil level guage, Oil drain filter valve, lifting lugs, oil filling hole with cap/ plug with connection plate complete, Air release valve plug and four Nos. plain solid vast steel detachable rollers Two earthing terminals on tank cover to facilitate fixing of 50x6 mm galvanised iron earth strip for earthing of body. Extra bushing for neutral, in the LT cable box for providing independent set of earthing for neutral are per standard accessories as per the standard in vogue.
M/S NANCY ENTERPRISES
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .