Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹8.7 L+₹64,947.50 (8.03%)Rejected-Finance H NO 33 VPO KHERI SALABAT PUR DISTT RUPNAGAR PUNJAB 140111 | RUPNAGAR | RUPNAGAR | PUNJAB | 140111 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹8.7 L+₹65,440 (8.09%)Rejected-Finance H NO 698 SECTOR 10 PANCHKULA HARYANA 134109 | PANCHKULA | PANCHKULA | HARYANA | 134109 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹9.5 L+₹1.4 L (17.6%)Rejected-Finance 0 0 KAIMGANJ ROAD KUIYA SANT FARRUKHABAD UTTAR PRADESH 209745 | FARRUKHABAD | UTTAR PRADESH | 209745 | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹10.5 L+₹2.4 L (29.7%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
₹13 L
EMD Value
₹26,000
Closing Date
25 Mar 2025, 6:00 pmClosed
GE I R AND D Chandigarh
Garrison Engineer I R and D, DIHAR Base Lab, Ground Floor, Near 3 (BRD) AF Stn, Industrial Area, Ph-II, Ramdarbar, Chandigarh
REPAIR AND MAINT OF HT/LT UG CABLES, LT PANELS, HT/LT SWITCH GEAR AND OTHER ALLIED MISC WORKS AT CHANDIGARH
2025_MES_699142_1
GE (I) R AND D/CHD-96/2024-25
Open Tender
Civil Works
Item Rate
180 days
Chandigarh
As per tender documents
8 documents required · 8 mandatory
₹500
GE I R AND D Chandigarh
₹26,000
Yes
26 May 2025
24 Feb 2025
27 Mar 2025
24 Feb 2025
25 Mar 2025
11 Mar 2025
Amount
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m deep in loose/soft soil and getting out for underground cable/erection of poles, stays , trench etc complete all as specified and directed
Material and labour for demolition of cement concrete / cutting of road/floor/hard standing/tiles/walls/pole coping etc for laying of LT cables/pipes/earth lead with suitable mechanism complete all as specified and directed. Note: Cable, pipes and PCC for finishing / filling disturbed area shall be measure and paid for separately under relevant item)
Material and labour for cement concrete (1:3:6) type C-1 using 20 mm graded stone aggregate cast-in-situ as mass filling, road filling, coping of pole ,around the pole and filling/finishing of disturbed area of road/floor/hard standing/tiles/walls and any other surface etc complete all as specified and directed.
Supply and fixing or laying in replacement HDPE (DWC) pipe of bore (inner dia) not less than 50 mm fixing on poles, walls under floors, laying on surface etc complete all as specified and directed. Note: (i)The rates of required accessories, bend, joints etc are deemed to be included in quoted rates . (ii) The rate of clamps, nut-bolts and any other MS items for fixing on wall/surface are measured and paid for separately under relevant item.
Supply and fixing or laying in replacement HDPE (DWC) pipe of bore (inner dia) not less than 100 mm fixing on poles, walls under floors, laying on surface etc complete all as specified and directed. Note: (i)The rates of required accessories, bend, joints etc are deemed to be included in quoted rates . (ii) The rate of clamps, nut-bolts and any other MS items for fixing on wall/surface are measured and paid for separately under relevant item.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick layers complete all as specified and directed .
Removal of excavated material n.exc 50 m away and depositing where directed at a level n.exc 1.5 m above from starting point complete all as specified and directed.
Disconnecting & taking out defective underground cable any size and any type from trenches, pole, pipe, floor, wall etc complete all as specified and directed. Note: (i) Earth work shall be measured and paid separately under relevant items. (ii) New cable may be laid down at separate location or route and old unsv cable may be retrieved from separate location as per site requirement . (iii) Size , type and quantity of cable will be issued in credit as actual found at site.
Supply and laying, connecting and testing XLPE underground cable insulated, and overall sheathed with aluminium conductor heavy duty 1100 volts grade 10 sqmm 4.0 core laid in trenches/ on poles/ road crossing or passing through existing/new pipe under road crossing, clamping on wall etc complete all as specified and directed. Note: (i) Earth work, removing, returning filling, PCC and pipe will be measured and paid separately. (ii) Cost of laying electrical cable through new/existing pipe under road, buildings, highways are incl in the quoted rates. (iii) All equipment , machinery or tools if required for laying electrical cable through new/existing pipes are provided by the contractor without any extra cost.
All as per serial item no 9.00 above but size 4.0 core 16 sqmm -ditto-.
All as per serial item no 9.00 above but size 3.5 core 25 sqmm -ditto-..
All as per serial item no 9.00 above but size 3.5 core 70 sqmm -ditto-..
Supply and fixing in repair or replacement energy saving & environmental friendly long life LED street light not less than 60 watt made up of pressure die cast housing with toughned glass and individual high power LEDs ,IP55/66 protection, impact resistant, LED efficacy >120 lm/W and system efficacy 90 lm/W , 240 Volts AC, 50 Hz, Power factor> 0.95, built in surge protection of up to 5kV incl make proper connection complete including cutting , welding , drilling holes, nut bolts, washer complete all as specified and directed
Supply and fixing in repair or replacement LED post top lantern of 1X20Watt with die cast aluminium spigot and lid cover, high efficient LEDs and clear acrylic cover IP-65, complete all as specified and directed.
Supply and fixing in repair or replacement energy saving & environmental friendly long life LED flood light not less than 70 watt made up of pressure die cast housing with toughned glass and individual high power LEDs ,IP55/66 protection, impact resistant, LED efficacy >120 lm/W and system efficacy 90 lm/W , 240 Volts AC, 50 Hz, Power factor> 0.95, built in surge protection of up to 5kV incl make proper connection complete including cutting , welding , drilling holes, nut bolts, washer complete all as specified and directed
Supply and fixing or laying PVC insulated flexible unarmoured cable three core with copper conductor 1.5 sqm size 1100 volt grade passing through PVC conduit for security light connection incl taking down old unsv and complete connection complete all as specified and directed. Note: PVC conduit shall be measured and paid for separately under relevant item.
Supply and fixing or laying PVC insulated flexible unarmoured cable three core with copper conductor 2.5 sqm size 1100 volt grade passing through PVC conduit for security light connection incl taking down old unsv and complete connection complete all as specified and directed. Note: PVC conduit shall be measured and paid for separately under relevant item.
Supply and fixing rigid non-metallic PVC conduit of external dia 20 mm exclusive of boxes (junction/ terminal) incl fixing on poles or wall or surface for flexible cable complete all as specified and directed. Note: (i) Clamps, nut, bolts etc for fiixng on poles/walls/surface are measured and paid for separately.
Supply and fixing in replacement MCCB TPN 400 amps , 415 Volts, 35/36 KA ,4 POLE, overload adjustable type incl complete all as specified and directed
Supply and fixing in replacement MCCB TPN 250 amps , 415 Volts, 35/36 KA ,4 POLE, overload adjustable type incl complete all as specified and directed
Supply and fixing in replacement MCCB TPN 160 amps , 415 Volts, 25 KA ,4 POLE, overload adjustable type incl complete all as specified and directed
Supply and fixing in replacement MCCB TPN 100 amps , 415 Volts, 16/18 KA ,4 POLE, overload adjustable type incl complete connection complete all as specified and directed.
Supply and fixing in replacement MCCB TPN 63 amps , 415 Volts, 16/18 KA ,4 POLE, overload adjustable type incl complete all as specified and directed
Material and labour cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts and wasters, clamps, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat paint, shape and size complete all as specified and directed.
Supply and fixing for KIOSK box weather proof made out of PVC , pole mounted, hinged door size 333 x 233 x 200mm out side and 300 x 200 x 105mm inside dimension comprising of aluminium bus bar 4 strips for 3 phase and neutral 63 Amp including clamps with necessary MS nuts bolts and washer complete all as specified and directed.
Supply and fixing for MPP heavy duty capacitor 20 KVAR 440/415 volts, 50 Hz, 3 phase, 3 number of element having temperature range upto 50 degree centigrade complete all as specified and directed.
Supply and fixing for MPP heavy duty capacitor 5 KVAR 440/415 volts, 50 Hz, 3 phase, 3 number of element having temperature range upto 50 degree centigrade complete all as specified and directed.
Material and labour for boring of holes under road, pavement, hard standing by mechanical means or any other technology including HDPE pipe 150 m dia suitable for 0.4 MPa working pressure complete all as specified and directed.
Supply and fixing for DOL motor starter MK 1 suitable for 7.5 HP electric motor 3 phase 415 volts AC, with single phase preventer with connections complete all as specified and directed.
Supply and fixing for changeover switches 4 pole 400 Amps , 415 volts in sheet metal enclosure incl fixing on wall/LT panel/any other surface using nut/bolts/Anchor fasteners and dismantling and taking down old u/s switch/MCB/MCCB/DB as available on site any type any size complete all as specified and directed.
Supply and fixing for changeover switches 4 pole 200 Amps , 415 volts in sheet metal enclosure incl fixing on wall/LT panel/any other surface using nut/bolts/Anchor fasteners and dismantling and taking down old u/s switch/MCB/MCCB/DB as available on site any type any size complete all as specified and directed.
Supply and fixing for changeover switches 4 pole 160 Amps , 415 volts in sheet metal enclosure incl fixing on wall/LT panel/any other surface using nut/bolts/Anchor fasteners and dismantling and taking down old u/s switch/MCB/MCCB/DB as available on site any type any size complete all as specified and directed.
Supply and fixing for automatic street light control with infrared sensor based NATRURE SWITCH and VOLTAGE MONITORING SYSTEM (VMS) Three phase load of 5 KW for automation of street lights. Nature Switch operation should be based on Natural light Lux level. Required illuminance level for switching ON is < 30 Lux and for switching OFF > 10 Lux. The sensor should also have part night operation facility of min. 4 hrs. to max. 12 hrs. VMS should have adjustable over & under Voltage trip level and protection against phase loss, Neutral loss & Phase reverse incl Power contactors (3 nos of capacity 16 amps per phase each) and incoming (3 nos of capacity 20 amps each)- outgoing MCB(3 nos of capacity 20 amps each) & main load circuit wiring (Copper) of minimum 10 sqm. The sensor , VSM, Power contactor, MCBs incl connected items should be enclosed in a Pole/wall mountable enclosure made of rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP54. The circuit should also have provision for manual operation (i.e. sensor & VMS By-Pass option) incl dismantling and taking down old u/s switch/MCB/timer any type as found actual at site. Model Swadeep- 02EC5kW3P-VMS or equivqlent in Schneider/Havells/Legrand Make (i) Nature switch: Kakatiya Energy Systems/Healer/Bajaj (ii) Power contactor- L&T / BCH / Schneider (iii) Voltage Controlling Device- L&T(GIC) or equivalent (iv) MCB-Hager/schneider/L &T /Legrand, (v) Enclosure & circuit sheet- Sintex (shock proof, rust proof, termite proof, FR rade) (v) Circuit wiring-Polycab/Finolex Note: (i) Nut , bolts, clamp for fixing on Poles/wall are to be included in quoted rates. (ii) The sensor must have the warranty of min of 1 years. (iii) Test certificate and warranty cirtificate must be provided by supplier. (iv) Cost of marking description on the box is incl quoted rates.
Servicing and repair of Air Circuit breaker (ACBs), and LT panle after taking proper shut down and disconnecting all electric supply , maint , cleaning, servicing and testing of LT breaker , bus bar, CTs, PTs, control cables connections, meters connection, tightening and checking of of AC and DC supply, testing of CT and PT , tightening and checking of control wires and other allied works , removing moisture and dust from LT breaker and inside of LT breaker through CRC and dry cloths, testing and checking of operating mechanism, testing and checking of AC and DC supply, testing of opening release and shunt closing , lubricants of all moving parts, testing and operation of On/Off through switch and push button ,checking of anti-pump device, repair of racking mechanism, earth alignment, tightening of loose connection and allied work at substations complete, all as specified and as directed. Note: (i) Tools , labour, petroleum jelly , CRC spray, dry cloths, nut -bolt, washers etc incl in the quoted rates. (ii) Rates of complete fixing, connection and testing of parts are incl in quoted rates. (iii) Parts, spares and anti tracking coating spray shall be measured and paid for separately.
Supply and fixing for GI perforated type cable tray of size 300 mm wide x 50 mm height and 2 mm thickness incl complete fixing on ceiling/wall with suitable size of MS angle support complete all as specified and directed. Note : The rate of clamps, nut-bolts, channel, angle and any other MS items for fixing on wall/surface/roof are measured and paid for separately under relevant item.
Supply and fixing for pure sine wave Automatic Inverter / home UPS for auxillary AC/DC supply required for VCBs is equipped with fan for cooling, power active switch, MCB protection and bypass switch which keeps supplying output from grid even in case of inverter faults, LCD display, charging current not less than 12A, efficiency 95 %, suitable for 24 Volts incl 2 nos batteries, 12 volts and 150 AH (with 24 Month warranty) each Input 220/240 Volts, 50 Hz, output power not less than 1200 Watt , 220/240 vots AC alongwith standard accessories incl dismantling and taking down old u/s power pack complete all as specified and directed
Supply and fixing for MPCB (Motor Protection Circuit Breaker) in existing panels system supply 415 vot AC, 50 Hz, adjustable type with test button suitable for 3 phase 10 HP motor with connection including dismantling and taking down old u/s MCBs complete all as specified and directed
Supply and fixing of single phase preventer in existing panels 415 volt 50 Hz suitable for 3 phase motor provide protection against single phaseing, reserse phasing and unblance suppy with connection complete all as specified and directed
Supply and fixing for MCB 4 pole 40 Amps with breaking capacity 10 kA with arrangment for fixing with over voltage relay with connection including dismantling and taking down old u/s MCBs complete all as specified and directed.
Supply and fixing for overvoltage release 230volts AC, 3 phase in 1 module suitable for 3 phase & neutral including, tripping voltage> 275 V including connection with MCB 4 pole complete all as specified and directed.
Disconnecting and taking out defective underground cable from trenches, pole, pipe, floor, wall, under road, cable trays etc and relaying in trenches, on cable trays, fixing on poles / walls/any other surface including connecting and testing for any size complete all as specified and directed
LA ENTERPRISES (BID ID -3265640)
bharat contrectors (BID ID -3269410)
R S ENTERPRISES (BID ID -3265961)
KHEHRA ENTERPRISES CONTRACTORS & GENERAL ORDER SUPPLIERS (BID ID -3270442)
Jai Maa Electrical Works (BID ID -3270092)
R D Bansal (BID ID -3270784)
Alpha Engineers and Builders (BID ID -3265800)
Bharat Enterprises (BID ID -3263212)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .