Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.4 CrAccepted-AOC MAHALSA ROAD BINAGA KARWAR 581307 | KARWAR | UTTARA KANNADA | KARNATAKA | 581307 | ₹1.4 Cr | 1 | Accepted-AOC Being the lowest and reasonable tender. |
| 2 | 2₹1.4 Cr+₹94,796.29 (0.69%)Rejected-Finance LEKSHMI NIVAS TELANG ROAD NANDANGADDA KARWAR 581 304 | KARWAR | UTTARA KANNADA | KARNATAKA | 581304 | ₹1.4 Cr+₹94,796.29 (0.69%) | 2 | Rejected-Finance Not being the lowest tender. |
| 3 | 3₹1.4 Cr+₹1.1 L (0.82%)Rejected-Finance | ₹1.4 Cr+₹1.1 L (0.82%) | 3 | Rejected-Finance Not being the lowest tender. |
| 4 | 4₹1.5 Cr+₹10.1 L (7.36%)Rejected-Finance | ₹1.5 Cr+₹10.1 L (7.36%) | 4 | Rejected-Finance Not being the lowest tender. |
| 5 | 5₹1.5 Cr+₹16.1 L (11.8%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹1.5 Cr+₹16.1 L (11.8%) | 5 | Rejected-Finance Not being the lowest tender. |
Tender Value
₹1.7 Cr
EMD Value
₹2.5 L
Closing Date
9 Sept 2024, 6:00 pmClosed
CE Navy Mumbai
HQ CE NAVY MUMBAI, SHAHID BHAGAT SINGH MARG COLABA MUMBAI-400005
ADDITION/ALTERATION AND SPECIAL REPAIRS TO BLDG NO. P-02 (TEG BLOCK) AT NAVAL BASE KARWAR
2024_MES_665406_1
87940/E8
Open Tender
Civil Works
Item Rate
639 days
Karwar
As per Tender Documents
7 documents required · 7 mandatory
₹1,000
Garrison Engineer (SB) Karwar
₹2.5 L
Yes
27 Nov 2024
11 Jul 2024
11 Sept 2024
11 Jul 2024
9 Sept 2024
1 Aug 2024
11 Jul 2024 - 18 Jul 2024
Amount
Dismantling /taking out existing textile coverings including frames (if any) or hessain base felt or any other existing water proofing treatment from roof including cement plaster and exposing the top surface of RCC slab including removing of dismantled material etc. complete all as specified and directed by the Engineer-in-charge.
Roughening/cleaning surfaces of roof/top surface of RCC slab etc. with wire brush, sweeping clean and washing down with water to remove dust etc. complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing for woven chicken wire mesh to exposed top surface of slab including necessary fixing materials, nails etc complete all as specified and directed by the Engineer-in-charge.
Material & Labour for cement concrete type B1 1:2:4 (20mm graded agg) in padding for levelling course of roof, rounded or chamfered edge sloping, coving all around at the junction of parapet and the roof slab etc. concrete mixed with water proofing compound etc complete all as specified and directed by the Engineer-in-charge.
Material & Labour for screed bed 15mm thick using WPC on concrete surfaces on roof top in CM 1:3 finished fair and smooth (without using extra cement) complete all as speified and directed. (WPC shall be measured and paid seperately). Note: Water Ponding Test to be carried out after cement concrete/Plaster work for roof for min 72 Hrs
Material & Labour for water proofing treatment by applying oil bound bitumen primer, having a density of 0.87 - 0.89 kg/lit, at the rate of 0.40 ltr/Sqm, providing and laying 4 mm thick APP modified water proofing membrane weighting not less than 3 kg/sqm of approved make including minimum 10cm side lap and 15cm end lap, laid and pasted with blue flame torching applications and finally finishing with solar reflective bituminous aluminium paint at the rate of 0.1 kg/sqm complete all as specified and directed by the Engineer-in-charge.
Material & Labour for Plain cement conrete (1:2:4 ) type B-0 using 12.5mm graded aggregate as in roof kerbs or mud stops rounded or chamfered edges complete all as specified and directed by the Engineer-in-charge.
Dismantling of single layer Mangalore pattern or similar tiles in roofing complete all as specified and directed by the Engineer-in-charge.
Material & Labour roof tiles, Mangalore pattern class 'A', interlocking at side joints, laid dry complete all as specified and directed by the Engineer-in-charge.
Material & Labour for Ridge or hip tiles to suit Mangalore pattern or roofing tiles, bedded and jointed in cement mortar 1:6 complete all as specified and directed by the Engineer-in-charge.
Material & Labour for applying two coats of water proofing coating system by applying shalicryl-215 of STP Ltd or Rain coat 601 of DR fixit or Barrier coat of Araldite over a coat of respective primer including preparation of newly/old plaster surface by complete removal of existing treatment including filling of crack with respective crack filler all as per manufacturers instructions all as directed by the Engineer-in-charge.
Demolition of concrete of any description and in any position not otherwise specifically provided for and removal of debris outside MoD land, complete all as specified and directed by the Engineer-in-charge. Note: (i) Before quoting the tender, the bidders are advised to ascertain the distance outside MoD land at which the excavated material/ debris are to be disposed off. No extra claim what-so ever shall be entertained on this account. (ii) This item shall be considered as per the requirement at site.
Treatment of sunken floor slab compriases of the following specifications and all as specified :-
(i) Material & Labour for cleaning the sunken/lowered portion of RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely. 40mm thick average PCC 1:2:4 type B0 using 12.5mm graded aggregate as in padding conc to achieve proper slope. (ii) Rendering of uneven surfaces with 5mm thick CM 1:4 mixed with integral water proofing compound @ 3% BY WT OF CEMENT CONSUMED. Fill it with water and check dampness and seepage. Where dampness/seepage is noticed, nozzles shall be fixed and grouting to be carried out (WPC shall be measured and paid separately). (iii) All junctions points of side wall where CI/GI pipes are passing through shall be sealed with epoxy putty. (iv) After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean. (v) Material & Labour for applying two coats of polymer modified cementious water proof coating as per manufacturers instruction to bottom and vertical sides up to finished floor level +100mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky,, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion complete all as specified and directed by the Engineer-in-charge. (This item shall be measured and paid separately). (vi) Plaster the bottom and sides up to bottom of the skirting with minimum 20mm thick CM 1:4 mixed with integral water proofing compound @3% wt of cment consumed as per manufacturer's specification including rounding of corners and junctions sloping towards spout. (WPC shall be measured & paid separately). (vii) All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 etc complete all as specified and directed by the Engineer-in-charge. Note :- Test the water proofed area (ponding test) by filling water for at least 72 hours and tested for leakage seepage and to the entire satisfaction of GE. Test shall be done in presence of reps of PMG and record for each sunken slab shall be maintained. The treatment shall be carried out by authorised applicators of chemicals. Cost of testing is included in the rates quoted above.
Material & Labour for applying two coats of polymer modified cementious water proof coating as per manufacturer's instruction to bottom and vertical sides up to finished floor level+100 mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion complete all as specified and directed by the Engineer-in-charge.
Supply only Integral Water proofing compound complete all as specified and directed by the Engineer-in-charge.
Material & Labour for PCC in 1:5:10 type E2 (using 40 mm graded agg) as in sunken floor of toilet complete all as specified and as directed by the Engineer-in-charge.
Taking up or down GI tubing and connections 15mm bore including cleaning or removal to store complete all as specified and directed by the Engineer-in-charge.
Taking up or down GI tubing and connections 20mm bore including cleaning or removal to store complete all as specified and directed by the Engineer-in-charge.
Taking up or down GI tubing and connections 25mm bore including cleaning or removal to store complete all as specified and directed by the Engineer-in-charge.
Taking up or down GI tubing and connections 32mm bore including cleaning or removal to store complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing 15 mm dia UPVC pipes of pressure rating 10 Kgf/cm2 fixed to walls, ceiling or in floors including jointing cleats, elbows and etc complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing 20 mm dia UPVC pipes of pressure rating 10 Kgf/cm2 fixed to walls, ceiling or in floors including jointing cleats, elbows and etc complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing 25 mm dia UPVC pipes of pressure rating 10 Kgf/cm2 fixed to walls, ceiling or in floors including jointing cleats, elbows and etc complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing 32 mm dia UPVC pipes of pressure rating 10 Kgf/cm2 fixed to walls, ceiling or in floors including jointing cleats, elbows and etc complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing in repairs stop valves/angle valve, cast copper alloy fancy type chromium plated with long shank and cup (concealed type), screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe of 15mm bore complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing in repairs stop valves/angle valve, cast copper alloy fancy type chromium plated with long shank and cup (concealed type), screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe of 20mm bore complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing in reapir 25 mm dia gun- metal globe or gate valves, with iron wheel head screwed both ends for iron pipe & fixed etc complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), including disposal of debris out side the MoD land etc. complete all as specified and directed by the Engineer-in-charge.
Material & Labour for digital coloured ceramic tiles 300x450x7-8 mm thick in vertical surfaces (including designed borders) such as skirting and dados set and jointed in neat cement slurry pointed in coloured cement to match over rendering 10 mm thick on fair faces of brick work in CM (1:4) complete all as specified and directed by the Engineer-in-charge. Note:- Rate of Designer border in vertical surface shall be deemed to be included into quoted rate.
Material & Labour for non skid ceramic coloured tiles 7 to 8 mm thick (Square/ rectangular), area of each tile exc 0.06 Sqm but n.exc 0.11 sqm (size of tile 300mm X 300mm) as in floors etc laid over and including 15mm thick screed bed in CM 1:4 and set and jointed in neat grey cement slurry and pointed in white or coloured cement to match complete all as specified and directed by the Engineer-in-charge.
Material & Labour for Non Skid coloured ceramic tiles 7 to 8 mm thk (square/ rectangular) area of each tile exc 0.18 Sq.m but n exc 0.38 sqm (size of tile 600mm X 600mm) laid in floors with neat cement slurry @ 3.00 kg/Square Metre over and including 15 mm thick screed bed of cement mortar (1:4) including pointing in white cement with pigment to match the shade of tiles etc complete all as specified and directed by the Engineer In Charge.
Material & Labour for Non Skid coloured ceramic tiles 7 to 8 mm thk (square/ rectangular) area of each tile exc 0.11 Sq.m but n exc 0.18 sqm (size of tile 400mm X 400mm) laid in floors / steps with neat cement slurry @ 3.00 kg/Square Metre over and including 15 mm thick screed bed of cement mortar (1:4) including pointing in white cement with pigment to match the shade of tiles etc complete all as specified and directed by the Engineer In Charge.
Material & Labour for cement concrete tiles 25cm X 25cm X 22mm thick, machine pressed, (with grey cement & no pigments), set jointed and pointed in neat cement slurry in floors over and including 15 mm thick bedding layers in CM 1:6 all as specified & directed by the Engineer-in-charge.
Taking down chowkats or frames exc. 1.5sqm but not exc. 4 sqm each but with shutter (without taking off shutter from the frame) including making good disturbed portion to match the adjoining surfaces etc complete all as specified and as directed by the Engineer-in-charge.
Taking down chowkats or frames not exc. 1.5 sqm each but with shutter (without taking off shutter from the frame) including making good disturbed portion to match the adjoining surfaces etc complete all as specified and as directed by the Engineer-in-charge.
Supply & Fixing solid PVC door frame of size 50mmx 47mm made out of 5mm wood grains printed PVC sheet reinforced with MS square tube and edges painted to match with printed sheet complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing factory made solid panel PVC door shutter 30 mm thick (styled) consisting of frame made out of MS tube for top & bottom rails, MS frame shall be covered with heat moulded wood grain printed PVC "C" channel having a 5mm thick x 15mm wide PVC sheet beading used inside stiles and rails and wood grain printed colour PVC sheet for top rail, lock rail and bottom rail on either side & as gap inserted for top rail and bottom rail, panelling of wood grain printed colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with decorative PVC beading of 10mm x 10mm (90 degree) and jointed together with salvent cemet supplying and fixing in the frame at site complete all as specified and directed by the Engineer-in-charge.
Material & Labour for Cutting holes in brick walls or cement concrete walls exc one brick but not exc two bricks built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required etc complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing Mild steel Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 etc complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing 150mm long Aluminium anodized handle of extruded sections etc complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing 100 mm SS Butt hinges fixed with SS screws complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing 150mm long aluminium anodized barrel tower bolts of extruded sections complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing 300mm long aluminium alloy, anodized sliding door bolts with hasp & staple (bolt type) and fixing clips of sheet cost of extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing in repairs vitreous china wash down water closet (pedestal pattern) white, including fixing bolts and necessary connection with existing pipes etc complete all as specified and directed by the Engineer-in-charge. Note: Quoted rate shall excludes the cost of flush pipe, cistern & seat cover and the same shall be paid seperately under respective item.
Material & Labour as in repair vitreous water closet (squatting pan, Orissa pattern, size 575x440x250mm CAT Part No. ECS-WHT-451LE in Jaquar or techno-commercial equivalent in Parryware or Hindware as approved white, with integral foot rests and 'P' trap (excluding flushing cistern and flush pipe) including provision of lime concrete bedding complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing in repair for seat cover for pedestal pan with plastic water closet seat , white, closed pattern with flat bottom and cover amnd mild steel chromium plated or aluminised hinging device complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing in repairs for 10 litre capacity PVC valveless syphonic action type flushing cistern high or low level (exclusive of brackets) white with inlet ball valve, float and handle inlcuidng brackets complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing in repairs for providing 15 mm dia PVC connection of length 450mm long complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing in repairs flush pipes PVC 32mm dia for low level flushing cisten to pedestal pan, including all joints, cones, India rubber (nozzles of W.C pans) complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25m long flexible tube and ABS wall hook including making connection and fixed in positions complete all as speified and directed by the Engineer-in-charge.
Supply & Fixing in repairs two way bib cock with two lever and wall flage chromium plated brass of approved make, screwed for iron pipe 15mm bore complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing Oval shaped under counter Wash hand basin vitreous china size 590 x 420 mm including brackets waste brass chromium plated with long screwed shanks and fly nuts 32 mm size complete all as specified and directed by the Engineer-in-charge.
Demolition of stone slabs and tiles of any description or thickness in floor, approns etc laid bedded and pointed in any mortar complete all as specified and directed by the Engineer-in-charge.
Material & Labour for 18-20 mm thick Granite (of any type) work black colour (table rubbed and polished) in wash as in counter, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by the Engineer-in-charge.(Rates are inclusive of cutting portion as per the required size of counter sunk wash hand basin, sink and fixing etc complete).
Material & Labour for machine pressed pre-cast concrete interlocking coloured paver block of any size and shape onforming to IS-15658-2006 of 80mm thickness M-40 grade with grey cement and pigment etc complete all as specified and directed by the Engineer-in-charge.
Material & Labour for stone dust or sand base filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled, and blinded with earth and rammed including watering etc complete all as specified and directed by the Engineer-in-charge.
Material & Labour for PCC 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing in repairs fancy type pillar taps cast copper alloy with capstan heads chromium plated screwed down high pressure with lettered hot or cold with long screwed shanks and fly nuts screwed for iron pipe and 15 mm bore of pipe.
Supply & Fixing in repairs for vitreous china urinals, half stall (back or corner wall type,) complete including providing and fixing plugs bedding urinal against wall in cement mortar in 1:2 securing urinals to plugs with and including 60 mm long brass screws, pointing around urinal back in cement etc complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing Self-closing taps, cast copper alloy, chro-mium plated, screwed for iron pipe of 15mm dia and fixed for urinals in repairs complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing in repairs 32mm size waste fitting (coupling) brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed all as specified and directed by the Engineer-in-charge.
Supply & Fixing in repairs 32mm dia PVC waste pipe for WHB and urinals fixed in repairs complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing in repairs toilet paper holder with flat recessed type stainless steel etc complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing brass CP towel rail, 20mm dia, D type, 60 cm long between flanges fixed in repairs complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing in repairs Brass chromium plated shower rose with or without swivel joints, of 125mm size fancy type suitable for 15mm bore GI pipe all as specified and directed by the Engineer-in-charge.
Supply & Fixing in repairs brass chromium plated mixer for mixing hot & cold water screwed down for 15mm dia iron pipe of complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing in repairs bib taps, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe 15mm bore complete all as specified and directed by the Engineer-in-charge.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings,heads,shoes,bends,swan-necks etc including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing PVC (SWR) 110mm bore pipes in any length with rubber ring joints fixed to wall with dash through fastners and rain water bracket suitable for 110mm pipe spacing 1.5m c/c as per CE (Navy) Mumbai TD No TD/2023/01 complete all as specified and directed by the Engineer-in- charge.
Supply & Fixing PVC (SWR) 75mm bore pipes in any length with rubber ring joints fixed to wall with dash through fastners and rain water bracket suitable for 110mm pipe spacing 1.5m c/c complete all as specified and directed by the Engineer-in- charge.
Supply & Fixing 75mm dia PVC (SWR) bend complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing 110mm dia PVC (SWR) bend complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing 110mm dia PVC (SWR) reducers complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing 75mm dia PVC (SWR) junction single T equal or unequal complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing 110mm dia PVC (SWR) junction single T equal or unequal all as specified and directed .
Supply & Fixing 110mm bore PVC floor trap with SS gratings including jointing to waste pipe with solvent cement complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing PVC (SWR) floor trap of 75mm dia, plain with grating including jointing with solvent cement etc complete all as specified and directed by the Engineer-in-charge.
Material & Labour 110 mm dia. PVC rain water pipes with Socket and including Stack clamps out of 50mm by 5mm including bolts and nuts and securing ends of stay to wall or roof for 110mm pipe complete all as specified and directed by the Engineer-in-charge.
Material & Labour 75 mm dia. PVC rain water pipes with Socket and including Stack clamps out of 50mm by 5mm including bolts and nuts and securing ends of stay to wall or roof for 75mm pipe etc complete all as specified and directed by the Engineer-in-charge.
Material & Labour for 110 mm dia PVC (SWR) branch piece, double (double Y) equal or unequal etc complete all as specified and directed by the Engineer-in-charge.
Material & Labour for 75 mm dia PVC (SWR) branch piece, double (double Y) equal or unequal etc complete all as specified and directed by the Engineer-in-charge.
Taking down cement plaster on brick or concrete surfaces of wall/ceiling and likes including racking out joints, hacking for keys scrubbing down with water etc any description including removal of rubbish outside MoD land, complete all as specified and directed by the Engineer-in-charge. Note : The rate quoted by the Contractor is deemed to be included necessary scafolding and form works.
Material & Labour for rendering 15 mm thick on brick or concrete surfaces in cement mortar (1:4) etc complete all as specified and directed by the Engineer-in-charge.
Material & Labour for rendering 10 mm thick on brick or concrete surfaces in cement mortar (1:6) etc complete all as specified and directed by the Engineer-in-charge.
Material & Labour for rendering 5mm thick on fair faces of brick work or concrete surfaces in CM 1:3 as in ceiling etc complete all as specified and directed by the Engineer-in-charge.
Material & Labour for preparation of new plastered / decorated wall surfaces applying two coats of Acrylic Emulsion exterior grade, weather proof antifungal Paint over a coat of primer including necessary scafolding and safety measures as required etc complete all as specified and as directed by the Engineer-in-Charge.
Material & Labour for applying two coats of oil bound distemper over a coat of primer over wall care putty of average thickness 2mm in two layers on internal surfaces of wall complete all as specified and directed by the Engineer-in-charge. Note: Work will be executed by authorised applicator of approved manufacturer.
Material & Labour for applying two coats of oil bound distemper on old decorated ceiling including complete removal of existing treatment by washing, rubbing down and over 2mm thick putty in two layers complete all as specified and directed by the Engineer-In-charge. Note: Work will be executed by authorised applicator of approved manufacturer.
Material & Labour for preparation of old plastered / decorated wall surfaces including complete removal of existing treatment by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc complete and applying two coat of oil bound distemper over a coat of alkaline resistant primer including necessary scafolding and safety measures as required etc complete all as specified and as directed by the Engineer-in-charge.
Material & Labour for preparation of old plastered / decorated ceiling surfaces including complete removal of existing treatment by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc complete and applying Two coat of Oil Bound distemper over a coat of alkaline resistant primer including necessary scafolding and safety measures as required etc complete all as specified and as directed by the Engineer-in-charge.
Material & Labour for preparation of old plastered / decorated wall/ceiling surfaces including complete removal of existing treatment by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc complete and applying two coat of Acrylic Emulsion exterior grade, weather proof antifungal Paint over a coat of primer including necessary scafolding and safety measures as required etc complete all as specified and as directed by the Engineer-in-charge.
Material & Labour for preparation of old previously treated wooden surfaces of any description over 10cm width or girth and applying two coat of synthetic enamel paint including necessary scafolding and safety measures as required complete all as specified and directed by the Engineer-in-charge.
Material & Labour for complete removal of old treatment and applying two coats of synthetic enamel paint on steel surfaces of any description complete all as specified and directed by the Engineer-in- charge.
Material & Labour 75mm thick PCC (1:3:6) type-C2 using 20 mm graded stone aggregate as in hardstanding/plinth protection and finishing the concrete surface even and smooth without using extra cement complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing 20mm dia stainless steel curtain rod or similar articles complete all as specified and as directed by Engineer in Charge.
Supply & Fixing stainless steel decorative type brackets suitable for 20mm dia curtain rod or similar articles complete all as specified and as directed by Engineer in Charge.
Supply & Fixing Second Class class hard wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed etc complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides coveredwith decorative laminates on both faces etc complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing 30mm thick second class hard wood, Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats but divided into squares, with plain, chamfered or rounded, mitred and rebeted sash bars, any numbers etc complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing 200mm long aluminium anodized barrel tower bolts of extruded sections complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing for 140mm long floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring fixed in floor complete all as specified and as directed.
Material & Labour for preparation of new wooden surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed by the Engineer-in-charge.
Material & Labour for Powder Coating (minimum thickness of powder coating 50 micron) aluminium frame for doors, windows, ventilators & Partitions with one or more rebates including joining cleat for fixing etc. complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows, ventilators etc. including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket, etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge. Note: a) Glazing shall be measured seperately. b) Item shall be paid as per weight of aluminium section. c) The rate quoted shall be inclusive of neoprene beading, glazing clips, screws, etc., as required which shall not be measured for arriving the weight. d) The rate shall be inclusive of the locking arrangement including complete packing with silicon gel around contacting surfaces of aluminium work, and including matching the existing surface area
Supply & Fixing 4.0 mm thick Sheet glass ordinary quality and glazing with oil putty in square not exc. 0.5 sqm in each pane fixed to Aluminium windows/ventilator etc complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing Anodised Aluminium grill (anodised transperent or dyed to required shade according to IS 1868 with minimum anodic coating of grade AC 15) of approved design / pattern, with approved standard section and fixed to existing frame with CP brass stainless stell screws @ 200mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening all complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.
Dismantling boarding, of any size and any description, fixed in any position with screws etc complete all as specified and directed by the Engineer-in-charge.
Material & Labour for 18mm thick PVC Ply Board/Sheets both sides plain as in Cupboard Door, Partition, Draws & shelves including solvent cement & beadings etc as per manufacturer's instructions complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing 40mm width of flaps (when open) Continuous (piano) hinges, stainless steel, bright finish or electrogalvanised fixed to cupboard door etc complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing magnetic catches brass body and striking plate including letting complete all as specified and as directed by Engineer in Charge.
Supply & Fixing 20mm dia anodised aluminium alloy curtain rod or similar articles complete all as specified and as directed by Engineer in Charge.
Supply & Fixing anodised aluminium alloy type brackets suitable for 20mm dia curtain rod or similar articles complete all as specified and as directed by Engineer in Charge.
Dismantling of PVC/ RCC water storage tank of capacity exceeding 1000 litre but not exceeding 2000 litre etc complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing Rotational moulded PVC, double layered, water storage tanks of capacity 2000 litre (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in position, complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing Rotational moulded PVC, double layered, water storage tanks of capacity 1000 litre (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in position, complete all as specified.
Material & Labour for providing and injecting emulsion for post construction antitermite treatment along the external wall below concrete or masonary apron using chemical emulsion at the rate of 2.25 litres per linear metre including drilling holes and plugging the holes with cement mortar & matching the existing surface etc complete all as specified and directed by the Engineer-in-charge.
Material & Labour for providing and injecting emulsion for post construction antitermite treatment at points of contacts of wood with masonry / concrete surfaces using chemical emulsion mixed with oil or kerosine at the rate of 0.5 litres per hole including drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and plugging the holes with cement mortar (1:2) etc to match with existing surface complete all as specified and directed by the Engineer-in-charge.
Material & Labour for Excavating in trenches, not exc. 1.5 m wide and not exc. 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying/ taking out cable, etc. not exc. 10 sqm on plan and not exc. 1.5 m in depth and getting out in soft or loose soil.
Material & Labour for Excavating in trenches, n exc 1.5 m wide and exc 1.5 m in depth beyond the first 1.5 m depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft or loose soil.
Material & Labour for Returning and filling in including spreading, levelling, watering and well rammed in layers not exec 25 complete all as specified and as directed as in hard/dense soil complete all as specified and as directed.
Demolition and breaking up of SWG (salt glazed stone ware) drain pipes of Internal dia of pipe 200mm set in cement mortar including demolition of PCC in haunching /benching around pipes required complete all as specified and directed by the Engineer-in-charge.
Material & Labour for PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in concrete bed of Internal dia of pipe 200mm including packing under and haunching against the sides of pips after they are laid and tested complete all as specified and directed for the following.
Material & Labour for 200mm bore Reinforced concrete pipes, Class NP2, laid in trenches and jointed with cement slurry and yarn complete all as specified and directed by the Engineer-In- charge.
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles including disposal of debris out side the MoD land etc complete all as specified and directed by the Engineer-in-charge.
Material & Labour for providing precast cement concrete block masonary with solid blocks exc 10 cm width, type C-1 (1:3:6) using 20mm graded aggregate and set in cement mortar (1:6) complete all as specified and directed by the Engineer-in-charge.
Material & Labour brick work with sub class 'B' bricks old size, straight or curved on plan to any radius in half brick wall in cement mortar 1:4 complete all as specified and directed by the Engineer-in-charge.
Material & Labour for rendering 15mm thick plastering in cement mortar 1:4 on fair faces of brick work or concrete surfaces mixed with integral water proofing compound as per manufacturers instructions, finished even and smooth without using extra cement complete all as specified and directed by the Engineer-in-charge. Note : Integral water proofing powder will be measured and paid separately under relvant item of Schedule 'A'.
Dismantling wrought iron or mild steel work of any description not otherwise specified for.
Supply & Fixing for cast iron/mild steel Sections of Grade Fe 410-W, (Gde- E-250) quqlity-A, as in chamber,drain etc fixed with connecting plates including bending, welding etc complete.
Material & Labour for preparation of new steel surfaces exc 10cm width of girth and applying two coats of synthetic enamel paint over a coat of red oxide primer.
Removing excavated material (any type) and disposing it outside Ministry of Defence Land complete all as specified and directed by the Engineer-in-charge. Note:(i) Before quoting the tender, the bidders are advised to ascertain the distance outside MD and at which the excavated material/ debris are to be disposed off. No extra claim what-so ever shall be entertained on this account. (ii) This item shall be considered as per the requirement at site.
Supply & Fixing readymade 7 Feet Pulley operated clothes drying system, consisting of aluminium anodised 22mm outer dia pipe & inner dia 19.8mm, Pulleys madeup of derlinwith rope guide mounted on channel pair of length 24'' (distance between pipe is adjustable) locking system to hide rope knot, chanel to be mounted or fixed with self tapping screws, ropes of 4mm dia HDPE double core fixed to ceiling with all accesories etc complete all as specified and directed by Engg-In-Charge.
Internal Electric Supply
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
Material & Labour for point wiring with 1.5 Sqmm PVC (FRLS) insulated sheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continous earth wire to common earth and connected to earth with 1.5 Sqmm PVC (FRLS) insulated sheathed multi stranded copper conductor cable draw in existing conduit for one light/fan point controlled by one switch and making good disturbed surfaces to match with the existing surface complete all as specified.
Material & Labour for point wiring with 1.5 Sqmm PVC (FRLS) insulated sheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continous earth wire to common earth and connected to earth with 1.5 Sqmm PVC (FRLS) insulated sheathed multi stranded copper conductor cable draw in & incl PVC surface casing 'N' capping double lock type to be fixed with the help of rawal plugs & screws incl necessary fittings & fixture and to be turminated in sunk cast iron/pressed steel/PVC terminal boxes for mounting switches & sockets with 3 mm thick plastic laminated sheet cover of adequate size for one light/fan point controlled by one switch and making good disturbed surfaces with CM (1:4) to match with the existing surface complete all as specified.
Same as item no. 138 but for One 5 Amps socket point on independent board
Material & Labour for point wiring with 1.5 Sqmm PVC (FRLS) insulated sheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continous earth wire to common earth and connected to earth with 1.5 Sqmm PVC (FRLS) insulated sheathed multi stranded copper conductor cable draw in conduit including CI/MS/PVC sunk boxes for mounting switches, sockets, regulators etc with 3 mm thick plastic laminated sheet cover of adequate size for one light/fan/bell point controlled by one switch and making good disturbed surfaces with CM (1:4) to match with the existing surface complete all as specified and directed by Engineer-in-charge.
Ditto as per item No. 141 above but for 2 in 1, 3 pin switch socket outlet 5 Amp on same board with other switches, complete all as specified.
Material & Labour for point wiring with 1.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continous earth wire to common earth and connected to earth with 1.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable draw in & incl PVC surface casing 'N' capping double lock type to be fixed with the help of rawal plugs & screws incl necessary fittings & fixture and to be turminated in sunk cast iron/pressed steel/PVC terminal boxes for mounting switches & sockets with 3 mm thick plastic laminated sheet cover of adequate size for 5 pin switch socket outlet 5 Amp on independent board and making good disturbed surfaces with CM (1:4) to match with the existing surface complete all as specified.
Material & Labour for point wiring with 2.5 Sqmm PVC (FRLS) insulated sheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continous earth wire to common earth and connected to earth with 2.5 Sqmm PVC (FRLS) insulated sheathed multi stranded copper conductor cable draw in & incl PVC surface casing 'N' capping double lock type to be fixed with the help of rawal plugs & screws incl necessary fittings & fixture and to be turminated in sunk cast iron/pressed steel/PVC terminal boxes for mounting switches & sockets with 3 mm thick plastic laminated sheet cover of adequate size for 3/5 pin switch socket outlet 15/16 Amp on independent board and making good disturbed surfaces with CM (1:4) to match with the existing surface complete all as specified.
Material & Labour for point wiring with 4.00 Sqmm PVC (FRLS) insulated sheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continous earth wire to common earth and connected to earth with 4.00 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable draw in & incl PVC surface casing 'N' capping double lock type to be fixed with the help of rawal plugs & screws incl necessary fittings & fixture and to be turminated in sunk cast iron/pressed steel/PVC terminal boxes for mounting switches & sockets with 3 mm thick plastic laminated sheet cover of adequate size for 3/5 pin switch socket outlet 15/16 Amp on independent board and making good disturbed surfaces to match with the existing surface complete all as specified.
Material & Labour for dismantling and taking down fluorescent tube light frame single/double /street light fittings of any wattage or size for repair or replacement of burnt/worn out accessories complete all as specified and directed.
Fixing only LED tubelight batten 20 W, 4 feet length, 2000 lm, 6500 K complete with all as specified and as directed
Supply & Fixing round shape LED tubelight batten 20 W, 4 feet length, 2000 lm, 6500 K complete with all as specified and as directed. Make: Havells/Bajaj/Philips/C&S
Taking down fan/ exhaust fan sealing cable end, dismantling blades and removing fan and blades to stores.
Hanging only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan.
Supply & Fixing in repair stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required.
Fixing only in repair stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required.
Fixing only exhaust fan and connecting up including provision of cable from ceiling rose/connector to fan
Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Fixing only LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply & Fixing in reapir Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings all as specefied and directed.
Fixing only in reapir Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings all as specefied and directed.
Supply & Fixing in repairs switch piano 5 Amps one way flush type, ISI marked, all as specified and directed. Make: Anchor/Havells/Philips/Crompton Greaves/Bajaj
Supply & Fixing switch piano 5 Amps one way flush type, ISI marked, all as specified and directed. Make: Anchor/Havells / Philips/ Crompton Greaves/ Bajaj
Fixing only in repairs switch piano 5 Amps one way flush type, matching with existing make, ISI marked, all as specified and directed.
Supply & Fixing in repairs socket outlet 2 in 1, 3 pin, 5 Amps flush type, make ISI marked, all as specified and directed. Make: Anchor/Havells / Philips/ Crompton Greaves/ Bajaj
Supply & Fixing socket outlet 2 in 1, 3 pin, 5 Amps flush type, make ISI marked, all as specified and directed. Make: Anchor/Havells / Philips/ Crompton Greaves/ Bajaj
Fixing only in repairs socket outlet 2 in 1, 3 pin, 5 Amps flush type, matching with existing make ISI marked, all as specified and directed.
Supply & Fixing switch socket combination 6 Amps/16 Amp, 5 in 1 flush type, multi purpose, ISI marked, all as specified and directed. Make: Anchor/Havells / Philips/ Crompton Greaves/ Bajaj
Material & Labour in repair for sub main wiring with four runs of single core PVC FRLS insulated cable with copper conductor multistranded 1100 volts grade 16.0 sqmm through and including with suitable size of PVC conduit and its accessories, concealed on wall surface in ceiling along with fixing arrangement and including Necessary cutting and chasing etc including two runs of 16.0 sqmm PVC insulated multistranded copper earth contuinuity conductor and connected to common earth dolly complete all as specified. Note: (i) Each submain wiring shall run in separate PVC conduit. (ii) PVC casing caping wiring shall be provided where concealed wiring is not feasible (i.e. concrete surface/beam column/ceiling etc). The same shall be deemed to include in the quoted rate. No extra cost shall be paid for the PVC casing caping item.
Supply & Fixing in repair of sheet metal enclosure MCB DB TPN 8 ways double door type all as specified and directed .
Supply & Fixing in repair 415 V 10 KA 'B' curve MCB of TPN 16 to 32 Amp current carrying capacity in the DB complete with connection testing and commisioning.
Supply & Fixing in repair 415 V 10 KA 'B' curve MCB of TP 40 to 63 Amp current carrying capacity in the DB complete with connection testing and commisioning.
Supply & Fixing in repair amp rating 240V, 10KA 'B' curve miniature circuit breaker (MCB) SP of 6 to 32 Amps current rating complete with connection testing and commissioning.
Material & Labour in repair for MCCB 4 pole, 415 V of 125 Amps current rating with breaking capacity 16 KA complete with connection testing and commissioning complete all as specified and directed.
Supply & Fixing in repair of sheet metal enclosure VTPN MCCB 125A DB double door, 8 way, IP43 type complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing in repair inverter lamp 9 watts with backup time to 4 hrs,auto cut off after full battery charging complete all as specified and directed by the Engineer-in-charge.
Supply & Fixing LED bed side reading light fititng with movable string, 3W complete with driver to operate on 240V AC 50 Hz suitable for indoor application complete all as specified and directed.
External Electric Supply
Supply & Laying in repair including jointing, testing and commissioning in repair of 3.5 core 95.00 Sqmm XLPE insulated, armoured, heavy duty, LT UG electric cable with aluminum conductor 1100 volt grade including provision of lugs, glands etc laid in trenches or fixed on wall/pole or drawn through GI pipe complete all as specified and directed by Engineer-in-charge. Note - (i) Excavation & earth work, sand cushioning and PCC cover for cable protection will be measured & paid for seperately.
Supply and lay un-reinforced pre-cast concrete cable cover, class LV, type 1, flat, size 250mm x 150mm x 40mm in replacement of existing burnt bricks complete all as directed.
Supply and spread dry river sand in trenches for cable cushioning all as specified in clause 19.75 of SSR Part-I. Note:- Punned thickness of sand only will be measured & paid.
Supply and lay GI tubing, 'light grade' of size 100 mm ,with all fittings as in cable protection, laid in trenches all as specified and directed by Engineer-in-charge.
Material & Labour in repair for MCCB 4 pole, 415 V of 200 Amps current rating with breaking capacity 36 KA complete with connection testing and commissioning complete all as specified and directed.
Material & Labour for cutting the tarmac/ hard standings and excavating in trenches across the road for laying cable including making good the excavated portion by means of PCC 1:3:6, type C1 matching with surrounding all as specified.
Cooling Appliannces
Supply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase having approx storage 120 ltrs and nominal cooling capacity 60 ltrs .
Hot Water Supply
Supply & Fixing electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc.
LEKSHMI ENGINEERS (BID ID -3076613)
KVL CONSTRUCTION (BID ID -3091297)
ABDUL RAHIM (BID ID -3091033)
Shree Ayyappa Engineering (BID ID -3091902)
ANKIT SHIP REPAIRERS AND SUPPLIERS (BID ID -3091809)
KOTIAN -ECC (BID ID -3083576)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .