Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹2.4 LAccepted-AOC D 3 195 CHITRAKOOT NAGAR AJMER ROAD JAIPUR JAIPUR RAJASTHAN 302021 | JAIPUR | RAJASTHAN | 302021 | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹2.5 L+₹1,150 (0.47%)Rejected-Finance H 27 UPPER GROUND FLOOR MOHAN GARDEN UTTAM NAGAR NEW DELHI DELHI 110059 | WEST | DELHI | 110059 | L-2 | Rejected-Finance L-2 |
Tender Value
₹2.6 L
EMD Value
₹5,152
Closing Date
13 Mar 2021, 6:00 pmClosed
EE(E), Jodhpur
The Executive Engineer (E), BSNL,Electrical Division, Ist Floor, Administrative Building, Pal Road, Subhash Nagar Jodhpur-342008. ( Mob -9414001017
SITC of 3 Nos. x 7 TR Microprocessor based High Precision type AC units with Air Cooled Condensers for Infrastructure works of IAF site under NFS Project Uttarlai-2 Barmer Rajasthan SHAssociated Work
2021_BSNL_71828_1
12/EE(E)/BSNL/ED/JPR/2020-21
Open Tender
Electrical Works
Item Rate
60 days
Uttarlai-2
Please refer Tender documents.
4 documents required · 4 mandatory
₹590
Accounts Officer(Cash), BSNL, O/o G.M.T.D. JODHPUR
₹5,152
1 Apr 2021
1 Mar 2021
16 Mar 2021
1 Mar 2021
13 Mar 2021
1 Mar 2021
Amount
Supplying, installing, balancing and commissioning of fabricated at site GSS sheet metal rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, support as per approved drawing and specifications of following sheet thickness complete as required.
(ii) Thickness 0.80 mm sheet
SITC of fire dampers in supply air paths complete as required
SITC of duct dampers in supply air main ducts / branch ducts complete as required
Providing, Making & Fixing of flaxibal Double Layer canvas connection complete as required.
SITC of indoor extensible type sheet steel metal clad, totally enclosed rigid floor mounted, air insulated cubical type M.V. panel made out of minimum 1.66 mm thick sheet steel metal with name plate, labels and shall be folded and braced as necessary to provide rigid support , separate housing for each switch, MCCB, Bus bar fixing arrangement i/c painting with powder coating paint, mounted with complete accessories suitable for operation on 415 volt, 3 phase, 4 wire 50 Hz, A.C. supply system, MCCB shall be provided with handle interlock & Door interlock having electrical and mechanical interlocking arrangement including interconnection with 2.5 sqmm FRLS PVC insulated copper conductor crimping the lugs, ferrules and sign wrighting, interconnection between busbar to outgoing switchgear and outgoing switch gear to connector in cable alley by adequate rating copper conductors pvc insulated wire and supply & fixing of Announciator control alarm (audio/visual) system window /panel in this panel. Including S/F of MS base channel of size 100mm X 50mm & the panel shall fixing on MS base channel of size 100mm X 50mm i/c minor civil works, panel made out as per CPRI guidelines and relevant IS/IEC codes etc. as required, consisting of following items. (For details see attached specification). Note:- 1. The panel shall be type tested design at CPRI / Independent test house for the rating required. 2. Panel drawing should be got approved from Engineer in charge before fabrication.
Supply and fixing of PVC insulated PVC sheathed aluminum conductor armoured cable of following sizes on the existing MS tray /walls with saddles/PVC of cables with glands etc. as required
i) 4 x 10Sqmm (for Pkg.)
Supply and fixing of following PVC insulated PVC sheathed copper conductor armoured cable for control wiring on the existing MS tray / walls with saddles/PVC thread/cable tie, screws etc. I/c end termination of cables with glands etc as required.
i) 4 x1.5sqmm
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
i) 100mm width x 50mm x 1.6mm thickness
SITC 25mmx5mm thick G.I. strip for loop earthing on cable tray wall etc as required
Supply of one number PVC insulated and PVC sheathed XLPE power cable of 1.1 KV grade of 3.5x35 sqmm aluminium conductor armoured cable etc. as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Up to 35 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface / recess as required.
Up to 35 sq. mm (clamped with 1mm thick saddle)
Supplying and making end termination with brass compression gland and aluminium for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3½ X 35 sq. mm (32mm)
Supplying and fixing of AC plant information board made out of 12 mm thick both side white colour prelaminated partical board of 3 feet x 2 feet i/c sign writing on board as per instruction by Engg in charge etc complete as reqd
Conducting initial and final Acceptance testing as per department norms complete with all required necessary tools, controls and equipments etc. as directed. ( For items covered in this agreement)
ENVICAIR ENGINEERS PVT LTD
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .