| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.7 LAccepted-AOC 58 1ST FLOOR PATEL NAGAR BATHINDA | BATHINDA | BATHINDA | PUNJAB | L1 | Accepted-AOC Being a First Lowest | |
| 2 | L2₹22.2 L+₹1.5 L (7.21%)Rejected-Finance | L2 | Rejected-Finance Being not Lowest | |
| 3 | L3₹22.9 L+₹2.2 L (10.4%)Rejected-Finance LADO CHACK COLONY PO TEH DISTT PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance Being not Lowest | |
| 4 | L4₹24.4 L+₹3.7 L (17.8%)Rejected-Finance | L4 | Rejected-Finance Being not Lowest | |
| 5 | L5₹24.9 L+₹4.2 L (20.2%)Rejected-Finance HOUSE NO 104 WARD NO4 MOHALLA WADHERIAN PATHANKOT GURDASPUR PUNJAB 145001 UDYAM PB 16 0006453 | PATHANKOT | PUNJAB | 145001 | L5 | Rejected-Finance Being not Lowest |
Tender Value
Refer Docs
EMD Value
₹57,071
Closing Date
18 Dec 2023, 6:00 pmClosed
GE(W)Pathankot
GE(W)Pathankot
PROVN OF TOILET BLOCK NEAR FWC AND PROVN OF SINTEX TANKS AND COVER SHEDS AT MD ACCN OF 69 COY ASC UNDER GE (WEST) PATHANKOT
2023_MES_628788_1
GE/PKT-52/2023-24
Open Tender
Miscellaneous Works
Item Rate
180 days
Pathankot
As per tender and NIT doc
9 documents required · 9 mandatory
₹500
GE(W)Pathankot
₹57,071
24 Jan 2024
18 Nov 2023
20 Dec 2023
18 Nov 2023
18 Dec 2023
4 Dec 2023
Amount
Sch 'A' Part-I B/R work:- Surface excavation not exc 30 cm depth and averaging 15cm deep and getting out in soft/loose soil complete all as specified and as directed
Excavation in trenches, not exceeding 1.5 m wide and not exc 1.5 m in depth for foundation, and not exceeding 10 sqm on plan for manholes, pier hole, shafts, wells, laying of pipes etc and getting out in any type of soil, complete all as specified. and directed by Engr-in-Charge.
All as per Srl item No. 2 here-in-before but exc 1.5m and n.exc 3m in depth
All as per Srl item No. 2 here-in-before but exc 3m and n.exc 4.5m in depth
Excavation over area not exceeding 1.5 m depth and getting out in any type of soil, complete all as specified and directed by Engr-in-Charge.
All as per item No 5 here-in-before but exceeding 1.5 m and not exceeding 3.00 m depth.
M&L for Cement concrete Type D-2 1:4:8 (using 40 mm graded graded crushed stone aggregate) in foundations, filling and mass-concrete and sub base of floor complete all as specified. and directed by Engr-in-Charge.
M&L for Plain cement concrete 1:2:4 type B-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed by the Engr-in-Charge.
Demolition of brick work or stone/ boulder masonry built in cement mortar or cement lime mortar including all quions, wall, arches, pillars, man-holes, drain etc complete all as specified and directed.
M&L for brick work with sub class 'B' brick, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.
All as per Srl item no. 10.00 here-in-before but except brick work
M&L for brick work with sub class 'B' brick, straight or curved on plan n.exc 6 m with bricks roughly cut to radius or bricks with wedge shaped joints built in cement mortar 1:4 complete all as specified and directed.
M&L for Fly ash brick work, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for Fly ash brick work, straight or curved on plan to any radius in half brickthick walls built in cement mortar 1:4 complete all as specified and directed.
M&L for brick work with sub class 'B' bricks, in one brick thick honeycomb walling built in cement mortar 1:4 complete all as specified and directed.
Returning filling in including spreading, levelling, watering and well remming in layers not exceeding 25cm thick in hard/dense soil complete all as specified.
Removal to excavated material (Soil) to a distance not exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by Engr-in-Charge.
M&L for RCC M-15, type B-1 (using 20mm graded crushed stone aggregate) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed by Engr-in-Charge.
M&L for RCC M-15, type B-1 (using 20mm graded crushed stone aggregate) in Columns, pillars, piers, posts and struts complete all as specified and directed by Engr-in-Charge.
M&L for RCC M-15, type B-1 (using 20mm graded crushed stone aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed by Engr-in-Charge.
M&L for RCC M-15, type B-1 (using 20mm graded crushed stone aggregate) in chajjas complete all as specified and directed by Engr-in-Charge.
M&L for RCC M-15, type B-1 (using 20mm graded crushed stone aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engr-in-Charge.
M&L for RCC M-15, type B-1 (using 20mm graded crushed stone aggregate) in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilaster and buttresses complete all as specified and directed by Engr-in-Charge.
Precast reinforced cement concrete, type B-1,1:2:4 (using 20mm graded crushed stone aggreagate)as in in landings, manhole cover set in cement mortor 1:6 , including neccessory form work complete all as specified and directed by Engr-in-Charge. (Note:-TMT bars will be masured and paid sepretly)
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed
Use and waste of formwork to sides of pillars, posts, struts, piers, columns etc square or rectangular or polygonal complete all as specified and as directed
Use and waste of formwork to sides and soffits of floor or roof beams, beam haunch?ings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and as directed
Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and as directed
Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete rail?ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizon?tal or sloping and similar work exc 10cm but n exc 20cmwide complete all as specified and as directed
Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter
S&F mild steel TMT bars 10 mm dia and over, cut to length , bent to shape required including cranking , bending spirally for hooping for columns, hooking ends, binding with and including mild steel wire ( annealed ) not less than 0.9mm dia , complete all as specified and directed by Engr-in-Charge.
All as per srl item No. 31 here-in-before but 6mm to 8mm dia
All as per srl item No. 31 here-in-before but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders
M&L for 25 mm thick plain cement concrete type B-0, 1:2:4 (using 12.5 mm graded crushed stone aggregate) as in sub base finished even and rough without using extra cement as in flooring complete all as specified and directed.
M&L for 75mm thick PCC 1:4:8, type D-2 using 40mm graded crushed stone aggregate as in sub base Finishing surfaces of concrete to be even and rough complete all as specified and as directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc.& Brushing neat cement slurry with 3.0kg of cement per sqmetre complete all as specified and directed.
M&L for joint free non skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including laid over screed bed of 15mm thick of cement mortar 1:6 all as specified and directed.
M&L for joint free non skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including laid over screed bed of 15mm thick of cement mortar 1:6 all as specified and directed.
M&L for non skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in skirtings etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including laid over screed bed of 15mm thick of cement mortar 1:6 all as specified and directed.
M&L for Glazed coloured ceramic tiles in vertical surface 450X 350X 7-8mm thick such as skirting dado, etc set and jointed in neat cement slurry and pointed in white or colour cement to match the shed of tile including laid over 10mm thick backing layer of cement mortar (1:4) complete all as specified and as directed
Taking down cement plaster of any description and thickness on walls/ceilings etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 5mm thick on fair faces of brickwork or concrete surfaces in cement mortar 1:3 as on ceiling finished even and smooth without using extra cement complete all as specified and directed.
M&L for Rendering 15 mm thick on fair faces of brick work or concrete/stone surfaces in CM 1:4 finished even and smooth without using extra cement mixing with liquid water proofing compound as per manufacturer instruction complete all as specified. (Note:WPC shall be measured and paid sepratly)
Supply only liquid water proofing compound all as specified and as directed.
M&L for Rendering 10 mm thick on other than fair faces of brick work or concrete/stone surfaces in CM 1:6 finished even and smooth without using extra cement complete all as specified.
M&L for Rendering 15 mm thick on fair faces of brick work or concrete/stone surfaces in CM 1:6 finished even and smooth without using extra cement complete all as specified.
M&L for preparation of newly plastered surfaces of wall and applying a one coat of wall care putty on the surfaces & making the surface absolutely smooth surface and applying two coat of oil bound distemper complete all as specified and as directed.
M&L for preparation of new plastered surfaces and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed by Engr-in-Charge .
M&L for 3 coats of white wash on new plastered surfaces of wall including preparation of surfaces all as specified and as directed.
M & L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for complete removing existing treatment plstered surface of wall and applying a one coat of wall care putty on the surfaces & making the surface absolutely smooth surface and applying two coat of oil bound distemper complete all as specified and as directed.
M&L for complete removing existing treatment plstered surface of wall and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed by Engr-in-Charge .
M&L for complete removing existing treatment plastered surfaces of ceiling and applying two coats of white wash complete all as specified and directed.
M&L for 75 mm thick PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in flooring, PCC path, plinth protection and surface finished even and fair with out using extra cement all as specified and as directed.
M&L for hardcore of Broken stone or boulders n.exc. 63mm, deposited spread and leveled in layers n.exc. 15 cm thick watered and rammed to a true surface complete all as specified and directed.
S&F vitreous China under counter wash basin, with fixing , oval shape snow whiteof size 560mmx400mmx205mm, incl 32mm dia brass chromium plated wastecoupling, and 32mm dia PVC waste pipe complete all as specified and directed by Engg-in-charge. Make:- Cat part No. S2030103 of CERA or equivalent as mentioned in list of approved make
S&F single piece WC with UF soft close seat cover, hinges, fixing accessories, accessories set and cistern fittings size 680mmx360mmx720mm, 'S' trap 220mm white with combined flush tank (Cascade type) including seat covers complete all as specified and directed by Engg-in-charge. Make:- Cat part No. S1013178 of CERA or equivalent as mentioned in list of approved make
S&F looking mirror with shelf fancy type of size 800mmx600mm, 5mm thick clear glass shelf with stainless steel rail and silver plating on the back for better reflection approved quality and make complete all as specified and directed by Engg-in-charge. Make:- Cat part No. B3510149 of CERA or equivalent as mentioned in list of approved make
S&F brass CP Health Faucet ABS body with wall hook and 1 mtr long CP PVC Flexible Tube Chrome Finish complete all as specified and directed. Make:- Cat part No. F8030103 of CERA or equivalent as mentioned in list of approved make
S&F corner glass shelf(medium), size 225mmx225mm with bracket fixed with chromium plated brass screws and wooden/plastic cleats complete all as specified and as directed.
S&F Brass CP Toilet paper Roll Holder with fixing arrangement complete all as specified and as directed.
S&F brass CP overhead shower 100mm dia round with 200mm long shower arm and wall flange, complete all as specified and as directed.
S&F 15mm bore Brass CP central hole basin mixer without popup waste system with 450mm long braided hoses, screwed down complete all as specified and directed. Make:- Cat part No. F2008461 of CERA or equivalent as mentioned in list of approved make
S&F brass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed.
S&F 15mm bore fancy type Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' , screwed for iron pipe complete all as specified and directed.
S&F 15 mm bore CP Bib taps cast copper alloy fancy type with capstan heads (chromium plated),and with crutch or butterfly handle, screwed down , high pressure for iron pipe complete all as spd & directed.
S&F 15mm bore dia fancy type capstan head, chromium plated angular valves /stop valves, cast copper alloy, screwed down, high pressure ,screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F 15mm bore dia fancy type capstan head with long sank and cup (concealed type) angular valves /stop valves, cast copper alloy, screwed down, high pressure ,screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floor of 75mm bore pipe complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floor of 110mm bore pipe complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall of 110mm bore pipe complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) bends of radius 110mm bore complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) bends of radius 75mm bore complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) junction single, (single-T), equal or unequal of 110mm bore complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC (SWR) junction single, (single-T), equal or unequal of 110mm bore complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) junction single, (single-T), equal or unequal of 75mm bore complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) 110mm bore vent cowl complete all as specified and directed by Engr-in-Charge.
M&L for PVC (SWR) floor trap 75 mm with grating, setting and jointing with solvent cement complete all as specified and as directed
M&L for PVC (SWR) multi floor trap 75 mm with grating, setting and jointing with solvent cement complete all as specified and as directed
S&F Grating doom 100 mm dia of PTMT (Minimum weight 25gms) complete all as specified & directed.
Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, shelves, lintels, etc, and cutting chases for concealed water tubing or conduit wiring, etc and making good, cutting not exceeding 10cm girth complete all as specified and directed.
S&F galvanised iron, medium grade with all fitting and fixed complete to walls and ceilings or laid in floors in any length of 20 mm bore pipe complete all as specified and directed by Engr-in-Charge
All as per Srl item no. 83.00 here-in-before but 15 mm bore
S&F brass CP Soap Dish or Soap Holder Dish round/oval shaped for Bathroom with fixing arrangement complete all as specified and as directed.
S&F 15 mm dia PVC connection of 600mm long including 2 Nos CP brass check nuts
S&F Rotational moulded polyethlene water storage tanks three layers of 500 ltrs capacity ISI marked (cylindrical vergical with closed top) hoisted and fixed in position with all fittings all as specified in SSR Part I including 20mm thick Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm-210 gms) complete all as specified and as directed.
S&F gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipes of 15 mm bore all as specified and as directed.
All as per Srl item no. 88.00 here-in-before but 20 mm bore
S&F factory made Pressed steel frame of size 125x60x1.25mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, complete and back filling of hollow portion of frame including fixing of hold fast with plain cement concrete type B-0, 1:2:4 using 12.5 mm graded crushed stone aggregate complete all as spd and directed
S&F Factory made solid PVC printed/moulded door shutte 28 to 30mm thick (style) with 2, 4 or 6 raised panel design with 5mm thick moulded PVC sheet on front side face and 5mm plain colour PVC sheet on back face all as specified and as directed.
Factory made fully glazed/wire gauge single piece front side PVC printed door shutter 35mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Paneling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing complete all as specified .
S&F factory made Solid PVC Door Frame of size 50mm x47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Paneling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing complete all as specified .
S&F 150mm long extruded aluminium alloy handles, fabricated type, anodised
S&F 200mm long aluminium anodised, barrel tower bolts of extruded section
S&F 100mm long butt hinges, medium weight, cold rolled mild steel
S&F 250mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.18mm and fixed with stainless steel wire staples or using metal nut and bolts complete all as specified .
S&F steel window/Ventilator factory made box type and shutter (double shutter) with sash bar made out of section using flash butt welding, hinges shall be provided to both shutters complete including all fittings including grills made out of 10 mm dia round bars glazing with 3 mm thick oridinary glass, guaging (wire mesh stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.18mm and fixed with stainless steel wire staples or using metal nut and bolts ) and two coat synthetic enamel paint over and including a coat of red oxide primer all as per drg No CEPZ/ TD-245/01 Sheet 1/1 and CEPZ/TD-246/01 sheet 1/2 & 2/2 complete all as specified & directed.
M&L for cleaning of plastered/concrete surfaces and applying roof treatment on top of roof with APP modified membrane with non woven polyster reinforcement/mat (centre core) with thermal insulation with white minral gravel finish on upper side of weight not less than 3.5kg/sqm and thickness not less than 3mm, laid by torch application method with overlap 100mm on length side and 100mm on the width side as per manufacturer instructions over a coat of approved cold applied bituminous oil based primer (IS-3384) @0.30 ltr/Sqm and including 20 mm thick screed bed in CM 1:4 including mixed with water proofing admixture as per manufacturer's instructions and ensur water does not stand anywhere after sprinkle water on the roof surface complete all as specified and directed.
M&L for 60mm thick M-35 Grade, coloured rubber moulded glossy finish Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 with grey cement and pigment including 25mm thick sand cushioning bed complete all as secified and directed.
M&L for non abrasive paving (endura) tiles 300mm x 300mm x10mm thick (square/ rectangular) polished, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement over & including 15mm screed bed CM 1:4 to match complete al as specified and directed. Note:-The texture ,colour ,Shade of tiles & laying of tiles to any pattern & any design with one or more colours shall be approved by GE and Rates also including in this item for necessary raking circular cutting or notching and waste on tiles and brushing neat cement slurry with 3.0kg of cement per sqm complete all as specified and directed
M&L for 18-20mm thick granite (pure black) work (table rubbed and polished) in steps, jambs pillars, window cills ,cooking platform and like including pointing in white cement (1:2) using marble dust with admixture of pigments to match with shade or granite over including 15mm thick screed bed or bedding layer in cement mortar 1:4 complete all as specified and directed.
M&L for Cement Concrete , 1:2:4, type B-1 using 20mm graded crushed stone aggregate as in lintel upto 1.50 m span, cills, steps, seismic and other silmilar bands, plinth courses, sring courses,lacing courses, parapets and railings upt 60 cm in height, copings, kneelers, apex stones, bed plates, water troghs and the like including weathering, slightly rounded or camphered angles and throating, complete all as specified and directed by Engr-in-Charge.
M&L for 150mm dia reinforced concrete pipes, class NP-3, laid in tranches and jointed complete with collars complete all as specified and directed by Engr-in-Charge.
M&L for concrete bed to drain pipe in PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) including packing under and haunching against the sides of pipe after laid and tested for 150 mm bore pipe, complete all as specified and directed by Engr-in-Charge.
M&L for brocken brick as Loose filling with aggregates of gauge 40 to 80 mm in soakage pits, soakage wells complete all as specified and directed by Engr-in-Charge.
S&F in repair 100mm dia Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to wall complete all as specified.
S&F 100mm dia cast iron bends , diminishing pieces or tapers (larger bore measured) complete all as specified.
Demolition of PCC (un-reinforced) in ground floors & pavings n.exc 15 CM thickness below or above ground level, complete all as specified and directed by Engr-in-Charge.
S&F 10 ltrs capacity PVC valve less, syphonic action type, flushing cistern, low level, white, with intel, ball valve, float and handle including brackets ,fush pipe of polyethylene of low or high density or PVC 32 mm dia complete all as specified.
S&F sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with CP bracket guard & railing 60cm long fixed with chromium plated brass screws and wooden/plastic cleats complete all as specified and directed.
S&F Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
S&F mild structural steel angles/rectangular hollow section/steel tubular roof trusses (framed), purlines and fastening including distance pieces etc. complete all as specified and directed.
M&L for cutting down plants / trees of girth not exc 15 cm & surface area not exc 36 cm each from roof tops /sides of external walls of buildings, chajja, wall junctions, junctions of of rain water / soil /waste vent pipes including taking out roots entered in wall/slab surfaces and making good the surfaces including repairing the CI/GI/PVC joints of affected locations by applying TUFALO (herbal medicine )and making good to suit the adjoining surfaces using PCC type 1:2:4, type B-0 (using 12.5mm graded crushed stone aggregate) or cement mortar 1:2 complete all as specified and as directed.
Sch 'A' Part-II E/M work:- M&L for point wiring for one light/one fan controlled by one switch with 1.5 Sqmm PVC insulated unsheathed multistrand copper conductor FRLS cable with and including PVC concealed conduit heavy duty 20 mm dia having thickness not less than 1.8 mm with all fittings including anodise pressed steel sunken box having thickness not less than 2mm with 3mm thick bakelite laminated sheet ISI marked for switches and sockets , including 1.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS cable as earth continuity conductor connected to comman earth dolly, including cutting chiseling for concealed piping and making good disturbed surface to match with the existing surface complete all as specified and directed.
All as per Srl item No 118 here-in-before but for 5 pin 5 amps socket outlet on independent board complete all as specified and directed.
M&L for point wiring with 2.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS cable with in and including PVC concealed conduit heavy duty 20mm dia having thickness not less than 1.8 mm with all fittings including anodise pressed steel sunken box having thickness not less than 2mm with 3mm thick bakelite laminated sheet ISI marked suitable for 5 pin 15 amps socket outlet ,including 2.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS cable as earth continuity conductor connected to comman earth dolly in and including cutting chiseling for concealed piping and making good disturbed surface finishing the surface to match with the existingsurface complete all as specified and directed.
S&F switch piano flush type one way 5 amps SP 240 volts complete all as specified and directed.
S&F switch piano flush type one way 15 amps SP 240 volts complete all as specified and directed.
S&F socket outlet 2 in 1, 3 pin 5 amps flush type 240 volts complete all as specified and directed.
S&F socket outlet 2 in 1, 5 pin, 5 and 15 amps flush type 230 volts complete all as specified and directed.
S&F lamp holder/batton holder/angle holder insulated body with bakelite back plate suitable for fittings complete all as specified and directed.
S&F ceiling rose 65 x 50mm three terminals complete all as specified and directed.
S&F sleek LED mirror light fitting 2 feet long 1x10 W including LED tube 2 feet long of same make having ballast , bipin holder, connector block etc. complete with all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 Sqmm 3 core complete all as required at site or directed.
S&F LED bulb, B22 type ,14 watt,complete all as specified and directed.
S&F sleek LED Batten light fitting 4 feet long 1x20 W including LED tube 4 feet long of same make having ballast , bipin holder, connector block etc. complete with all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 Sqmm 3 core complete all as required at site or directed.
M&L for providing/ cutting the round/ square hole of required size in wall finishing the distrubed surfaces as per existing finishes complete all as spd and supply and fixing propeller PVC AC ventilating fans, Engineering plastic with louvers shutter,Single phase, 230 volts 250 mm sweep complete and supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated three core 1.5 sqmm copper cable from ceiling rose to exhaust fan motor and writting MES No. with black synthetic enamel paint 2.0 cm high complete all as spd and directed by Engr-in-charge.
S&F MCB SP 6-32 Amp 240 volt AC with 10KA breaking capacity of 'C' series in distribution boards all as specified and directed.
S&F MCB SPN 32 Amp 240 volt AC with 10KA breaking capacity of 'C' series in distribution boards all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode , 600 x600 x 6mm thick burried directly in the ground (earth pit not less than 2.25 mtr deep below ground level)with top edge of the plate not less than 1.5mtr below ground level connected to galvanised iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point , GI tubing 15 mm bore light grade protection pipe , GI watering pipe 20mm bore light grade with funnel and wire mesh , charcoal ,salt packed around the earth plate and precast PCC 1:2:4 (Nominal mix ) reinforced with XPM having weight not less than 4 kg /sqm including suitable handle of 6mm dia MS bar and angle iron 40x40x3mm frame for cover including earth work in any type of soil , removal of surplus soil to a distance n.exc 50m and connecting , testing on completion complete all as shown on electric plate No 03 of SSR -2009 Part I and connecting to existing earth test point complete all as specified and directed or including testing on completion.(Note: Excavation and earth work is deemed to be included in the rates quoted).
M&L for sub Main Wiring with two Run of single core PVC insulated unsheathed multistrand FRLS flexible copper conductor cable of size 2x4 sqmm and one PVC insulated multistrand unsheathed FRLS flexible copper conductor cable of size 4 sqmm (green colour) as earthing lead connecting to main earthing dolly drawn in and including non metallic PVC concealed conduit 20mm dia complete and making good to disturbed surface complete of wall/floor with cement mortar and finishes to match the existing surface complete all as specified and directed. Note:-Two run of submain wire (phase and neutral) and one run of earth wire including PVC conduit and accessories will be measured as one run.
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with 20 Amp single pole MCB.
S&F sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 4 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good the disturbed wall surface with cement mortar to match with existing surface complete all as specified and as directed by Engg-in-charge.
Supply and installation of the electric water storage heater of ABS body type, 25 ltr capacity with rated power 2KW, 5 star rated, vertical type, thermally insulated mild steel tank with glass line coating inside the tank alongwith glass lined including heating element with anti corrosive magnesium anode, NRV, thermostat, indicators and temperature adjustable knob including steel braided flexible connection for pipe of size 15mm bore with GI hexagonal adopters/nuts on both sides for inlet (cold water supply) & outlet (hot water supply) and including provision of wall mounting arrangements and mounting on wall with suitable size of anchor bolts with complete connection of water including testing after installation complete all as specified and as directed.
Om Sai Ram Builders
DABGOTRA BUILDERS
v k engineers and builders
Ambika Construction Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .