Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 CrAccepted-AOC RAM KISHEN DINESH OJAH ROAD P O ULUBARI P S BHANGAGARH GUWAHATI DIST KAMRUP M PIN 781005 | KAMRUP METRO | ASSAM | 781005 | ₹2.0 Cr | L1 | Accepted-AOC Work Order Issued |
| 2 | L2₹2.0 Cr+₹1.5 L (0.77%)Rejected-AOC HARI HAR ENCLAVE 3RD FLOOR CHRISTIAN BASTI G S ROAD GUWAHATI 781005 KAMRUP M ASSAM | KAMRUP METRO | ASSAM | 781005 | ₹2.0 Cr+₹1.5 L (0.77%) | L2 | Rejected-AOC L2 |
Tender Value
₹2.0 Cr
EMD Value
₹3.9 L
Closing Date
12 Jan 2023, 2:00 pmClosed
Spl. CE, PWD(Bldg) (H AND E) Assam, Ghy-3
O/O The CE, PWD (Bldg), Assam, Chandmari, Ghy-3
Construction of Development School Infrastructure at Shankardev Sishu Niketan, Geetashram, Hojai under Sishu Siksha Samiti, Assam
2022_PWBNH_28417_1
TECH.II/139/2022/3 Dated Guwahati 14th Dec. 2022
Open Tender
Civil Works - Building
Item Rate
365 days
Hojai
Please refer Tender documents.
4 documents required · 4 mandatory
₹3,920
₹3.9 L
Yes
O/O The CE, PWD (Bldg), Assam, Chandmari, Ghy-3
15 Mar 2023
23 Dec 2022
13 Jan 2023
23 Dec 2022
12 Jan 2023
23 Dec 2022
30 Dec 2022
Amount
EARTH WORK IN EXCAVATION Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in- charge. All kinds of soil.
Extra for every additional lift of 1.5 m or part thereof in excavation/ banking excavated or stacked materials. All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and stacking at site. Stone screening 11.2 mm nominal size (Type B)
PLINTH FILLING Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
BRICK SOLING Providing soling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. Brick on flat soling
Filling sunken floor with broken jhama brick bats and sand including compacting and supplying of materials complete as specified and directed for all levels.
CONCRETE WORKS: 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
MASONRY WORK Brick work with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
DAMP-PROOF COURSE Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
FORMWORK Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform
Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, propping etc. and removal of form for : Stairs (excluding landings) except spiral-staircases
Centering and shuttering including strutting, propping etc. and removal of form for : Arches, domes, vaults up to 6 m span
Centering and shuttering including strutting, propping etc. and removal of form for : Extra for arches, domes, vaults exceeding 6 m span
Centering and shuttering including strutting, propping etc. and removal of form for : Weather shade, Chajjas, corbels etc., including edges
PLINTH PROTECTION Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation leveling and dressing and finishing the top smooth.
PLINTH PROTECTION DRAIN Providing drain with cement concrete (1:3:6) 10cm thick sides 10cm thick bed over brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. i) 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge.
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 300 mm dia. R.C.C. pipe
Steel Reinforcement Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Autoclaved Aerated concrete (AAC) Block Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate
CEMENT PLASTERING 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand)
15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand)
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Wall painting (two coats) with Plastic emulsion paint of approved brand and manufacture on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth.Approved brand and manufacture: Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac/ LaGreens
Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works.
ENAMEL PAINT Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
WPC DOOR FRAME Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Celestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In-charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. Frame size 65 x 150 mm
WPC DOOR SHUTTER Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic Additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw Withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately): 30 mm thick
WPC DOOR SHUTTER: Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) : 30 mm thick
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately): Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS:12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin-charge.: Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
Filling the gap in between aluminium frame & adjacent RCC/ Brick/Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.: Upto 5mm depth and 5 mm width
Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).
Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm
Tile work in skirting, risers of steps and dado up to 2 m height over 12 mm thick bed of cement mortar 1:3 (1 cement :3 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm, including pointing in white cement mixed with pigment of matching shade complete. Marble tiles (polished) Raj Nagar 8 mm thick
ANTI-SKID TILES Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Antiskid finish of size Size of Tile 600 x 600 mm
WALL TILES Providing VITRIFIED wall tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement:3 coarse sand) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) (Qutone, AGL, Vermora, Jhonson or equivalent make) IMARBLE 1200mmx2400mm (9mm)
STAINLESS STEEL Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.
M.S GRILL Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.
ANTI-TERMITE TREATMENT Treatment of soil under existing floors using chemical emul sion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% Concentration
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 100 mm nominal size dia
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 150 mm nominal size dia
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (SUCTION PIPE) External work 40 mm nominal outer dia Pipes
Providing and placing in position filters of 40 mm diameter G.I./PVC pipe with brass strainer of approved quality.
Providing and fixing gun metal non- return valve of approved quality (screwed end) : 40 mm nominal bore Horizontal
Providing and fixing gun metal non- return valve of approved quality (screwed end) : 40 mm nominal bore Vertical
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 100 mm dia
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 150 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm clamp
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 100 mm dia
EWC: Providing fitting and fixing Vitreous china wall hang water closet (European type W.C pan 400mm high) with seat and lead, CP brass hinges and rubber buffers, CI/MS brackets, 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately) a) White (ii) Wall mounted Closet (inclusive of seat cover and fittings) Jacquar Model no. DRS-WHT-37951 Hindware Model no. 92097 (P-21) Kohler Model no. K-17647IN-S-0
HEALTH FAUCET Supplying fitting and fixing hand shower (health faucet) ABS with rubbit cleaning system, 1.25 m long PVC flexible tube with ABS wall hook and operating knob complete in all respects. Hindware (Cat No. F160013) Jaquar(Cat No. ALD-563) or Equivalent
CONCEALED CISTERN Supplying, fitting and fixing concealed cistern with all internal fittings with CI brackets including supplying, fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified . Concealed Cistern with Control Plate (CP) from approved manufacturer. Hindware Model no. 518237 (Concealed Cistern), Hindware Concealo Neo (Aura) (Flush Plate) Roca Model no. RE890010100 (Concealed Cistern) , Roca Model no. RE890195000 (Flush plate) Kohler Model no. K-77029IN-M-NA(Concealed Cistern), Kohler Model no. K-4177IN-M-CP (Flush plate)
GRAB BAR: Providing, fitting and fixing CP Grab bar (600mm long) complete as directed and specified. Jaquar Model no. AKP-35711PS Roca Model no. RA816070165 Hindware Model no. F840012
WASH BASIN Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug, PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately) BASIN (with pedestal) Jacquar Model no. CNS-WHT-801 AND 301 Roca Model no. RS337461_ _0 Hindware Model no. 10012
WASTE PIPE Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste pipe fittings complete. Semi rigid pipe 40 mm dia
MIRROR Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
TOILET PAPER HOLDER Providing and fixing toilet paper holder : C.P. brass
URINALS Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.
URINAL PARTITION:Supply and installation of urinal partions from reputed manufacturers (sylem, meriono, green etc.) made of 12mm soild compact laminated board. The solid compact laminate (phenolic core board) is based on thermosetting resins, homogeneously reinforced with cellulose fibres and is manufactured as per IS 2046. Top surface on both sides is melamine coated which shall be scratch and impact resistant. Overall height of the partition should not be less than : 1750mm (including bottom gap of 500mm). All hardware are shall be of SS 304 grade. Including all necessary arrangements to fix the partition rigidly with the structural wall. Finished and complete as per the instruction of Engineer incharge.
BIB COCK Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore
PILLAR COCK Supplying fitting and fixing Auto Closing System pillar cock 15mm dia complete as directed and specified as follows. (pipes will be measured and paid separately). (a) Jaquar make - Model - Pressmatic PRS-031
STOP COCK 15 MM Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931 : 15 mm nominal bore
STOP COCK 20MM Providing and fixing brass stop cock of approved quality : 20 mm nominal bore
ANGLE VALVE Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931: 15mm nominal bore
BOTTLE TRAP Providing and fixing CP Brass 32 to 40 mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
FLOOR TRAP Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors 100 mm inlet and 75 mm outlet: Silver with crome finish solid construction fast drainage and automatic sealing
WASTE COUPLING FOR BASIN Providing and fixing CP Waste Coupling for wash basin of approved quality 32 mm dia of 80 mm length and 3 inch breadth
TOWEL RAIL Providing, fitting and fixing CP towel rail complete as directed and specified. (a) Jaquar make Queen’s (600mm long) (Cat. No. AQN-7711) (b) Hindware make (Cat. No. - F450024)
TOWEL RING Providing and fixing CP towel ring ovel shape minimum dimensions 21.4 x 1.5 x 14.4 Centimeters with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality , weighing not less than 88 gms.
SOAP TRAY Providing, fitting and fixing C.P. soap tray/ soap dish complete as directed and specified.
LIQUID SOAP DISPENSER Providing, fitting and fixing Liquid soap dispenser and liquid soap container complete as directed and specified. Fittings with glass bottle. Jaquar Model no. ACN-1137N or equivalent product from Hindware, Roca, Kohler.
PVC PIPES, BENDS, JUNCTIONS, TEES ETC. :Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining, fitting and fixing with clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (i) 160mm dia.
PVC PIPES, BENDS, JUNCTIONS, TEES ETC. :Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining, fitting and fixing with clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches.(ii) 110mm dia.
PVC PIPES, BENDS, JUNCTIONS, TEES ETC. :Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining, fitting and fixing with clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (iv) 75mm dia.
PVC PIPES, BENDS, JUNCTIONS, TEES ETC. :Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining, fitting and fixing with clamps etc.as necessary complete at all levels including below G.L as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 110mm dia.
PVC PIPES, BENDS, JUNCTIONS, TEES ETC. :Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining, fitting and fixing with clamps etc.as necessary complete at all levels including below G.L as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (iv) 75mm dia.
Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (i) 160mm dia.
Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (ii) 110mm dia.
Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (iv) 75 mm dia.
Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 110mm dia.
Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (iv) 75 mm dia.
Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (i) 160mm dia.
Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (ii) 110mm dia.
Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (iv) 75 mm dia.
Supplying fiting and fixing 45 degree PVC bend of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.a) In exposed surfaces or in trenches. (i) 160mm dia.
Supplying fiting and fixing 45 degree PVC bend of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.a) In exposed surfaces or in trenches. (ii) 110mm dia.
Supplying fiting and fixing 45 degree PVC bend of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.a) In exposed surfaces or in trenches. (iv) 75 mm dia.
Supplying fiting and fixing 45 degree PVC bend of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.(ii) 110mm dia.
Supplying fiting and fixing PVC Plain single tee of (Supreme/ Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches(i) 160mm dia..
Supplying fiting and fixing PVC Plain single tee of (Supreme/ Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches (ii) 110mm dia.
Supplying fiting and fixing PVC Plain single tee of (Supreme/ Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.(ii) 110mm dia.
Supplying fiting and fixing PVC Plain single tee of (Supreme/ Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages (iv) 75 mm dia.
Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (i) 160mm dia.
Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (ii) 110mm dia.
Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches (iv) 75 mm dia.
Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.(ii) 110mm dia.
Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages (iv) 75 mm dia.
Supplying fiting and fixing PVC single ‘Y’ of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches (ii) 110mm dia.
Supplying fiting and fixing PVC single ‘Y’ of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified a) In exposed surfaces or in trenches (iv) 75 mm dia.
Supplying fiting and fixing PVC single ‘Y’ of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages(ii) 110mm dia.
Supplying fiting and fixing PVC single ‘Y’ of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages (iv) 75 mm dia.
Supplying fiting and fixing PVC single ‘Y’ with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches (i) 110mm dia.
Supplying fiting and fixing PVC single ‘Y’ with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches (ii) 75 mm dia.
Supplying fiting and fixing PVC single ‘Y’ with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages (i) 110mm dia..
Supplying fiting and fixing PVC single ‘Y’ with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages (ii) 75 mm dia.
Supplying fiting and fixing PVC double ‘Y’ plain of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (ii) 75 mm dia.
Supplying fiting and fixing PVC double ‘Y’ plain of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (i) 110mm dia.
Supplying fiting and fixing PVC double ‘Y’ plain of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 75 mm dia.
Supplying fiting and fixing PVC cross ‘T’ with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (i) 110mm x110mm
Supplying fiting and fixing PVC cross ‘T’ with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified a) In exposed surfaces or in trenches.(ii) 75 mm x 75mm
Supplying fiting and fixing PVC cross ‘T’ with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.(i) 110mm x110mm
Supplying fiting and fixing PVC cross ‘T’ with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages (ii) 75 mm x 75mm
Supplying fiting and fixing PVC coupler of (Supreme/ Prince)or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (i) 110 mm dia
Supplying fiting and fixing PVC coupler of (Supreme/ Prince)or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (iii) 75 mm dia
Supplying fiting and fixing PVC coupler of (Supreme/ Prince)or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (i) 110 mm dia
Supplying fiting and fixing PVC coupler of (Supreme/ Prince)or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (iii) 75 mm dia
Supplying fiting and fixing PVC reducer of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (i) 160 mm x 110 mm
Supplying fiting and fixing PVC reducer of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (iv) 110 mm x 75mm
Supplying fiting and fixing PVC socket plug of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. in exposed surface or trences as necessary complete at all levels including below G.L. as directed and specified.(a) 110 mm
Supplying fiting and fixing PVC socket plug of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. in exposed surface or trences as necessary complete at all levels including below G.L. as directed and specified (b) 75 mm
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 15 mm nominal dia. Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm nominal dia. Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia. Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 32 mm nominal dia. Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 40 mm nominal dia. Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. : Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. : Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. : Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia. Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. : Concealed work, including cutting chases and making good the walls etc 32 mm nominal dia. Pipes.
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 25 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 20 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore.
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 40 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
RAIN WATER PIPE Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Coupler 75 mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5° 75 mm bend
Point wiring in PVC conduit, with modular type switch - Wiring for light point / fan point / exhaust fan point / call bell point ( for door call bell only ) with 1.5 Sq.mm FRLS PVC insulsted copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable etc as required. Conduit Make : Anchor / Richa or equivalent as approved. Wires : FR /FRLS - Finolex, RRKable, Anchor, Havels or equivalent as approved. Group B
Point wiring in PVC conduit, with modular type switch - Wiring for light point / fan point / exhaust fan point / call bell point ( for door call bell only ) with 1.5 Sq.mm FRLS PVC insulsted copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable etc as required. Conduit Make : Anchor / Richa or equivalent as approved. Wires : FR /FRLS - Finolex, RRKable, Anchor, Havels or equivalent as approved. Group C
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required . for staircase lighting
Wiring for 15/16A light/power plug point and AC power point installed in the guest room with 2x4 Sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit alongwith 1 No. 4 Sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required .Make : Anchor / Richa or equivalent as approved 4 Module (125mmX75mm)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required .Make : Anchor / Richa or equivalent as approved 6 Module (200mmX75mm) for Computer power points (5A 2nos Switch with 5A 2 nos. Socket ) as directed.
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required .Make : Anchor / Richa or equivalent as approved 1or 2 Module Plate back plate with frame including GI box ( for common light switch, & , AC starter )as directed
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including conections but excluding modular plate etc. as required. Make ; Havells/ Panasonic/ Schneider or equivalent as approved. 2 Nos. 5/6amp modular switch for computer points
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including conections but excluding modular plate etc. as required. Make ; Havells/ Panasonic/ Schneider or equivalent as approved. 2 nos. 5/6 amps modular socket for Computer & net point
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including conections but excluding modular plate etc. as required. Make ; Havells/ Panasonic/ Schneider or equivalent as approved. 15/16 amps modular switch as required forpowerpoint and common light switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including conections but excluding modular plate etc. as required. Make ; Havells/ Panasonic/ Schneider or equivalent as approved. 15/16 amps modular socket as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including conections but excluding modular plate etc. as required. Make ; Havells/ Panasonic/ Schneider or equivalent as approved. 5/6 amps switch and 3 pin 5/6 amp socket outlet for existing switch borad.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.FOR DOOR CALL
Circuit / submain /Light plug wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed PVC conduit as required. Wires : FR /FRLS - Finolex, RRKable, Anchor, Havels or equivalent as approved 2 x 1.5 Sq.mm + 1 x 1.5 Sq.mm earth wire
Circuit / submain /Light plug wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed PVC conduit as required. Wires : FR /FRLS - Finolex, RRKable, Anchor, Havels or equivalent as approved 2 x 2.5 Sq.mm + 1 x 2.5 Sq.mm earth wire from DB to SB for room's and as directed
Circuit / submain /Light plug wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed PVC conduit as required. Wires : FR /FRLS - Finolex, RRKable, Anchor, Havels or equivalent as approved 2 x 4 Sq.mm + 1 x4 Sq.mm earth wire from DB to Geayse power point
Circuit / submain /Light plug wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed PVC conduit as required. Wires : FR /FRLS - Finolex, RRKable, Anchor, Havels or equivalent as approved 2 x 6 Sq.mm + 1 x 6 Sq.mm earth wire for sub main to SPN DB form TPN floor maid DB
Circuit / submain /Light plug wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed PVC conduit as required. Wires : FR /FRLS - Finolex, RRKable, Anchor, Havels or equivalent as approved 3 x 6 Sq.mm + 1 x 6 Sq.mm earth wire for sub main to SPN DB form VTPN to 3TR AC
MAIN POWER DISTRIBUTION BOARD Design, manufacture, supply, installation, testing and commissioning of cubicle type panel fabricated out of 14 SWG CRCA sheet steel , floor mounted totally enclosed switch baord suitable for use of 415 volts , 3 phase, 50HZ complete with aluminium bus-bar and all accessories including supply and fixing of following incoming and outgoing switchgears. The sheet steel shall undergo minimum 7 tank treatment followed by finishing powder coating of min 60 micron thickness Incomer: FP 400 A 50 KA Ics= 100% Icu MCCB with microprocessor based release with buit in E/F Protection, extended rotary handle and spreader terminal - 2 Nos (.1 for ASEB supply and other for Generator supply having spreader link for connection to the incomming feeders ) Digital Ammeter 0-250A 3 Phase 4 Wire Accuracy Class 1 as per IEC 62053-21 Bezel dimension (W X H)=96 X 96 mm: 1 No. Digital Voltmeter - 0-500V 3 Phase 4 Wire Accuracy Class 1 as per IEC 62053-21 Bezel dimension (W X H)=96 X 96 mm : 1 Nos. CT 200/5 240V 3 Phase 4 wire Freq 50Hz+/- 5% Accuracy Class 0.5S : 1 Set SP MCB with 10KA breaking capacity of rating 6 Amp : 03 Nos RYB Indicating Lamps : 1 set Change over switch - 315 A, capacity 4P open type manual Change over switch - 1 - having inter locking arrangement with to incomming feeders. - eigher or basis 1000 A TPN AL. bus bar with coloured heat shrinkable PVC sleeve-1 Set Outgoings: 32A,3P,MCB 25KA -6 Nos. 32A,DP,MCB 25KA- 3 Nos. LED indication lamp (R Y B ) with MCB protection as necessary. Earthing Bus 40A,3P,MCCB,25KA- 6 Nos. 63A,3P,MCCB,25KA - 2 Nos. 100A,3P,MCCB,25KA - 3 Nos.
POWER DISBRIBUTION BOARD Supply, Instalation, testing and commisioning of 4way V, TPN Double Door distribution board with MCCB incomer having fully insulated busbars and shrouded nutral bars, Earth bars, reversible door fesility, wih provision for instalation os DPX3 MCCB as incomer and SP/TPMCB as out going. (Including the supply of 40A, 25KA, DPX3160 MCCB) as required for Light and sound controll system room . Make ; legrand 5077 50VTPN DB or equivalent L & T, Havells as approved.
Supplying and fixing following way, single pole and neutral ways surface/ recess mounting,MCB distribution board, 240 V, on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) as required. 8 way Double door for auditorium ceiling lighting common switch controll system, inverter system and rest rooms as directed.
Supplying and fixing following way, single pole and neutral ways surface/ recess mounting,MCB distribution board, 240 V, on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) as required. 12 way Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) as required.- for each floor power distribution for hostel and guest house rooms. 4 way (4 + 12), Double door
Supplying and fixing following rating, pole, , MCB Isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. For room DB 40 amps DP 240 V
Supplying and fixing 5 amps to 32 amps rating, 240 / 420 volts, 'B' series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 20A Single pole
Supplying and fixing 5 amps to 32 amps rating, 240 / 420 volts, 'B' series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 32A Triple pole for TPN DB incomming
Supply and installation of 25A NC modular power contactor in exixting SPN DB.
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Supply & Installation of Fans Installation, testing and commissioning of ceiling fan including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Supply and Installation of 3 blade 1400 mm sweep white SUMMER BREEZE ceiling fan. Make ; Oirent or equivalent Havells or CGL make as approved.
Supply and Installation of 3 blade 1200 sweep very silent very powerful double bearing ceiling fan. Make ; Oirent Aeroquiet or equivalent Havells or CGL make as approved.
Supplying and fixing stepped type elctronic fan regulator on the existing modular plate switch box excluding modular plate as required.
Installation of exhaust fan upto 450 mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connections, testing, commissioning etc. as required.
Supply of 300 mm high spped exhaust fan . Make ; Oirent or equivalent Havells, CGL or Panasomic make as approved.
Supply of 150mm high spped exhaust fan having automatinc lovour shutter . Make ; Oirent Ventilator HS or equivalent Havells, CGL or Panasomic make as approved.
Supply & Installation of Light /Luminaries and Fixtures Installation, testing and commissioning of prewired, flourescent fittings / all type of LED indoor ceiling fittings , complete with all accessories and tube etc. directly on ceiling/wall/ False ceiling, including connections with 1.5 sq.mm. PVC insulated, copper conductor, single core cable etc. as required.
POOJA ASSOCIATES(CONTRACT DIVN)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .