Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1ST₹1.7 CrAccepted-AOC | ₹1.7 Cr | 1ST | Accepted-AOC 1st |
| 2 | 2ND₹2.2 Cr+₹51.0 L (29.3%)Rejected-AOC | ₹2.2 Cr+₹51.0 L (29.3%) | 2ND | Rejected-AOC 2nd |
| 3 | 3RD₹2.3 Cr+₹61.2 L (35.2%)Rejected-AOC | ₹2.3 Cr+₹61.2 L (35.2%) | 3RD | Rejected-AOC 3rd |
Tender Value
₹1.6 Cr
EMD Value
₹3.3 L
Closing Date
1 Dec 2021, 3:00 pmClosed
Executive Engineer
O/O EE PHED No.1 Hisar
Mahalsara DNIT for Independent water works structures alongwith distribution system including FHTC under Jal Jeevan Mission in village Mahalsara
2021_HRY_196812_1
SE Endst. No. 16429-30 Dated 08/10/2021
Open Limited
Civil Works
Works
120 days
Hisar
Please refer Tender documents.
3 documents required · 3 mandatory
₹15,000
Yes
₹3.3 L
Yes
31 Jan 2022
22 Nov 2021
1 Dec 2021
22 Nov 2021
1 Dec 2021
22 Nov 2021
Amount
Supply & erection of Horizontal spindle split casing type puming sets of following duties directly coupled to AC squirrel cage induction type motor with 1440 RMP, 3 Phase, 50 Hz and accessories as described in Schedule No.II complete in all respect with priming arrangement with complete base frame as per IS marked Raw Water Pump Set 500 PM with 12 Mtrs. Head.
Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900 mm having following items. For Raw Water Pump Sets for 500 LPM x12 Mtr. head = 2 Nos. a) Main Switch 100 Amp. - 2 Nos. ( L&T Siemens, ABB) b) Volt meter 100 x100 mm range 0 to 500 volt 1 No.(AE/KAPPA/L&T) C) Amp. meter 100 x100 mm range 0 to 100 Amp 2 No.(AE/KAPPA/L&T) D) CT 100/3 Nos. (AE/KAPPA/L&T) E) VSS 1 No. & ASS 2 No. of approved make F) SPP 2 No. for approved make g) Motor starter, star delta 2 Nos for 500 LPM x12 Mtr. Head Motor (L&T Siemens ABB) H) Capacitor of suitable capcity 2 Nos. I) Indicating Lamp - One Set j) Change over Switch 100 Amp. =1 no.
Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900 mm and 400 mm deep having following items. For Clear Water Pump Sets for 500 LPM x40 Mtr. head = 2 Nos. a) Main Switch 100 Amp. - 2 Nos. ( L&T Siemens, ABB) b) Volt meter 100 x100 mm range 0 to 500 volt 1 No.(AE/KAPPA/L&T) C) Amp. meter 100 x100 mm range 0 to 100 Amp 2 No.(AE/KAPPA/L&T) D) CT 100/3 Nos. (AE/KAPPA/L&T) E) VSS 1 No. & ASS 2 No. of approved make F) SPP 2 No. for approved make g) Motor starter, star delta 2 Nos for 500 LPM x40 Mtr. Head Motor (L&T Siemens ABB) H) Capacitor of suitable capcity 2 Nos. I) Indicating Lamp - One Set j) Change over Switch 100 Amp. = 1 no.
Supply, erection, testing of ISI marked copper wire for 4 No. Motors with under ground system in PVC and Flexible Pipes Copper wire size 6 sq.mm 3 Core complete in all respects with accessories like thimble etc. complete in all respects. (i) 6 Sq. mm 3 core
(ii) 10 Sq. mm 3 core
Supply, erection, testing of light fitting including wire in the Pump Chamber with material upto 10 points including switch,button,plug PVC conduct pipe & copper wire etc. as per approved specifications complete in all respects.
Supply erection, testing of reputed make LED light 100 watts with fitting and accessories complete in all respects
Operation and Maintenance for the structure of 2nd water works mentioned in the DNIT ( Disinfection material supplied by the PHED ) as per schedule -IV for a period of 5 years after 12 months during defect liability period and 3 months trial run period (will be charged to the A/Mtc. estimate) complete in all respects (a) Operation and maintenance during defect liability period (Operation only) after 3 months trial run period
For 1st year operation and maintenance after defect liability period
For 2nd year operation and maintenance after defect liability period
For 3rd year operation and maintenance after defect liability period
For 4th year operation and maintenance after defect liability period
For 5th year operation and maintenance after defect liability period
Bidder Name
Amount
SUKHBIR SINGH CONT(GSTN-06AXXPS8203K1ZP)
RAM PHAL SINGH CONT(GSTN-NA)
MURARI LAL(GSTN-NA)
RAM PHAL SINGH CONT
SUKHBIR SINGH CONT
RAM PHAL SINGH CONT
SUKHBIR SINGH CONT
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .