Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 CrQualified 22 24 KRISHNA NAGAR KYDGANJ ALLAHABAD UTTAR PRADESH 211001 | PRAYAGRAJ | UTTAR PRADESH | 211001 | ₹1.9 Cr | L1 | Qualified MII |
| 2 | L2₹2.2 CrQualified 1ST FLOOR RAGHUNATH MARKET NEAR TELEPHONE EXCHANGE PATHANKOT 145001 | PATHANKOT | PUNJAB | 145001 | ₹2.2 Cr | L2 | Qualified MSE, MII, Category: General |
| 3 | L3₹2.2 CrQualified MAZZANINE FLOOR PLOT NO 17 BLOCK C PARAMOUNT TOWER C C JANAKPURI NEW DELHI WEST 110058 | WEST | DELHI | 110058 | ₹2.2 Cr | L3 | Qualified MSE, MII, Category: General |
| 4 | L4₹2.2 CrQualified 801 VENUS BENECIA PAKVAN DINING LANE OPP RAJPATH CLUB S G HIGHWAY BODAKDEV AHMEDABAD 380053 | AHMADABAD | GUJARAT | 380053 | ₹2.2 Cr | L4 | Qualified MSE, MII, Category: General |
| 5 | L5₹2.3 CrQualified KALPNA NAGAR C P COLONY MURAR GWALIOR MADHYA PRADESH 474006 UDYAM MP 20 0004701 | GWALIOR | MADHYA PRADESH | 474006 | ₹2.3 Cr | L5 | Qualified MSE, MII, Category: General |
Tender Value
₹2.2 Cr
EMD Value
₹6.7 L
Closing Date
18 Mar 2026, 1:00 pmClosed
Periodical Maintenance and operation of E and M installations CCR Room
Periodical Maintenance and operation of E and M installations in ATC
Periodical Maintenance and operation of E and M installations in Old MSSR
Periodical Maintenance and operation of E and M installations in New MSSR
Providing One no. Four Wheeler Multi Utility Vehicle
Fault locating in Underground cable using fault locating machine
Testing of Dielectric strength (BDV) of Transformer oil on yearly basis
Dehydration
Filtration of X-mer oil with High Vaccum Filtration Machine
Supply and Toping up the X-mer oil in Transformers/Servo stablizer/MOCB
Supply and replacement of oil seal of X- mer oil/servo stabilizer
Lifting and lowering of submersible pump motor
Rewinding of up to 10/15 HP submersible monoblock motor
Repairing and servicing of up to 10/15 HP submersible pump and motor
Servicing & testing of 33 kV
1250A HT panel including VCB of make - Siemens
630A HT panel including VCB of make - C&S
Breakdown visit for attending fault in VCB of Make- Siemens/C&S
Supply of spares required during the contract for 33 kV VCB of make - C&S
Supply of spares required during the contract for 33 kV VCB of make - Siemens
Servicing & testing of ACB of L&T/ABB make of 800 A to 2500 A
Breakdown visit for attending fault in ACB of Make- L&T/ABB
Supply of spares required during the contract for ACBs of make - L&T/ABB
Breakdown visit for attending fault in Solar Invertor of Make- FIMER/ABB
Supply of spares for Solar Inverters of make ABB/Fimer
Painting of electrical Runway/Taxi/Approach light fittings including base plate
Painting of tubular/rail pole height 6 mtr to 9 mtr
Spray Painting of feeder pillars
panels
distribution board etc.
Supply of Ceramic Fuse link rated 15 Amp
1000 V DC and 30kA
Supply of 48 V
0.65 Amp BLDC Fan for Solar Inverters of make - ABB/Fimer
cable jointing with heat shrinkable jointing kit for 3 x 300 sq.mm. XLPE cable
cable jointing with heat shrinkable jointing kit for 3 x 95 sq.mm. XLPE cable
cable end termination with jointing kit for 3x300 sq.mm. XLPE cable
cable end termination with jointing kit for 3 x95 sq.mm. XLPE cable
Electroplating of the reflectors of Airfield Ground Lighting
Supply of 2 way
60 Amp porcelain connector block
Providing JCB/Hydra Machine with operator for Misc. unforeseen activity.
SITC of Digital Grounding Device 240 kA
3 phase 4 wire system
Carrying out the calibration of Clinometer set of make AMA
Repairing of Earth pits by supply & fixing of MS/CI type covers
AMC of Crash rated single leaf side Automatic Sliding Gate
Supply of Gate Motor for Crash rated Automatic Sliding Gate
Supply of Gate wheel for Crash rated Automatic Sliding Gate
Supply of Photocell Eye Safety Sensor for Crash rated Automatic Sliding Gate
Supply of Hooter for Crash rated Automatic Sliding Gate
Supply of Motor control card for Crash rated Automatic Sliding Gate
Supply of Motor encoder for Crash rated Automatic Sliding Gate
Supply of Rack for Crash rated Automatic Sliding Gate
AMC of 50 KW Thyristor type NASU Make CCR
AMC of 7.5 KW Thyristor type NASU Make CCR
AMC of 4 KW Thyristor type NASU Make CCR
AMC of Airfield Lighting Control & Monitoring System (ALCMS)
Emergency visit of Service Engineer for CCR and ALCMS
Supply of CCR spares through OEM or his authorized agency
Supply of ALCMS spares through OEM or his authorized agency
DSR Works WORKS BASED ON DSR(E&M)-2025
Supply of 12 V
180 Ah lead acid batteries suitable for existing DG Sets
9042783
GEM/2026/B/7289024
Two Packet Bid
Title1,Title2,Title3,Title4,Title5,Title6,Title7,Title8,Title9,Title10,Title11,Title12,Title13,Titl
Varanasi, Uttar Pradesh
Total value wise evaluation
BOQ
8 documents required · 8 mandatory
3 yrs
₹67 L
80%
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Title1 | - | 954,739 | - |
Airports Authority of India LBSI Airport Varanasi., VARANASI, Airports Authority of India (AAI), Airports Authority of India, Ministry of Civil Aviation, (Airports Authority Of India, Lbsi Airport Varanasi.)
₹6.7 L
18 Mar 2026
25 Feb 2026
18 Mar 2026
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_9042783.pdf
GEM_BID
tenops_b1ce785b-b569-4d3b-84ad1772006362385_SM_ELECTRICAL_VARANASI.pdf
OTHER
list-of-categories-where-trials-are-allowed_1712126171.pdf
OTHER
gtc.pdf
OTHER
scc_2026-02-25-12-26-42_e7a29efb6358067fc549bc8ad204fe95.pdf
BOQ
boq_item_sample_file_2026-02-25-12-26-42_135745edaef2956aa1d269b0c7bced8b.csv.pdf
BOQ
tenops_b1ce785b-b569-4d3b-84ad1772006362385_SM_ELECTRICAL_VARANASI.pdf
GEM_OTHER • 4.07 MB
list-of-categories-where-trials-are-allowed_1712126171.pdf
GEM_OTHER • 0.52 MB
gtc.pdf
GEM_OTHER • 0.70 MB
Download all tender documents and submit your bid