Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.9 LAccepted-AOC 15A 9 CHOWBHAGA ROAD KOLKATA KOLKATA 700039 | KOLKATA | WEST BENGAL | 700039 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹27.4 L+₹7.4 L (36.6%)Rejected-AOC | L2 | Rejected-AOC OTHER THAN LOWEST |
Tender Value
Refer Docs
EMD Value
₹55,500
Closing Date
19 Jan 2021, 6:00 pmClosed
GE Army Dhar Road Udhampur
GE Army Dhar Road Udhampur
Repair, maint of Window/Split ACs, Refrigerator, Water Cooler, ROs, Ceiling Fan and Geyser etc and other connected misc works under GE Army Dhar Road Udhampur
2020_MES_405331_1
8066/NIT-61/2020-21
Open Tender
Miscellaneous Works
Item Rate
270 days
GE Army Dhar Road Udhampur
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
Yes
GE Army Dhar Road Udhampur
₹55,500
Yes
8 Mar 2021
21 Dec 2020
21 Jan 2021
21 Dec 2020
19 Jan 2021
5 Jan 2021
21 Dec 2020 - 4 Jan 2021
Amount
Disconnection of suction and discharge line connection of sealed unit and taking out the defective sealed unit compressor from window type AC/split AC of any make replacing the defective compressor with any repaired old serviceable compressor , refixing the compressor in the original position of window/split type AC making all existing connection complete all as directed for 1.5/2.0 ton Air conditioners. ( Note :- Charging of Gas R-22 shall be measured & paid separately under relevent item)
Supply and fixing in replacement of compressor hermetically sealed type equipped with suitable rated capacity electric motor and over load protection and shall confirm to IS 10617, making all existing connection complete all as directed for 1.5 ton Window type Air conditioners all as directed .
All as per item Ser No 2 above but 2 Ton Capacity
Supply and fixing in replacement of compressor hermetically sealed type equipped with suitable rated capacity electric motor and over load protection and shall confirm to IS 10617, making all existing connection complete all as directed for 1.5 ton Split type Air conditioners all as directed .
All as per item Ser No 4 above but 2 Ton Capacity
Charging of refrigerant Gas F 22/ R-134A in the sealed system of of Window type Air conditioners/split type ACs 1.5 /2Ton capacity after checking leakage /pressure vacumising flushing the sealed unit in satisfactory working condition all as specified.
Taking down for servicing of window/Split AC 1.5 ton/2.0 Ton capacity and cleaning /serviceing of AC, overhauling of cooling coil, air filters/plasma filters etc (indoor ) condenssors , fan motors etc (outdoor unit) with vacum cleaner or other cleaning solution incl checking the servicivelty for other components working condition all as specified and directed Note : Replacement of defective parts/ spares will be measured and paid seperatly under relevent items and labour charges for fixing of defective spares shall deemed to be included in unit rate quoted.
Supply only the following defective spares parts of split /window AC unit of 1.5/2.00 TR against above item ;-
Blower motor 1/6 HP with base/ rubber bush complete Make AUE/GE
Condensor fan motor 1/5 HP make AUE/GE as per sample.
Condensor fan blade.
Drum type blower fan PVC type
Running capacitor 36 mfd make EPCOS.
Running capacitor 45 mfd make EPCOS.
Starting capacitor 100 to 120 mf Make : "TESLA"
Thermostate make Indfoss.
Starting relay make Ranutrol.
Cooling coil assembly.
Condensor coil assembly.
Wiring kit.
Capacitor 6 mfd
Blower motor 1/30 HP for in door unit split type AC.
Main printing circuit board (PCB) with electric accessores and sensors suitable for split AC cap 1.5/2 TR
M&L for detecting the leakage of gas of split/window type AC 1.5/2 TR from any location and rectified /stoped the leakage by gas weilding or any other materials and made it functioning as directed .
WATER COOLERS Disconnection of the compressor from suction and discharge line and taking out the sealed unit compressor from water cooler of any make ,replacing the defective compressor with repaired old serviceable compressor from any of the authorised repair workshop /manufacturer, refixing the repaired compressor in the original position of the water cooler making all existing connection for for any capacitiesas directed
Supply and fix in replacement of new compressor hermetically sealed type with suitable rated capacity electric motor and shall be equipped with over load protection, 230 volt, 50 HZ, single phase suitable for water cooler any capacity incl warrenty as per menufacturers
M&L for gas refrigent F-22/R-134A in the sealed system of water cooler any make and capacity after checking the leakage / pressure vacuminising flushing the sealed system including replacement of capilary Tube, Gas filter all as directed.
Dismantling and supply and fixing the blower moter of water cooler 1/32 HP, 1250 RPM capacity, 230 volts single phase and taking out burnt out copper winding wire from moter and M&L for rewinding the electric motor with super enameled copper winding wire of same size and gauge including insulation material, varnish and reassemble and refixing the motor complete including replacement of unserviceable spares all as directed.
Disconnection from mains for servicing of water cooler of cap upto 180 Ltrs and cleaning /serviceing , overhauling of cooling coil with vacum cleaner or other cleaning solution incl checking the servicivelty for other components working condition all as specified and directed Note : Replacement of defective parts/ spares will be measured and paid seperatly under relevent items and labour charges for fixing of defective spares shall deemed to be included in unit rate quoted.
Supply only the following defective spares parts of water cooler any cap against above item ;-
Supply of thermostat switch for water cooler.
Supply of starting relay for water cooler.
Supply of starting capacitor 40-60 mfd ,230 volt ,50Hz, confirming to IS 2993 for water cooler.
Supply of starting capacitor capacity 60-80 MFD.
Supply of Running capacitor 15 Mfd , 415volt,50Hz .
Supply of Running capacitor 10 Mfd , 415volt,50Hz .
Supply of Running capacitor 6 Mfd , 415volt,50Hz .
Supply of Running capacitor 36 Mfd , 415volt,50Hz .
Supply PVC float valve with rod and plastic ball suitable for 1/2" bore of watercooler for blue star fittings
Supply of over load protector (OLP) for water cooler of any capacity complete all as specified and directed.
Supply of self closing Push cock 15mm bore chromium plated brass heavy duty longthread ( As per sample).
Supply of aluminium blade for blower motor of water cooler 40/60/120 Ltrs
Supply blower motor 1/32 HP 230 volt suitable for water cooler complete with base frame/and rubber bush make AUE/GE.
Supply of water tank gasket for water cooler 40/80 ltr cap.
Supply of wiring kit complete for water cooler.
Supply of PVC pipe low density 25 mm dia flexible pipe with two clamp complete & all as specified.
Supply and fixing in replacement PVC connection pipe with brass union of 15 mm bore in both end suitable for water cooler connection of length not less than 600 mm long.
Supply and fixing PVC pipe flexible type 40 mm dia for drain system and connection all as directed.
Refrigerator /Deep Freezer Disconnection from mains for servicing of Refrigerator/Deep freezer of cap 165 to 310 Ltrs and cleaning /serviceing , overhauling of cooling coil with vacum cleaner or other cleaning solution incl checking the servicivelty for other components working condition all as specified and directed Note : Replacement of defective parts/ spares will be measured and paid seperatly under relevent items and labour charges for fixing of defective spares shall deemed to be included in unit rate quoted.
Supply only the following defective spares parts of Refrigerator/ Deep freezer any cap against above item ;-
Supply of thermostat switch
Supply of starting relay
Supply of starting capacitor 40-60 mfd ,230 volt ,50Hz, confirming to IS 2993 for water cooler.
Supply of Running capacitor 15 Mfd , 415volt,50Hz .
Copper filter single capillary pencile type
Disconnection of the compressor from suction and discharge line and taking out the sealed unit compressor from water cooler of any make ,replacing the defective compressor with repaired old serviceable compressor from any of the authorised repair workshop /manufacturer, refixing the repaired compressor in the original position of the Refrigerator /Deep freezer making all existing connection for any capacities.
Supply and fix in replacement of new compressor hermetically sealed type with suitable rated capacity refrigerator of any make and type and providing and fixing new compressor suitable for 165 to 310 ltr refrigerator and testing the same with gurantee as per manufacturers incl charging of the refrigent gas F-12m R-134 A and all other copper tubes capillary and filter and put in working condition all as directed
M&L for gas refrigent F-22/R-134A in the sealed system of Refrigerator / Deep frezeer any make and capacity after checking the leakage / pressure vacuminising flushing the sealed system including replacement of capilary Tube, Gas filter all as directed.
RO water purification Repair and maint of RO water purification system of any make complete with replacement of unserviceable parts and making the system serviceablr as per manufacturers accessories Note :- New parts will be measured and paid seperatly under respective item under supply only . labour charge will be deemed in quoted rate .
Supply only micro spun 20 Make Renuka RWI 107
supply only CTO 20 Make Renuka RWI 109
Supply only membrane housing 50 Make Renuka RWI 125
Supply only UV system 100 Make Renuka RWI 137
Supply only flow restrictor adjuster Make Renuka RWI 134
Supply only micronic membrane 50 Make Renuka RWI 127
Supply only connecting pipe PVC
Supply only sedimentation filter
Supply only Motor and pump for RO
VOLATAGE STABLIZER Dismantling of voltage stabilizer 5/4 KVA capacity for repairs and re-fixing back to its original position after repair, cleaning, testing, complete all as directed ( Parts to be replaced will be measured and paid separately under relevant items ).
Supply only the following parts for voltage stabilizer 4/5 KVA capacity :-
Main printed circuit board
Auxilary printed board
Main transformer
Auxilary transformer
High/low cut off relay
Time delay relay
Volt meter 0-300 volt range AC round/square shape,
Push button/switch for volt meter.
Indicator lamp.
Supply and fixing the voltage corrector of 4 KVA with over load and time delay relay with correction from 170 to 250 with out put voltage 230 volts all as rquired and directed suitable for fixing on wall all as directed Make Voline ,logicstat, blue bird or as approved
M&L for AC Contactor AC 3 Phase 415 volts for 15 TR AC starter complete including taking down old unser contactor all as directd Make: C&S electric Ltd Cat No 1D4011M5 or eqvt Havells/L&T/Seimens as exist at site
M & L for tracing gas leakage in system with nitrogen gas in package type AC of 3x5 TR capacity plant at Dhar Road including and making system leak proof with gas welding complete all as specified and directed.
M & L for tracing gas leakage in system with nitrogen gas in central AC Plant 3x 15 TR capacity plant at Dhar Road including and making system leak proof with gas welding complete all as specified and directed.
M & L for tracing gas leakage in system with nitrogen gas in central AC Plant 2x 5 TR capacity plant at Dhar Road including and making system leak proof with gas welding complete all as specified and directed.
M & L for Refrigerant gas R-407 complete
M&L for Heat sensor unit with suitable sensor lead fron chillar pipe to control panel all as specified and directected.
Replacement of thermostate including heating strip of suitable capacity 230 volt, 50 HZ, AC strip as existing in AC plant 5 TR at Dhar Road
Supply, installation, testing and commissioning of 3 way mixing/ diverting valve of size 65 mm dia with proportional cooling only thermostats for the Air Handling Units complete with required controls wiring/ installation kit etc. complete all as specified & directed.
Ceiling & Exhaust Fan Taking down and refixing after recify the defects carefully of ceiling fan any size and any sweep including dismantling of blades, down rods fan for recognize defects at site or deposit to store complete all as directed by Engineer-in-Charge.
Taking down and refixing after recify the defects carefully of exhaust fan any size and any sweep including dismantling of blades, for recognize defects at site or deposit to store complete all as directed by Engineer-in-Charge.
Labour work for overhauling of ceiling fan any Make and sweep including dismantling, cleaning internally and externally, oiling, greasing, checking of electric connections, replacement of worn out check nuts, split pins, nuts, bolts and washers, sockets rebber real, clamps and minor repairing works and items etc. reassembling and testing on completion all as directed. Note :- Winding works and connecting items will be measured and paid seperatly.
All as specified in item No.37 here-in-before but for exhaust fan/wall fan/fresh air fan etc of any Make and any size.
Painting of ceiling fan of any 1200/1400 mm size sweep including blades and canopies with white enameled approved spray paints one coat after cleaning dust etc and Marking of MES No ceiling fan such as MES No, and height of letter 2.5 cm in figures including sign writing with black enameled paints all as directed
Painting of Exhaust fan of any size sweep including blades and canopies with white enameled approved spray paints one coat after cleaning dust etc and Marking of MES No Exhaust fan such as MES No, and height of letter 2.5 cm in figures including sign writing with black enameled paints all as directed
Removing the burnt copper winding of ceiling fan ,cleaning to cores and rewinding of ceiling fans with copper enameled wire of suitable size including film paper, sleaving and varnishing , 56” (1400mm) complete any make any type as directed by Engr-in- Charge .
All as per item No 41 above but 48”(1200 mm) sweep any make and any size
All as per item No 41 above but exhaust fan 18” sweep 450mm complete any make all as directed by Engr-in- Charge
All as per item No 41 above but exhaust fan 12” sweep(300 mm) dia complete
All as per item No 41 above but exhaust fan/ fresh air fan 9" (250mm) dia complete.
All as per item No 41 above but wall fan 12'' /15" (300 mm/350 mm) dia complete
supply of ball bearing suitable size where required and as directed Make SKF/NBC :-
supply of condensor 2.5 MFD where required and directed for ceiling fan
Supply of condensor 4.00 MFD for exhaust fan where reqd and directed
Supply and fixing in replacement of Mirror optic fitting by recess mounted mirror optic LED luminaire fitting not less than 100 lumen/watt , 36 watt, dimention 600mm x 600mm fitting for grid type ceiling including control driver and other accessories complete all as specified and directed. cat no LCTLRNE-30-FO-CDL of make CROMPTON OR EQUIVALENTS or Philips/wipro/Havells
S&F Wall mounted LED batten 18/20 Watt with 01 No LED tube rod, extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver including dismantling taking down unsv FTL fitting T8 type any type complete all as specified and directed. Make: Crompton Cat Part No LDL-20-CDL or equivalent in Philips/WIPRO
DESERT COOLER Supply and fixing in replacement of PVC flexible pipe15 mm dia suitable for water distribution system of desert cooler of any size/capacity including elbow and water distributer 3 way as required .
Supply and fixing of submersible pumps 230 volts, single phase for lifting of water as required head and as directed at site in replacement of old worn out unserviceable vertical pump /submerseable pump.
Supply and fixing Exhaust fan 450 mm sweep, 900 RPM , 230 Volt AC in replacement of old unserviceable ,worn outexhaust fan complete and fixing in desert cooler as directed. Make :- CG, Bajaj, Havells,Usha
Supply and fixing in replacement of front grill plastic of the desert cooler with necessary nut, bolts, and washer etc, all as directed at site
Supply and fixing in replacement of loose wood wool padding of desert cooler side shutters in wire net all as directed.
supply and fixing in replacement side shutter for desert cooler of 22 gauge PGI sheets grill type all as directed.
M&L for making water tank and body (Except side shutters)for desert cooler with 22 gauge PGI sheet of suitable size including side supports of deert cooler , front panel for fixing of Exhaust/ Kit fan and top cover as per sample and directed including dismantling of old unserviceable water tank and body fitted with old desert cooler.
Geyser (Water Heater) Repair and maint of geyser 25/50 ltrs capacity including checking /inspection of functionalty of element, thermostate, leakage of water, assembly, inner tank etc including taking down and re-fixing of geyser after defect rectification all as specified and directed.
Supply and fixed heating element 1500 watt push/screw/ triangular type suitable for 25/50 ltrs capacity geysers ISI marked complete all as directed by Engr-in-Charge.
Supply and fixed heating element 2000 watt push/screw/ triangular/spiral alongwith magnesium anode for extra protection of any type, any make geyser type suitable for 25/50 ltrs capacity geysers ISI marked complete all as directed by Engr-in-Charge.
Supply and fixed thermostate switch suitable for 25/50 Ltrs capacity geyser of any make/ type with temperature range adjustable from 25 to 90 degree centigrade superior quality 20 Amp rating 220 volt AC supply complete.
S&F thermostate switch cat No WY 75-652-11A4 (0916), AC 250 Volt 16 Amp, 50 Hz complete with fitting for Bajaj Cantela 25 Ltr Geyser all as specified and directed at site.
Supply and fixed PVC flexible connection with two brass adopter as per existing samples/ suitable of carrying hot water fixed one end at geyser inlet / outlet water supply point complete .
S&F safety valve multi functional 4 in 1 for protection against dry heating, over heating and over pressure Make Bajaj Cat Part No 0916 for Bajaj Cantela 25 Ltr Geyser all as specified and directed at site
Supply and fixing indicator lamp suitable for 220 volts AC supply circular/ rectangular (green/ red) as per sample with neon lamp of superior quality complete .
Painting of Geyser of any size 25/50 Ltrs with existing colour enameled approved spray paints one coat after cleaning dust etc all as directed
Supply and fixing geyser 25 Ltrs inner tank copper moulded alongwith titanium armour technology all connection complete all as specified and directed
Supply and fixing geyser 50 Ltrs inner tank copper moulded alongwith all connection complete all as specified and directed
Supply and fixing geyser assembly any type including packing and gasket materials as per existing any type 25/50 Ltrs Geyser all as specified and directed.
Replacement of old unserv water heater storage type 25 Ltr capacity (5 Star BEE rating) including PVC connections 15mm dia for hot and cold water and fixing on existing wall complete including deposit to MES store for old unserviceable water heater all as specified and directed. Make : Havells / Crompton Greaves (CG) / Bajaj
Solar Water Heater Supply and fixing Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron/GI pipe 15 mm dia all as specified and directed
Supply and lay pipe galvanized, “Medium class”, including fittings 15 mm (1/2”) dia ,with all fitting incl connection with existing pipe line, laid in trenches/wall all as specified and directed.
Repairing of Solar Water heating system (Tubelor rod collector) based on direct transfering of heat thermosyphon cirulation, non pressurised system of capacity 500 LPD with suitable electric backup including accessories complete all as specified and directed
Repairing of Solar Water heating system (Tubelor rod collector) based on direct transfering of heat thermosyphon cirulation, non pressurised system of capacity 100 to 200 LPD with suitable electric backup including accessories complete all as specified and directed
Replaement of Tubelor rod collector based on direct transfering of heat for 500 LPD solar water heater complete all as specified and directed
Replaement of Tubelor rod collector based on direct transfering of heat for 100 to 200 LPD solar water heater complete all as specified and directed
Replacement of Thermostate for 100 to 500 LPD solar water heater 2000 watt, 35 to 75 deg C, 230 volt single phase complete all as specified and directed
Replaement of Heating element 2000 watt for 100 to 500 LPD solar water heater complete all as specified and directed
Replacement of Cable twin core 16 Sqmm unarmured,PVC insulated, aluminium conductor 230 volt, single phase all as specified and directed.
GURU KRIPA ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .