Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.3 LAccepted-Finance | L1 | Accepted-Finance resposive | |
| 2 | L2₹17.9 L+₹63,300 (3.66%)Accepted-Finance | L2 | Accepted-Finance responsive | |
| 3 | L3₹18.3 L+₹99,590 (5.76%)Accepted-Finance | L3 | Accepted-Finance resposive |
Tender Value
₹18.3 L
EMD Value
₹36,600
Closing Date
21 Jul 2022, 3:00 pmClosed
Executive Engineer Electric Division Sumbal
Electric Division Sumbal
Contract for Augmentation of UpGradation Installation of transformers (02Nos) LT Poles at Pahlipora A BWO Creation of 100 kVA Sub-Station at Pahlipora A near Grave Yard Safapora BWO Creation of 100 kVA Sub-Station at Patipora Pahlipora Safapora B
2022_PDD_172587_1
EDS- OF -2022-23
Open Tender
Electrical Works
Item Rate
safapora
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
Yes
Executive Engineer Electric Division Sumbal
₹36,600
Yes
30 Jul 2022
6 Jun 2022
22 Jul 2022
6 Jun 2022
21 Jul 2022
6 Jun 2022
Amount
Supply ,transportation ,installation, testing and Commissioning of 100 KVA Step-down transformer 11/0.440 KV) Level -2 fitted with Silica Gel Breather,oil filled and tested,complete in all respects as per latest specifications and drawing adopted/approved by the department.
Supply ,transportation ,insurance, installation, testing and Commissioning of 200 KVA Level-2 (Al. Wound) Step-down transformer 11/0.440 KV) fitted with Silica Gel Breather,oil filled and tested,complete in all respects as per latest specifications and drawing adopted/approved by the department.
Earthing of Sub-Station-Excavation of earth Pit f 650 mm dia.& depth 3000 mm,Installation of earthing Pipe of 40mm nominal bore and 4mm wall thickness and length 2.5 m long as per IS-1239.GI Strip for neutral earthing of size 25mmX 3mm for connection of X-mer body ,G.O Set & LA as per IS-629/85,GI Nuts and Bolts refilled with earth enhancement materials & earth Chamber made of Brick massonary with RCC Slab Cover.
Providing ,transportation ,installation, testing and Commissioning of GI Channel Cross arms (100X50X50X6 mm) and (75X40X40X6 mm),transformer Belting, Clamps etc. fabricated out of Galvanised steel of different sizes to be fixed with GI Nuts and bolts and washers.(as per the latest specification and drawing approved by the department).
Providing and installation, & Fixing of 11 KV G.O Switch 3Ph ,3-Pole of Capacity 200 A (Vertical type ) with arrangements for pad locks and operating rod.The operating rod should be G.I Pipe (B Class) of 25 mm dia of requisite length.
Providing , and Installation of gapless Surge Arrestor,9kV,10kV,LA with (Polymer ) housing ,Station Type.
Providing and installation of 11 kV Horn,Gap Fuse 3-Phase 100 A.
Providing, and fixing of un -armoured PVC Cable 185 mmSq. Including Al. Thimbles and SL Clamps
LT Distribution box for 100 kVA DTR with MCCB for incommer and SFU'S for outgoing circuit.
LT Distribution box for 200 kVA DTR with MCCB for incommer and SFU'S for outgoing circuit.
Providing & fixing of 11 kV Polymeric composite Disc insulator 12 kV,minimum failing load of 45 kN,lighting impulse of 75 kV positive & 80 kV negative and with creepage distance of 320 mm.
Providing, ,transportation ,installation, testing and Commissioning of ST Poles 9 Mtr long (410-SP-33) including excavation of pit and back filling soil & consolidating each deposit layer of by ramming and watering etc. (as per the latest specification and drawing approved by the department).
Providing, ,transportation ,installation, testing and Commissioning of ST Poles 8 Mtr long (410-SP-15) including excavation of pit and back filling soil & consolidating each deposit layer of by ramming and watering etc. (as per the latest specification and drawing approved by the department).
G.I Barbed wire for Anti Climbing devices with Clamps as per REC Standard.
Danger Plates with Clamps
Providing ,transportation ,installation, testing and Commissioning of V -Shaped GI Cross Arms (75X40X6 mm) with top Bracket including Clamps, GI Nuts and Bolts.
Providing, transportation and fixing of 11 KV Pin insulators with G.I Pins (as per the latest specification and drawing approved by the department).
Providing, transportation and fixing of GI Clamps with LT Shackle insulators including nuts and bolts.(GI Back Clamps to be fixed with out drilling/punching of poles).
Providing and Laying, stringing of overhead 0.05 ACSR conductor (Rabbit) on cross arms through insulators including binding and twisting with soft aluminium wire both side of insulator complete in all respects (as per the latest specification and drawing approved by the department).
Providing and fixing of HT pole Earthing Complete by GI Rod 20mm 2.5 mtr long through GI Strip
Providing and fixing of LT pole GI spiral earthing 125 SWG Complete (as per latest specifications and drawing adopted /approved by the department.
Painting of pole with one coat of Red-Oxide and Two coats of Aluminium paint (including cost of paint)
Supply and laying of Cement Bottoming 1:2:4 mix as per REC standards 0.5 cum/pole including muffing 20 cm above ground level plaster and curing for 9 Mtr ST poles respectively (the leftover pit after concreting to be filled with soil and boulders).
Supply and laying of Cement Bottoming 1:2:4 mix as per REC standards 0 .45 cum/pole including muffing 20 cm above ground level plaster and curing for 8 Mtr ST poles respectively (the leftover pit after concreting to be filled with soil and boulders).
M/s Bilal Electricals
SHAH ELECTRICALS
tech_eval.pdf
fin_eval.pdf
finance_407783.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .