Garrison Engineer
Garrison Engineer AF Bhisiana Bathinda Punjab PIN 151201
COMPREHENSIVE MAINT OF CERTAIN E/M WORKS AND CONVENTIONAL/CHEMICAL EARTHING SYSTEM AT TECHNICAL AREA AT BHISIANA UNDER GE (AF) BHISIANA
2026_MES_786180_1
GE/BHI/TOKEN-47/2026-27
Open Tender
Civil Works
Item Rate
244 days
Bhisiana
As per NIT
7 documents required · 7 mandatory
₹500
GE (AF) Bhisiana
₹64,000
Yes
GE AF Bhisiana
25 Aug 2026
25 Aug 2026
18 Sept 2026
25 Aug 2026
16 Sept 2026
9 Sept 2026
25 Aug 2026 - 4 Sept 2026
31 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying and drawing in replacement 1.5 sqmm nominal cross-sectional area, single-core, multi-strand copper conductor, FRLSH PVC insulated, unsheathed cable (any colour as directed or as per existing), 1100 V grade, conforming to IS 694:2010, through the existing conduit system/casing caping, including careful withdrawal of the existing cable and drawing in the new cable without damaging the existing serviceable wiring and conduit/ casing caping. The work shall include wiring from the distribution board (DB) to switchboards and from switchboards to light points, fan points, exhaust fan points, socket outlets, sub main wiring or other connected points, as per the existing wiring layout, including all necessary terminations, testing and commissioning. The item includes all labour, tools and plant, consumables and incidental works required for satisfactory completion, complete in all respects as specified and directed by the Engineer-in-Charge.
Note: The cable shall be measured on the basis of the actual running length drawn and fixed at site, and payment shall be made in Running Metres (RM) only. | 30 | RM | - | - |
| 2 | Supplying and drawing in replacement 2.5 sqmm nominal cross-sectional area, single-core, multi-strand copper conductor, FRLSH PVC insulated, unsheathed cable (any colour as directed or as per existing), 1100 V grade, conforming to IS 694:2010, through the existing conduit system/ casing caping, including careful withdrawal of the existing cable and drawing in the new cable without damaging the existing serviceable wiring and conduit/ casing caping. The work shall include wiring from the distribution board (DB) to switchboards and from switchboards to power point socket outlets, sub main wiring or other connected points, as per the existing wiring layout, including all necessary terminations, testing and commissioning. The item includes all labour, tools and plant, consumables and incidental works required for satisfactory completion, complete in all respects as specified and directed by the Engineer-in-Charge.
Note: The cable shall be measured on the basis of the actual running length drawn and fixed at site, and payment shall be made in Running Metres (RM) only. | 30 | RM | - | - |
| 3 | Supplying and drawing in replacement 4 sqmm nominal cross-sectional area, single-core, multi-strand copper conductor, FRLSH PVC insulated, unsheathed cable (any colour as directed or as per existing), 1100 V grade, conforming to IS 694:2010, through the existing conduit system/ casing caping, including careful withdrawal of the existing cable and drawing in the new cable without damaging the existing serviceable wiring and conduit/ casing caping. The work shall include wiring from the distribution board (DB) to switchboards and from switchboards to geyser point, AC point, power point socket outlets, sub main wiring or other connected points, as per the existing wiring layout, including all necessary terminations, testing and commissioning. The item includes all labour, tools and plant, consumables and incidental works required for satisfactory completion, complete in all respects as specified and directed by the Engineer-in-Charge.
Note: The cable shall be measured on the basis of the actual running length drawn and fixed at site, and payment shall be made in Running Metres (RM) only. | 30 | RM | - | - |
| 4 | Supplying and drawing in replacement 6 sqmm nominal cross-sectional area, single-core, multi-strand copper conductor, FRLSH PVC insulated, unsheathed cable (any colour as directed or as per existing), 1100 V grade, conforming to IS 694:2010, through the existing conduit system/ casing caping, including careful withdrawal of the existing cable and drawing in the new cable without damaging the existing serviceable wiring and conduit/ casing caping. The work shall include wiring from the distribution board (DB) to switchboards and from switchboards to geyser point, AC point, power point socket outlets, sub main wiring or other connected points, as per the existing wiring layout, including all necessary terminations, testing and commissioning. The item includes all labour, tools and plant, consumables and incidental works required for satisfactory completion, complete in all respects as specified and directed by the Engineer-in-Charge.
Note: The cable shall be measured on the basis of the actual running length drawn and fixed at site, and payment shall be made in Running Metres (RM) only. | 20 | RM | - | - |
| 5 | Material and labour for replacement of existing PVC conduit with new medium mechanical stress PVC conduit conforming to IS 9537 (Part-III): 1983, of suitable nominal diameter 20 mm or 25 mm, as required at site, complete with all accessories including bends, elbows, couplers, inspection/junction boxes, saddles, spacer bar saddles, clips, clip clamps and all other necessary fittings. The work shall include cutting chases in walls, carefully removing the existing conduit, laying and fixing the new conduit, re-drawing the existing serviceable wiring, making all necessary joints and connections, and making good the disturbed surfaces with cement mortar (1:3) to match the existing finish. The item includes all labour, tools and plant, consumables and incidental works required for satisfactory completion, complete in all respects as specified and directed by the Engineer-in-Charge.
Note: (i) The quoted rate shall be deemed to include careful withdrawal and re-drawing of the existing serviceable wires through the new conduit. However, if any existing wire is found unserviceable during execution and requires replacement, the same shall be measured and paid for separately under the respective BOQ item.
(ii) Measurement shall be made for the actual running length of conduit replaced, and payment shall be made in Running Metres (RM) of conduit only. The quoted rate shall be deemed to include withdrawal and re-drawing of the existing serviceable wires through the replaced conduit, and no extra payment shall be admissible on this account.
(iii) This item shall be executed only where replacement of one or two wires out of the existing wires already drawn through the conduit is required, but the existing PVC conduit is blocked, crushed or otherwise rendered unusable due to masonry work, making withdrawal and re-drawing of the wires through the existing conduit impracticable. | 60 | RM | - | - |
| 6 | Supply and fixing in replacement of non-modular switch, 6 Amps, one-way, matching the existing make, model, size and mounting arrangement, or equivalent as approved by the Engineer-in-Charge, suitable for accommodating in the existing switch box and sheet cut-out without any modification. including necessary screws and fixing accessories, making all electrical connections, testing for proper operation and commissioning, complete in all respects as specified and directed by the Engineer-in-Charge. | 80 | Each | - | - |
| 7 | Supply and fixing in replacement of non-modular switch, 16 Amps, one-way, matching the existing make, model, size and mounting arrangement, or equivalent as approved by the Engineer-in-Charge, suitable for accommodating in the existing switch box and sheet cut-out without any modification. including necessary screws and fixing accessories, making all electrical connections, testing for proper operation and commissioning, complete in all respects as specified and directed by the Engineer-in-Charge. | 50 | Each | - | - |
| 8 | Supply and fixing in replacement of non-modular switch, 6 Amps, two-way, matching the existing make, model, size and mounting arrangement, or equivalent as approved by the Engineer-in-Charge, suitable for accommodating in the existing switch box and sheet cut-out without any modification. including necessary screws and fixing accessories, making all electrical connections, testing for proper operation and commissioning, complete in all respects as specified and directed by the Engineer-in-Charge. | 2 | Each | - | - |
| 9 | Supply and fixing in replacement of non-modular Bell push, flush type, 6 Amps, matching the existing make, model, size and mounting arrangement, or equivalent as approved by the Engineer-in-Charge, suitable for accommodating in the existing switch box and sheet cut-out without any modification. including necessary screws and fixing accessories, making all electrical connections, testing for proper operation and commissioning, complete in all respects as specified and directed by the Engineer-in-Charge. | 10 | Each | - | - |
| 10 | Supply and fixing in replacement of non-modular Socket outlet multipurpose type 6 Amp, matching the existing make, model, size and mounting arrangement, or equivalent as approved by the Engineer-in-Charge, suitable for accommodating in the existing switch box and sheet cut-out without any modification. including necessary screws and fixing accessories, making all electrical connections, testing for proper operation and commissioning, complete in all respects as specified and directed by the Engineer-in-Charge. | 60 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.08 MB
TenderDocToken47.pdf
Tender Documents • 0.63 MB
BOQ_880992.xls
BOQ • 0.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .