Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.4 LAccepted-AOC DSS 194 POCKET A SEC 14 125001 | HISAR | HARYANA | 125001 | L1 | Accepted-AOC accepted | |
| 2 | L2₹13.3 L+₹2.9 L (27.5%)Rejected-AOC | L2 | Rejected-AOC rejected | |
| 3 | Rejected-Technical 209 210 AGGARWAL TOWER PLOT NO 2 SECTOR 5 ROHINI NORTH WEST DELHI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | - | Rejected-Technical rejected |
Tender Value
₹12.2 L
EMD Value
₹24,380
Closing Date
17 Nov 2021, 5:00 pmClosed
Executive Engineer
Electrical Division PWD BnR Br. Rohtak
Construction of Government I.T.I. Khera Khemawati at Safidon (Jind) (Pdg. EPBAX/LAN/P.A./Fire Alarm system only).
2021_HRY_194084_1
PWD/Electrical/183298
Open Tender
Electrical Works
Item-rate/Agreement basic
60 days
Jind
Please refer to tender documents as per DNIT conditions.
3 documents required · 3 mandatory
₹1,000
₹24,380
Yes
18 Apr 2022
28 Oct 2021
18 Nov 2021
28 Oct 2021
17 Nov 2021
28 Oct 2021
Amount
EPBAX SYSTEM
SITC IP-PBX with Configuration, User expandable up to 256 Ports Lines with Following Configuration: - 42 Analog Users 8 digital users System should support ISDN PRI - 01 04 Analog Trunks 01 Operator Console. a) Remote Maintenance Facility b) Web Based Managment Software c) Call Accounting Software-01 d) DISA & DOSA Facility e) Wall / Rack Mountable System f) Call Control Server / Applicatation should be equipped with Intel / Pentium Based Processer including cost of all material and Labour required to complete the job in all respect upto the entire satisfacation of Engineer in Charge of the work Make : Avaya / Alcatel Lucent / Siemens / Coral
SITC Digital Phones including cost of all materical and Labour required to complete the job in all respect upto the entire satisfacation of Enigeer in charge of the work Make Alcatel Lucent/Avaya/Siemens.
SITC Analog Phones including cost of all materical and Labour required to complete the job in all respect upto the entire satisfacation of Enigeer in charge of the work Make Alcatel Lucent/ Beetal M71
SITC Single Telephone I/O including face plate complete in all respect Make: Dlink/AMP
SITC of MDF unit with Tag blocks in a fabricated CRCA powder coated junction box with pad-lock, provision for earthing, inclusive of IPM modules and GDT etc. for overcurrent and overvoltage protection. Make: Krone or equivalent.
i) 20 pair MDF unit
ii) 100 pair MDF unit
SITC of multicore telephone cable conductor size 0.51 mm bright annealed copper conductor PVC insulated and shealed in existing pipe/Channel and making necessary connection complete in all respect.
i) 2 pair telephone wire
ii) 20 pair telephone wire
LAN SYSTEM
SITC UTP Cat-6 information outlet complete in all respect up to the entire satisfaction of Engineer-in-Charge of the work Make: AMP / Schneider / D-link.
SITC Face plate (Single / Dual) complete in all respect up to the entire satisfaction of Engineer-in-Charge of the work Make: AMP / Schneider / D-link.
SITC UTP Cat - Mounting Patch Cords complete in all respect up to the entire satisfaction of Engineer-in-Charge of the work Make: AMP / Schneider / D-link.
i) 3 ft length
ii) 5 ft length
SITC Layer 3 Switch Should have minimum 280 GBPS of higher switching capacity Port Standards: IEEE 802.3 10BASE-T Ethernet (twisted-pair copper), IEEE 802.3u 100BASE-TX Fast Ethernet (twisted-pair copper), IEEE 802.3ab 1000BASE-T Gigabit Ethernet (twisted- pair copper), IEEE 802.3z Gigabit Ethernet (fiber) ANSI/IEEE 802.3, Auto-negotiation, IEEE 802.3x Flow Control, Interface: 24 10/100/1000Mbps BASE-Tx,4 SFP Combo and 4 SFP+ :- UL,CE/IC,FCC, ROHS II. Protocol:- SNMP v1/v2/v3, IGMP v1/ MLD V2, DHCP Safety client/ Relay, Layer 2 & Layer 3 ACL, Surge protection ,Internal/External Redundant Power Supply, SD Card slot/USB/External flash for easy file store & restoration like firmware, configuration file, boot image, syslog, 1GB DRAM and 1GB flash, Management Port & Alarm Port, Protocols :ARP,Gratuitous ARP, 802.1Q VLAN encapsulation, 802.1v Protocol-based VLAN and MAC based Vlans, GVRP, QinQ, Multicast VLAN, 802.1D STP, MSTP, RSTP & Loopback Detection Layer 3 Routing Features :should support Static routing for IPv4 and IPv6, RIP for IPv4 and RIPng for IPv6, OSPF,OSPF v3, BGP4, BGP4+ IS-IS v4/V6 and MPLS from day 1, PIM-SM/PIM-DM/PIM-SDM/PIM-SMv6,DVMRP v3 and MSDP, VRRP v2 & V3 should support 802.1p priority queuing with 8 queues per port. Non Blocking Architecture of minimum 128 GBPS Backplane & 94 MPPS throuput. Make Cisco / Junipper/ Allied Telesis / Extreme.
FIRE ALARM & PA SYSTEM
SITC of Micro processor based 2 wire fault tolerant, networkable type Fire Alarm / Detection Control Panel (having nos. of loops to suit minimum 20% extra over the nos. of fire detectors. The panel shall be able to give location of all fire / fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, loop cards, minimum 160 characters LCD unit/ 5.7’’TFT to indicate Fire / Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The Panel Shall be sheet Steel power coated, sealed to IP30. The Panel shall have 20 Zones with individual LED Indicators, expandable to 80 LED Indicators. The Panel shall have 3 Serial Ports. The pane\l shall have a built in power supply and battery charger along with maintenance free 24 AH,2 x 12 volt SMF lead acid batteries capable of running for a minimum of 24 hours with battery charger complete as required. And conforming to BS5839 standards and Duly Approved by EN 54/UL/VDS/ as per specifications complete in all respect up to the entire satisfaction of Engineer-in –charge of work. Make: Bosch FPA 1000 / Cerberus by siemens/Honeywell Morley DXE Series/GST200
SITC of addressable multisensor detector with a combination of optical and thermal including base, auto addressing features as required. Detectors should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elemnets in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance wiht EFSG agreement EFSG/F/97/005. EMC safety for detector shall be 50 V/m. shall be EN54/VDS/UL certification. ((Detectors without inbuilt isolators may be considered with an additional isolator module after 20 devices) Make: Bosch FAP-440+T+FAA-440 /Siemens Cerberus OH921+DB-11 / Honeywell Morley HM-PTSE+B501/GST200
SITC of UL/EN54/LPCB listed and FM approved line isloating for isolation the section of circuit in case of short in the addressable loop wiring complete in all respect. Make: Bosch / Siemens Cerberus/ Morley/Edwards.
SITC of intelligent analog addressable type Manual Call point having surface or flush mounting option fully compliant to EN54 having rotary decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect upto the entire satisfaction of Engineer-in-Chage of the work. Make Siemens cerberus/ Morely/Bosch/Edwards.
SITC of addressable Loop powered hooter with strobe complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required complete the ob in all respect upto the entire satisfaction of Engineer - in - charge of work. Make: Bosch/ Siemens Cerberus/ Morley/Edwards.
Supply Installation Testing Commissioning of Addressable Control Relay Module with flexible network structures with a maximun switching current of 1A @ 30V DC. Shall be EN54/UL/VDS Certification Makes :Bosch /Siemens Cerberus / Morley/GST200
Supply Installation Testing Commissioning of Addressable monitor Module for monitoring of a line with EOL resistor/potential free contact/voltage monitoring shall be EN54/UL/VDS approved. (in case of 2 monitoring features in one module (points) each point shall be consider separately for payment). Makes: Bosch- FLM - 325 - 214/Siemens cerberus HTRI-M/Morley MI-DMMI/GST200
SITC 3 KVA Online UPS with isolation transformer suitable for single phase AC Input and single Phase AC output, Floor Mounted type Rating of UPS 3 KVA, Indicative Backup time 2 hours Complete in all respect including bettery etc. MAKE: APC/ Microtek/Luminous/Su-Kam
SITC of Analog Addressable type active repeater fire alarm panel with backlite LCD Display, having controls for reset, mute, accept, silence alarms and self rest conforming to BS5839 standards and duly approved by EN54/UN54/VDS with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer-in-charge of the work. Make:- BOSCH FPE-8000-FMR, Cerberus by Siemens, Morley ZxRA, Edwards 3-LCD-ANN.
SITC Intelligent Analog Addressable type Response Indicator with all labour and material required to complete the job in all respect Make Siemens cerberus/ Morely/ Edwards/Bosch.
SITC 17 U rack including power distribution kit, cable Manager complete in all respect Make: Valrack/Comrack/Ritall.
SITC of 1.5sqmm PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe. (Based on HSR 23.5.6.1) Make: Havells /Polycab/Finolex
SITC of PVC pipe ISI marked ( Medium ) recessed in wall / ceiling etc. including the cost of PVC bends , inspection boxes , iron hooks and cement concrete etc. complete in all respect upto the entire satisfaction of Engineer-in-charge of work (Based on HSR 23.7.6) Make: BEC/AKG/ Diplast/Polypack
i) 25mm dia
ii) 32mm dia
SITC Cat-6 cable in existing PVC conduit /PVC channel complete in all respect with all labour and material required to complete the job in all respect. (Based on HSR 23.23.9) (Make: AMP / Schneider / D-link)
NIT COMPUTERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .