Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LAccepted-AOC | ₹5.0 L | L1 | Accepted-AOC ok |
| 2 | L2₹5.1 LRejected-Finance | ₹5.1 L | L2 | Rejected-Finance higher bidder |
| 3 | L3₹6.2 LRejected-Finance | ₹6.2 L | L3 | Rejected-Finance Higher bidder |
| 4 | Rejected-Technical | - | - | Rejected-Technical document not Uploaded |
Tender Value
₹6.5 L
EMD Value
₹13,000
Closing Date
7 Nov 2025, 5:00 pmClosed
Executive Engineer
Executive Engineer, Sharda Sahayak Khand-51, Pratapgarh
Rejuvenation and Repair work of Residencial Building Type A5 of Sharda Sahayak Khand 51, Pratapgarh.
2025_UPIDC_1087483_2
02/S.S.K-51/2025-26
Open Tender
Civil Works
30 days
Pratapgarh
Please refer Tender documents.
3 documents required · 3 mandatory
₹766
₹13,000
Yes
5 Jan 2026
31 Oct 2025
10 Nov 2025
31 Oct 2025
7 Nov 2025
31 Oct 2025
Amount
Dismantling existing plaster including disposal of refuse as direction by Engineer-in-charge with a distance of 60 M.
Dismantling 1:4:8 lime or cement concrete
Dismantling R.B. Work including stacking of dismantled materials as directionwithin a distance of 60M.as directed by Engineer-in-charge
Dismantling lime or cement brick work including stacking of dismantled materials with in distance of 60M.as direction by Engineer-in-charge
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
Suspended floors, roofs, landings, balconies and access platform., Staircase mid landing
Edges of slabs & breaks in floors & walls
Extra for additional height in centering, shuttering where ever required with adequate bracing,propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landings, beams and balconies (Plan area to be measured)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars@100kg/cum
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work (RCC), using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately).All works above plinth level upto floor V levelConcrete of M25 grade with minium cement concrete of 330 kg/cum
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 coarse sand)
6 mm cement plaster of mix :1:3 (1 cement: 3 fine sand)
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification.Two or more coats on new work
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required(b) Group B
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed mediam class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. b) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Installation, Testing and Commissioning of pre-wired fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling / wall, including connections with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt )Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°CPowder coated die cast /Extruded aluminum Body including trima) 12 - 15 Watt
RAJ BAHADUR SINGH (BID ID -5660411)
M/S JAWAHAR LAL (BID ID -5655938)
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.47 MB
BOQ_1994636.xls
BOQ • 0.24 MB
BId2.pdf
Tender Documents • 1.06 MB
Download all tender documents and submit your bid