Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance DHA BEMA | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹2,500
EMD Value
₹1.5 L
Closing Date
19 May 2025, 2:00 pmClosed
Executive Engineer EDD Leh
PDD choglamsar
same as above
2025_PDNRE_16204_1
e-NIT No. 16 of ED Leh of 2025-26 dated 03-05-2025
Open Tender
Electrical Works
Turn-key
60 days
Leh
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,500
Payable To Executive Engineer EDD Leh
₹1.5 L
23 May 2025
3 May 2025
20 May 2025
3 May 2025
19 May 2025
5 May 2025
Amount
DT ( Supply Part )
Supply of 250KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
Supply of 100KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
Supply of 63KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
Supply of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
Supply of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
Supply of 11 kV Horn Gap Fuse Set 3 Phase 200A
Supply of 185mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 100kva DTs
Supply of 120mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 63kva DTs
Supply of 9 Mtr. Long Pole,ST-410 SP33)
Supply of 33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Supply of GI Channel/Angle/Flat of sizes including clamps
Supply of Galvinized Nuts and Bolts.
Supply of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Supply of 33kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Supply of LT Distribution Box for 250 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 120Amp and suitable MCCBs for outgoing circuits with terminal extensions
Supply of LT Distribution Box for 100 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 120Amp and suitable MCCBs for outgoing circuits with terminal extensions
Supply of LT Distribution Box for 63 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 90Amp and suitable MCCBs for outgoing circuits with terminal extensions
Supply of Danger Plates with Clamps
Supply of GI Barbed Wire for Anti Climbing
Supply of 3-Ø, 4-Wire Trivector Meter with CT(LTCT AMR compatible)
Supply of Cement bottoming 1:2:4 mix as per REC standards .5cum/pole
Supply of Painting of Poles Red Oxide
Supply of Painting of Poles Aluminium Paint
Supply of Sundry items like aluminium lugs, Jumpers, binding Tape,
Supply of Transformers Fencing binding Tape,
Installation/Testing /Commissioning Part of Substation.
Supply of 250KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
Supply of 100KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
Supply of 63KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
Supply of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
Supply of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
Supply of 11 kV Horn Gap Fuse Set 3 Phase 200A
Supply of 185mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 100kva DTs
Supply of 120mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 63kva DTs
Supply of 9 Mtr. Long Pole,ST-410 SP33)
Supply of 33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Supply of GI Channel/Angle/Flat of sizes including clamps
Supply of Galvinized Nuts and Bolts.
Supply of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Supply of 33kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Supply of LT Distribution Box for 250 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 120Amp and suitable MCCBs for outgoing circuits with terminal extensions
Supply of LT Distribution Box for 100 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 120Amp and suitable MCCBs for outgoing circuits with terminal extensions
Supply of LT Distribution Box for 63 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 90Amp and suitable MCCBs for outgoing circuits with terminal extensions
Supply of Danger Plates with Clamps
Supply of GI Barbed Wire for Anti Climbing
Supply of 3-Ø, 4-Wire Trivector Meter with CT(LTCT AMR compatible) (LTCT)
Supply of Cement bottoming 1:2:4 mix as per REC standards .5cum/pole
Supply of Painting of Poles Red Oxide
Supply of Painting of Poles Aluminium Paint
Supply of Sundry items like aluminium lugs, Jumpers, binding Tape,
Supply of Transformers Fencing binding Tape,
HT Line Supply Part
9 Mtr. Long Pole( ST-410 SP33)
GI V cross-arm with top Bracket including clamp(14.631 kg)
GI Channel including clamps,fish plate and braces(80 KG)
30 mm² ACSR Conductor
33kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative,(Double Disc on a Frame) creepage distance 320mm
Galvinized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Red Oxide
Aluminium Paint
Cement bottoming 1:2:4 mix as per REC standards .45cum /pole
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
Guard Netting
HT Line Installation/Testing /Commissioning Part
9 Mtr. Long Pole( ST-410 SP33)
GI V cross-arm with top Bracket including clamp(14.631 kg)
GI Channel including clamps,fish plate and braces(80 KG)
30 mm² ACSR Conductor
33kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative,(Double Disc on a Frame) creepage distance 320mm
Galvinized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Red Oxide
Aluminium Paint
Cement bottoming 1:2:4 mix as per REC standards .45cum /pole
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
Guard Netting
M/S VEENA CONSTRUCTION COMPANY (BID ID -157578)
M/S GYALSON ELECTRONICS (BID ID -157546)
M/S OTZER ENTERPRISE (BID ID -157621)
M/S TASHI PHUNTSOG GOVT CONTRACTOR (BID ID -157535)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .