Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.8 LAccepted-AOC SR NO 331 2B PLOT NO 43 R H NO 02 BALDEWA RAO BUNGLOW NEWA NMC WATER TANK PATHARDI SHIVAR NASHIK 422 009 INDEX NO E 84CWE AF LOHEGAON PUNE | NASHIK | MAHARASHTRA | 422009 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹30.0 L+₹27,157 (0.91%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹30.7 L+₹1.0 L (3.43%)Rejected-Finance 154 HANUMAN MANDIR DIKSHI TAL NIPHAD DIST NASHIK 422 302 | NASHIK | MAHARASHTRA | 422302 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹33.1 L+₹3.4 L (11.3%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹33.3 L+₹3.6 L (12.1%)Rejected-Finance 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | L5 | Rejected-Finance Not Lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
7 Dec 2023, 6:00 pmClosed
Garrison Engineer Nasik Road
Garrison Engineer Nasik Road AOP Complex Near AOP Gate PO Gandhinagar Nasik 422006
As per Tender Documents
2023_MES_628588_1
GE/NRC/8615/E8
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer Nasik Road
As per NIT
8 documents required · 8 mandatory
₹500
Garrison Engineer Nasik Road
₹80,000
Yes
20 Jan 2024
16 Nov 2023
9 Dec 2023
16 Nov 2023
7 Dec 2023
30 Nov 2023
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for taking out pipe line etc for repairs / laying cables etc and getting out in soft / loose soil complete all as specified and as directed by the Engineer - in - Charge.
All as per item No 01 above but more than 1.5 Mtr and upto 2 mtr.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer - in - Charge.
Removal of excavated material [soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed by the Engineer - in - Charge.
Supply and fixing in replacement of metal box MS enclosure made out of CRCA sheet 3.00mm thick of size 450mm x 450mm x 250mm depth complete with three phase and neutral aluminium bus bar of capacity 200 Amps and fixing of 3P, 100A MCCB mounted on epoxy insulators, fixing arrangement with suitable MS Clamps of size 32 x 6 mm thick all as specified and directed. Note : Rate for MCCB 100 Amp, Aluminium Busbar 3 pole and 1 neutral of 200 Amp, epoxy insulators and MS clamps of size 32 x 6mm included in this item rate.
Disconnecting & taking out cable LT 1100V grade any size complete all as specified.
Fixing and laying only in trenches or fixing or passing through pipe, 1100 Volts grade LT UG cable, 2 core 10 Sqmm, with XLPE insulated stranded Aluminium conductor served with an inner sheathing of PVC tape, Armoured with galvanised steel wire and overall sheathed including cable gland, lugs, jointing material etc, jointing, connecting and testing all as specified and directed.
All as per Ser item No. 7.00 here in before but 4 Core 16 Sqmm
All as per Ser item No. 7.00 here in before but 3.5 Core 25 Sqmm
All as per Ser item No. 7.00 here in before but 3.5 Core 35 Sqmm
All as per Ser item No. 7.00 here in before but 3.5 Core 50 Sqmm
All as per Ser item No. 7.00 here in before but 3.5 Core 70 Sqmm
All as per Ser item No. 7.00 here in before but 3.5 Core 95 Sqmm
All as per Ser item No. 7.00 here in before but 3.5 Core 120 Sqmm
All as per Ser item No. 7.00 here in before but 3.5 Core 150 Sqmm
All as per Ser item No. 7.00 here in before but 3.5 Core 185 Sqmm
All as per Ser item No. 7.00 here in before but 3.5 Core 240 Sqmm Note for Srl Item No 7 to 17 : LT cable any make will be issued to Contractor free for fixing only.
Supply, fixing and and laying only in trenches or fixing or passing through pipe, 1100 Volts grade LT UG cable, 2 core 10 Sqmm, with XLPE insulated stranded Aluminium conductor served with an inner sheathing of PVC tape, Armoured with galvanised steel wire and overall sheathed including cable gland, lugs, jointing material etc, jointing, connecting and testing all as specified and directed.
All as per Ser item No. 18.00 here in before but 2 Core 16 Sqmm
All as per Ser item No. 18.00 here in before but 3.5 Core 35 Sqmm
All as per Ser item No. 18.00 here in before but 3.5 Core 70 Sqmm
All as per Ser item No. 18.00 here in before but 3.5 Core 95 Sqmm
M&L for Double Walled Corrugated DWC HDPE Pipe of outer dia 50mm and innter dia 38mm including 90 degree bends with coupler and rubber ring laid in trenches of size 50 mm suitable for cable protection of size 2 core 10 sqmm to 3.5 core 50 sqmm cable complete all as specified and directed.
M&L for Double Walled Corrugated DWC HDPE Pipe of outer dia 90mm and innter dia 75mm including 90 degree bends with coupler and rubber ring laid in trenches of size 90 mm suitable for cable protection of size 70 sqmm to 185 sqmm cable complete all as specified and directed.
Supply only in replacement of PVC weather proof, hinged door, junction box with, 240V, Neutral link and 1No MCB SP of 6 Amps, necessary fixing arrangement such as 32x5mm clamps, nut, bolts, etc including dismantling old unservieable junction box all as specified and directed.
M&L for servicing of RO plant (Unit Aqua System) 05 Nos of different locations, of capacity 250 LPH complete including cleaning of cartridges, proper operation of backwashing, testing equipment wise performance, cartridge filter changing if required, cleaning in place of membrance, carbon media change (Activate carbon), other minor parts complete all as specified and directed by Engineer-in-Charge. Note :- (i) Servicing of RO plant (Unit Aqua System) 05 Nos, considered as a one Job for measurement. (ii) Minor Spare parts, Cartridges, Membrance and Chemical for washing/ backwashing, carbon media, etc. included in this item rate. Contractor will supply the stores without any extra cost. (iii) Contractor will submitte the servicing 'service report' to JE E/M / Engr-in-Charge after servicing of OEM rep. (iii) If any RO plant repair work has not been started by the Contractor after receiving of site order from Engr-in-Charge, Penalty for Rs. 1500.00 per day has been recovered from the Contractor.
Demolition of PCC of any description above/below ground level exceeding 15cm complete all as specified and directed by Engr-in-Charge.
M&L for PCC 1:4:8 type D2 using 40mm graded aggregate for pole / struts foundation etc all as specified and directed.
M&L for PCC 1:2:4 type C1 using 20mm graded aggregate for coping including necessary form work and fair finishing of exposed surface of concrete all as specified and directed.
Supply, fixing and install in replacement of 7 mtr height octagonal pole top 70 mm, bottom 130 mm, 3 mm thikness with base plate 200x200x12 mm and GI 64 micron, M19x600 EN 8 grade foundaction bolt and 1 mtr arm for light fittings complete including foundation drawing provided by OEM for foundation of pole. Note : Rate for RCC foundation as per drawing, Excavation, returning filling, 7mtr pole, foundation bolts and nuts included in this item rate.
Supply and fixing in replacement of cross arms. Bracings, support channel, backpate hooks etc fabricated from structural steel, sections (MS Channel) of required size and shape including nuts, bolts,washers, welding, bending , cutting cold or hot, drilling holes for inserting bolts as indicated and directed including painting with one coat of red oxide primer and two coats of silver aluminium paint complete all as specified and directed by Engr-in-Charge.
M&L for repairs to LT panel boards complete with necessary welding works to doors, replacement of unserviceable hinges and all drop bolt complete and painting with two coat of synthetic enamel paint of approved color internally and externally all as specified and as directed by Engineer-in-Charge. Note : (i) Rate for requisite stores i.e. hinges, welding rods, paint, primer, included in this item rate. (ii) All type T&P i.e. welding machine at site, compressor for spray paint etc. included in this item. (iii) If Panel repair work has not been started by the Contractor after receiving of site order from Engr-in-Charge, Penalty for Rs. 500.00 per day has been recovered from the Contractor.
Repair/Replacement and calibration of Wireless-Addressable CMS PANEL (CENTRALISED MONITORING SYSTEM),Using 7'' colour display ,Inbulit hooter 110DB,Battery Backup 8 hrs, (0-100 DEVICES)(automatic battery charging, history capacity-50% of devices, zone capacity-120 )with insert fuse holder, open central main panel with two floating wires with proper connectivity (red & Black wire) Antenna SMA Connector with 12 v battery ,7.3 Ah and check all system in identify dective items and replacement of the same with same capacity. Note:- (i) For item (1,2,3 &4) item requried for replacement will be measured & Paid seperatily. (ii) Contractor should submit test report of complete system duly signed by OEM/Ref of OEM
M&L for taking out old unserviceable MCCB TP/TPN four pole from existing LT panel board and supply and fix MCCB TP 63 amps capacity, rup capacity 16 KA at 415 volt 50 Hz AC supply including necessary modification in panel board if required to fix the MCCB complete with replacement of incoming and out going cable connection with lugs, aluminium conductor cable of proper size, nuts bolts all as directed.replacement of brunt lugs and wire/cable pieces etc as required at site.
All as per Item No. 34.00 above but 100 amps capacity, 16 KA complete all as specified and as directed by Engineer -in-Charge
All as per Item No. 34.00 above but 315/400 amps capacity rup cap 35 KA at 415 volt complete all as specified and as directed by Engineer -in-Charge
Supply only of 24v DC SMPS
Repair and replacement of Wireless addressable Hooter panel with inbuilt battery backup 8 hrs and inbuilt hooter 110 DB (Operating voltage -12 V DC FM modulation) check connectivity of wires red and black and check antennaof SMA connector with suitable top panel. check the connector of male and female and lead acid battery type 12V ,1.3 Ah after repair check the test button of dector or MCP
Repair and replacement of Wireless Addressable Manual Call Point(MCP).(voltage range-3-9 VDC, standby current- 5 µA, FM modulation, manual type, unique address)
Repair and replacement of Wireless Addressable Beam Detector with check the transmitter/ receiver unit and reflactor and check the princple of light obscuration and check the percentage of of beam light and check laser beam pointer,transmitter, red switch (SW 1) , terminals, Red LED (HL3), Green LED (HL1), Vertical adjustment, M4x12 Screw, Horizontal adjustment, DIP Switch (SW2) and Display digital guide
Supply only of Hooter/Sounder
M&L in replacement Earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to the GI strip 32 x 6mm, by means nut bolt, nuts, check nuts and washer of the GI Earth wire protected by provision of GI light grade pipe 40 mm incl provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregated with 40 mm thick cover with RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, taste point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified incl testing on completion”.
M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine for LT underground cables suitable for 0.4 Mpa working pressure complete all as specified and directed.
Taking down of faulty LT underground cable of size upto 3.5 x 25 sqmm from trenches/pole/wall etc for detecting fault including repair and jointing at site including relaying at the same location complete. Note : Excavation/Earth work and cable jointing & jointing kit shall be measured and paid for separately under relevant item of schedule .
Taking down of faulty LT underground cable of size above 3.5 x 25 sqmm upto 150 sqmm from trenches/pole/wall etc for detecting fault including repair and jointing at site including relaying at the same location complete. Note : Excavation/Earth work and cable jointing & jointing kit shall be measured and paid for separately under relevant item of schedule .
Supply and joint cable jointing kit straight through joint epoxy type of size 10 sqmm 4 core to 16 sqmm 4 core all as specified and directed.
Supply and joint cable jointing kit straight through joint epoxy type of size 25 sqmm 3.5 core to 50 sqmm 3.5 core all as specified and directed.
Supply and joint cable jointing kit straight through joint epoxy type of size 70/95 sqmm 3.5 all as specified and directed.
Supply and joint cable jointing kit straight through joint epoxy type of size 120 sqmm 3.5 to 150 sqmm 3.5 core all as specified and directed.
Supply, fixing, testing and commissioning in replacement of air break gang operated device, triple pole mechanically operated outdoor type, mounted on and including 11 KV H.T. polymer insulators and steel channel frame, GI operating rod, 25mm dia of suitable length with operating mechanism working from ground level, vertically operated including locking arrangement for operating handle, suitable for current rating upto 200 Amp, 11000 Volts working pressure all as specified and directed by Engr-in -Charge.
Supply and fix in replacement of dropout fuse unit explusion type for outdoor air break swirch (GOD) single pole, mounted on and including insulators for 11000 Volts working pressure fixed to and including MS channel with nuts, bolts, washers etc. synthetic bounded fuse carrying tube complete with line tabs and suitable for current carrying capacity upto 10-60 Amps only all as specified and directed.
M&L for replacement of Lightening arresters station class complete with all fittings, station class, discharge capacity 65 kilo amps, suitable for 11000 Volts all as directed by Engineer-in-charge.
M&L for required for locating fault in U/G HT cable by using fault detector machine including transportation and by carring out high pressure test all as directed by Engr-in-charge
NOTE : - AMOUNT OF SCHEDULE OF CREDIT RS.1,89,120.00 WILL BE DEDUCTED FROM TOTAL AMOUNT OF BOQ.
LAKARIYA ENTERPRISES
MAHIMA CONSTRUCTION
Shining Star Electricals
sapana enterprises
Mayur Electro Enterprises
M/s Ravi Electrical
KOYNA ENGINEERS PVT LTD
Bidder Name
sapana enterprises
MAHIMA CONSTRUCTION
KOYNA ENGINEERS PVT LTD
Mayur Electro Enterprises
M/s Ravi Electrical
Shree Sai Samarth Enterprises
Shining Star Electricals
LAKARIYA ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .