Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹24.2 LAccepted-AOC | 1 | Accepted-AOC L1 Bidder | |
| 2 | 2₹26.1 L+₹1.9 L (7.66%)Rejected-Finance 33 1 1 GOALAPARA ROAD P O AUTHPUR DIST NORTH 24 PARGANAS KOLKATA 743128 WB | KOLKATA | NORTH 24 PARGANAS | WB | 743128 | 2 | Rejected-Finance Not L1 Bidder | |
| 3 | 3₹26.5 L+₹2.2 L (9.15%)Rejected-Finance | 3 | Rejected-Finance Not L1 Bidder | |
| 4 | 4₹26.8 L+₹2.6 L (10.6%)Rejected-Finance | 4 | Rejected-Finance Not L1 Bidder | |
| 5 | 5₹27.4 L+₹3.2 L (13.0%)Rejected-Finance | 5 | Rejected-Finance Not L1 Bidder |
Tender Value
₹23.2 L
EMD Value
₹46,400
Closing Date
18 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NORTH KOLKATA
GE NORTH KOLKATA 46 BT ROAD KOLKATA 50
MISC BR AND EM REPAIRS TO PUMP HOUSE DUTY ROOM AND OTHER INSTALLATIONS AT DAKSHINESWAR AND 2CBPO UNDER GE NORTH KOLKATA
2020_MES_354848_2
8997/20-21/E8/GE/N/KOL/ OF 2020-21
Open Tender
Miscellaneous Works
Item Rate
180 days
DAKSHINESWAR
AS PER TENDER
7 documents required · 7 mandatory
₹500
GE NORTH KOLKATA
₹46,400
Yes
31 Aug 2020
11 Aug 2020
19 Aug 2020
12 Aug 2020
18 Aug 2020
12 Aug 2020
60 days
Amount
Demolition of brickwork built in cement mortar including all quoins, arches, pillars etc. complete all as specified and as directed.
Material and labour for brick work with bricks class designation 75, old size, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and as directed.
Material and labour for providing precast cement concrete louvers and jallies, 35mm thick including all moulding of type B0 1:2:4 using 12.5mm aggregate,set in cement mortar 1:4 including taking down old unserviceable ones complete all as specified and as directed.
Taking down cement or cement lime plaster of any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water , etc.
Material and labour for 20 mm thick plaster in cement mortar (1:4) in two layers, i.e 10mm thick in each layer,top layer mixed with integral water proofing liquid admixture as per manufacturers instruction on brick or concrete surfaces of wall,finished the surfaces fair and even complete all as specified and directed. Note: WPC shall be measured and paid separately.
Supply only integral water proofing liquid admixture for concrete and mortar. (Make :CONPLAST WL of Fosroc /SIKA No 1 of SIKA/equivalent brand of PIDILITE)
Dismantling of old GI barbed wire of any description from angle iron post complete all as specified and as directed.
Supply and fix galvanised 2 strand steel barbed wire 2.24 mm dia barbed with 2 mm barbed at 75 mm spacings and straining and fixing to any type of standard rails, straining bolts including securing or lying at corssling with and provision of galvanised mild steel wire staples or steel pins etc all as specified and as directed (Note : Each line of wire to be measured).
All as per Item No 8 here-in-above but fixing only. (serviceable barbed wire obtained from item No 7 shall be reused)
S&F in repairs to PVC coated chain link fencing of mesh 50x50 mm made out of 10 gauge dia mild steel wire overall dia 6 gauge after PVC coating including GI binding wire and fixing of MS round bar as line wire for holding chainlink mesh complete all as specified and directed.( Note MS round bar shall be measured and paid separately.)
M&L Round bar 10mm & over cut to length bent to shape as in support of fencing complete all as specified and directed.
Dismantling of wrought iron or mild steel work in post,fixed independently including demolition of cement concrete,complete all as specified and as directed.
Excavating in post holes (or similar holes), in hard and dense soil each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface complete.
Supply and fix rolled mild steel Fe-410(Grade E-250A) angle or tee section as in post ,cut to length and bend to shape as directed,fixed independently without connecting plate etc,including provision of 05 to 06 nos gaps/cuts/holes in each post for providing /laying barbed wire and one coat of red oxide zinc chrome primer after preparation of new steel surfaces complete all as specified and as directed.(Note: Supply and Fix barbed wire shall be measured and paid separately) Make:-Rinl / Sail / Tisco/JAI Balaji industries ltd / Shyam Steel industries Ltd. / SPS stell rolling mills ltd / SRMB Srijan Pvt Ltd / Electrosteel steels ltd / Shyammetallics and energy ltd / Jindal
All as per item No 14 above but fixing only. (Serviceable post obtained from item No 12 above shall be reused) Hence providing 05/06 Nos gap /cut/holes and applying primer on old surfaces complete).
Material and labour for two coats of synthetic enamel paint, first quality, to new steel surfaces of post of any description over 10cm width or girth complete all as specified and as directed. Make: Asian / Berger / Shalimar / Jenson & Nicholson.
M&L for Framed work such as gate, grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0. Make:-Rinl / Sail / Tisco/JAI Balaji industries ltd / Shyam Steel industries Ltd. / SPS stell rolling mills ltd / SRMB Srijan Pvt Ltd / Electrosteel steels ltd / Shyammetallics and energy ltd / Jindal
M&L for Granite(of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including 10 mm thick rendering/ screeding as in backing coat in CM(1:4) complete all as specified and as directed.
Taking out old unserviceable paving block including its base complete all as specified and as directed. (Note:Necessery excavation is deemed to be included within the quoted rate)
M & L for Hard core of broken stone or boulders of gauge n exc 63 mm deposited, spread and levelled in layers n exc 15 cm thick watered and rammed to a true surface .
Material and labour for Sand filling under floors or in foundation including watering, ramming, consolidation, etc. as required, complete as specified and as directed.
Material and labour for Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35, with grey cement and pigments complete all as specified and as directed. Make: Ultra tile / Anjali tiles / Nitco / Mehatab / Terra firma / Ecco scope./ M/S Stylish Precast Pvt ltd.
Materials and labour for PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) as in edges of path etc and similar item including necessary form work complete all as specified and directed.
Preparation of old plastered/unplastered surfaces of walls including cornices, pilasters etc and applying two coat of white wash on walls. Make Suryacem / Lovelycem / Birla white
Material and labour for preparation of new plastered surfaces of wall and applying three coats of white wash complete all as specified and directed. Make Suryacem / Lovelycem / Birla white
Demolition of concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed
Material and labour for 75mm thick PCC 1:3:6 type C-2 (using 40mm graded aggregate) as in pavement, pavement shall be laid in alternate bays and joints shall be filled with bituminous mastic filling comprising amixture of 1 part of heated industrial bitumen 85/25 grade and two parts of heated sand,surface finished fair and even complete all as specified and as directed. Make for bitumene:- STP / Tikitar / Chosky Chemicals.
M&L for providing cement concrete 1:5:10 type, E2, using 40mm graded aggregate as in sub base for floor complete all as specified and as directed
Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing), removing serviceable tiles to store and rubbish off the premises
M&L for (300x300) x25 mm thick PCC designer Pre-polished tiles (Factory made) as in floors, set & jointed in neat cement slurry and pointed in coloured cement with pigment over and including 20mm thick screed bed or bedding layer in CM(1:6) complete all as specified and as directed. Make: Ultra tile / Anjali tiles / Nitco / Mehatab / Terra firma / Ecco scope./ M/S Stylish Precast Pvt ltd.
S&F in repairs 2 mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with couach screw and washer in roof, wall etc all as specified and directed. Make: Fibreways Technology or Shiv Sakti Fibre Udyog ( Roffit M/S Dura roof PVT Ltd / M/S Prestar Infrastructures projects LTD
S&F Vitrified Ceramic tiles 10 mm thick(square/rectangular)polished area of each tiles exc 0.36 sqm but n exc 0.42 sqm in floor/dado etc and jointed in neat cement slurry and pointed in white or coloured cement to match in light shede including screed bed 15mm thick in CM 1:6 all as directed. Make:-Somany / Jhonson / Asian / Nitco / orient / Kajaria / varmoraGranito Pvt Ltd,
Material and labour for Non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but n.exc. 0.18 sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 15mm thick screed bed or bedding layer in CM(1:6) complete all as specified and as directed. Make:-Somany / Jhonson / Asian / Nitco / orient / Kajaria / varmoraGranito Pvt Ltd,
S&F Glazed ceramic coloured tiles ( 350x250mm/300x450)x7mm thick, in vertical etc. set & jointed in neat cement slurry & pointed in white or coloured cement to match including 10mm thick rendering as in backing coat for skirting/dado in CM (1:4) with on wall surfaces complete as specified, Make:-Somany / Jhonson / Asian / Nitco / orient / Kajaria / varmoraGranito Pvt Ltd,
Supply and fix in repair Rotational moulded polyethylene water storage tanks (multi layer) 500 Ltrs capacity (Cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and as directed. Make: Rotex / sintex / Polywell / SPL / Polycon / Oriplast
Supply and fix in repairs 20 mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms). Make:- Prayag / Polytuf / Supreme / Prince
Material and labour for applying one coat of synthetic enamal paint on steel surface of any description over 10cm widht or girth including preparation of old painted surfaces complete all as specified and as directed. Make: Asian / Berger / Shalimar / Jenson & Nicholson.
Material and labour for preparation of new plastered surfaces of wall and applying applying two coat of weather proof acrylic emulstion paint, first quality, over a coat of primer complete all as specified and as directed. Make:- Asian / Berger / Jenson & Nicholson.
Dismantling Asbestos Cement /transluscent/galvalume ( corrugated, semi corrugated etc) sheet in roof covering, wall, ridge, hips valleys and flashing etc.for the building structures not exceeding 10m height from the average ground level , complete all as specified and as directed.
S&F of Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
All as per item No 40 above but as in ridge. Make for item Nos 40 & 41:- M/S Tata Bluescope steel ltd. (colorbond steel) or equivalent in M/S JSW Steel Ltd / M/S Ispat Industries Ltd./ M/S Bhusan Power & Steel Ltd. ) /Sshiv shakti Fibre Udyog (Roofitt) / M/S Prestar Infrastructures projects LTD.,
Excavation in trenches not exceeding 1.5 m deep and 1.5 m wide and getting out in soft/loose soil for laying water pipe and all as specified and directed.
Cutting of road / hard standing / foot path not exceeding 0.30 mtr wide and 0.90 mtr depth for laying of pipe line including making good with PCC 1:3:6 type C2, 100 mm depth, etc complete complete all as directed.
Returning, filling in, including spreading levelling watering and well ramming in layers not exc 25 cm in soil.
Removing excavated material not exc 50 m above and depositing where directed at level not exc 1.5 m above the starting point.
Supply and fix in repair Non return valve (NRV) 80 mm intrnal dia for submersible pump all as per specification and as directed. Make:- Zoloto / Upadhyay / Rmco / Kirloskat /
Taking up or down steel tubing and disconnecting all as specified of following bore: 20 mm bore / dia.
All as per item Nos.47 above but, 25 mm bore / dia.
All as per item Nos.47, but 40 mm bore / dia.
Taking up or down unsrviceable CI / GI / MS water mains including all fittings with socketed / flanged pipe complete all as directed by Engg–in-charge ,size 80 mm bore / dia.
All as per item No. 50 but,100 mm bore / dia
S & F GI tubes 'medium grade' with all fitting laid in trenches, etc complete,size 25 mm bore / dia. Make:- Prakash / Utkarsh Tubes Ltd / Jindal / Zenith / Bansal / Nezone / M/S BST Infratech Ltd
All as per item No. 52 above but, 40 mm dia / bore
All as per item No. 52 above but,80 mm bore / dia.
S & F GI tubes 'medium grade' with all fitttings fixed complete in wall /ceiling / floor, etc complete, 20 mm bore / dia, all as directed by Engineer-In-Charge. Make:- Prakash / Utkarsh Tubes Ltd / Jindal / Zenith / Bansal / Nezone / M/S BST Infratech Ltd
All as per item No. 55 above, but 25 mm bore / dia.
All as per item No. 55 above, but 40 mm dia / bore.
Supply and laying MS pipe heavy grade laid in floor / wall / surfaces / trench with all fitting and completed with welding / tapering / reducing / cutting in reqd.shape etc complete of size, 80 mm bore / dia. Make:- M/S BST Infratech Ltd / Jindal / Tata
All as per item No. 58 above but, 100 mm bore / bore.
Supply and fixing, in repair, Butterfly Valves of following sizes 80 mm dia / bore. Make:- Zoloto / Kirloskar / Upadhyay / RMCO / Leader.
All as per item No. 60 above but,100 mm bore / dia.
S&F in repair gunmetal gate valve screwed down high pressure with iron wheel head screwed both ends for iron pipe or for union and fixed of 20 mm dia / bore. Make:- Zoloto / Upadhyay / Veenus / Kirloskar / Leader
All as per item No. 62 above, but 25 mm dia / bore.
All as per item No. 62 above, but 40 mm dia / bore.
S&F in repair cast iron sluice valve in any position double flanged complete with brass spindle, iron wheel handle clock wise closing with drilled hole flanged heavy duty PN 1.6 of following bore including rubber gasget, nut, bolts, washers including taking down unserviceable sluice valve of size 80 mm bore complete all as specified and directed. Make Kirloskar/Leader/Upadhyay / Zoloto.
All as per item No 65 here in above, but of 100 mm bore / dia.
M&L for CI/DI fittings like Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. , cross (all sockets or socket and spigot) collars, caps and plugs all as specified. Make:- Electro casting steel / Jindal / Sri pipes / Neco Centri / BIC / AIC / PIC / Jai balaji Industries / Tata Matliks / Tata Kabuto./ M/S Kiswok Industreies Pvt Ltd
Material and labour for brick work with bricks class designation 75, old size, straight or curved on plan exc 6m mean radius built in cement mortar (1:4) complete all as specified and as directed.
M&L for Providing, cement concrete 1:2:4 type B1 in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed
M&l for Rendering / plastering 15 mm thick with cement mortar (1:4) on fair faces of brick work or concrete surfaces and all as directed
S&F in repairs for 3.15 mm thick MS sheet cover and angle iron of size 50 x50 x6 mm thick frame with or in required size welded flat handle embedded in 15 cm thick PCC coping and hinges with locking arrangement fixed with all necessary fixing arrangement to old valve pit cover. Make:- Rinl / Sail / Tisco/JAI Balaji industries ltd / Shyam Steel industries Ltd. / SPS stell rolling mills ltd / SRMB Srijan Pvt Ltd / Electrosteel steels ltd / Shyam metallics and energy ltd / Jindal
M&L for painting with two coats of synthetic enamel paint,first quality, after preparation of new steel surface over one coat of red oxide primer.
M&L for painting of wall of repaired / existing valve pits or in any description with two coats of cement based paint, first quality, after preparation of surafces of any description and all as directed by Engg-in-charge. Make for item Nos. 72 & 73:- Asian / Berger / Jenson & Nicholson / Shalimar.
Supply only Calcium based granular disinfectant of strength more than 70% for water treatment, in 45 KG Drums Make - Aquafit /Declibac / RMCO or equivalent makes as per E-in-C's approval.
Taking out defective submersible pump set of discharge capacity varying from 15000 to 30000 GPH from bore wells including dismantling and taking out column pipes of any bore & length alongwith submersible cable, steel wire rope etc; and re-lowering the pump set after carrying out, servicing , overhauling necessary repairs / replacement of defective parts, reassembling, refixing, installing and testing, etc complete. all as specified and directed. (ii)Costs of all necessary T&P required at site and transportation is deemed to be included in the rates quoted.
S&F in repair 3 phase Digital VAF+PF Meter with input voltage range 70-520 volts AC, CT/PT site programmable, suitable for easurement of voltage, ampere, frequency, RPM and PF, flush mounting, 96X96 mm.class1 of 5A. Make:- Cat No.WDV303FC000 of L&T or equivalent in HPL/ Schinder .
S & F in repair Indicator lamp (set of three)
S & F in repair Digital Voltmeter suitable for 3 phase AC supply, CT/PT site programmable, 96x96 mm size, Class 1. Make: L&T Cat Part No: WDS301FEV00 or equivalent in in HPL/ Schinder .
S & F in repair Digital Ammeter suitable for 3 phase AC supply, CT/PT site programmable, 5 A, Class 1, 96x96 mm size. 5A of class1 Make: L&T Cat Part No: WDS301FCA00 or equivalent in HPL/ Schinder .
S&F in repair single phase preventor 415 volts AC 3 phase 50 Hz, suitable for 3 phase induction motors. Make : L&T / Minilec / HPL/ Schinder / C&S / Havells / Legrand .
Development of tube well by compressed air using portable compressor machine for 12 hours and after cleaning pumping out muddy water with 25% extra capacity pump for 12 hour per site including lifting and lowering of column pipes and submersible pump set of any capacity and all as directed.
Supply and fixing in repair MS Hexagonal nut and bolts, heavy duty with washer of 12mm dia and 80mm long or of any other size as required all as specified and directed. Make:- L&T / GKW / equivalent reputed make as approved by the GE.
Supply and fixing in repair of Nylon rope 20 mm dia
Excavation in trenches not exceeding 1.5 m deep and 1.5 m wide and getting out in hard/dense soil complete all as specified and directed.
Supply, Laying,connecting,testing and commissioning of XLPE insulated and PVC sheathed ,armoured heavy duty UG cable with stranded alluminium conductors 240 sqmm x 3.5 core,1100 Volt grade, laid in trenches/wall/Ducts/roof/pole/through pipe ,compleate all as specified and as directed including taking down old unserviceable one. Note :- (i) Pipe and bricks for cable protection and sand cushioning shall be measured and paid separately as per site .
Supply, Laying,connecting,testing and commissioning of XLPE insulated and PVC sheathed ,armoured heavy duty UG cable with stranded alluminium conductors 300 sqmm x 3.5 core,1100 Volt grade, laid in trenches/wall/Ducts/roof/pole/through pipe ,compleate all as specified and as directed including taking down old unserviceable one. Note :- (i) Pipe and bricks for cable protection and sand cushioning shall be measured and paid separately as per site. Make:- KEI / RR Kabel / Polycab / Finolex / Gloster / Nicco / HPL / Havells.
Supply and lay GI pipe 100 mm bore (dia) light grade in trenches/road crossing for protection of cable with necessary fittings as required complete all as specified and as directed. Make:- Prakash / Utkarsh Tubes Ltd / Jindal / Zenith / Bansal / Nezone / M/S BST Infratech Ltd.
Cutting hard standing / road for laying of cable / protection pipe complete all as specified and as directed.
Supply and fix straight through hot shrink cable joint kit for LT ug cable of size 250/300/400 sqmm 3.5 core undergruond cable at fault position and making good surface complete all as specified and as directed. Note:- Excavation and earth work is deemed to included in the unit rate quoted. Make:- Raychem / Denson / M- Seal
Supply and fix straight hot shrink cable joint kit for LT ug cable of size 120/95/70 sqmm 3.5 core including necessary excavatin of earth at undergruond cable at fault position and making good surface complete all as specified and as directed. Make:- Raychem / Denson / M- Seal
Material and labour for PCC (1:4:8) type D-2 (using 40mm graded aggregate) for filling and making good disturbed surfaces of road/hard standing etc complete all as specified and as directed
Material and labour for sand cushioning with clean dry sand in trenches for cable cushioning protection complete all as specified. Note:- Punned depth will only be measured and paid.
Materials & labour for earthing complete with galvanized earth plate electrode 600 x 600 x 6.0 mm thick, buried directly in ground (earth pit not less than 2.25 m deep below normal ground level ) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI strip of size 32x6 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth strip protected by and including 40mm dia GI pipe(light grade), alternate layers of charcoal and salt, including 20 mm bore GI tubing for watering to earth electrode, earth strip connected to test point/ distribution panel /feeder pillar etc as directed including necessary earth work, concrete pit with PCC (1:3:6) type C1, pre cast RCC(1:1:5:3) type A1 cover slab duly reinforced with 8 mm dia TMT bar 150mm c/c both way and two numbers lifting handle made of TMT bar and set in cement mortar (1:4), funnel, wire mesh, all as shown in electrical plate No 5 of SSR part-1 and testing on completion including taking out old earthing complete.
Supplying, fixing, connection and testing MCCB, 4 pole, 630 Amp capacity, 50/65 KA rupturing capacity, AC 415 volts with adjustable thermal and magnetic settings including taking down old unserviceable MCCB complete all as specified and directed.. (Make: Havells Cat part No IHLLNFEF0630/ /C&S Cat Part No- CSC6S4630/equvalent in Hager
Taking down old MCCB of any capacity from old LT pannel complete all as specified and directed..
Fixing only MCCB in new panel obtained serviceable condition of any capacity from old LT pannel complete all as specified and directed..
Supplying, fix in replacement connection and testing MCCB, 4 pole, 250 Amp capacity, 35/37KA rupturing capacity, AC 415 volts with adjustable thermal and magnetic settings including taking down old unserviceable MCCB complete all as specified and directed.. (Make: Havells Cat part No IHLLSEEF0250/C&S Cat Part No- CSC2A4 250/ equvalent in Haiger / L&T / Standard / HPL / Indoasian.
All as per item No.122 above but 200 Amp and rupturing capacity 35/37/25 KA with fixed thermal and magnetic setting. (Make: Havells Cat part No IHLFNF 0200/ Schneider cat part No -EZC250H4200/ C&S Cat Part No- CSE2NX250ATM4P 200//Hager Cat no HNB201U / equvalent in L&T / Standard / HPL / Indoasian.
Supplying, fix in replacement, connection and testing MCCB, 4 pole, 100 Amp capacity, 25/16/18 KA rupturing capacity, AC 415 volts with fixed thermal and magnetic settings including taking down old unserviceable MCCB complete all as specified and directed.. (Make: Havells Cat part No IHLGNF 0100/L&TCat part No CM 9051800 KO /C&S Cat Part No- CSC2A4 100/Hager Cat no HHA101Z / equvalent in L&T / Standard / HPL / Indoasian.
Supplying, fix in replacement,rubber/insulation mat 2.5mm thick insulated mat ISI 15652-2006 for 11 KV application along with suitable adhesive complete all as specified and directed.
Supply Electric grade rubber hand gloves 11 kv duly tested and ISI marked complete all as specified and directed..
Supplying, fix in replacement,chequer plate of 6mm thick for covering the duct of cable including cutting in required dimension complete all as specified and directed. Make:- Rinl / Sail / Tisco/JAI Balaji industries ltd / Shyam Steel industries Ltd. / SPS stell rolling mills ltd / SRMB Srijan Pvt Ltd / Electrosteel steels ltd / Shyam metallics and energy ltd / Jindal.
Supplying, fix in replacement Phase indicator (RYB ) lamps LED type.-01 set. Make:- HPL / C&T / L&T.
S Majumder and Construction
A ESS and CO
M/S SHEKHAR TRADING CORPORATION
RUNJEN CONSTRUCTION
Mother Lumier Industries
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .