Hyderabad Division: 53 High mast lights at 10 Goods shed GJWL-4, MDAK-7, DHP- 4, BDHN-5, SIPT-4, JKPT-9, JCL-3, GWD-4, ALPR-9 & VDI-4 of Hyderabad Division- Electrical Arrangements
16-PA-26-27-SrDEE-M-HYB
16-PA-26-27-SrDEE-M-HYB
Open
12 Months
Hyderabad, Telangana
₹0
₹7.2 L
11 Jun 2026
11 Jun 2026
23 Jun 2026
A-Electrical Arrangements (Note: Unit rates are inclusive of all taxes)
Design, fabrication, supply, erection, testing and commissioning of mini 12 Mtrs high mast system complete with all connected accessories. The mast shall be single section, hot dip galvanized, head frame, 2 point stainless steel wire rope 5 mm dia 7/19 construction, double drum 1 winch, galvanized lantern carriage arrangement suitable for 6 luminaries symmetrically with its control gear boxes, lightning and with all connected materials. The mast shall have an integral power tool installed inside the base compartment for its operation. This includes wiring with 5 core 2.5 sq.mm PVC insulated copper cable, except those mentioned as separate item, as per the direction of engineer at site.
Designing & casting M- 30 cement concrete foundation suitable for 12/16 m high mast considering the safe soil bearing capacity at site as per requirement at 3 meter depth including excavation foundation nut bolts etc. in an approved manner.
Supply & erection of fencing panels at high mast structures locations with size 2m height including all connected accessories as per the directions of the engineer at site.
Supplying and erecting Outdoor Stand Mounted Feeder Pillar for high mast of same manufacturer with 32A TPN MCB incomer, single dial timer switch 25 A TP contactor for automatic 4 switching of luminaries, 2 no 9A contactors and raise/lower push button, and provision for termination of Incoming minimum 35 sq. mm and outgoing minimum 16 & 25 sq. mm cables complete erected in min. 14 gauge CRCA sheet box with supporting angles, self lock, gasket and slanting top erected on CC foundation in an approved manner.
Supply, fixing, connecting and commissioning of 200 watt LED based flood light luminary with cool white light, pressure die cast aluminum housing, IP 65 or better having system complete as per specification.
Supply of 4core 16 mm² LT XLPE UG aluminium Cable, 1100 Volts as per IS:7098/Pt.I/1988 or latest.
Laying, connecting, testing and commissioning of LT PVC/XLPE cable of size 4 core 16 Sq.mm as per the direction of Engineer at site
Supply of 4core 25 mm² LT XLPE UG aluminium Cable, 1100 Volts as per IS:7098/Pt.I/1988 or latest.
Laying, connecting, testing and commissioning of LT PVC/XLPE cable of size 4 core 25Sq.mm as per the direction of Engineer at site
Supply of 4core 70 mm² LT XLPE UG aluminium Cable, 1100 Volts as per IS:7098/Pt.I/1988 or latest.
Laying, connecting, testing and commissioning of LT PVC/XLPE cable of size 4 core 70Sq.mm as per the direction of Engineer at site
Supply of 4core 120 mm² LT XLPE UG aluminium Cable, 1100 Volts as per IS:7098/Pt.I/1988 or latest.
Laying, connecting, testing and commissioning of LT PVC/XLPE cable of size 4 core 120Sq.mm as per the direction of Engineer at site
Supply and fixing of G.I. wire earth continuity of 8 SWG G.I. wire
Making of 8" bore and HDPE duct installation by HDD method as per the directions. All the joints of casing pipes should be tight and leak proof by HDD method as per the directions of engineer at site.
Excavation of cable trench 30 cm widex90cm deep in all types of soils for LTUG cable as per the directions of engineer at site.
Cutting of asphalted road/ concrete/ cement/ under the track etc., and excavation of 17 cable trench 30 cm widex90cm deep road etc., for laying of LTUG cable. After laying of cable the trench should be brought to its original position by providing tar/ concrete/ cement as per the site conditions and as per directions of Rly. Engineer.
Supply & erection of HDPE pipe of 110mm dia, PN-6, PE-100 of material grade as per IS 4984-2016 or latest, as per the directions of engineer at site
Supply & erection of HDPE pipe of 50 mm dia, PN-6, PE-100 of material grade as per IS 4984-2016 or latest, as per the directions of Engineer at site
Supply & fixing with suitable clamps/joints of 50 mm dia "B" class G.I. pipe as per the directions of engineer at site
Supply, fixing, connecting and commissioning of 60W LED street light complete with necessary clamps and hardware etc. as per Railway specification
Supply & erection of 5m long hot dip galvanized octagonal pole with 130mm bottom A/F and 70mm top A/F, made up of 3mm thick HT Sheet & Bakelite sheet & suitable MCB including 22 suitable size of loop-in & loop-out connectors (for mounting inside the base compartment of pole with hinged door opening arrangements), with base plate of size 200x200x12mm, M16X 600 long 'J' type EN8 grade foundation bolts, with 1000mm double arm bracket for fixing of LED light with all connected accessories, etc.
Excavation of pit for octagonal pole/ poles of suitable size in all type of soils as per the direction of engineer at site
Provision of concrete foundation and constructing the plinth as per the directions of engineer at site.
Supply, laying, connecting and commissioning of 3 core 1.5 mm sq.mm multi stranded FRLS cu. Conductor as per the directions of Engineer at site
Supply, fixing, connecting and commissioning of automatic light controlling nature switch device, grade sensors and advanced micro-controllers with suitable power contactor and MCB, enclosed in a FRP enclosure for pole mounting, confirming to IS-54 and similar to swadeep-02 EC-03 kW 1phase. The device should have the following specifications: 1)Operating voltage 26 range:120V, AC 50Hz 2)Switching endurance 5000 cycles of ON and OFF minimum 3)Operating illumination levels a)for switching On-less than 60Lux for 30 seconds b)for switching OFF-greater than 10Lux for 30 seconds 4)Auto voltage levels a)High voltage trip/auto reset - if voltage and gt 280 AC/and it 270V resp. 5)LED for indicating the operating status 6)During based switching OFF option of 04 to 08 hours with resolution of 1/2 hour 7)Override option-continuous ON and continuous OFF
Supply, erection, commissioning of 63A 4 Pole ELCB 6 KA with 100mA sensitivity as per the direction of the engineer at site.
Supply and fixing of 4 module Plexo Junction Box for MCB IP 65 protection.
Design, supply, installation, testing and commissioning of cubicle type 14SWG LT panel (Outdoor type) with 400 amps sectionalized electrolytic copper bus bar (copper bus bar should be uniform sizes RYBN) LT panel board should confirm to IS-8623 or latest, Advanced bi-direction Multi function meters with CTs of suitable capacity with R.S.485 port for incoming supply with CTs of 29 suitable and RYB LED indication lamps with all other connected accessories etc., as directed by Engineer at site. (1) 2 x 200/250A 4pole 35/36KA Microprocessor based MCCB including suitable spreader link (I/C) Out goings: 4 x 125/160 Amps 4 pole, 35/36 KA MCCB Microprocessor based including suitable spreader link, 1 x 125A Onload COS, 8 x 63A TPN 'C' curve 10KA MCB, 4 x 32A DP 'C' curve 10KA MCB. (2) Incoming for Generator supply 2 x 125A 35/36KA Microprocessor based MCCB including suitable spreader link Note:1) MCCBs: ICs=100% ICu 2) MCCBs should be Microprocessor based only
Supply, fixing, connecting and commissioning of steel sheet iron cubicle type 14 SWG Outdoor type DB with 250 amps sectionalized electrolytic copper bus bar (copper bus bar should be uniform sizes RYBN). LT panel board should confirm to IS-8623 or latest, bi-direction Advanced Multi 30 function meters with CTs of suitable capacity with R.S.485 port for incoming supply and RYB LED indication lamps with all other connected accessories etc., 2x125-160 A 4 pole 35/36 KA MCCB Microprocessor based including suitable spreader link (I/C), 4x63 A 10KA 'C' curve TPN MCB (O/G), 1x100 A change over switch as per directions of engineer at site. Note: 1) MCCBs: ICs=100% ICu 2) MCCBs should be Microprocessor based only 1386500.0
Design, supply, installation & commissioning of microprocessor type PLC based with single VFD for pump automatic Smart control panel SCADA enabled suitable for operation of 40 HP Booster system. The control panel will have protection like- over/under voltage, dry run protection, over/under current, phase reversal protection, single phasing protection and panel made up of 31 minimum 2mm thick steel sheet outdoor type. The control panel should be having remote monitoring/control system for operation and observation both through GSM/WIFI based communication. The control panel should be programmed in such a manner so that the VFD can operate upto 110% of total load condition if at any point of time on a multiple pressure variation water flow required. The control panel shall have cascade bypass operation due to failure of drive the pump will operate on direct mode. HMI touch screen display will be on the control panel body for operation. All MCCBs will be microprocessor based, as per the direction of Engineer at site.
Design, fabrication, fixing, connecting and commissioning of outdoor type cable 32 termination box of 2'x2'x1' size with 2mm thick sheet duly providing of clamps to fix with pole and have proper locking arrangements including suitable stand etc., as per the site requirement. This item also includes termination of existing cable to the termination box with copper bus bar of size 75x5mm & 63A 4P MCB as per the directions of the engineer at site.
Supply, fixing, connecting, testing & commissioning of Power Analyzer for monitoring 33 frequency, voltage parameters of 3 phase 433V A/C local supply with output devise and that of DG set with other connected accessories etc., as per the instructions of Engineer in-charge. Note: approval of competent authority is to be obtained before the supply of material.
Supply of earth pit materials and construction of earth pit as per IS 3043:1987 specification. This item also includes of supply and erection of CI pipe of size of 100mm inner diameter, 13mm thickness and 3000mm length. This work also includes of fabrication and fixing of GI strips for earthing connection. Excavated earth pit should be filled by mixture of coke/charcoal, salt and sand up to top. Provision of brick masonry chamber of size 650mmx650mm and depth upto 34 1000mm including light type CI cover frame and applying 12mm thick cement plaster in 1:3 inside and to all the exposed faces up to 300mm below. Foundation level, curing etc., All required materials for this job such as CI pipe cover with frame, salt, cement sand, charcoal gravel, bricks etc. required bolts, nuts and double washers, number plates or painted plates. Tentative quantity of salt and charcoal shall be of 2.5CMt. The CI pipe should be painted with 2 coats of bitumen paint as per the directions of Rly engineer at site. Note: The work should be strictly done as per IS 3043:1987 specification or latest.
Supply & laying/spreading of 20 mm ballast (hard granite metal) to electrical sub stations in SC area including transportation, loading and un loading of ballast at location as directed by the Engineer at site
Supply & erection of Cast Iron LT Cable Marker as per the directions of Engineer at site
Supply, laying, connecting & commissioning of 50x6mm/ 40x5mm/ 25x6mm thick GI Strip for earth pit as per the directions of engineer at site
Supply, fixing, connecting, testing and commissioning of 5 core 2.5 sq.mm PVC insulated FRLS copper cable
Removing of existing mini 12 Mtrs high mast system complete with all connected accessories and erection, testing and commissioning of the same at new location as per the direction of engineer at site.
Removing of existing LED flood lights on mini 12 Mtrs high mast system complete with all connected accessories and erection, testing and commissioning of the same at new location as per the direction of engineer at site.
Removing of existing Panel Board for mini 12 Mtrs high mast system complete with all connected accessories and erection, testing and commissioning of the same at new location as per the direction of engineer at site.
Transportation/shifting including loading & unloading from existing location to new 42 location of 9 no. of 12Mtr high mast including winch, LED fittings, panel boards, etc. from ALPR to Chowdarpalli between MBNR-MQNR section (100 to 150Km approximately) as per the direction of Engineer at site and if any changes the location as directed by the Engineer at site.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
NEFTForm.pdf
ATTACHMENT
ExperianceCertificate.pdf
ATTACHMENT
GCC_April-2022_2022_New.pdf
ATTACHMENT
CorrectionSlip2022_CE-I_CT_GCC-2022Policy14.07.2022_1.pdf
ATTACHMENT
ACS-3toGCCApril.2022RBCE_CE-I-CT2023_04_26.pdf
ATTACHMENT
ACS-2toGCC-2022-CE-1-CT-GCC-2022-POLICY_13.12.2022.pdf
ATTACHMENT
GCCACS11dt.13.03.2026.pdf
ATTACHMENT
ApprovedTB16-26-27T53nohighmast.pdf
ATTACHMENT
Download all tender documents and submit your bid