Loading…
Loading…
Tender Value
₹3.6 Cr
EMD Value
₹7.2 L
Closing Date
7 Jul 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
DRAWING
29 conditions · 9 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less, where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
(a) Attested Certificates(s) issued by Executive or Nominated Authority of the government Departments or Semi-Government/Public Sector Undertakings for the value of the work done for them during the qualifying period including current financial year certifying the bill amounts paid Agreement-wise and Date-wise or attested photo copy of such certificate. Such certificates will be accepted only from Govt. / Govt. bodies / PSUs authorities. Certificates issued by Private Bodies will not be considered.
(b) Audited Balance Sheets clearly indicating contractual receipts from the works done for Govt./ Govt. bodies / PSUs/Pvt. Organization in the P&L Account of the balance sheet duly certified by the Chartered Accountant for the completed & current Financial years.
NOTE: (i) Financial Year shall normally, be reckoned as 1st April to 31 st March of the Next Year. However, for Turnover Criteria, the Financial Year as applicable to the Company /Tenderer is to be considered, if it defers from the above. (ii) Current Financial year is reckoned as the incomplete Financial year in which the date of tender submission falls. (iii) Chartered Accountant statements duly indicating yearly receipts will not be considered until and unless backed by Audited Balance Sheets. (iv) If the tender is not accompanied by the certificate(s) in support of financial eligibility as above, the tender shall be rejected. No post-tender correspondence will be entertained.
If JV firms are allowed to participate; Financial eligibility of the JV Firm shall be adjudged based on satisfactory fulfilment of the Para No.17.15.2 of part-I of IRSGCC- 2019 for J.V guide lines (with upto date correction slip).
NOTE: If the tender is not accompanied by the certificate(s) in support of financial eligibility as above, the tender shall be rejected. No post-tender correspondence will be entertained.
The tenderer shall possess a valid Electrical Contractor License, issued by any State Government or Union Territory Administration, authorizing execution of electrical works up to 650 V. The contractor shall have in his employment or shall engage a person holding a valid certificate of competency issued by any State Government or Union Territory Administration for supervision of electrical works up to 650 V. Offers not accompanied by a valid Electrical Contractor License and requisite Supervisor competency for works up to 650 V shall be summarily rejected". The License should have been issued on a date prior to the date of Tender opening. Clear scanned copy is to be submitted along with the tender. A copy of license should be uploaded through IREPS with their offer, failing which the tender will be rejected.
Similar Nature of work: "Works of wiring/cabling or installation and commissioning of electrical items (other than on coaches) such as lights, fans, pumps, charging arrangements, earthing etc (with or without supply of items/equipments) for 230V, 1phase or 415V, 3phase system or higher voltages". a copy of similar nature of work should be uploaded through IREPS with their offer, failing which the tender will be rejected.
94 conditions · 9 needing a document upload
TENDER SHALL BE REJECTED if it is not accompanied by the following:
Cost of tender document & EMD deposited through IREPS e- payment
In case of Partnership firm : The tender form shall be submitted only in the name of partnership firm.
In case tenderer is JV Firm : The tender form shall be submitted 1.1.2 only in the name of the JV and not in the name of any constituent member.
Uploading of Certificate in support of Technical Eligibility (As detailed in Standard Technical Criteria).
Submission of Certificate(s) in support of Financial Eligibility (As detailed in Standard financial criteria).
IN CASE OF ADVERTISED TENDER VALUE IS MORE THAN RS. 20 CRORES: Bid capacity is applicable, the tenderers should submit proforma attached in DOCUMENTS. In case, the tenderer/s failed 1.3.1 to upload BID CAPACITY PROFORMA along with offer, their/his offer shall be considered as incomplete and will be rejected summarily.
In case tenderer is other than sole proprietorship firm, following documents shall be uploaded by the tenderer:
In case the Tenderer is a Partnership Firm: [i] Partnership deed . [ii]Power of Attorney (duly registered as per prevailing law) in favour of an individual to sign the tender documents and create liability against the Firm. [iii] PAN / TAN number of Partnership firm (PAN / TAN number in the name of any of the constituent partners shall not be considered). [iv]An undertaking by all partners of the partnership firm that they are not blacklisted or 1.4.1 debarred by Railways or any other Ministry / Department of the Govt. of India / any State Govt. from participation in tenders / contracts as on the date of opening of bids, either in their individual capacity or in any firm in which they were / are partners. Concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 of the General Conditions of Contract
In case the Tenderer is a LLP Firm registered under LLP Act-2008 (i) a copy of LLP Agreement, (ii) a copy of Certificate of Incorporation; and (iii) a copy of Power of Attorney/Authorisation 1.4.2 issued by the LLP Firm in favour of the individual to sign the tender on behalf of the LLP Firm and create liability against the Firm. (iv) copy of PAN number of the LLP Firm
In case the Tenderer is a Company registered under Companies Act-2013:(i) the copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company; and (ii) A copy of 1.4.3 Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company.(iv) copy of PAN number of the Company.
In case the Tenderer is a Registered Society & Registered Trust: (i) a copy of the Certificate of Registration, (ii) Deed of Formation; and (iii) a copy of Power of Attorney in favour of the 1.4.4 individual to sign the tender documents and create liability against the Society/Trust. (iv) copy of PAN number of the Society/Trust.
Incase JV Firms are allowed to participate: Uploading of MEMORANDUM OF UNDERSTANDING as per the format given in "Documents attached with tender" and also below documents.
In case one or more members is/are Proprietary Firm or HUF, the following documents shall be enclosed:: A copy of notarized affidavit on Stamp Paper declaring that his/her Concern is a 1.5.1 Proprietary Concern and he/she is sole proprietor of the Concern OR he/she is in position of "KARTA" of Hindu Undivided Family (HUF) and he/she has the authority, power and consent given by other partners to act on behalf of HUF.act on behalf of HUF.
In case one or more of the members of the JV is/are partnership firm(s), following documents shall be submitted:]:(a)A copy of the Partnership Deed, (b)A copy of consent of all the partners or individual authorized by partnership firm, to enter into the Joint 1.5.2 Venture Agreement on a stamp paper, (c)A copy of Power of Attorney (duly registered as per prevailing law) in favour of the individual to sign the MOU/JV Agreement on behalf of the partnership firm and create liability against the firm.
In case one or more members of the JV is/are companies, the following documents shall be submitted: (a)A copy of resolutions of the Directors of the Company, permitting the company to enter into a JV agreement, (b) A copy of Memorandum and 1.5.3 Articles of Association of the Company. (c) A copy of Authorization/copy of Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender, sign MOU/JV Agreement on behalf of the company and create liability against the company.
IN CASE THE TENDER VALUE MORE THAN RS. 50 LAKHS; Tenderers shall submit a notarized affidavit on a non-judicial stamp paper stating that all their statements / documents submitted along with bid are true and factual.
Uploading of Declaration regarding Employment of Retired Engineer/Retired Railway Officer as per clause no.17 of Part-I of IRSGCC. [in the format attached in - Documents]
Uploading of NEFT FORM - as per the format attached with the tender document.
The list of personnel / organization on hand and proposed to be engaged for the tendered work.
List of Plant & Machinery available on hand and proposed to be inducted and hired for the tendered work.
Uploading of Statement Showing the particulars of Works on Hand & Works Completed as per the format attached to the tender document.
Uploading of certificate by local suppliers in regard to meeting the Minimum Local Content requirement to avail benefits under Public Procurement Policy Order-2017 (A) for procurement order of value less than Rs. 10 crores: self certificate in accordance with Para-9(a) of Public Procurement(Preference to Make in India) Order 2017. (B) For Procurement Order of value more than Rs. 10 crores, the certificate from Statutory auditor/cost auditor/practicing CA as the case may be in accordance with Para-9(b) of Public Procurement (Preference to Make in India) Order 2017.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
IN CASE OF SINGLE PACKET TENDERS; CONSORTIUM AGREEMENTS, JOINT VENTURE FIRMS AND MOUS SHALL NOT BE CONSIDERED
IN CASE OF TWO PACKET TENDERS CONSORTIUM AGREEMENTS AND MOUS SHALL NOT BE CONSIDERED . BUT JOINT VENTURE FIRMS ARE CONSIDERED FOR ELIGIBILITY.
CONDITIONS FOR PARTICIPATION OF PROPRIETARY FIRM / PARTNERSHIP FIRM /PRIVATE LIMITED COMPANY / LIMITED COMPANY/ JV FIRMS:
In case the tenderer is an individual / proprietary concern, the experience and turnover shall be in the name and style of the Individual / Proprietary concern only.
In case the tenderer is a Partnership Firm, the experience and received contractual payments shall be in the name and style of the firm only. The other guidelines at Clause 18 of Part I of 4.1.1 IRSGCC shall be applicable . Note: The partner of a Partnership Firm cannot claim the credentials of Partnership firm to the extent of his share either during the subsistence of the Partnership firm or after its dissolution.
FOLLOWING DOCUMENTS SHALL BE ENCLOSED:
In case the Tenderer is a Partnership Firm: [i] Partnership deed . [ii]Power of Attorney (duly registered as per prevailing law) in favour of an individual to sign the tender documents and create 4.2.1 liability against the Firm. [iii] PAN / TAN number of Partnership firm (PAN / TAN number in the name of any of the constituent partners shall not be considered).
In case the Tenderer is a Company registered under Companies Act-2013:(i) the copies of MOA (Memorandum of Association) and AOA (Articles of Association) of the company; and (ii) A copy of Authorization/Power of Attorney issued by the Company 4.2.2 (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company.(iii) copy of PAN number of the Company.
In case of JOINT VENTURE (JV) FIRMS: Clause No.17 of Part-I of IRSGCC with upto date correction slip shall be applicable in all aspects for Participation of Joint Venture[JV] firms in works tenders. JV firm should submit Memorandum of 4.2.3 Understanding[MOU] as per the format attached as annexure to the tender in DOCUMENTS. Submission of all other documents by JV firm / Members of JV should also be as per Cl.No.17.14 of Part-I of IRSGCC.
In case the Tenderer is a LLP Firm registered under LLP Act-2008 (i) a copy of LLP Agreement, (ii) a copy of Certificate of Incorporation; and (iii) a copy of Power of Attorney/Authorisation 4.2.4 issued by the LLP Firm in favour of the individual to sign the tender on behalf of the LLP Firm and create liability against the Firm. (iv) copy of PAN number of the LLP Firm
In case the Tenderer is a Registered Society & Registered Trust: (i) a copy of the Certificate of Registration, (ii) Deed of Formation; and (iii) a copy of Power of Attorney in favour of the 4.2.5 individual to sign the tender documents and create liability against the Society/Trust. (iv) copy of PAN number of the Society/Trust.
Uploading of other relevant documents connected to the tender; such as Declaration regarding employment of Retired Engineer/ Retired Railway officer, NEFT Form, List of Personnel/Organization, List of Plant/machinery, Particulars of works on hand and completed (As per the formats attached in the list of Documents)etc.
Hyderabad Division: 53 High mast lights at 10 Goods shed GJWL-4, MDAK-7, DHP- 4, BDHN-5, SIPT-4, JKPT-9, JCL-3, GWD-4, ALPR-9 & VDI-4 of Hyderabad Division- Electrical Arrangements
16-PA-26-27-SrDEE-M-HYB
16-PA-26-27-SrDEE-M-HYB
Open
Works - General
12 Months
Hyderabad, Telangana
₹0
₹7.2 L
7 Jul 2026
11 Jun 2026
23 Jun 2026
85 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 3,61,67,868 | ||
| — | 53.00 | — | — | ||
| Design, fabrication, supply, erection, testing and commissioning of mini 12 Mtrs high mast system complete with all connected accessories. The mast shall be single section, hot dip galvanized, head frame, 2 point stainless steel wire rope 5 mm dia 7/19 construction, double drum winch, galvanized lantern carriage arrangement suitable for 6 luminaries symmetrically with its control gear boxes, lightning and with all connected materials. The mast shall have an integral power tool installed inside the base compartment for its operation. This includes wiring with 5 core 2.5 sq.mm PVC insulated copper cable, except those mentioned as separate item, as per the direction of engineer at site. | — | — | — | 98,24,186 | |
| — | 62.00 | — | — | ||
| Designing & casting M- 30 cement concrete foundation suitable for 12/16 m high mast considering the safe soil bearing capacity at site as per requirement at 3 meter depth including excavation foundation nut bolts etc. in an approved manner. | — | — | — | 56,67,854 | |
| — | 62.00 | — | — | ||
| Supply & erection of fencing panels at high mast structures locations with size 2m height including all connected accessories as per the directions of the engineer at site. | — | — | — | 5,89,000 | |
| — | 53.00 | — | — | ||
| Supplying and erecting Outdoor Stand Mounted Feeder Pillar for high mast of same manufacturer with 32A TPN MCB incomer, single dial timer switch 25 A TP contactor for automatic switching of luminaries, 2 no 9A contactors and raise/lower push button, and provision for termination of Incoming minimum 35 sq. mm and outgoing minimum 16 & 25 sq. mm cables complete erected in min. 14 gauge CRCA sheet box with supporting angles, self lock, gasket and slanting top erected on CC foundation in an approved manner. | — | — | — | 12,93,306 | |
| — | 350.00 | — | — | ||
| Supply, fixing, connecting and commissioning of 200 watt LED based flood light luminary with cool white light, pressure die cast aluminum housing, IP 65 or better having system complete as per specification. | — | — | — | 33,25,000 | |
| — | 2000.00 | — | — | ||
| Supply of 4core 16 mm² LT XLPE UG aluminium Cable, 1100 Volts as per IS:7098/Pt.I/1988 or latest. | — | — | — | 3,64,000 | |
| — | 2000.00 | — | — | ||
| Laying, connecting, testing and commissioning of LT PVC/XLPE cable of size 4 core 16 Sq.mm as per the direction of Engineer at site | — | — | — | 18,000 | |
| — | 10500.00 | — | — | ||
| Supply of 4core 25 mm² LT XLPE UG aluminium Cable, 1100 Volts as per IS:7098/Pt.I/1988 or latest. | — | — | — | 23,62,500 | |
| — | 10500.00 | — | — | ||
| Laying, connecting, testing and commissioning of LT PVC/XLPE cable of size 4 core 25Sq.mm as per the direction of Engineer at site | — | — | — | 1,15,500 | |
| — | 1000.00 | — | — | ||
| Supply of 4core 70 mm² LT XLPE UG aluminium Cable, 1100 Volts as per IS:7098/Pt.I/1988 or latest. | — | — | — | 5,60,000 | |
| — | 1000.00 | — | — | ||
| Laying, connecting, testing and commissioning of LT PVC/XLPE cable of size 4 core 70Sq.mm as per the direction of Engineer at site | — | — | — | 33,000 | |
| — | 600.00 | — | — | ||
| Supply of 4core 120 mm² LT XLPE UG aluminium Cable, 1100 Volts as per IS:7098/Pt.I/1988 or latest. | — | — | — | 4,70,400 | |
| — | 600.00 | — | — | ||
| Laying, connecting, testing and commissioning of LT PVC/XLPE cable of size 4 core 120Sq.mm as per the direction of Engineer at site | — | — | — | 30,000 | |
| — | 14103.00 | — | — | ||
| Supply and fixing of G.I. wire earth continuity of 8 SWG G.I. wire | — | — | — | 1,26,927 | |
| — | 300.00 | — | — | ||
| Making of 8" bore and HDPE duct installation by HDD method as per the directions. All the joints of casing pipes should be tight and leak proof by HDD method as per the directions of engineer at site. | — | — | — | 9,30,000 | |
| — | 10000.00 | — | — | ||
| Excavation of cable trench 30 cm widex90cm deep in all types of soils for LTUG cable as per the directions of engineer at site. | — | — | — | 13,00,000 | |
| — | 2000.00 | — | — | ||
| Cutting of asphalted road/ concrete/ cement/ under the track etc., and excavation of cable trench 30 cm widex90cm deep road etc., for laying of LTUG cable. After laying of cable the trench should be brought to its original position by providing tar/ concrete/ cement as per the site conditions and as per directions of Rly. Engineer. | — | — | — | 4,32,000 | |
| — | 500.00 | — | — | ||
| Supply & erection of HDPE pipe of 110mm dia, PN-6, PE-100 of material grade as per IS 4984-2016 or latest, as per the directions of engineer at site | — | — | — | 2,17,500 | |
| — | 11000.00 | — | — | ||
| Supply & erection of HDPE pipe of 50 mm dia, PN-6, PE-100 of material grade as per IS 4984-2016 or latest, as per the directions of Engineer at site | — | — | — | 19,80,000 | |
| — | 300.00 | — | — | ||
| Supply & fixing with suitable clamps/joints of 50 mm dia "B" class G.I. pipe as per the directions of engineer at site | — | — | — | 2,67,900 | |
| — | 126.00 | — | — | ||
| Supply, fixing, connecting and commissioning of 60W LED street light complete with necessary clamps and hardware etc. as per Railway specification | — | — | — | 3,54,060 | |
| — | 30.00 | — | — | ||
| Supply & erection of 5m long hot dip galvanized octagonal pole with 130mm bottom A/F and 70mm top A/F, made up of 3mm thick HT Sheet & Bakelite sheet & suitable MCB including suitable size of loop-in & loop-out connectors (for mounting inside the base compartment of pole with hinged door opening arrangements), with base plate of size 200x200x12mm, M16X 600 long 'J' type EN8 grade foundation bolts, with 1000mm double arm bracket for fixing of LED light with all connected accessories, etc. | — | — | — | 2,89,710 | |
| — | 30.00 | — | — | ||
| Excavation of pit for octagonal pole/ poles of suitable size in all type of soils as per the direction of engineer at site | — | — | — | 30,000 | |
| — | 30.00 | — | — | ||
| Provision of concrete foundation and constructing the plinth as per the directions of engineer at site. | — | — | — | 1,20,090 | |
| — | 200.00 | — | — | ||
| Supply, laying, connecting and commissioning of 3 core 1.5 mm sq.mm multi stranded FRLS cu. Conductor as per the directions of Engineer at site | — | — | — | 11,600 | |
| — | 3.00 | — | — | ||
| Supply, fixing, connecting and commissioning of automatic light controlling nature switch device, grade sensors and advanced micro-controllers with suitable power contactor and MCB, enclosed in a FRP enclosure for pole mounting, confirming to IS-54 and similar to swadeep-02 EC-03 kW 1phase. The device should have the following specifications: 1)Operating voltage range:120V, AC 50Hz 2)Switching endurance 5000 cycles of ON and OFF minimum 3)Operating illumination levels a)for switching On-less than 60Lux for 30 seconds b)for switching OFF-greater than 10Lux for 30 seconds 4)Auto voltage levels a)High voltage trip/auto reset - if voltage and gt 280 AC/and it 270V resp. 5)LED for indicating the operating status 6)During based switching OFF option of 04 to 08 hours with resolution of 1/2 hour 7)Override option-continuous ON and continuous OFF | — | — | — | 27,462 | |
| — | 30.00 | — | — | ||
| Supply, erection, commissioning of 63A 4 Pole ELCB 6 KA with 100mA sensitivity as per the direction of the engineer at site. | — | — | — | 1,12,320 | |
| — | 30.00 | — | — | ||
| Supply and fixing of 4 module Plexo Junction Box for MCB IP 65 protection. | — | — | — | 45,900 | |
| — | 1.00 | — | — | ||
| Design, supply, installation, testing and commissioning of cubicle type 14SWG LT panel (Outdoor type) with 400 amps sectionalized electrolytic copper bus bar (copper bus bar should be uniform sizes RYBN) LT panel board should confirm to IS-8623 or latest, Advanced bi-direction Multi function meters with CTs of suitable capacity with R.S.485 port for incoming supply with CTs of suitable and RYB LED indication lamps with all other connected accessories etc., as directed by Engineer at site. (1) 2 x 200/250A 4pole 35/36KA Microprocessor based MCCB including suitable spreader link (I/C) Out goings: 4 x 125/160 Amps 4 pole, 35/36 KA MCCB Microprocessor based including suitable spreader link, 1 x 125A Onload COS, 8 x 63A TPN 'C' curve 10KA MCB, 4 x 32A DP 'C' curve 10KA MCB. (2) Incoming for Generator supply 2 x 125A 35/36KA Microprocessor based MCCB including suitable spreader link Note:1) MCCBs: ICs=100% ICu 2) MCCBs should be Microprocessor based only | — | — | — | 4,71,699 | |
| — | 12.00 | — | — | ||
| Supply, fixing, connecting and commissioning of steel sheet iron cubicle type 14 SWG Outdoor type DB with 250 amps sectionalized electrolytic copper bus bar (copper bus bar should be uniform sizes RYBN). LT panel board should confirm to IS-8623 or latest, bi-direction Advanced Multi function meters with CTs of suitable capacity with R.S.485 port for incoming supply and RYB LED indication lamps with all other connected accessories etc., 2x125-160 A 4 pole 35/36 KA MCCB Microprocessor based including suitable spreader link (I/C), 4x63 A 10KA 'C' curve TPN MCB (O/G), 1x100 A change over switch as per directions of engineer at site. Note: 1) MCCBs: ICs=100% ICu 2) MCCBs should be Microprocessor based only | — | — | — | 7,93,464 | |
| — | 1.00 | — | — | ||
| Design, supply, installation & commissioning of microprocessor type PLC based with single VFD for pump automatic Smart control panel SCADA enabled suitable for operation of 40 HP Booster system. The control panel will have protection like- over/under voltage, dry run protection, over/under current, phase reversal protection, single phasing protection and panel made up of minimum 2mm thick steel sheet outdoor type. The control panel should be having remote monitoring/control system for operation and observation both through GSM/WIFI based communication. The control panel should be programmed in such a manner so that the VFD can operate upto 110% of total load condition if at any point of time on a multiple pressure variation water flow required. The control panel shall have cascade bypass operation due to failure of drive the pump will operate on direct mode. HMI touch screen display will be on the control panel body for operation. All MCCBs will be microprocessor based, as per the direction of Engineer at site. | — | — | — | 13,86,500 | |
| — | 12.00 | — | — | ||
| Design, fabrication, fixing, connecting and commissioning of outdoor type cable termination box of 2'x2'x1' size with 2mm thick sheet duly providing of clamps to fix with pole and have proper locking arrangements including suitable stand etc., as per the site requirement. This item also includes termination of existing cable to the termination box with copper bus bar of size 75x5mm & 63A 4P MCB as per the directions of the engineer at site. | — | — | — | 2,12,400 | |
| — | 4.00 | — | — | ||
| Supply, fixing, connecting, testing & commissioning of Power Analyzer for monitoring frequency, voltage parameters of 3 phase 433V A/C local supply with output devise and that of DG set with other connected accessories etc., as per the instructions of Engineer in-charge. Note: approval of competent authority is to be obtained before the supply of material. | — | — | — | 2,40,000 | |
| — | 160.00 | — | — | ||
| Supply of earth pit materials and construction of earth pit as per IS 3043:1987 specification. This item also includes of supply and erection of CI pipe of size of 100mm inner diameter, 13mm thickness and 3000mm length. This work also includes of fabrication and fixing of GI strips for earthing connection. Excavated earth pit should be filled by mixture of coke/charcoal, salt and sand up to top. Provision of brick masonry chamber of size 650mmx650mm and depth upto 1000mm including light type CI cover frame and applying 12mm thick cement plaster in 1:3 inside and to all the exposed faces up to 300mm below. Foundation level, curing etc., All required materials for this job such as CI pipe cover with frame, salt, cement sand, charcoal gravel, bricks etc. required bolts, nuts and double washers, number plates or painted plates. Tentative quantity of salt and charcoal shall be of 2.5CMt. The CI pipe should be painted with 2 coats of bitumen paint as per the directions of Rly engineer at site. Note: The work should be strictly done as per IS 3043:1987 specification or latest. | — | — | — | 13,92,000 | |
| — | 90.00 | — | — | ||
| Supply & laying/spreading of 20 mm ballast (hard granite metal) to electrical sub stations in SC area including transportation, loading and un loading of ballast at location as directed by the Engineer at site | — | — | — | 1,21,500 | |
| — | 400.00 | — | — | ||
| Supply & erection of Cast Iron LT Cable Marker as per the directions of Engineer at site | — | — | — | 1,10,000 | |
| — | 1200.00 | — | — | ||
| Supply, laying, connecting & commissioning of 50x6mm/ 40x5mm/ 25x6mm thick GI Strip for earth pit as per the directions of engineer at site | — | — | — | 84,000 | |
| — | 255.00 | — | — | ||
| Supply, fixing, connecting, testing and commissioning of 5 core 2.5 sq.mm PVC insulated FRLS copper cable | — | — | — | 84,150 | |
| — | 9.00 | — | — | ||
| Removing of existing mini 12 Mtrs high mast system complete with all connected accessories and erection, testing and commissioning of the same at new location as per the direction of engineer at site. | — | — | — | 2,73,060 | |
| — | 50.00 | — | — | ||
| Removing of existing LED flood lights on mini 12 Mtrs high mast system complete with all connected accessories and erection, testing and commissioning of the same at new location as per the direction of engineer at site. | — | — | — | 50,000 | |
| — | 9.00 | — | — | ||
| Removing of existing Panel Board for mini 12 Mtrs high mast system complete with all connected accessories and erection, testing and commissioning of the same at new location as per the direction of engineer at site. | — | — | — | 36,000 | |
| — | 15.00 | — | — | ||
| Transportation/shifting including loading & unloading from existing location to new location of 9 no. of 12Mtr high mast including winch, LED fittings, panel boards, etc. from ALPR to Chowdarpalli between MBNR-MQNR section (100 to 150Km approximately) as per the direction of Engineer at site and if any changes the location as directed by the Engineer at site. | — | — | — | 14,880 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
NEFTForm.pdf
ATTACHMENT
ExperianceCertificate.pdf
ATTACHMENT
GCC_April-2022_2022_New.pdf
ATTACHMENT
CorrectionSlip2022_CE-I_CT_GCC-2022Policy14.07.2022_1.pdf
ATTACHMENT
ACS-3toGCCApril.2022RBCE_CE-I-CT2023_04_26.pdf
ATTACHMENT
ACS-2toGCC-2022-CE-1-CT-GCC-2022-POLICY_13.12.2022.pdf
ATTACHMENT
GCCACS11dt.13.03.2026.pdf
ATTACHMENT
ApprovedTB16-26-27T53nohighmast.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .