Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.3 LAccepted-AOC | L1 | Accepted-AOC Awarded being 1st Lowest Bidder | |
| 2 | L2₹24.4 L+₹2.1 L (9.33%)Rejected-Finance | L2 | Rejected-Finance Rejected being 2nd Lowest Bidder | |
| 3 | L3₹24.9 L+₹2.6 L (11.6%)Rejected-Finance C O GENERAL DAIRY VILLAGE BARAGAON SRI GANGANAGAR 335 001 | GANGANAGAR | RAJASTHAN | 335001 | L3 | Rejected-Finance Rejected being 3rd Lowest Bidder | |
| 4 | L4₹25.6 L+₹3.3 L (14.6%)Rejected-Finance | L4 | Rejected-Finance Rejected being 4th Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹53,460
Closing Date
13 Jan 2021, 6:00 pmClosed
COMMANDER WORKS ENGINEER, SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
CA NO. CWE SGNR - 72 OF 2020-21 SPECIAL REPAIRS TO BUILDING NO. P-88 OF OR MARRIED ACCOMMODATION AT MILITARY STATION LALGARH JATTAN
2020_MES_387676_1
CA NO. CWE SGNR - 72 OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
GE LALGARH JATTAN
Class D
Category a(i)
10 documents required · 10 mandatory
₹500
GE LALGARH JATTAN
₹53,460
Yes
17 Feb 2021
16 Dec 2020
15 Jan 2021
16 Dec 2020
13 Jan 2021
30 Dec 2020
Amount
Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15cm in thickness (below or above ground level) complete all as specified and directed by Engineer-in-Charge.
Demolition of reinforced cement concrete of any description and in any position not otherwise specificlly provided for (reinforcement cut as required to facilitate demolition) complete all as specified and directed by Engineer-in-Charge.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc. complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster on brick / stone walls including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed by Engineer-in-Charge.
M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of each tile exc 0.18 Sqm but not exc 0.38 Sqm in floor over and including 15 mm thick screed bedding in cement mortar 1:6, set and jointed in neat cement slurry and pointed in coloured cement to match the floor complete all as specified and directed by Engineer-in-Charge.
M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of each tile exc 0.18 Sqm but not exc 0.38 Sqm on vertical surfaces such as skirting / dados over and including 10 mm thick backing coat in cement mortar 1:4, set and jointed in neat cement slurry and pointed in coloured cement to match the floor complete all as specified and directed by Engineer-in-Charge.
M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of each tile exc 0.06 Sqm but not exc 0.11 Sqm in floor over and including 15 mm thick screed bedding in cement mortar 1:6, set and jointed in neat cement slurry and pointed in coloured cement to match the floor complete all as specified and directed by Engineer-in-Charge.
M&L for glazed ceramic coloured tiles of size 350 X 250 X 7 mm / 450 x 350 x 7 mm thick on vertical surfaces such as skirting / dados over and including 10 mm thick backing coat in cement mortar 1:4, set and jointed in neat cement slurry and pointed in coloured cement to match the floor complete all as specified and directed by Engineer-in-Charge.
M&L for machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid over cement screed base laid over and including 15 mm thick screed bed in cement mortar 1:6, set and jointed with grey cement slurry mixed with pigment to match shade of the slab including rubbing and plishing complete all as specified and directed by Engineer-in-Charge.
M&L for machine cut kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over and including 10 mm thick backing coat in cement mortar 1:4 set and jointed in neat cement slurry mixed with pigment to match shade of the slab including rubbing and plishing complete all as specified and directed by Engineer-in-Charge.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed by Engineer-in-Charge.
M&L for 75mm thick PCC (1:4:8) type D2 using 40mm graded stone aggregate as in sub-base complete all as specified and directed by Engineer-in-Charge.
M&L for precast cement oconcrete 1:2:4 type B-1 in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete all as specified and directed by Engineer-in-Charge.
S&F mild steel TMT bars 10mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mmdia or securing with clip complete all as specified and directed by Engineer-in-Charge.
M&L for rendering, 15 mm thick on brick work or concrete surfaces in cement mortar 1:6 on wall finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for rendering, 10 mm thick on brick work or concrete surfaces in cement mortar 1:3 on ceiling finished even and fair and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for rendering, 5 mm thick on brick work or concrete surfaces in cement mortar 1:4 on ceiling finished even and fair and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for two coats of oil bound distemper on newly plastered surfaces of walls paint over 3mm thick wall care putty including preparation of surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for complete removal of existing treatment and two coats of oil bound distemper over 3 mm thick wall care putty on plastered surfaces of walls including preparation of surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for 3 coats of white wash on newly / old plastered surfaces incl preparation etc. complete all as specified and directed by Engineer-in-Charge.
M&L for 3 coats of white wash on newly / old plastered surfaces incl preparation etc. on ceiling complete all as specified and directed by Engineer-in-Charge.
M&L for two coats of cement base paint on newly / old plastered surfaces incl preparation etc. on wall complete all as specified and directed by Engineer-in-Charge.
M&L for broken brick boulder hard core of gauge, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge.
M&L for 75 mm thick PCC 1:3:6 type C-2 using 40 mm graded mechanically crushed stone aggregate as in plinth protection finished even and smooth without using extra cement with & including 10 mm wide, 30 mm deep joints at the rate of 3.00 mtr centre to centre and at every turning & filling the joints with bitumen & sand mixture complete all as specified and directed by Engineer-in-Charge.
M&L continous brick edging; with fly ash bricks old size bricks, with width equal to the width of the brick; liad dry on end vertically complete all as specified and directed by Engineer-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. and getting out hard/dense soil complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate in foundation, filling & mass complete all as specified and directed by Engineer-in-Charge.
M&L for brick work with fly ash bricks, old size bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
M&L for brick work with fly ash bricks, old size bricks straight or curved on plan to any radius in half brick thick walls, built in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:2:4 type B2 using 40mm graded aggregates as in benching / haunchig of manholes including forming channels including necessary formwork etc. complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:2:4 type B1 using 20mm graded aggregates as in coping and the like including weatjeromg.slightly rounded or chamfered angles and throating, as directed including necessary formwork etc. complete all as specified and directed by Engineer-in-Charge.
M&L precast cement concrete 1:2:4 type B1 using 20mm graded stone aggregate and set cement mortar 1:6 as in cover slabs (for manholes etc,) chajjas, shelves and similar articles with plain faces complete all as specified and directed by Engineer-in-Charge.
M&L Rendering 10mm thick on fair face of brick work in cement mortar 1:4 and finished surfaces even and smooth with using extra cement as specified including WPC complete all as specified and directed by Engineer-in-Charge. Note : - WPC shall be measured and paid seperately
M&L moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed by Engineer-in-Charge.
Supply and laying DWCPE (SN8) drain pipes 150mm inner dia as per IS-16098 (Part-II), laid in trenches on moorum bed to required slope, including all assessories / fittings, jointing and tested complete all as specified and directed by Engineer-in-Charge. Make :- Rex Polyextrusion Limited/ Dura line / Alom Poly Extrusions Ltd / Jain Irrigation
Returning, filling in, including spreading levelling including watering & well ramming in layers n. exc 25 cm any type of soil all complete all as specified and directed by Engineer-in-Charge.
Removing excavated material n.exc 50m and depositing where direcrted at a level n.exc 1.50 m above the starting point complete all as specified and directed by Engineer-in-Charge.
Cutting into existing manholes for connection of new drain making pipes and rendering cutting out existing benching & forming branch channel in PCC 1:2:4 type B1 smooth finished & forming benches as reqd etc for 150 mm bore complete all as specified and directed by Engineer-in-Charge.
M&L preparation of new steel surface of any description not otherwise described over 10 cm width or girth and apply two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
M&L preparation of old steel surface of any description not otherwise described over 10 cm width or girth and apply two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
Dismantling of brick tiles in floor laid dry and pointed in cement morter complete all as specified and directed by Engineer-in-Charge.
Demolition mud in roofs, any thickness, including plastering and leeping complete all as specified and directed by Engineer-in-Charge.
M&L PCC (1:7:12) using 40mm graded stone aggregate as filling of sunken floors/bottom and side of drain complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15mm thick on brickwork or concrete surfaces in cement mortar 1:4 and finished fair and even including mixing of WPC in mortar complete all as specified and directed by Engineer-in-Charge.
Supply only integrated water proofing compound complete all as specified and directed by Engineer-in-Charge. Make:- Dr Fixit/Fosroc/BASF/STP
Material and labour for creating fillet caving 50x50mm with polymer modified mortar on the junction of slab and wall as per manufacture instructions, Material and labour Providing for applying two coats of two component (1 part Liquid: 2 part Powder) ready to use cementitious waterproof coating on properly prepared surface by brush having elongation of >50% for the applying water proofing treatment as per following and complete all as specified and directed by Engineer-in-Charge. (i) Applying 1st coat of two components modified polymer coating on horizontal and verticle surfaces. (ii) Provn of glasses fiber mess of 2x2mm immediately on alone coating. (iii) Applying 2nd coat of two components modified polymer coating after 72hrs on horizontal and verticle surfaces. NOTE:- Complete treatment to be carried out by authorised applicatior of waterproofing manufacture. Make : Dr Fixit/Fosroc/BASF/STP
M&L for Roof treatment to RCC roof as follows:- (a) Cleaning the roof surfaces thoroughly using wire brusehes to remove sharp projections, cleaning joints, washing, drying and removing all dirt/dust to receive concrete padding/plaster etc. (b) Providing 15 mm thick screed bed or bedding layer of cement mortar (1:4) with WPC, finished even and smooth without using extra cement. (c) Providing one coat of approved bituminous primer @100 gms per sqm, over dried plastered surface. (d) Laying 3 mm thick APP membrane,(mineral finish) reinforced with non woven polyster fabric, by torch application. The overlapping while torching shall be 75 mm on longitudinal direction and 100 mm on the transverse direction complete all as specified and directed by E-in-Charge. Make : STP Dr Fixit/Pidilite, Texsa India Ltd/Tikitar Dansona/Bengal Bitumen Notes : (i) All joints and change in directions should be covered wih cement mortar (1:3) mixed with SBR latex @ 200 ml/bag of cement/as per site reqmt and cured well before laying membrane by torching. (ii) All angles and abuttments should be sealed well with extra care to ensure full bondage. (iii) Water proofing treatment shall be got carried out by approved authorised applicator of manufacturer only. The name of firm shall be got approved from GE before carrying out the work. (iv) The independent testing of membrane for technical parameters given in particular specifications shall be carried out from Govt approved labs having fascilities for testing of membrane. (v) The guarnatee of treatment shall be for min 10 yrs reckoned from date of completion of whole work.
M&L preparation of new bituminious of any description not otherwise described over 10 cm width or girth and apply two coats of aluminium paint complete all as specified and directed by Engineer-in-Charge.
M&L PCC 1:2:4 type B-1, using 20mm graded stone aggregate as in roof kerbs or mud stops, rounded or chamfered on edges including necessary form work etc complete all as specified and directed by Engineer-in-Charge.
M&L racking out joints/pointing to brick work or brick tiles laid flat in wall to bricks on edges in floors, surface channels, roofs etc. and keyed pointing to bricks walls in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhats or frames n.exc 1.5 sq. m each with shutters (without taking off shutters from the frame) complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhats or frames exc 1.5 sq. m but n.exc 4.0 sq. m each with shutters (without taking off shutters from the frame) complete all as specified and directed by Engineer-in-Charge.
Taking down shutters of any description exc 1 Sqm and n.exc 2 Sqm each complete all as specified and directed by Engineer-in-Charge.
S&F framed work as in chowkats of doors windows of angle iron ,gates or other section with gusset plates, rails, braces etc conforming to Gde Fe 410-0 complete all as specified and directed by Engineer-in-Charge.
M&L mild steel work in Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) grade Fe-410-W(Gde-E-250) quality-B complete all as specified and directed by Engineer-in-Charge.
S&F hold fast of flat iron 25 x 3 mm conforming to Fe-290 or Fe 330 including preparing the surfaces & treated with two coats for coaltar & sanded with clean sharp sand complete all as specified and directed by Engineer-in-Charge.
M&L for Cement concrete 1:3:6 type C–1 (using 20mm graded crushed stone aggregate) as in coping, hold fast, bed blocks or similar block etc complete all as specified and directed by Engineer-in-Charge.
Taking down existing shutter and refixing in same opening shutters of any description exc 1.0 Sqm but not exc 2.0 Sqm each complete all as specified and directed by Engineer-in-Charge. Note:- 'Refixing' includes taking down, easing and adjusting and also refixing builders hardware as required including renewal of unserviceable screws, cutting off extra length for tiling etc.
S&F 35 mm thick 2nd class hard wood factory made plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed by Engineer-in-Charge.
S&F 35 mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) complete all as specified and directed by Engineer-in-Charge.
S&F flush shutter 25mm thick solid core construction with block board core and plywood face panels; commercial type on both sides as cupboard and kitchen shutters complete all as specified and directed by Engineer-in-Charge.
S&F 150 mm long aluminium anodised handle, cast type complete all as specified and directed by Engineer-in-Charge.
S&F 100 mm long butt hinge, medium weight, cold rolled mild steel complete all as specified and directed by Engineer-in-Charge.
S&F for 300mm long aluminium alloy, anodised, sliding door bolt type not less than 16mm dia fixed complete all as specified and directed by Engineer-in-Charge.
S&F in repairs as 300mm ordinary rat tail rod pattern springs including roller and roller plate complete mild steel fixed complete all as specified and directed by Engineer-in-Charge.
M&L Block board, 19/20mm thick, grade 1 quality, exterior grade, decorative type with decorative face veneer on both face, fixed with screws to timber frame work complete all as specified and directed by Engineer-in-Charge.
M&L plain fillets, square, rectangular or triangular in section, wrought, secured with nails or brads, sectional area exc 3 & n.exc 6 Sq.cm of 2nd class hard wood complete all as specified and directed by Engineer-in-Charge.
S&F continous (piano) hinges, mild steel, bright finish or electrogalvanised (width of flaps 30mm ) complete all as specified and directed by Engineer-in-Charge.
S&F 125mm hasp and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed by Engineer-in-Charge.
S&F 125 mm long aluminium anodised handle, cast type complete all as specified and directed by Engineer-in-Charge.
S&F stainless steel wire cloth 0.63 nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 73 here-in-before but for fixing in repairs complete all as specified and directed by Engineer-in-Charge.
Hacking out old broken glass (any thickness, size, quality or description) from metal frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed by Engineer-in-Charge.
S&F 4mm thick sheet glass ordinary quality and glazing with oil putty in squares n. exc. 0.5 Sqm in each pane complete all as specified and directed by Engineer-in-Charge.
S&F 4mm thick figured sheet glass ordinary quality and glazing with oil putty in squares n. exc. 0.5 Sqm in each pane complete all as specified and directed by Engineer-in-Charge.
S&F 150 mm long floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring complete all as specified and directed by Engineer-in-Charge.
M&L preparation of new or previously untreated wooden surface of any description not otherwise described over 10 cm width or girth and apply two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed by Engineer-in-Charge.
M&L preparation of old painted wooden surface of any description not otherwise described over 10 cm width or girth and apply two coats of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
S&F drapery rods, coloured, standrad quality, powder coated not less than 25mm dia with heads at both ends and middle support, rings, etc. complete all as specified and directed by Engineer-in-Charge.
S&F in repair brass hat pegs, solid body, 125 mm to 175 mm (4 legs) complete all as specified and directed by Engineer-in-Charge.
S&F in repair towel rails 20mm dia 600mm long brass chromium plated superior quality brass chromium plated fancy type complete all as specified and directed by Engineer-in-Charge.
S&F in repairs vitreous china squatting pan Orissa pattern size 580 x 440 mm white with integral foot rests (excluding flushing cistern) but including CI 'P' trap set in and including concrete fixed complete all as specified and directed by Engineer-in-Charge.
S&F in repairs PVC valve less, syphonic action type flushing cistern,10 ltrs capacity low level, white, with inlet ball valve, float, handle and telescopic pipe and connection to pipe and flush pipe of polyethylene of low or high density or PVC, 32mm dia, for low level cistern complete all as specified and directed by Engineer-in-Charge.
S&F in repair vitreous china wash hand basin coloured angle back of size 400x400mm, long screwed shank fly nut flange end including cutting for and pinning in ends of brackets in 1:3 CM including 32mm dia chromium plated waste coupling/trap complete all as specified and directed by Engineer-in-Charge.
S&F pillar tap, fancy type, cast copper alloy chromium plated with capston head, screwed down high pressure with or without lettered with long screwed shank and fly nuts, screwed for iron pipe of 15 mm bore complete all as specified and directed. Wt not less than 450 gms complete all as specified and directed by Engineer-in-Charge.
S&F in repair bib tap 15mm bore cast copper alloy chromium plated long body fancy type with capston head and cup screwed down, hand operated, screwed for iron pipe or for brass ferrule complete all as specified and directed by Engineer-in-Charge.
S&F in repair CP brass stop/angle valve fancy type 15 mm bore cast copper alloy screwed down high pressure fancy type with long shank and cup fixed complete all as specified and directed by Engineer-in-Charge.
S&F in repair CP brass stop valve fancy type 15 mm bore cast copper alloy screwed down high pressure fancy type with long shank and cup (Concealed type) fixed complete all as specified and directed by Engineer-in-Charge. Make : Jaquar cat No- 7053 or equivalent in Marc / Plumber or as approved by GE
S&F in repair, shower rose, 125 mm size, brass chromium plated with sweivel joint complete all as specified and directed by Engineer-in-Charge.
S&F PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed by Engineer-in-Charge.
Dismentling of water tanks of capacity exc 500 and n.exc 1000 ltrs and removing from site complete all as specified and directed by Engineer-in-Charge.
S&F ISI Marked rotational moulded polythene water storage tank 500 ltr capacity of three layer vertical with closed top hoisted and fixed in position all as specified in SSR Part-I complete all as specified and directed by Engineer-in-Charge.
S&F in repair gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of 20mm bore fixed in repair complete all as specified and directed by Engineer-in-Charge.
S&F in repair ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed in 20mm dia bore pipe complete all as specified and directed by Engineer-in-Charge.
Taking down 15 mm dia steel GI tubing including all connected fittings of any dia and in any position including cleaning for re fixing the serviceable pipe complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 98 here-in-before but for 20mm dia pipe complete all as specified and directed by Engineer-in-Charge.
S&F 15 mm dia galvanised steel tubing medium grade including necessary fittings like sockets, tees, elbows, reducers, unions etc fixed to walls / ceiling complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 100 here-in-before but for fixing only 15mm dia pipe old retrieved GI tubing after cleaning with new fittings complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 100 here-in-before but for 20mm dia pipe complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 100 here-in-before but for fixing only 20mm dia pipe old retrieved GI tubing after cleaning with new fittings complete all as specified and directed by Engineer-in-Charge.
Supply & fixing 100 mm bore cast iron hubless pipe waste and vent pipe in any length with or without ears laid in trenches/floor/wall including clamps, jointing with necessary coupling complete all as specified and directed by Engineer-in-Charge.
S&F in repairs cast iron type hubless P trap/CPWD floor trap 100mm bore with CP grating including jointing to waste pipe fixed with necessary coupling arrangement complete all as specified and directed by Engineer-in-Charge.
S&F in repair 100mm bore cast iron hubless type door T equal/uneqal branch pieces (any radius) diminishing pieces or tapers (larger bore measured) door fixed with necessary coupling complete all as specified and directed by Engineer-in-Charge.
S&F in repair 100mm bore cast iron hubless type plain bends (any radius) dimining pieces or tapers (larger bore measured) door fixed with necessary coupling complete all as specified and directed by Engineer-in-Charge.
Supply only 100 mm bore sheilding (ss) coupling (with epdm rubber as per requirement complete all as specified and directed by Engineer-in-Charge.
Supply & fixing 75 mm bore cast iron hubless pipe waste and vent pipe in any length with or without ears laid in trenches/floor/wall including clamps, jointing with necessary coupling complete all as specified and directed by Engineer-in-Charge.
S&F in repairs cast iron type hubless P trap/CPWD floor trap 75 mm bore with CP grating including jointing to waste pipe fixed with necessary coupling arrangement complete all as specified and directed by Engineer-in-Charge.
S&F in repair 75mm bore cast iron hubless type door T equal/uneqal branch pieces (any radius) diminishing pieces or tapers (larger bore measured) door fixed with necessary coupling complete all as specified and directed by Engineer-in-Charge.
S&F in repair 75mm bore cast iron hubless type plain bends (any radius) dimining pieces or tapers (larger bore measured) door fixed with necessary coupling complete all as specified and directed by Engineer-in-Charge.
Supply only 75 mm bore sheilding (ss) coupling (with epdm rubber as per requirement complete all as specified and directed by Engineer-in-Charge.
Supply & fixed Clamp for hanging/ fixed of 75mm/100mm hubless pipes complete all as specified and directed by Engineer-in-Charge.
Taking down eaves gutters and rainwater pipes (any size or pattern) including all fittings, heads, shoes, bends, swan-necks etc., including cleaning or refixing or removal to Store complete all as specified and directed by Engineer-in-Charge. Note : measured overalll as fixed along the cente line over fittings and accessories
S&F 110 mm dia PVC SWR pipe, single socketed in any length with rubber ring joints fixed with clamps to walls complete all as specified and directed by Engineer-in-Charge.
S&F 110 mm dia PVC (SWR) bend any radius complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 32 mm dia low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors complete all as specified and directed by Engineer-in-Charge.
S&F in repair sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915 mm x 460 mm bowl size 410 mm x 330 mm x 160 mm complete all as specified and directed by Engineer-in-Charge.
Taking down carefully copper/aluminium point wiring (light, socket or power) complete (fittings such as switches, ceiling roses, pendants, regulatos, sockets etc to be measured separately), and making good disturbed surfaces of walls, floors etc to match with existing surfaces complete all as specified and directed by Engineer-in-Charge.
Taking down MCB with sheet metal enclosure, main switch, DB etc and making good disturbed surfaces to match with existing surfaces complete all as specified and directed by Engineer-in-Charge.
Taking down sub main wiring of any size/capacity complete all as specified and making good disturbed surfaces to match with the existing surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for concealed Point wiring with two single core PVC insulate, unsheathed multistranded copper conductor cable of size 1.5 sq.mm (FRLS) drawn in and including electrical grade PVC conduit 20 mm dia concealed on wall/ceiling/floor including PVC insulated unsheathed earth wire with multi stranded copper conductor of size 1.5 sq.mm(FRLS) including MS shunk sheet metal box with 3 mm thick hylam sheet top cover of required size for mounting switches, sockets etc for one light / fan / exhaust fan point controlled by one, one way switch complete all as specified and directed by Engineer-in-Charge. Note - quoted rate shall include making good to the disturbed surfaces including plastering and painting to match with the existing colour
All as per Srl item No. 123 here-in-before but for one bell/buzzer point controlled by one bell push complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 123 here-in-before but for one 3 pin switch socket outlet, 5 Amp on the same board with other switches complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 123 here-in-before but for one 3 pin 5 amps switch socket outlet point on independent board complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 123 here-in-before but for two way point controlled by two way switch complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 123 here-in-before but for wiring with 4 sq.mm multistranded cable and earth wire with copper conductor of size 4 sq.mm for 15 amps power point complete all as specified and directed by Engineer-in-Charge.
Supply and fix piano switch flush button single pole one way 5 Amps complete all as specified and directed by Engineer-in-Charge.
Supply and fix socket 2 in 1, 2/3 pin 6 amp flush type 250 volts AC complete all as specified and directed by Engineer-in-Charge.
Supply and fix socket 2 in 1, 3 pin 5 amp and 15 amp flush type 240 volts AC complete all as specified and directed by Engineer-in-Charge.
Supply and fix piano switch 15 amp flush type single phase one way 240 volts AC complete all as specified and directed by Engineer-in-Charge.
Supply and fix switch piano flush button single pole two way 6 Amps complete all as specified and directed by Engineer-in-Charge.
S & F LED light fitting 1 x 18 W, 230 V integral sleek polycarbonate LED Channel with white acrylic cover including making connection complete all as specified and directed by Engineer-in-Charge.
Supply and fix lamp holder insulated body with back plate for angle/batten fitting with LED of 09 watt complete all as specified and directed by Engineer-in-Charge.
Supply & fix piano bell push flush type 6 Amp complete all as specified and directed by Engineer-in-Charge.
Supply & fix bell AC 230 volt single pole complete all as specified and directed by Engineer-in-Charge.
Supply and fix ceiling rose surface bakelite two to three terminals/plate 5 amps complete all as specified and directed by Engineer-in-Charge.
Supply and fix fan regulator electronic solid state with steps suitable for 1200/1400mm sweep ceiling fan working on 230 volt AC complete all as specified and directed by Engineer-in-Charge.
Supply and fix sheet metal enclosure DB single pole and neutral for 240 volts 8 way with 200 Amps rated busbar flush/surface mounting double door including wooden board complete all as specified and directed by Engineer-in-Charge.
Supply and fix MCB single pole 240 volt 5-32 amps 10 KA, complete all as specified and directed by Engineer-in-Charge.
Supply and fix MCB SPN 240 volt 63 amp 10KA complete all as specified and directed by Engineer-in-Charge.
Supply and fix MCB SP 240 volt 63 amp 10KA complete all as specified and directed by Engineer-in-Charge.
Supply and fixing PVC Blanking Plates one way with internal lock complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Sub Main Wiring with two run single core 6 Sqmm PVC insulated unsheathed (FRLS) cable with stranded copper conductor drawn in PVC conduit & accessories Suitable size with and including 6 Sqmm copper green colour earth wire complete all as specified and directed by Engineer-in-Charge. NOTE-two run of 6 sq.mm & One run of 6 sq.mm & One run of PVC conduit with accessories shall be measured as One length.
Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 Mtr below normal ground level connected to GI strip 32mm x 6mm dia by means of bolts, nuts, check nuts and washers complete including earthing pit, chemical compound, earthing lead 32mm x 6mm dia upto 7.5 Mtr, 20mm dia medium grade GI watering pipe, GI protection pipe 40mm dia earth pit in PCC 1:2:4 type B-1 using 20mm graded stone aggregate RCC pit cover including earth work complete all as shown in electrical plate No. 5 of SSR-2009 (Part-I) complete all as specified and directed by Engineer-in-Charge. Note : The unit rate shall be include for excavation and earth work in any type of soil / strata, PCC 1:2:4, type B-1 for pit and RCC 1:2:4 type B-1 for cover with 8mm dia CTD bar @ 150mm centre to centre both way, funnel with watering pipe 20mm dia medium grade, 15mm dia light grade GI pipe upto 7.5 Mtr long, wire mesh complete all as specified and directed by Engineer-in-Charge.
S&F sheat metal enclosure single pole and neutal with 02 Pin and earth plug and socket complete with 01 single pole MCB 20 Amps 240volts complete including necessary fixing arrangement and all incoming and outgoing electric connection complete all as specified and directed by Engineer-in-Charge.
M&L for taking down Exhaust fan 300 mm sweep single phase 240 volt 50 Hz and refixing the same incl all electrical connection, fastners of required size complete all as specified and directed by Engineer-in-Charge.
Supply and fix fresh air fan 300 mm sweep 240 vot 50 Hz plastic body complete with louvers complete all as specified and directed by Engineer-in-Charge.
Supply & fixing Water heater (Geyser) storage type, energy efficient BEE 5 star rating, AC 230 volts of capacity 25 Ltrs, ISI marked complete with stainless steel water tank duly coated with corrosion resistant insulating material and rust free ABS body, having temperature cut off switch (thermostat) and anticorrosion anode rod, braded inlet and outlet connections suitable for hot and cold water complete all as specified and directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core complete all as specified and directed by Engineer-in-Charge.
Excavaton in trenches for laying of cable , for pole & stay n.exc.1.5mtr wide & n. exc. 1.5 mtr iin depth & getting out in soft / loose soil complete all as specified and directed by Engineer-in-Charge.
Removing the excavated material (soil) upto a distance n.exc.50 mtr & depositing where directed a level n.exc. 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
Returning & filling in including sprading levelling, watering & well ramming in layers n.exc.1.5 mtr above starting point in soil complete all as specified and directed by Engineer-in-Charge.
M&L for natural dry sand cushioning for cable protection complete complete all as specified and as directed complete all as specified and directed by Engineer-in-Charge.
Supply and laying best quality locally availble Sub class 'B' bricks(oldsize) for cable protection cover, laid flat and lay in trenches over tge cable complete all as specified and directed by Engineer-in-Charge.
M&L for repair to door hinges of MS housing of size 0.90x0.60 m including necessary welding and painting the panel with two coat of synthaticenamelled paint over a coat ofred oxide primer complete all as specified and directed by Engineer-in-Charge. -------------------------------------------------------------------------- Note : A sum of Rs. 97,930.00 will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 32 & 33 (Schedule of Credit) of Tender document
Aggarwal brothers and company
PAREEK AND COMPANY
M/s Tarun Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .