Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.5 LAccepted-AOC | L1 | Accepted-AOC Being lowest and reasonable | |
| 2 | L2₹43.0 L+₹6.3 L (17.0%)Rejected-Finance | L2 | Rejected-Finance Being not lowest |
Tender Value
₹33.4 L
EMD Value
₹67,000
Closing Date
6 Dec 2021, 6:00 pmClosed
GE
GARRISON ENGINEER JORHAT, MES, JORHAT-785005
SPECIAL REPAIR TO BLDG NO T-45 AT ASC AND PROVN TILING ON UNDER WATER DIVING TANK AT ROWRIAH UNDER GE JORHAT
2021_MES_478172_2
8033/E8
Open Tender
Civil Works
Item Rate
180 days
JORHAT-785005
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
GE JORHAT
₹67,000
Yes
18 Dec 2021
18 Nov 2021
7 Dec 2021
18 Nov 2021
6 Dec 2021
24 Nov 2021
18 Nov 2021 - 20 Nov 2021
Amount
NOTES :(i)The bidders/contractors are advised to read tender document & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates. SCHEDULE 'A' PART - I FOR B/R PORTION (Sl No 02 to ___ )
Dismantling plain/corrugated steel sheeting, any guage, thickness including eves gutter / rain water pipe complete & removal all as specified
Supply and fixing of pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick and pitch length 75 mm c/c of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Supply and fixing of pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in ridges, tips, valley, gutters, length & girth as fixed with nail or screws complete all as specified and as directed.
Supply and fixing of Galvanized, corrugated mild steel sheeting with two corrugation side lap, fixed with 'L' or 'J' bolts in roofs, 0.63 mm thick (275 gms/sqm zinc coating) complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to stores and rubbish off the MOD premises complete all as specified and as directed.
Material & Labour of machine cut kota stone slab 20-25 mm thick as riser of step, skirting, dado etcover cement screed base laid and jointed with grey cement slurry mixed with pigment to match shade of slab iuncl rubbing and polishing over 10mm thick screed bed layer in CM (1:3) complete all as specified and as directed.
Material & Labour of machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match shade of slab iuncl rubbing and polishing over 15mm thick screed bed layer in CM (1:6) complete all as specified and as directed.
Taking down cement plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. and removal outside of MOD land complete all as specified and as directed.
Material and labour for Rendering 15mm thick plaster in Cement Mortar (1:4) on fair faces of brick or concrete surface of wall and finished even and smooth without using extra cement, with water proofing treatment complete all as specified and as directed.. Note:- Water proofing compound shall be measure and paid separately
Material and labour for Preparation of new surface and applying two coats of 1st quality acrylic washable distemper (ready mixed) having VOC content less than 50 gms/litre of required colour shade and as per manufacturer’s specification over a coat of primer over a coat of 1.5 mm thick cement base wall putty complete all as specified and directed.
Taking down chowkats/frames with shutters (without taking off shutters from the frame) etc. exceeding 1.50 Sqm but not exceeding 4.00 Sqm each complete all as specified and as directed.
Supply and fixing of 35 mm thick flush shutters, solid core construction, with block board core and comercial plywood face panels with one face is covered with decorative face veneer with lipping/frame to match all complete all as specified and as directed.
Material and labour for Aluminium anodised barrel tower bolts of extruded section size 200 mm complete all as specified and directed.
Material and labour for Butt hinges Stainless steel 100 mm size complete all as specified and directed.
Material and labour for Aluminium anodised barrel tower bolts of extruded section size 200 mm complete all as specified and directed.
Material and labour for Aluminium anodised sliding door bolt, with hasp & staple (bolt type) and fixing clips of sheet, cast of extruded sections and fixing bolts and sliding bolts of extruded sections 300 mm long .complete all as specified and as directed.
Material and labour for Floor door stopper of SS body and tongue, anodised, with hard drawn steel spring of size 150 mm, fixed in floor complete all as specified and directed.
Material and labour for Aluminium handles cast type anodised 150 mm size complete all as specified and directed.
Dismantling timber scantling 40 Sqcm and over in section, in any position (Unframed work) complete all as specified & as directed.
Dismantling Boarding, any description, fixed in any Position with Nails, complete all as specified and as directed.
Material and labour for Second class hardwood in scantling, timber fixed, clean sawn complete all as specified and directed.
Material and labour for 6 mm thick plywood, grade BWP, type BB fixed with screws to timber frame work complete all as specified and directed.
Mild steel work as in bands, straps, supports or stays for RWP, ventilating pipes, clamps, hold fasts, wall ties conforming to Fe-290 Gde E-165
Chamfers, splays, grooves, rebates,rounded angles, rounded nosings, tongued and grooved edges (each tongue and each groove measured) mouldings exc 3mm but n. exc 75mm girth on softwood
Material and labour for Painting 2 coats of synthetic enamel paint on wooden surfaces of any description over 10 cm in width or girth including preparation new surface and one coat of pink primer complete all as specified and as directed.
Material and labour for non skid ceramic coloured, 7 to 8 mm thick (square / rectangular ) area of each tiles exceeding 0.18 sqm but n exc. 0.36 sqm , in floor etc. set and jointed in neat cement slurry and pointed in colour cement to match shade of tiles and laid over & incl 15 mm thick screed bed in CM (1:4 ) complete all as specified and directed.
Material & Labour Glazed ceramic tiles 450x300/350x250 x7 mm(Coloured) on vertical surfaces such as skirting, dados and riser to steps etc. set and jointed in neat cement slurry and pointed in coloured cement to match complete over 10mm thick screed bed vertical layer in CM (1:4)all as specified and as directed.
Subtotal of Sch A part-I
SCHEDULE 'A' PART - II FOR B/R PORTION (Sl No __ to ____)
Taking down carefully unserviceable copper / aluminium point wiring (light, fan, bell socket or power) including all fittings such as switches, socket, ceiling roses , regulators and switch boxes etc complete and making good the disturbed surfaces complete all as specified and as directed.
Material and labour for point wiring with PVC insulated unsheated stranded copper conductor cable of size 1.5 sq mm in and including PVC cassing caping of required width with all necessary fittings with sunk cast iron /pressed steel terminal box of1.6mm wall thickness and 3 mm thick laminated sheet top cover for mounting switches including 1.5 sq mm PVC insulated unsheathed stranded copper conductor as earth lead and connected to common earth doly for one light / ceiling fan/exhaust fan/bell controlled by one switch complete all as specified and directed by engineer incharge.
All as per item No-33 above but for one 5 amp socket independent complete all as specified and as directed.
All as per item No-33 above but 3 pin 5 amps socket out let point and 5 amps light point with the same board with other suitable complete all as specified and as directed.
Material and labour for point wiring with 2.5 Sq. mm (nominal area) PVC insulated and unsheathed single core FRLSH copper cable 1100 volts grade with multi-stranded copper conductor in and including double lock casing caping and accessories alongwith continuous earth wire 2.5 Sq mm PVC insulated and unsheathed single core FRLSH cable 1100 volts grade with stranded copper conductor and connected to common earth dolly, with and including 1.6 mm thick cadmium plated sunk MS pressed steel terminal boxes with 3 mm thick plastic laminated sheet cover fixed with brass screws complete for one socket outlet 6pin15/16 amps on independent board complete all as specified and directed.
Supply and fixing of switch piano flush single pole one way 5 amps complete all as specified and as directed.
Supply and fixing socket out let 3 pin 5 Amps flush type complete all as specified and as directed.
Supply and fixing switch socket outlet multipurpose 3 pin 15 Amps /5 Amps controlled by one switch.
Supply and fixing of switch socket outlet 3 pin 6 Amps 230 volts flush type complete all as specified and as directed.
Supply and fixing ceiling rose surface bakelite 65x50mm three terminals complete all as specified and as directed.
Supply and fixing of LED surface/ceiling mounting(suspended from ceiling) box type light fitting 20Watt with LED Lamp , drive and made of epoxy powder coated extruded aluminium channel housing with high quality polycarbonate opal diffuser cover & high power LED’s as light source with 120 Lumen per watt (Minimum) and including all other standard accessories as per manufacture instructions ,internally pre-wired including connecting up three core 1.00sq. mm copper conductor flexible wire/cable complete all as specified. Make : Model No CIS-305-40-57-SL-DP-NWH of Crompton or equivalent model of make list as given in PS as approved by GE.
Supply , Fixing of LED street light fitting ( Building Security light) of 30Watt with LED lamp’s & driver and made of pressure die-cast aluminum housing, IP 65/IP 66 road way luminaries with UV stabilized polycarbonate cover or toughen glass cover & high power LED’s as light source with 110 Lumen per watt and electronic driver with efficiency > 85% . The light fitting shall be fixed on wall/pole with and including 25 mm dia( or higher size as per manufacturers recommendation) light grade GI pipe (bend to shape or as per manufacturers recommendation ) bracket 1.5 mtr long complete with MS flat iron clamp (clamps shall be 40 x 5 mm MS flat) nuts, bolts & washers including painting the clamps with two coat of aluminium paint over a coat of red oxide primer and including taking up old light fitting complete all as specified and as directed Make:- Model No- LSTM-30-CDL M of Crompton Greave or equivalent model of make list as given in PS as approved by GE. Note for items no 42 to 43 : (i) Warranty of complete LED luminaries fitting shall not less than four years and Life expectancy of LED's minimum 50,000 burning hrs,. (ii)The contractor shall be submitted the LM-79 third party NABL accredited lab test report and LM-80 test certificate and LED has to be stractured in the same sequence.
Supply and fixing of sheet metal enclosure for MCBs to be used singal pole & nutral double door 8 Way 200 Amps rated busbar and including fixed with 25mm x 6 mm mild steel clamp of suitable length and including taking out old DB complete all as specified and as directed.
Supply and fixing of MCB SP of rating 6 to 32 Amps 240 V complete all as specified and as directed.
Supply and fixing MCB DP 40 to 63 amps 415 volts 10KA breaking capacity.
Supply and fixing of sub main wiring with two single core 6.0sqmm (nominal area) PVC insulated copper conductor FRLSH, multi stranded, unsheathed 1100 volts grade IS-694 marked in PVC conduit and accessories accessories including one single core 6.0sqmm copper conductor cable FRLSH as earth wire and including taking out old sub-main wiring complete all as specified and as directed. NOTE:- (a) All runs of copper conductor and one run of conduit shall be measured as one run length.
Earthing as in repair complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below ground level connetced with earthing wire 4.0mm dia as earthing lead by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 15 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 Mtr etc all as shown on electrical plate No. 5 of MES Schedule Part-I complete including testing on completion. On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
Excavating in trenches n. exc 1.5m wide and not e. 1.5m in depth for foundation of poles, laying under ground cables, etc and getting out in soft/loose soil complete as specified and directed.
Returning, filling in, including spreading leveling watering and well ramming in layers not exc 25 cm as in soft / loose soil complete as specified and directed.
Removing excavated material not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point in soft / loose soil complete as specified and directed.
Material & Labour of sand cushioning to the full width of trenches for protection of cables including punning down complete all as specified. Note :- Thickness of sand cushioning shall be measure after punning down.
Supplying and laying of brick for cable protection complete all as specified and directed.
Supply, fixing and repair of Galvanised steel tubing, light grade, with fittings and MS clamps, nuts, bolts etc of 40 mm dia bore for cable protection on pole, road crossing or ground in pillars for fixing gate light etc complete all as specified.
Supplying, laying, jointing with aluminium lugs and testing XLPE screened, PVC bedded, galivanised steel strip or wire aroured, electric power cables (heavy duty with aluminium conductor, 1100 volts grade of size 10 Sqmm 2.0 core complete all as directed.
Note: Schedule of credit (SCHEDULE OF CREDIT) amount of Rs ₹ ___________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ.
M/S P.G CONSTRUCTION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .