Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
26 Nov 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
GE Utility Electric Supply
GE Utility Electric Supply DELHI CANTT-10
FAULT FINDING IN HT LT CABLES INCLUDING REPAIR REPLACEMENT REROUTING AND SHIFTING OF FAULTY DAMAGED 11 KV TO 0 220KV HT LT CABLES WITH STRAIGHT THROUGH/END JOINTS REPAIRS REPLACEMENT OF STREET LIGHTS TIMERS CONTACTORS AND CONNECTED ITEMS AT SHANKAR
2026_MES_797404_1
GE ELECT/TOKEN-63/2026-2027
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE Utility Electric Supply
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
GE Utility Electric Supply
₹96,000
5 Nov 2026
5 Nov 2026
28 Nov 2026
5 Nov 2026
26 Nov 2026
19 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Testing the cables with high voltage DC testing machine and locating the fault in the cables as well as tracing of unidentified route of 33 KV HT cable by fault locating machine to trace out pin point exact position of fault. Disconnecting faulty 33 KV HT cables of different sizes from both ends as well as at two pole structure (where available) and reconnecting after removal of Fault complete all as specified and directed by Engineer-in-Charge.
Note: (a) 33 KV HT cable & joints shall be measured and paid for seperately under respective items of schedule.
(b) Excavation and earth work will be measured and paid for seperately under respective items of schedule. (c) T & P and labour for rectification of fault shall be provided by the contractor & cost is deemed in the item rate.
(d) PCC cable Cover shall be paid separately.
(e) Fault to the contractor wiil be intimated vide phone/e-mail /whatsapp.The Contrator has to rectify the fault within 12 Hrs ,failure of the contractor to attend the fault beyond 12 Hrs , a penalty of Rs. 1000/Hrs will be recovered , fault will be retified by the other contractor /vendor under Risk & Cost by deducting the rectification cost / cost as finalised by the accepting officer with penalty from the work done. | 15 | Each Job | - | - |
| 2 | Supply, laying, jointing and testing in assorted piece/ Sizes of 8 to 10 mtr length towards cable faults/ joint replacement /insulation break down for making straight through joints where cable loops are not available towards rectification of cable faults, XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured electric HT power cable (heavy duty) with multistranded aluminium conductors of sizes 3 Core, 300 to 400 Sqmm,33 KV grade (earth) system, laid in trenches/ ducts /encased in G.I. pipe/CI Pipe/fixed to pole including testing complete all as specified and directed by Engineer-in-Charge. | 50 | RM | - | - |
| - | Material & Labour for complete jointing and testing, straight through joint, heat shrinkable type, suitable for HT, 33 KV (E) XLPE aluminium stranded conductors cable 3 core, 300 to 400 Sqmm cables, against joint failures & breakdown /damages, including taking out faulty pieces of cable from any depth of trenches and relaying properly after completeion of jointing as well as refixing of existing cable route indicater (where available).Excavation and earth work will be measured and paid for seperately under respective items of schedule complete all as specified and directed by Engineer-in-Charge. | 22 | Each Job | - | - |
| - | Material and labour for supply jointing and testing,outdoor end termination heat shrinkable type joint , suitable for HT, 33 KV (E) XLPE cables, aluminium stranded conductors cable 3 core, 300 to 400 Sqmm. including taking out of cable from any depth of trenches and relaying properly after completeion of jointing. Note : Excavation and earth work will be measured and paid for seperately under respective items of schedule complete all as specified and directed by Engineer-in-Charge. | 10 | Each Job | - | - |
| - | Testing the cables with high voltage DC testing machine and locating the fault in the cables as well as tracing of unidentified route of 11 KV HT cable by fault locating machine to trace out pin point exact position of fault. Disconnecting faulty 11 KV HT cables of different sizes from both ends as well as at two pole structure (where available) and reconnecting after removal of Fault complete all as specified and directed by Engineer-in-Charge.
Note: (a) 11 KV HT cable & joints shall be measured and paid for seperately under respective items of schedule.
(b) Excavation and earth work will be measured and paid for seperately under respective items of schedule.
(c) T & P and labour for rectification of fault shall be provided by the contractor & cost is deemed in the item rate.
(d) PCC cable Cover shall be paid separately.
(e)Fault to the contractor wiil be intimated vide phone/e-mail /whatsapp.The Contrator has to rectify the fault within 12 Hrs ,failure of the contractor to attend the fault beyond 12 Hrs , a penalty of Rs. 1000/Hrs will be recovered , fault will be retified by the other contractor /vendor under Risk & Cost by deducting the rectification cost with penalty from the work done. | 45 | Each Job | - | - |
| - | Supply and Laying in assorted piece/ Sizes of 8 to 10 mtr length towards cable faults/ joint replacement /insulation break down for making straight through joints where cable loops are not available towards rectification of cable faults, laying, jointing and testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured electric HT power cable (heavy duty) with multistranded aluminium conductors of the following cable sizes,11 KV grade (earth) system, laid in trenches/ ducts /encased in G.I. pipe/CI Pipe/fixed to pole including testing complete all as specified and directed by Engineer-in-Charge. | - | - | - | - |
| - | 3 core 300 Sq mm | 120 | RM | - | - |
| - | 3 core 240 Sqmm | 60 | RM | - | - |
| - | 3 core 185 Sq mm | 50 | RM | - | - |
| - | 3 core 120 Sq mm | 50 | RM | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
TD63.pdf
Tender Documents • 0.76 MB
BOQ_894459.xls
BOQ • 6.43 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .