Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹9.1 LAccepted-AOC 535 UDYOG VIHAR PHASE V GURUGRAM HARYANA 122016 | ₹9.1 L | 1 | Accepted-AOC Firm is L1 Bidder |
| 2 | 2₹9.2 L+₹9,384.92 (1.03%)Rejected-Finance NO 40 3RD FLOOR UNIPUNCH PRIDE SECOND MAIN ROAD AMBATTUR INDUSTRIAL ESTATE AMBATTUR TIRUVALLUR TAMIL NADU 600058 INDIA | CHENNAI | TAMIL NADU | 600058 | ₹9.2 L+₹9,384.92 (1.03%) | 2 | Rejected-Finance 2 |
| 3 | 3₹9.4 L+₹29,034.58 (3.19%)Rejected-Finance | ₹9.4 L+₹29,034.58 (3.19%) | 3 | Rejected-Finance 3 |
| 4 | 4₹12.3 L+₹3.2 L (35.7%)Rejected-Finance | ₹12.3 L+₹3.2 L (35.7%) | 4 | Rejected-Finance 4 |
| 5 | 5₹12.8 L+₹3.7 L (41.0%)Rejected-Finance 5 B 2 1ST FLOOR OPP METRO PILLOR 484 TILAK NAGAR DELHI 110018 | WEST | DELHI | 110018 | ₹12.8 L+₹3.7 L (41.0%) | 5 | Rejected-Finance 5 |
Tender Value
₹14.7 L
EMD Value
₹30,000
Closing Date
12 Mar 2026, 11:00 amClosed
EEE/CNZ
EEE/CNZ
Provision of retrofit emission control devices (RECD) on DG sets of various capacities under AE(E and M)-I Central Zone MCD
2026_MCD_268910_1
EE (EandM/AUTO)-II/ MCD/ 2025-26/30.1
Open Tender
Electrical Works
Percentage
60 days
EEE/CNZ
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
₹30,000
8 Jul 2026
26 Feb 2026
13 Mar 2026
26 Feb 2026
12 Mar 2026
26 Feb 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.001 | Supply installation testing and commissioning of Retrofit Emission Control Device (RECD), applicability for phase I Genset of Capacity 30 Kva to reduce particulate Matter (PM), Hydrocarbon and carbon monoxide emission by not less than 70% in 5 mode D2 cycle. working technology of RECD should be based on Catalytic conversion technology and outer casing of RECD should be made of SS-409. The RECD should be type approved as per the system and procedure of central pollution Control Board for emission Compliance testing of Retro fit emission control devices (RECD) for diesel power Generating set engine dated 01/02/2022, vide pollution control series PCLS/12/2021-22. RECD to be type tested for equivalent Kva rating from any one for the central pollution control board, Govt of india recognized/ approved test agencies as given below Kva rating from any one for the central pollution control board, Govt of india recognized/ approved test agencies as given below:
(a) Automotive Research Association of India (ARAI, Pune)
(b) International Centre for Automotive testing (ICAT Manesar
(c) India Institute of petroleum (IIP Dehradun)
(d) Vehicle research Development Establishment (VRDE, Ahmadnagar).
Note:- RECD should not consume additional electricity/power either from the main supply or DG set for emission reduction, RECD should installed on top of the DG sets, with available space complete all as required at site | 1 | Each | 1,23,600 | ₹1,23,600 |
| 2.001 | Supply installation testing and commissioning of Retrofit Emission Control Device (RECD) applicability for phase II Genset of Capacity 82.5 Kva to reduce particulate Matter (PM), Hydrocarbon and carbon monoxide emission by not less than 70% in 5 mode D2 cycle. working technology of RECD should be based on Catalytic conversion technology and outer casing of RECD should be made of SS-409. The RECD should be type approved as per the system and procedure of central pollution Control Board for emission Compliance testing of Retro fit emission control devices (RECD) for diesel power Generating set engine dated 01/02/2022, vide pollution control series PCLS/12/2021-22. RECD to be type tested for equivalent Kva rating from any one for the central pollution control board, Govt of india recognized/ approved test agencies as given below:
(a) Automotive Research Association of India (ARAI, Pune)
(b) International Centre for Automotive testing (ICAT Manesar
(c) India Institute of petroleum (IIP Dehradun)
(d) Vehicle research Development Establishment (VRDE, Ahmadnagar).
Note:- RECD should not consume additional electricity/power either from the main supply or DG set for emission reduction, RECD should installed on top of the DG sets, with available space complete all as required at site | 3 | Each | 2,47,475 | ₹7,42,425 |
| 3.001 | Supply installation testing and commissioning of Retrofit Emission Control Device (RECD)applicability for phase I Genset of Capacity 125 Kva to reduce particulate Matter (PM), Hydrocarbon and carbon monoxide emission by not less than 70% in 5 mode D2 cycle. Working technology of RECD should be based on Catalytic conversion technology and outer casing of RECD should be made of SS-409. Monitoring system of RECD shall have touchable digital display.The RECD should be type approved as per the system and procedure of central pollution Control Board for emission Compliance testing of Retro fit emission control devices (RECD) for diesel power Generating set engine dated 01/02/2022, vide pollution control series PCLS/12/2021-22. RECD to be type tested for equivalent Kva rating from any one for the central pollution control board, Govt of india recognized/ approved test agencies as given below:
(a) Automotive Research Association of India (ARAI, Pune)
(b) International Centre for Automotive testing (ICAT Manesar
(c) India Institute of petroleum (IIP Dehradun)
(d) Vehicle research Development Establishment (VRDE, Ahmadnagar).
Note:- RECD should not consume additional electricity/power either from the main supply or DG set for emission reduction, RECD should installed on top of the DG sets, with available space complete all as required at site | 1 | Each | 2,70,330 | ₹2,70,330 |
| 4.001 | Supply installation testing and commissioning of Retrofit Emission Control Device (RECD) applicability for phase I Genset of Capacity 180 Kva to reduce particulate Matter (PM), Hydrocarbon and carbon monoxide emission by not less than 70% in 5 mode D2 cycle. working technology of RECD should be based on Catalytic conversion technology and outer casing of RECD should be made of SS-409.The RECD should be type approved as per the system and procedure of central pollution Control Board for emission Compliance testing of Retro fit emission control devices (RECD) for diesel power Generating set engine dated 01/02/2022, vide pollution control series PCLS/12/2021-22. RECD to be type tested for equivalent Kva rating from any one for the central pollution control board, Govt of india recognized/ approved test agencies as given below:
(a) Automotive Research Association of India (ARAI, Pune)
(b) International Centre for Automotive testing (ICAT Manesar
(c) India Institute of petroleum (IIP Dehradun)
(d) Vehicle research Development Establishment (VRDE, Ahmadnagar).
Note:- RECD should not consume additional electricity/power either from the main supply or DG set for emission reduction, RECD should installed on top of the DG sets, with available space complete all as required at site | 1 | Each | 3,30,038 | ₹3,30,038 |
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.19 MB
Direction_No_768.pdf
Tender Documents • 2.70 MB
General_Condition1.pdf
Tender Documents • 0.15 MB
DNIT_1.pdf
Tender Documents • 0.22 MB
MCD_GCC.pdf
Tender Documents • 9.26 MB
RECD_Procedure_Revised.pdf
Tender Documents • 2.07 MB
corrigendum_GCC.pdf
Tender Documents • 0.30 MB
BOQ_312979.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .