Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹16,300Qualified Make: FLUKE
Model: FLUKE-17B+ 506 701 SIDDARTH BUILDING 96 NEHRU PLACE NEW DELHI 110019 | NEW DELHI | NEW DELHI | DELHI | 110019 | Make: FLUKE
Model: FLUKE-17B+ | L1 | Qualified | |
| 2 | L2₹16,400+₹100 (0.61%)Qualified Make: FLUKE
Model: Fluke 17 B+ 122 KANCHAN BAGH KANCHAN BAGH KANCHAN BAGH INDORE MADHYA PRADESH 452001 | INDORE | MADHYA PRADESH | 452001 | Make: FLUKE
Model: Fluke 17 B+ | L2 | Qualified | |
| 3 | L3₹18,200+₹1,900 (11.7%)Qualified Make: FLUKE
Model: FLUKE 17B+ 7 MB 250 I G NAGAR JAIPUR JAIPUR JAIPUR CITY SOUTH RAJASTHAN 302025 | 302025 | Make: FLUKE
Model: FLUKE 17B+ | L3 | Qualified | |
| 4 | L4₹25,000+₹8,700 (53.4%)Qualified Make: FLUKE
Model: FLUKE 17B+ 00 BALAJI ENTERPRISES NEW ROAD NEW ROAD RATLAM MADHYA PRADESH 457001 | RATLAM | MADHYA PRADESH | 457001 | Make: FLUKE
Model: FLUKE 17B+ | L4 | Qualified | |
| 5 | L4₹25,000+₹8,700 (53.4%)Qualified Make: FLUKE
Model: Fluke 17B+ 66 2ND CROSS STREET PALLAVAN NAGAR EXT MADURAVOYAL CHENNAI PORUR TIRUVALLUR TAMIL NADU 600095 | CHENNAI | TAMIL NADU | 600095 | Make: FLUKE
Model: Fluke 17B+ | L4 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
31 Jul 2018, 2:00 pmClosed
digital multimeter Digital Multimeter ( 2 ) Technical Specifications Specification Specification Name Values Allowed Values FEATURES Type Hand Held Hand Held
Benchtop Display (Digits) 3.5 3.5
4.5
6.5 Measurement Type Average Average
True RMS Counts 4000 4000
6000
50000
2000 00 MEASUREMENTS DC Voltage Range 1000 600
1000 DC Voltage Accuracy 0.5 0.005
0.05
0.1
0.5
1 DC Voltage resolution 100 0.001
0.01
1
10
10 0 AC Voltage Range 1000 600
1000 AC Voltage Accuracy 1 0.08
1 AC Voltage resolution 100 0.001
10 0 DC Current Range 10 3
10 DC Current Accuracy 1.5 0.005
1.5 DC Current resolution 100 0.001
10 0 AC Current Range 10 3
10 AC Current Accuracy 1.5 0.5
1.5 AC Current resolution 100 0.001
10 0 1/5 Resistance Range 40 40
50
60
100
500 Resistance Accuracy 1.5 0.08
1.5
2
2.5
3
3.5 Resistance resolution 100 0.001
10 0 Capacitance Range ( Micro farad ) .01 to 1000 1 to 100
1 to 200
.01 to 1000
NA Capacitance Accuracy ( % ) 5 1.5
3.5
5
NA Capacitance resolution ( nF ) 100 0.001
10 0
NA Frequency Range ( KHz ) 100 50
200
300
NA Frequency Accuracy ( % ) 1 0.1
NA Frequency resolution ( Hz ) 100 0.001
NA Temperature Range ( Degree C ) -50 to 1000 -40 to 400
50 to 1000
NA Temperature Accuracy ( % ) 2 1.5
NA Temperature resolution ( Degree C ) 100 0.001
NA OTHER FEATURES Continuity test and Diode test Available - Data logging Available - If Data Logging Feature is Available
Internal Memory min. 5000 points/200 readings - Computer Interface along with software Available - Dimensions ( mm X mm X mm ) 183 mm x 91 mm x 49.5mm - Weight 455 - Other Features AS PER OEM - SAFETY Safety Rating Category III 600 V of IEC 61010. Category II 600 V of IEC 61010.
Category II 1000 V of IEC 61010.
Category III 600 V of IEC 61010.
Category III 1000 V of IEC 61010.
Category IV 600 V of IEC 61010
Category IV 1000 V of IEC 61010 2/5 Safety Certification UL
CE
CSA
TUV
VDE - POWER REQUIREMENTS Power Requirements Battery Operated - if Battery Operated
then Type of Battery Non- Rechargeable (Alkaline) - if rechargeable
then chemistry of the battery NA - if Non-rechargeable
then size of the battery cell AA - number of non- rechargeable the battery/cell 2 - Voltage of rechargeable Battery 0 - capacity of rechargeable battery(milli Ampere Hour) 0 - Suitable charger adaptor provided YES - ACCESSORIES Standard Accessories Supplied with the Equipment as per OEM - WARRANTY Warranty 1 1
5 OPERATING CONDITION Minimum Operating Temperature -20 - Maximum Operating Condition 70 - Operating Humidity (RH) 95 - TEST REPORT DETAILS The equipment supplied with calibration certificate YES - conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:900 0/part-3/section-5/1977 latest true - conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:900 0/part-2/section-4/1977 latest true - conformity to Damp Heat (Cyclic)Test for 2 true - 3/5 Cycles of 24 hrs each at a temp of 40 degree C & 95% RH Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification true - Test Report Number and date for the specification test NABL/FLUKE107/CAL01 0659 - 01-08-2017 - Name and address of the Lab for the specification test NABL BANGALORE - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Manish Kumar 145001
C/O AOC
ATG Section
Air Force Station
Pathankot 2 15
396071
GEM/2018/B/56058
digital multimeter
15 days
Punjab; Pathankot
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| digital multimeter Digital Multimeter ( 2 ) Technical Specifications Specification Specification Name Values Allowed Values FEATURES Type Hand Held Hand Held | - | - | - |
| Benchtop Display (Digits) 3.5 3.5 | - | - | - |
| 4.5 | - | - | - |
| 6.5 Measurement Type Average Average | - | - | - |
| True RMS Counts 4000 4000 | - | - | - |
| 6000 | - | - | - |
| 50000 | - | - | - |
| 2000 00 MEASUREMENTS DC Voltage Range 1000 600 | - | - | - |
| 1000 DC Voltage Accuracy 0.5 0.005 | - | - | - |
| 0.05 | - | - | - |
| 0.1 | - | - | - |
| 0.5 | - | - | - |
| 1 DC Voltage resolution 100 0.001 | - | - | - |
| 0.01 | - | - | - |
| 1 | - | - | - |
| 10 | - | - | - |
| 10 0 AC Voltage Range 1000 600 | - | - | - |
| 1000 AC Voltage Accuracy 1 0.08 | - | - | - |
| 1 AC Voltage resolution 100 0.001 | - | - | - |
| 10 0 DC Current Range 10 3 | - | - | - |
| 10 DC Current Accuracy 1.5 0.005 | - | - | - |
| 1.5 DC Current resolution 100 0.001 | - | - | - |
| 10 0 AC Current Range 10 3 | - | - | - |
| 10 AC Current Accuracy 1.5 0.5 | - | - | - |
| 1.5 AC Current resolution 100 0.001 | - | - | - |
| 10 0 1/5 Resistance Range 40 40 | - | - | - |
| 50 | - | - | - |
| 60 | - | - | - |
| 100 | - | - | - |
| 500 Resistance Accuracy 1.5 0.08 | - | - | - |
| 1.5 | - | - | - |
| 2 | - | - | - |
| 2.5 | - | - | - |
| 3 | - | - | - |
| 3.5 Resistance resolution 100 0.001 | - | - | - |
| 10 0 Capacitance Range ( Micro farad ) .01 to 1000 1 to 100 | - | - | - |
| 1 to 200 | - | - | - |
| .01 to 1000 | - | - | - |
| NA Capacitance Accuracy ( % ) 5 1.5 | - | - | - |
| 3.5 | - | - | - |
| 5 | - | - | - |
| NA Capacitance resolution ( nF ) 100 0.001 | - | - | - |
| 10 0 | - | - | - |
| NA Frequency Range ( KHz ) 100 50 | - | - | - |
| 200 | - | - | - |
| 300 | - | - | - |
| NA Frequency Accuracy ( % ) 1 0.1 | - | - | - |
| NA Frequency resolution ( Hz ) 100 0.001 | - | - | - |
| NA Temperature Range ( Degree C ) -50 to 1000 -40 to 400 | - | - | - |
| 50 to 1000 | - | - | - |
| NA Temperature Accuracy ( % ) 2 1.5 | - | - | - |
| NA Temperature resolution ( Degree C ) 100 0.001 | - | - | - |
| NA OTHER FEATURES Continuity test and Diode test Available - Data logging Available - If Data Logging Feature is Available | - | - | - |
| Internal Memory min. 5000 points/200 readings - Computer Interface along with software Available - Dimensions ( mm X mm X mm ) 183 mm x 91 mm x 49.5mm - Weight 455 - Other Features AS PER OEM - SAFETY Safety Rating Category III 600 V of IEC 61010. Category II 600 V of IEC 61010. | - | - | - |
| Category II 1000 V of IEC 61010. | - | - | - |
| Category III 600 V of IEC 61010. | - | - | - |
| Category III 1000 V of IEC 61010. | - | - | - |
| Category IV 600 V of IEC 61010 | - | - | - |
| Category IV 1000 V of IEC 61010 2/5 Safety Certification UL | - | - | - |
| CE | - | - | - |
| CSA | - | - | - |
| TUV | - | - | - |
| VDE - POWER REQUIREMENTS Power Requirements Battery Operated - if Battery Operated | - | - | - |
| then Type of Battery Non- Rechargeable (Alkaline) - if rechargeable | - | - | - |
| then chemistry of the battery NA - if Non-rechargeable | - | - | - |
| then size of the battery cell AA - number of non- rechargeable the battery/cell 2 - Voltage of rechargeable Battery 0 - capacity of rechargeable battery(milli Ampere Hour) 0 - Suitable charger adaptor provided YES - ACCESSORIES Standard Accessories Supplied with the Equipment as per OEM - WARRANTY Warranty 1 1 | - | - | - |
| 5 OPERATING CONDITION Minimum Operating Temperature -20 - Maximum Operating Condition 70 - Operating Humidity (RH) 95 - TEST REPORT DETAILS The equipment supplied with calibration certificate YES - conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:900 0/part-3/section-5/1977 latest true - conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:900 0/part-2/section-4/1977 latest true - conformity to Damp Heat (Cyclic)Test for 2 true - 3/5 Cycles of 24 hrs each at a temp of 40 degree C & 95% RH Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification true - Test Report Number and date for the specification test NABL/FLUKE107/CAL01 0659 - 01-08-2017 - Name and address of the Lab for the specification test NABL BANGALORE - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Manish Kumar 145001 | - | - | - |
| C/O AOC | - | - | - |
| ATG Section | - | - | - |
| Air Force Station | - | - | - |
| Pathankot 2 15 | - | - | - |
Exempted
31 Jul 2018
28 Jul 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_396071.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .