Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.0 LAccepted-AOC | L1 | Accepted-AOC Being Lowest L1 | |
| 2 | L2₹19.8 L+₹2.3 L (13.0%)Rejected-Finance 225 NAROT COLONY MODEL TOWN PATHANKOT PB 145001 | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹23.5 L+₹6.0 L (34.3%)Rejected-Finance 1ST FLOOR GURJEET MARKET DHANGU ROAD | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹25.2 L+₹7.7 L (43.9%)Rejected-Finance I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹25.7 L+₹8.2 L (46.8%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
31 Aug 2021, 6:00 pmClosed
GE (AF) PATHANKOT
GE (AF) PATHANKOT-145001
REPAIR/ MAINTENANCE OF STREET LIGHT FITTINGS AND CONNECTED ITEMS AT AIR FORCE STATION PATHANKOT
2021_MES_464822_1
8420/GE/PAF-27/2021-22
Open Tender
Support/Maintenance Service
Item Rate
270 days
GE (AF) PATHANKOT
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) PATHANKOT
₹70,000
Yes
13 Oct 2021
3 Aug 2021
2 Sept 2021
3 Aug 2021
31 Aug 2021
17 Aug 2021
Amount
Excavation in trenches in any type of soil not exc 1.5 Mtr in width and not exc 1.5Mtr in depth and getting out for laying of cable complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches in any type of soil exc 1.5 Mtr in width andexc 1.5Mtr in depth and getting out for laying of cable complete all as specified and directed by Engineer-in-Charge.
Returning filling in, including spreading leveling,watering and well ramming in layers not exc 1.5cm each layer complete all as specified and directed by Engineer-in-Charge.
Removal of surplus soil to distance not exc 50mtr and depositing where directed at level not exc 1.5 mtr above the starting point complete all as required at site and directed by Engr-in-Charge.
Sand cushioning to underground cable 8cm thick before laying the cable and 15 cm thick after laying, stretching and testing the cable complete all as specifed and directed by Engr-in-Charge.
Reuse old Sub Class 'B' brick covering protection to the eletric cable laid dry flat transversally along the length of cable on sand cushioning with width equal to length of brick complete all as required at site and directed by Engr-in-Charge.
Sub class “B” bricks laid dry flat cover the cable with width equal to the length of cable, abutting each other for protection of cable complete all as required at site and directed by Engr-in-Charge.
Disconnecting electrically, taking out from trenches and removing from site/LT cable any size upto185sqmm 2/3.5 core.( Earth work will be measured seperatelly under respective items) complete all as specified and directed by Engr-in-Charge.
Relaying only LT cable taking out aganist item No- 08 above or passing through pipe 1100 volts grade heavey duty cable with PVC insulated multistand alumn conductor of size 6 to 240 Sqmm 2/3.5 core , armoured with galvanized steel strip or wire complete all as specified and directed by Engr-in-Charge.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 25 sq mm, 2 core complete all as specified and directed by Engr-in-Charge.
All as per item No. 10.00 above but of size 16 sq mm, 2 core complete all as specified and directed by Engr-in-Charge.
All as per item No. 10.00 above but of size 50 sq mm, 3.5 core complete all as specified and directed by Engr-in-Charge.
All as per item No. 10.00 above but of size 70 sq mm, 3.5 core complete all as specified and directed by Engr-in-Charge.
All as per item No. 10.00 above but of size 95 sq mm, 3.5 core complete all as specified and directed by Engr-in-Charge.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 185 sq mm, 3.5 core complete all as specified and directed by Engr-in-Charge.
Supply and fix LT cable jointing kit for 1100 V grade cable for end box heat shrink type joint complete with jointing material and accessories suitable for 2 core XLPE armoured Aluminium conductor cable of size 10-25 Sq mm 2 core complete all as specified and directed by Engr-in-Charge.
Supply and fix LT cable jointing kit for 1100 V grade cable for end joint indoor/outdoor heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured Aluminium conductor cable of size 95-240 Sq mm 3.5 core complete all as specified and directed by Engr-in-Charge.
Supply and fix MCCB 4 pole 415 volts with rupturing cap 16 KA , 100 Amps thermal magnetic release of all as required at site and complete all as specified and directed by Engr-in-Charge.
Supply and fix MCCB 3 pole 415 volts with rupturing cap 16 KA 63 Amps thermal magnetic release complete all as specified and directed by Engr-in-Charge.
Scraping of old paint from the street light steel tubular pole with out removing accessories and preparation of surfaces for repainting . Repainting the pole with one coat of alternative white and black straps of 30 cm each upto 1.5 mtr height using synthetic enamell paint .Repainting the remaining pole and clamps GI bkt etc above 1.5 mtr height by applying one coat of alumn paint all as required at site or directed.
Painting of street light PCC pole without removing accessories with one coat of alternative yellow and black straps of 30 cm each upto 1.5 mtr height using synthetic enamell paint .Colour washing the pole above 1.5 mtr height using snowcem of approved colour including painting the steel parts i.e clamps GI bkt etc by applying one coat of alumn paint all as required at site or directed.
Writing No of pole with letters/ figures of size not exc 30 mm with black paint on a yellow circle of dia 75 mm all as required and directed by Engr in Charge.
Supply & fix in repair pressure die-cast aluminium IP 65 cool white road way luminaire with high power LED as Light source with 72 Watt high power LED with inbuilt surge protection upto 5 kv including with suitable GI Pipe Bracket , double clamps complete with nut bolts with pole and 2.5 sqmm 3 core copper wire multistrand for connection from DB to Light complete all as specified and directed by Engineer-in-Charge.
Supply & fix PVC medium grade 20 mm conduit incl complete fitting and fixture i.e. bend , elebow, suitable for fixing arrangement all as specified and directed by Engr In Charge.
Supply & fix Steel 20 mm conduit incl complete fitting and fixture i.e. bend , elebow, suitable for fixing arrangement all as specified and directed by Engr In Charge.
Fixing only in truly vertical position steel tubular pole 9/11 mtr long any size issued under Schedule 'B' including painting with alternative yellow & black strips of 30 cm width upto 1.5 mtr above ground level and with one coat of alumn paint above 1.5 mtr complete all as specified and directed by Engineer-in-Charge. ( steel pole shall be issued under Sch 'B'.)
PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in benching including whethering slightly chamfered angles and finished exposed surfaces even and smooth including necessary form work for concrete eathing pit complete all as specified and directed by Engineer-in-Charge.
Supply & fix in repair pressure die-cast aluminium IP 65 cool white road way luminaire with high power LED as Light source with 60 Watt high power LEDwith inbuilt surge protection upto 5 kv including with suitable GI Pipe Bracket , double clamps complete with nut bolts with pole and 2.5 sqmm 3 core copper wire multistrand for connection from DB to Light complete all as specified and directed by Engineer-in-Charge.
Supply & fix in repair pressure die-cast aluminium IP 65 cool white flood Light luminaire with 80 to 90 Watt high power LED as light source SMD LED with inbuilt surge protection upto 5 kv including complete with nut bolts with pole and connection wire complete all as specified and directed by Engr-in-Charge.
Supply & fix in repair pressure die-cast aluminium IP 65 cool white road way luminaire with high power LED as Light source with 35 to 40 Watt high power LED with SMD LED aray with efficiency above 100 lm/W with inbuilt surge protection upto 5 kv including with suitable GI Pipe Bracket , double clamps complete with nut bolts with pole and 2.5 sqmm 3 core copper wire multistrand for connection from DB to Light complete all as specified and directed by Engr-in-Charge.
Supply & fix in repair pressure die-cast aluminium IP 65 cool white flood Light luminaire with 120 Watt high power LED as light source SMD LED with inbuilt surge protection upto 5 kv including with Bracket , double clamps complete with nut bolts with pole and connection wire complete all as specified and directed by Engr-in-Charge.
Supply and fixing 1100 volts grade heavy duty cable PVC insulated aluminiuim multistranded of size 16 Sqmm served with inner sheathing of PVC tape and overall PVC sheathed in service connections with one twin core cable flat or circular complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement MCB single pole 240 volts any rating from 5 to 30 amps, with rupturing capacity 10 KA,including providing thimble for out going cables complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement MCB single pole neutral 240 volts any rating 32 amps, with rupturing capacity 10 KA,including providing thimble for out going cables complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement compact flourescent lamp 65 watt asper required at site complete all as specified and directed by Engineer-in-Charge.
Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 120 sq mm, 3.5 core complete all as specified and directed by Engineer-in-Charge.
Earthing complete with galvanised steel earth plate electrode 600x600x6mm burried directly in ground not less than 2.25 mtr deep below normal ground level with top edge of earth plate not less than 1.5mtr below normal ground level connected to the Galvanised iron strip 32x6mm size by means of welding,bolts ,nuts,check nuts and washers of galvanised iron and 32x6mm GI strip procted by provision of GI light grade pipe 40 mm bore incl provision of concrete pit in PCC1:2:4 type B-I , using 20 mm graded stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg /Sqm and 6mm dia bar handle ,excavation and earth work in any type of soil ,charcoal dust and salt light grade GI watering pipe 20 mm bore with funnel and wire mashand medium grade GI protection pipe 15mm bore 5 Mtr long and GI strip upto main earthing of pole complete all as shown in electrical plate No 5 of MES Sch 2009 Part-I all as specified and directed .
Taking down the Carefully unserviceable any type security lights /perimeter light/Ballast & Hangers lights of any capaciy/size from pole/ bldgs/ walls light and refixing after repair unsv items such as choke/lamps/ignitors/ Surge protection, drivers complete all, as specified and directed by Engineer in Charge.(Lamp/ Choke/IgnitorsSurge protection, drivers measured and paid seperately) (Note:- (i) After completion of contract, contractor shall hand over all the security/perimeter lights conventional type" in perfect running/functioning condition to the department. (ii) Contractor shall provide his authorised Cell/mobile No. and local address to contact and communicate the message for any break down and contractor's rep will visit the office twice a day (0930 Hrs and 1430 Hrs) to collect the day to day complaints of any nature/type. (iii) Penalty for not rectifying the defect in time(within 72 hrs)will be charged to contractor and the amount of penalty @ Rs 500/- per complaint will deducted from the due payment of contract. (iv) Complaints will be treated as rectified only after user's "Satisfactory slip "will be produced by contractor to concerned JE E/M. (v) Cost of attending day by day complaint is included in the rate quoted under this item, no extra payment for attending complaint shall be made. (vi) Old material obtained from spares replaced under this item shall be contractor's property and will be measured as per credit schedule. (vii) Cost of minor spares i.e, wirnig inside light fittng, connecting wire upto terminal box, nut bolts washers or accessories as required for fixing light on pole, connector blocks are deemed to be included in the item rate, items other than mentioned will be measured and paid seperately under respective item of work, (viii) Cost of T&P i.e, ladders, tools, brazing, welding, soldering required and transportation is deemed to be included in quoted rates (ix) Area cleaning if required within vicininty of lighing poles is to be done by contractor only and rate for area cleaning is deemed to be included in quoted rates . (X) Contractor will be take proper shutdown before repaire with communation of IPSS team / Security section for repaire of perimeter lights.
Supply only following items 39.00 to 2.24 be fixed under Item No.38.00 above:- LED outdoor driver for 45 W LED light complete all as specified and directed by Engineer-In-Charge.
LED outdoor driver for 72 to 75 W LED flood/ street light complete all as specified and directed by Engineer-In-Charge.
Driver for 90 W LED flood/ street light complete all as specified and directed by Engineer-in-Charge.
LED outdoor driver for 150 W LED flood light complete all as specified and directed by Engineer-in-charge.
Voltage surge protection device for LED lights of wattage upto 75 W complete all as specified and directed by Engr-In-Charge.
Voltage surge protection device for LED lights of wattage 75W to 150 complete all as specified and directed by Engineer-in-Charge.
Street lights open construction heavy duty VPIT copper ballast for metal halide luminaries, 70 to 150 watts complete all as specified and directed by Engineer-In-Charge.
Street lights HPSV lamp tubular type 70 to 150 watts, single ended /double ended complete all as specified and directed by Engineer-In-Charge.
Street lights cable PVC insulated flexible copper conductor cable of size 2.5 Sqmm three core cut to pieces all as required, drawn into existing conduit/GI pipe of wall or pole complete all as specified and directed by Engineer-In-Charge.
Multifunctional digital Astro Rex3 D-21 including connecting electrically using copper conductor cable of appropriate size complete all as specified and directed by Engineer-In-Charge.
Air break contactor 3 pole 415 volts 50 Hz AC-3 duty, current rating 50 amps (normal life) with operating coil voltage 230 volts complete all as specified and directed by Engineer-In-Charge.
Air break contactor 3 pole 415 volts 50 Hz AC-3 duty, current rating 70 amps (normal life) with operating coil voltage 230 volts complete all as specified and directed by Engineer-In-Charge.
Air break contactor 3 pole 415 volts 50 Hz AC-3 duty, current rating 100 amps (normal life) with operating coil voltage 230 volts complete all as specified and directed by Engr-In-Charge
AC coil suitable for Power contactor 50 to 100 Amp exciting voltage 240/415 Volt complete all as specified and directed by Engr-In-Charge
Supply & fix in repair pressure die-cast aluminium IP 65 cool white flood Light luminaire with 150 Watt high power LED as light source with inbuilt surge protection upto 5 kv including with Bracket , double clamps complete with nut bolts with pole and connection wire complete all as specified by Engineer - in- charge.
Supplying, installing and commissioning of LT feeder box, outdoor type of size 0.90m x 0.60m x 0.50m, made out of MS sheet 3.15mm thick, legs made out of angle iron 40mmX40mmX6mm, 1.50m long (1.00m above ground level and 0.50m embedded in PCC (1:2:4), with openable shutter on both side (front and rear) having locking arrangement with 300 Amp rated aluminium bus bar suitable for 3 phase, 4 wire supply, drilled holes for cable connection, mounted on epoxy based post insulators and MCB SPN 63 Amps, 230 volts -03 No's, complete all as specified by Engineer - in- charge.
Supplying, installing and commissioning of LT feeder box, outdoor type of size 0.90m x 0.60m x 0.50m, made out of MS sheet 3.15mm thick, legs made out of angle iron 40mmX40mmX6mm, 1.50m long (1.00m above ground level and 0.50m embedded in PCC (1:2:4), with openable shutter on both side (front and rear) having locking arrangement with 300 Amp rated aluminium bus bar suitable for 3 phase, 4 wire supply, drilled holes for cable connection, mounted on epoxy based post insulators and MCCB 4 pole, 160 Amp, 415 volt, microprocessor release with rupturing capacity 36 KA, complete all as specified by Engineer - in- charge.
Supply/ Installing testing & commissioning of street Light Pole Box of 63 Amp single phase Two wire having two no Aluminium Bus Bar including 6 Amp SP MCB.The Box should have auto Door lock facility with magnetic lock having size 260X120X230 mm and fixed to poles/ Wall using MS strip of size 20x3mm and nuts & bolts of required size all as required at site or directed by Engr-in-charge.
Fixing only MCCB / Contractor any type & size with fixing arrangement complete all as specified by Engineer - in- charge.(MCCB will be issued under Sch B)
Earthing complete with galvanised cast iron earth plate electrode of size 600x600x6.3mm thick busied directly in ground less than 3.0m deep below normal ground level as earth electrode with top edge of the earth plate not less than 2.25mtr below ground level using GI wire 4mm dia as earth continuity conductor connected to earth plate by means of welding, GI thimbles, nuts, bolts & washers all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover with handle of angle iron frame of size 40 x 40 x 6mm in PCC 1:3:6 adequate quantity of charcoal dust and salt and kalmi shora all around the earth plate, earth work in any type of soil remaining surplus excavated material all as required at site and specified in EP No 5 of SSR part I 2009 or directed by Engineer-in-charge and incl testing on completion.
M/S SHRI RAM BUILDERS
Vijay Kumar Contractor and Engineers
SATISH AND CO
M/S Vijay Punj Constructions
M/S V K TRADERS
R K BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .