Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹3.1 LAdmitted-Finance | -11.27% | ₹3.1 L | L1 | Admitted-Finance |
| 2 | L2₹3.3 LAdmitted-Finance | -6.70% | ₹3.3 L | L2 | Admitted-Finance |
| 3 | L3₹3.3 LAdmitted-Finance | -6.01% | ₹3.3 L | L3 | Admitted-Finance |
| 4 | L4₹3.4 LAdmitted-Finance | -1.66% | ₹3.4 L | L4 | Admitted-Finance |
| 5 | Rejected-Technical | - | - | - | Rejected-Technical Non Responsive |
Tender Value
₹3.5 L
EMD Value
₹7,000
Closing Date
15 Jun 2026, 6:00 pmClosed
Executive Engineer (Electric)
PWD CAMPUS BHARATPUR
SITC of AC work in SGV Govt. Polytechnic College Building Distt Bharatpur.
2026_CEPWD_566437_1
NIT-05-2026-27
Open Tender
Electrical Works
180 days
BHARATPUR
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
As per NIT
₹7,000
Yes
Bharatpur
20 Jun 2026
10 Jun 2026
16 Jun 2026
10 Jun 2026
15 Jun 2026
10 Jun 2026
10 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1 | Supply , Installation, Testing and Commissioning of Inverter type Air cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R- 407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity up to 42 Degree Celsius ambient temperature. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 degree C (out door ambient temperature) | - | - | - | - | BI01010001010000000000000515BI0100001112 |
| 2 | Cooling capacity 5000-5300 Watt, ISEER not less then 3.8 | - | Each | - | - | BI01010001010000000000000515BI0100001113 |
| 3 | Supply, Fixing and testing of following capacity IS:8448 marked wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrial plug top making connection etc complete in all respect. | - | - | - | - | BI01010001010000000000000515BI0100001114 |
| 4 | 4 KVA | - | Each | - | - | BI01010001010000000000000515BI0100001115 |
| 5 | Supplying and drawing flexible / stranded bare copper conductor, PVC / XLPE insulated, overall aluminium mylar tape shielded ATC drain wire and outer PVC sheathed industrial Instrumentation (shielded)cables voltage grade 300/500 V as per BS /EN 50288-7 in existing surface or recessed PVC/ MS conduit/casing capping / Cable tray / Open Duct making connections, testing etc. as required. OEM must ensure that the cable is tested for complaince, either through their in house laboratory accrediated by NABL or by any Govt. laboratory accrediated by NABL and the laboratory's scope of accrediation should cover the requirements and testing procedure as per IS:10810. | - | - | - | - | BI01010001010000000000000515BI0100001116 |
| 6 | Un Armoured | - | - | - | - | BI01010001010000000000000515BI0100001117 |
| 7 | 4 core x 2.5 Sq.mm | - | mtr | - | - | BI01010001010000000000000515BI0100001118 |
| 8 | Supply, installation, testing and commissioning of interconnecting copper refrigerant piping of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink Mark Brand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified 'Class O' in Fire Propagation as per BS 476 Part 6 with 7 mil Glass Cloth and 3 coats of anti UV paint (on area which is exposed to weather) including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. | - | - | - | - | BI01010001010000000000000515BI0100001119 |
| 9 | 15.9 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) | - | mtr | - | - | BI01010001010000000000000515BI0100001120 |
| 10 | 6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) | - | mtr | - | - | BI01010001010000000000000515BI0100001121 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 11.09 MB
Annexure.pdf
Other Document • 1.72 MB
BOQ_1007800.xls
BOQ • 0.30 MB
06Month.pdf
Tender Documents • 4.40 MB
Download all tender documents and submit your bid