Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAccepted-AOC 1 AL SHEIKH COMPLEX 1ST FLOOR PEERBAGH CHOWK SRINAGAR PEERBAGH SRINAGAR BUDGAM JAMMU KASHMIR 190014 | BUDGAM | JAMMU AND KASHMIR | 190014 | ₹1.6 Cr Quoted ₹1.8 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹2.0 Cr+₹24.1 L (13.5%)Rejected-Finance | ₹2.0 Cr+₹24.1 L (13.5%) | L2 | Rejected-Finance Being other than lowest |
| 3 | L3₹2.1 Cr+₹26.9 L (15.0%)Rejected-Finance | ₹2.1 Cr+₹26.9 L (15.0%) | L3 | Rejected-Finance Being other than lowest |
| 4 | Rejected-Technical | - | - | Rejected-Technical Rejected because the bidder does not fulfill eligibility criteria as per Note-(a) on page-11 of NIT being three class below eligible class. |
Tender Value
₹1.6 Cr
EMD Value
₹2.4 L
Closing Date
18 Nov 2020, 6:00 pmClosed
CE 31 Zone
HQ CE 31 Zone Srinagar C/o 56 APO
COMPLETION OF INCOMPLETE WORKS OF PROVN OF SECURITY WALL AND ALLIED INFRASTRUCTURE ALONG COY GROUND AND EME BN IN DRUGMULLA GARRISON
2020_MES_377141_1
800107/2020/E8
Open Tender
Civil Works
Lump-sum
270 days
Drugmulla
As per NIT
10 documents required · 10 mandatory
₹1,000
GE 874 EWS
₹2.4 L
10 Dec 2020
28 Sept 2020
20 Nov 2020
28 Sept 2020
18 Nov 2020
26 Oct 2020
28 Sept 2020 - 9 Nov 2020
Amount
Notes: (i) Please refer Schedule 'A' Notes given on serial page No. 26 to33 of tender documents. (ii) Sch ‘A’ Part-I (Sec-I), Part-I (Sec-II), Part-II (Sec-II), Part-III (Sec-II), Part-IX (Sec-II), Part-XI, Part-XII and Part-XIII is not estimated by MES and the estimated rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
SCHEDULE 'A' PART-I (SEC-I): LIST OF WORKS FOR BUILDING WORKS
Construction of septic tank for 10 users (Brick masonary) including all other relevant works complete all as specified and shown on drawings
Construction of soakage well (Brick masonary) of size 1.2 metre internal dia and 3.00 metre deep below inlet pipe complete all as specified and shown on drawings
SCHEDULE 'A' PART-I (SEC-II): LIST OF WORKS FOR BUILDING WORKS
Completion of incomplete works of Construction of block of Security Post Type 'A' (Block No-1 EME near Main Gate) complete all as specified and shown on drawings
Completion of incomplete works of Construction of block of Security Post Type 'A' (Block No-2 EME near Main Gate) complete all as specified and shown on drawings
Completion of incomplete works of Construction of block of Security Post Type 'A' (Block No-3 EME Behind Building No P-106 ) complete all as specified and shown on drawings
Completion of incomplete works of Construction of block of Security Post Type 'A' (Block No-4 EME BEHIND NEW JCO CLUB ) complete all as specified and shown on drawings
Completion of incomplete works of Construction of block of Security Post Type 'A' (Block No-5 EME BEHIND NEW WK SHOP BLDG NEAR MES GATE ) complete all as specified and shown on drawings
Completion of incomplete works of Construction of block of Security Post Type 'B' (Block No-1 CVY GD MAIN GATE) complete all as specified and shown on drawings
Completion of incomplete works of Construction of block of Security Post Type 'B' (Block No-2 BETWEEN MH & CVY GD WALL ) complete all as specified and shown on drawings
Completion of incomplete works of Construction of block of Security Post Type 'B' (Block No-3 CVY GD REAR TOWARD MH WALL ) complete all as specified and shown on drawings
Completion of incomplete works of Construction of block of Security Post Type 'B' (Block No-4 CVY GD NEAR GD ROOM) complete all as specified and shown on drawings
Completion of incomplete works of Construction of block of Guard room for 10 ORs and JCO/NCO (Block No-1 EME Bn Gate) with toilets(Single Storey) including steps complete all as specified and shown on drawings
Completion of incomplete works of Construction of block of Guard room for 10 ORs and JCO/NCO (Block No-2 EME Bn Rear Gate) with toilets(Single Storey) including steps complete all as specified and shown on drawings
Completion of incomplete works of Construction of block of Guard room for 10 ORs and JCO/NCO (Block No-3 EME Bn behind MES) with toilets(Single Storey) including steps complete all as specified and shown on drawings
Completion of incomplete works of Construction of block of Guard room for 10 ORs and JCO/NCO (Block No-4 Convy Gd) with toilets(Single Storey) including steps complete all as specified and shown on drawings
Completion of incomplete works of Construction of mild steel gate 5.50 mtr wide (Gate No-1 CVY GD MAIN GATE) including 0.90 mtr wide wkt gate with RCC column (03 Nos) ans all other relevent work complete all as specified such as excavation in any type of soil, in concrete 1:4:8 type D2 in foundation RCC pillars MS angle iron for steel gate and removal of surplus soil completee all as specified and shown of drawings.
Completion of incomplete works of Construction of mild steel gate 5.50 mtr wide (Gate No-2 CVY GD MAIN GATE) including 0.90 mtr wide wkt gate with RCC column (03 Nos) ans all other relevent work complete all as specified such as excavation in any type of soil, in concrete 1:4:8 type D2 in foundation RCC pillars MS angle iron for steel gate and removal of surplus soil completee all as specified and shown of drawings.
Completion of incomplete works of Construction of mild steel gate 5.50 mtr wide (Gate No-3 MES MAIN GATE) including 0.90 mtr wide wkt gate with RCC column (03 Nos) ans all other relevent work complete all as specified such as excavation in any type of soil, in concrete 1:4:8 type D2 in foundation RCC pillars MS angle iron for steel gate and removal of surplus soil completee all as specified and shown of drawings.
Completion of incomplete works of Construction of mild steel gate 5.50 mtr wide (Gate No-4 EME REAR GATE) including 0.90 mtr wide wkt gate with RCC column (03 Nos) ans all other relevent work complete all as specified such as excavation in any type of soil, in concrete 1:4:8 type D2 in foundation RCC pillars MS angle iron for steel gate and removal of surplus soil completee all as specified and shown of drawings.
Completion of incomplete works of Construction of mild steel gate 5.50 mtr wide (Gate No-5 EME REAR GATE) including 0.90 mtr wide wkt gate with RCC column (03 Nos) ans all other relevent work complete all as specified such as excavation in any type of soil, in concrete 1:4:8 type D2 in foundation RCC pillars MS angle iron for steel gate and removal of surplus soil completee all as specified and shown of drawings.
Completion of incomplete works of Construction of Construction of 1.20 mtr widw mild steel wicket gate (CVY GD REAR GATE) with all other relevent work complete all as specified such as excavation in any type of soil, in concrete 1:4:8 type D2 in foundation RCC pillars MS angle iron for steel gate and removal of surplus soil completee all as specified and shown of drawings.
LUMPSUM PRE-PRICED SCHEDULES OF WORKS
Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule 'A' Part-II (SEC-I) brought forward from serial page No. 34
Lump sum price worked out by the contractor for INTERNAL /EXTERNAL ELECTRIC SUPPLY WORKS as listed in Schedule 'A' Part-III (SEC-I) brought forward from serial page No. 35
Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS listed in Schedule 'A' Part-IV brought forward from serial page No. 36
Lump sum price worked out by the contractor for SECURITY WALL WITH STELL GATE AND ALLIED WORKS as listed in Schedule 'A' Part-V brought forward from serial page No. 39.
Lump sum price worked out by the contractor for EXTERNAL ELECTRIC SUPPLY as listed in Schedule 'A' Part-VI (Section-I) brought forward from serial page No. 40
Lump sum price worked out by the contractor for EXCAVATION AND EARTH WORK FOR SCH 'A' PART-II TO VI AND SITE CLEARANCE as listed in Schedule 'A' Part-VII brought forward from serial page No. 41
Lump sum price worked out by the contractor for DISMANTLING AND DEMOLITION WORK as listed in Schedule 'A' Part-VIII brought forward from serial page No. 42
SCH 'A' PART-II(SEC-II) INTERNAL WATER SUPPLY WORKS
Valve pit of size 60cmx60cmx60cm(internal dimesnsions) brick masonry construction, including all necessary excavation and earth work in any type of soil, returing filling in disposal of surplus soil to a distance not exceeding 50m and depositing where directed, PCC in foundation of the mix (1:4:8) type D-2 (using 40mm graded crushed stone aggregate), PCC coping in PCC (1:2:4) Type B-0 using 12.5mm crushed stone graded aggregate, brick masonry in cement (1:4) internally, finished even and fair and pointing flush externally as the work proceedsin the same mortar, mild steel angle iron 50x50x6mm frame, MS sheet cover 3.15 mm thick with handle and locking arrangement, painting all the exposed MS Work with two coats of synthertic enamel paint of the tint as apporved by the GE over a coat of red oxide primer and painting all the MS embedded in plain cement concrete with two coats of black bituminous paint, complete all as specified and directed.
SCH 'A' PART-III (SEC-II) INTERNAL ELECTRIFICATION WORKS
Points wiring with 1.5 Sqmm multistranded copper conductor FRLS ISI marked PVC insulated unsheathed cable in and including concealed PVC conduits, medium grade, ISI marked not less than 20mm dia with all fittings/accessories and alsi including PVC insulated ISI marked unsheathed 1.5sqmm multistranded copper condutor FRLS as earth wire connected to common earth dolly and including sunk cast iron /pressed steel terminal boxes, junction boxes, other boxes not less than 2.00 mm thick sheet of suitable sizes for mounting of switches, sockets, fan ragulators, etc covered with 3mm thick plastic laminated sheet for (Make Hylum or equivalent ISI marked) for one light point or one fan point or one bell point, independent, controlled by one way switch/push button complete all as specified and directed.
All as per Serial item No 6.01 abpove but for one 3 pin socket outlet, 5 Amps independent.
Point wiring with 2.5Sqmm multistranded copper conductor FRLS (Multi strand) PVC insulated ISI Marked unsheathed cable in and including concealed PVC conduits, medium grade, ISI marked not less than 20mm dia with all fittings/accessories and also including PVC insulated ISI marked unsheathed 2.5 Sqmm multistranded condutor FRLS as earth wire connected to common earth dolly and including sunk cast iron/pressed steel terminal boxes, junction boxes, other boxes not less than 2.00 thick sheet of suitable sizes for mounting of switches, sockets, fan regulators, light fittings etc covered with 3mm thick plastic laminated sheet (Make Hylum or equivalent ISI marked) for one multi purpose two in one 5 & 15 Amps socket outlet independent, all as specified and directed. Note : Proper colour coding should be adopted for phase, neutral and earth and halves.
Flurosecent tube light fitting T-5, 1 x 28W, 230 Volt, surface/pendent mounted type, epoxy powder coated CRCA sheet housing completed with tube-01 No, lamp holder with replaceable electronic ballast having p.f not less than 0.9, connector block etc, complete with all accessories prewired and including connecting up with suitable size with three core twisted flexible copper conductor cable with suitable size (Bajaj Cat Nio BTIR 128 or Equivalent to CG, Havells, Phillips).
Su1x18 Watt CFL having PF not less than 0.9.
MCB SPN 240V, 50Hz, 10KA of rating (63A). Havells Cat Part No DHMCCSNF063 or equivalent.
MCB SPN 240V, 50HZ, 10KA of rating (6-32A). Havells Cat Part No DHMCCSNF06-32 or equivalent.
MCB SP 240V, 50HZ, 10KA of rating (6-32A). Havells Cat Part No DHMCCSNF06-32 or equivalent.
'Earthing complete with galvanized steel earth plate electrode 60cmx 60cmx6mm thickness not less than 6mm buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to GI and earth wire 4mm dia by means of nuts and bolts, check nuts and washers of GI medium grade pipe 15mm bore upto 7.5 meters including proven of concrete pit in PCC (1:2:4) type B-I using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4Kg/Sqm) and frame of angle iron 25x25x3mm 02 Nos lugs and handle made of 6mm dia MS bar made to shape, GI light grade 20mm bore pipe for watering perforated at bottom, placed on top edge of earth plate, charcoal and common salt filling, funnel, wire mesh and earth work in hard/dense soil, returining filling in and removal of surplus soil to a distance not exceeding 50mtr all as per electric plate No 3 of SSR Part-I and connecting to earth test point all as specified including testing on completion. Note for Item No 6.09 :- Item of earthing includes the cost of 7.5m long galvanised wire 4mm dia and protection pipe of 15mm bore GI medium grade. Extra lengths if required shall be provided by contractor without any extra cost to Govt.
SCH 'A' PART-VI (SEC-II) EXTERNAL ELECTRIC SUPPLY
Supply, installation, commisioning and testing of LT Panel, outdoor cubical type, factory made CPRI approved, fabricated out of 2mm thick mild steel sheet mounted 60cms above the ground level duly supported with mild steel angle iron 50mm x 50mm x 6mm thick in PCC foundation (1:2:4) type B-1, using 20mm graded crushed stone aggreagte. LT panel shall be totally enclsoed weather proof and vermin proof with front and rear opening with IP-54 protection as per IS-8623 duly powder coated painting both internally & externally for 433 volts, 3 phase, 50Hz, 4 wire having TPN aluminium bus bars suitable for 200 Amps load duly drilled holes for connections, RYB insulated with different colour code and sleeved insulators complete prewired and cable connection with suitable size of copper conductor wire upto aluminium bus bars including all incoming and outgoing cable connection with suitable size of aluminium lugs/glands complete all as specified and directed by Engr-in-Charge and also comprises of the foloowing:-
Supply and fix flood light fitting integral with aluminium reflected 150 Watt MH lamp fotting with ballast holder, lamp, heat resisiting rubber glass box black survilling, fixed to wall witrh angle iron bracket of 25x25x6mm size (L type) bent to shape as required grouted into wall fasteners /hold fast with MS clamp of required size, nuts/bolts/washers complete including necessary MCB control comprising one No MCB DB SPN 2 way with one MCB SPN 06A and connecting wire from DB to fitting all as specified and directed by Engr-in-Charge, Make Philips Cat No. MWF231 1xMHNTD-150WS or equivalent
Supply and fixing LED street light fitting with super flux high powdered LEDs, PLUTOLED street light 24 watt with plastic ABS fixture, superflux LEDs, in builkt power supply operating voltage range of 90-270 Volt AC. Complete including fixing arrangements with GI pipe bracket of 40mm dia light grade 1.5m long bent to shape and fixed to poles with 2 Nos clamps made out of MS flat 40x6mm with nuts, bolts/washer, including 2 runs of PVC insualted copper cable 2.5 Sqmm from junction box to light fitting complete all as specified and directed. Make Instapower Code 5250.02.240 or equivalent in any reputed manufacturer.
Supply and erection of outdoor type bus bar box with aluminium bus abar 50 Amp (TPN) with bus bar insulators, fabricated out of CRCA sheet 2mm thick of size 40cmx40cmx45cm erected on ground with 4 Nos angle iron support made out of 50x50x6mm size 01 mtr long (0.6m above groun d) including necessary earth work and PCC foundation netc painting with of box with 2 coats of synthetic enamel paint over a coat of red oxide primer with and including one No of MCB TPN 32 Amp (incomin) and 3 Nos MCB SPN 16 Amp (Outgoing) all as specified and directed.
Material and labour for outdoor type junction box of size 300x300x100mm fabricated out of CRCA sheet of 2mm thiock consisting of one MCB SPN 2.5Amp with 4 way aluminium busbar of capacity 40 amps fixed with bus bar insulator fixed to steel tubular poles with 2 NOs MS clamps made out of 40x60mm size with nuts/bolts/washers and painting with two coats of synthetic enamel paint over a coat of red oxide primer all as directed.
Earthing complete with galvanized steel earth plate electrode 60cmx 60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to GI and earth wire 4mm dia by means of nuts and bolts, check nuts and washers of GI medium grade pipe 15mm bore upto 7.5 meters including proven of concrete pit in PCC (1:2:4) type B-I using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4Kg/Sqm) and frame of angle iron 25x25x3mm 02 Nos lugs and handle made of 6mm dia MS bar made to shape, GI light grade 20mm bore pipe for watering perforated at bottom, placed on top edge of earth plate, charcoal and common salt filling, funnel, wire mesh and earth work in hard/dense soil, returining filling in and removal of surplus soil to a distance not exceeding 50mtr all as per electric plate No 3 of SSR 2009 Part-I and connecting to earth test point all as specified including testing on completion. Note : Item for earthing includes th cost of 7.5m long galvanised wire 32mmx6mm GI strip and protection pipe of 40mm bore GI medium grade extra lengths if required shall be provided by contractor without any extra cost to Govt.
Laying only and testing of cable XLPE insulated armoured heavy duty electric power cable with stranded aluminium conductor 1100 volts grade of size 3.5 core 95sqmm laid in trenches, ducts, wall, passing through GI pipe complete all as specified and direceted.
Laying only and testing of cable XLPE insulated armoured heavy duty electric power cable with stranded aluminium conductor 1100 volts grade of size 3.5 core 50sqmm laid in trenches, ducts, wall, passing through GI pipe complete all as specified and direceted.
Laying only and testing of cable XLPE insulated armoured heavy duty electric power cable with stranded aluminium conductor 1100 volts grade of size 4 core 25sqmm laid in trenches, ducts, wall, passing through GI pipe complete all as specified and direceted.
Laying only and testing of cable XLPE insulated armoured heavy duty electric power cable with stranded aluminium conductor 1100 volts grade of size 4 core 16sqmm laid in trenches, ducts, wall, passing through GI pipe complete all as specified and direceted.
Laying only and testing of cable XLPE insulated armoured heavy duty electric power cable with stranded aluminium conductor 1100 volts grade of size 4 core 10sqmm laid in trenches, ducts, wall, passing through GI pipe complete all as specified and direceted.
Laying only and testing of cable XLPE insulated armoured heavy duty electric power cable with stranded aluminium conductor 1100 volts grade of size 2 core 10sqmm laid in trenches, ducts, wall, passing through GI pipe complete all as specified and direceted. Note for iteme no 7.08 to 7.13 :- Cable XLPE shall be issued under Schdule 'B' for laying only.
M/S VALLEY ENTERPRISES CONSTRUCTION CO
M/S B A Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.06 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .