| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 LAccepted-AOC 00 HANSH NAGAR RADHA RAMAN ROAD MAINPURI MAINPURI UTTAR PRADESH 205001 | MAINPURI | UTTAR PRADESH | 205001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹2.1 L+₹9,548.56 (4.85%)Rejected-AOC 00 BHUSAR FARM KE PASS K K PURI NANDANPURA JHANSI UTTAR PRADESH 284003 | JHANSI | UTTAR PRADESH | 284003 | L2 | Rejected-AOC L2 | |
| 3 | L3₹2.2 L+₹21,112.56 (10.7%)Rejected-AOC | L3 | Rejected-AOC L3 |
Tender Value
₹2.0 L
Closing Date
20 Sept 2024, 12:00 pmClosed
CE OP Hamirpur
CE OP Hamirpur
Procurement of LT Distrubution box for 63 kVA DTR
2024_HPSEB_93150_1
NIQ-26/2024-25
Limited
Electrical Work/ Equipment
Item Rate
45 days
Area under CE OP Hamirpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
3 Oct 2024
13 Sept 2024
20 Sept 2024
13 Sept 2024
20 Sept 2024
14 Sept 2024
Amount
LT Distribution Panel Box suitable for 63 KVA Transformer/ Sub Station of size 900x800x200 mm +/- 5% made of steel sheet of 1.63 mm thickness having double door locking arrangement duly Powder coated painted complete with MCCB 100 Amps 3 Poles having following specifications (1) Minimum frame size 100 Amp (2) Type; fixed trip free (3) breaking capacity-Icu & Ics at 415, 50 Hz (KA) : Not less than 35 KA (4) Thermal release range : 100 Amp (5) Mechanical life (Operation) 25000 Nos. (6) Electrical life (Operation) 7000 No’s (7) Rated insulation voltage (V) : 690 V (8) Tripping Thermal Release Setting : Thermal O/L fixed setting (9) Tripping Magnetic release setting :Magnetic-S/C Fixed setting (12 in) (10) (Operation) voltage: 415V, AC (11) Calibration temperature : 50 Degree C (12) High voltage withstand voltage: 3KV for 1minute (13) Confirming to IS: 1993/60947-2,1989 (14) Make L&T/Havel/Schneider/ABB 15) ICS: 100% ICU Rectangular type Aluminium alloy bus bar of 100 Amps Having Length 600 mm for phase, 450 mm long for neutral outgoing feeders 2No. outgoing feeders shall be made in the panel U type rewire able Kit Kat fuses of 200 Amp shall be provided in all three phases The panel should be fully wired with insulated copper wire shall have adequate clearance as per specifications.
M/S A.K Enterprises
Maskin & Sons
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_137367.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .